• Title/Summary/Keyword: a frequency response

Search Result 4,814, Processing Time 0.034 seconds

A Novel Method for Measuring the Ground Impedance using Variable Frequency Inverter (가변주파수 인버터를 이용한 접지임피던스의 새로운 측정기법)

  • 이복희;엄주홍
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.253-257
    • /
    • 2004
  • In order to analyze the frequency dependance of ground impedance in grounding grids for lightning and surge protection, a novel method for measuring the ground impedance as a function of frequency were experimentally investigated. The experiments were carried out in rectangular grounding grids with $6{\times}8$ conductors of 22 $mm^2$ buried at a depth of 0.5 m. The test current was injected by the variable frequency inverter whose frequency is linearly controlled for the established period in the range of 5∼500 KHz. The amplitude and phase of ground impedance were calculated from the waveforms of the test current and ground potential rise measured by the band-pass filter tuned in a specific frequency. The frequency dependence of ground impedance was mainly caused by the inductive current flowing through grounding conductors over the frequency of 100 KHz. The proposed measurement method of ground impedance would be applicable to evaluate the transient response characteristics in lightning protection grounding systems.

New Adaptive Linear Combination Structure for Tracking/Estimating Phasor and Frequency of Power System

  • Wattanasakpubal, Choowong;Bunyagul, Teratum
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.28-35
    • /
    • 2010
  • This paper presents new Adaptive Linear Combination Structure (ADALINE) for tracking/estimating voltage-current phasor and frequency of power system. To estimate the phasors and frequency from sampled data, the algorithm assumes that orthogonal coefficients and speed of angular frequency of power system are unknown parameters. With adequate sampled data, the estimation problem can be considered as a linear weighted least squares (LMS) problem. In addition to determining the phasors (orthogonal coefficients), the procedure estimates the power system frequency. The main algorithm is verified through a computer simulation and data from field. The proposed algorithm is tested with transient and dynamic behaviors during power swing, a step change of frequency upon islanding of small generators and disconnection of load. The algorithm shows a very high accuracy, robustness, fast response time and adaptive performance over a wide range of frequency, from 10 to 2000 Hz.

Rotordynamic Analysis Using a Direction Frequency Response Function (방향성 주파수 응답 함수를 이용한 회전체 동역학 해석)

  • Donghyun, Lee;Byungchan, Jeon ;Byungock, Kim;Hyungsoo, Lim
    • Journal of Domestic Journal Test
    • /
    • v.11 no.2
    • /
    • pp.221-227
    • /
    • 2023
  • − A rotordynamic system consists of components that undergo rotational motion. These components include shafts, impellers, thrust collars, and components that support rotation, such as bearings and seals. The motion of this type of rotating system can be modeled as two-dimensional motion and, accordingly, the equa- tion of motion for the rotordynamic system can be represented using complex coordinates. The directional fre- quency response function (dFRF) can be derived from this complex coordinate system and used as an effective analytical tool for rotating machinery. However, the dFRF is not widely used in the field because most pre- vious studies and commercial software are based on real coordinate systems. The objective of the current study is to introduce the dFRF and show that it can be an effective tool in rotordynamic analysis. In this study, the normal frequency response function (nFRF) and dFRF are compared under rotordynamic analysis for isotropic and unisotropic rotors. Results show that in the nFRF, the magnitude of the response is the same for both pos- itive and negative frequencies, and the response is similar under all modes. Consequently, the severity of the mode cannot be identified. However, in the dFRF, the forward and backward modes are clearly distinguishable in the frequency domain of the isotropic rotor, and the severity of the mode can be identified for the uniso- tropic rotor.

Actrve Suspension Control using aFrequency-Shaped Performance Index (주파수 형태의 성능지수를 고려한 능동형 현가장치 제어)

  • 김희수;기창두;황원걸
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.299-304
    • /
    • 1993
  • A 1/4 car model(2 DOF system) is employed to evaluate the performance included a quadratic cost functional in frequency domain. The design procedure of feedback control to optimize the performance index results in a modified Linear-Quadratic-Gaussian problem and cultivates a quite simple control algorithm. Computer simulation result is shown that the LQG method using frequency shaped performance index is outstanding in ride comfort and its response converges to the steady state very rapidly in comparison with the known passive suspension, classical design methods LQR/ and LQG.

  • PDF

Continous rail absorber design using decay rate calculation in FEM

  • Molatefi, Habibollah;Izadbakhsh, Soroush
    • Structural Engineering and Mechanics
    • /
    • v.48 no.4
    • /
    • pp.455-466
    • /
    • 2013
  • In recent years, many countries have added railway noise to the issues covered by noise regulations. It is known that the rail is the dominant source of rolling noise at frequency range of 500Hz-2000Hz for the conventional speeds (<160km/h). One of the effective ways to reduce noise from railway track is using a rail vibration absorber. To study the acoustic performance of rail absorber, the decay rates of vibration have long been used by researcher. In this paper, A FE model of a periodic supported rail with infinite element in ABAQUS is developed to study the acoustic performance of the rail absorber. To compute the decay rates, acceleration responses along the rail transferred to MATLAB to obtain response levels in frequency domain and then by processing the response levels, the decay rates obtained for each1/3octav band. Continous rail absorber is represented by a steel layer and an elastomer layer. The decay rates for conventional rail and rail with one-side absorber and also, the rail with two side absorber are obtained and compared. Then, to improve the system of rail absorber, a steel plate with elastomer layer is added to bottom of the rail foot. The vertical decay rate results show that the decay rate of rail vibration along the track is significantly increased around the tuned frequency of the absorber and thus the rail vibration energy is substantially reduced in the corresponding frequency region and also effective in rail noise reduction.

S-Domain Frequency Dependent Network Equivalent for Electromagnetic Transient and Harmonic Assessment (전자기 과도현상 해석과 고조파 평가를 위한 S영역 주파수 의존 등가시스템 개발)

  • Wang, Y.P.;Chong, H.H.;Lee, J.T.;Han, H.H.;Kim, H.J.;Chong, D.I.;Kwak, N.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.143-144
    • /
    • 2006
  • The recent power systems are very complex and to model them completely is impractical for analysis of electromagnetic transient Therefore areas outside the immediate area of interest must be represented by some form of Frequency Dependent Network Equivalent (FDNE). In this paper a method for developing Frequency Dependent Network Equivalent (FDNE) using S-domain rational Function Fitting is presented and demonstrated. The FDNE is generated by Linearized Least Squares Fitting(LSF) of the frequency response of a S-domain formulation. This Three-port FDNE have been applied to the test AC power system. The electromagnetic transient package PSCAD/EMTDC is used to assess the transient response of the Three-port FDNE developed under different condition. The study results have indicated the robustness and accuracy of Three-port FDNE for analisys of electromagnetic transient and harmonic assessment.

  • PDF

Application of Optimal Control Techniques to SWATH Motion Control (반잠수 쌍동선의 최적 운동제어기 설계)

  • Chan-Wook Park;Bo-Hyeon Heo;Chun-Tae Song
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.31 no.2
    • /
    • pp.65-77
    • /
    • 1994
  • This paper presents a derailed application procedure of the linear quadratic(LQ) theory for a SWATH heave and pitch control. A time domain model of coupled, linear time-invariant second order differential equations is derived from the frequency response model with the frequency dependent added mass and damping approximated as constant values at the heave natural frequency. Wave exciting forces are modeled as a sum of sinusoids. A systematic selection procedure of state and control weighting matrices is presented to obtain good transient behavior and acceptable fin movement. The validity of this controller design process is throughly investigated by simulations both in time domain and frequency domain and singular value plots of transfer function matrices. The finally designed control system shows good overall performances revealing that the applicability of the present study is proved successful.

  • PDF

Analysis of Frequency Response Curve for Conduction-Cooled Power Capacitors (전도 냉각 파워 커패시터의 주파수 응답 곡선 분석)

  • An, Gyeong Moon;Kim, Hiesik
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.10
    • /
    • pp.123-130
    • /
    • 2016
  • High-frequency induction heating equipment can heat the metal by applying a High-Frequency power to the resonant circuit. The resonance circuit is composed of the work coil and the conduction-cooled power capacitor, it influences the performance of the heat treatment equipment according to the characteristics of the capacitor. However, dependence on conduction-cooled power capacitor's import is high due to lack of core technology research and development. Minimizing the generation of internal heat transmitted inside during LC resonance, reduce the reactive power loss, there is a need for a capacitor within the voltage characteristic outstanding. To implement localization it is vital that prior study of the analysis on the frequency response characteristic for the finished capacitor advanced manufacturer be implemented. Studying the interpolation method to read the value at any point of the characteristic curve for a given log-log scale was applied to the analysis tool of the capacitor by my proposed algorithm. The simulation for reproducing frequency response curves was attempted by assuming a capacitor in a simplified series equivalent RC circuit to obtain the equivalent series resistance value. It was confirmed that the reproduction rate was the result value above 83% as compared to the simulation of the properties and characteristics on the actual reactive power for Peak value, and that the algorithm can be applicable when analyzing and predicting the characteristic curves of a simpled model capacitor.

On the Application FH/SS Using Double Indirect Frequency Synthesizer (이중 간접 주파수 합성기를 이용한 FH/SS 적용에 관한 연구)

  • 정명덕;박재홍;김영민
    • Journal of the Korea Society of Computer and Information
    • /
    • v.4 no.1
    • /
    • pp.76-84
    • /
    • 1999
  • For FH/SS communication, We discussed the method of indirect frequency synthesizer in several methods. The problem of sing1e frequency synthesizer using with PLL is a varied coefficient value of damping factor in frequency hopping time, which is caused unstable frequency. So. for stable frequency synthesizer, a coefficient of damping factor must be optimized and synthesized to be removed excessive response time. In this paper, we studied FH using with double loop frequency synthesizer which takes stable frequency. We made up a simulator and had a good performance(real time speed).

  • PDF

A response spectrum method for seismic response analysis of structures under multi-support excitations

  • Li, Jian-Hua;Li, Jie
    • Structural Engineering and Mechanics
    • /
    • v.21 no.3
    • /
    • pp.255-273
    • /
    • 2005
  • Based on the random vibration theory, a response spectrum method is developed for seismic response analysis of linear, multi-degree-of-freedom structures under multi-support excitations is developed. Various response quantities, including the mean and variance of the peak response, the response mean frequency, are obtained from proposed combination rules in terms of the mean response spectrum. This method makes it possible to apply the response spectrum to the seismic reliability analysis of structures subjected to multi-support excitations. Considering that the tedious numerical integration is required to compute the spectral parameters and correlation coefficients in above combination rules, this paper further offers simplified procedures for their computation, which enhance dramatically the computational efficiency of the suggested method. The proposed procedure is demonstrated for tow numerical examples: (1) two-span continuous beam; (2) two-tower cabled-stayed bridge by using Monte Carlo simulation (MC). For this purpose, this paper also presents an approach to simulation of ground motions, which can take into account both mean and variation properties of response spectrum. Computed results based on the response spectrum method are in good agreement with Monte Carlo simulation results. And compared with the MSRS method, a well-developed multi-support response spectrum method, the proposed method has an incomparable computational efficiency.