• 제목/요약/키워드: a conversion factor

검색결과 863건 처리시간 0.029초

Interpretation of Animal Dose and Human Equivalent Dose for Drug Development

  • Shin, Jang-Woo;Seol, In-Chan;Son, Chang-Gue
    • 대한한의학회지
    • /
    • 제31권3호
    • /
    • pp.1-7
    • /
    • 2010
  • Objectives: To introduce to TKM scientific dose conversion methods of human to animal or animal to human for new drug investigations. Methods: We searched guidelines of the FDA and KFDA, and compared them with references for drug-dose conversion from various databases such as PubMed and Google. Then, we analyzed the potential issues and problems related to dose conversion in safety documentation of new herbal drugs based on our experiences during Investigational New Drug (IND) applications of TKM. Results: Dose conversion from human to animal or animal to human must be appropriately translated during new drug development. From time to time, investigators have some difficulty in determining the appropriate dose, because of misunderstandings of dose conversion, especially when they estimate starting dose in clinical or animal studies to investigate efficacy, toxicology and mechanisms. Therefore, education of appropriate dose calculation is crucial for investigators. The animal dose should not be extrapolated to humans by a simple conversion method based only on body weight, because many studies suggest the normalization method is based mainly on body surface area (BSA). In general, the body surface area seems to have good correlation among species with several parameters including oxygen utilization, caloric expenditure, basal metabolism, blood volume and circulating plasma protein. Likewise, a safety factor should be taken into consideration when deciding high dose in animal toxicology study. Conclusion: Herein, we explain the significance of dose conversion based on body surface area and starting dose estimation for clinical trials with safety factor.

지역특성을 고려한 수질오염총량관리 안전부하량 적용 (Application of Margin of Safety Considering Regional Characteristics for the Management of Total Maximum Daily Loads)

  • 박준대;오승영;김용석
    • 한국물환경학회지
    • /
    • 제30권3호
    • /
    • pp.351-360
    • /
    • 2014
  • The allocation of margin of safety (MOS) at a uniform rate to all areas of the unit watershed makes it very difficult to keep the load allotment stable in the area for lack of reduction measures like forest land. This study developed an equation to calculate margin of safety differentially according to the regional characteristics. The equation was formulated on the basis of the regional characteristic factors such as a load contribution factor for land use type and a site conversion factor for the unit watershed. The load contribution factor represents a contribution of loads from a particular land use. The site conversion factor was derived from the site conversion ratio of a unit watershed. Margin of safety for the non-point pollution load in the land use sector decreased by 20~25% in three river basins. The margin of safety in the unit watersheds with low site occupation ratios decreased in high rate, while in the unit watersheds with large urban area decreased in low rate. With the application of the differential margin of safety considering regional characteristics, not only the reduction of pollution loads can become lighter but also it can be easier to develop plans for Total Maximum Daily Loads (TMDLs) even where the reduction measures are not available.

The optimum conversion efficiency in nile blue arabinose system by photogalvanic cell

  • Lal, Mohan;Gangotri, K.M.
    • Advances in Energy Research
    • /
    • 제3권3호
    • /
    • pp.143-155
    • /
    • 2015
  • The Nile blue has been used as a photosensitizer with Arabinose as a reductant in photogalvanic cell for optimum conversion efficiency and storage capacity. Reduction cost of the photogalvanic cell for commercial utility. The generated photopotential and photocurrent are 816.0 mV and $330.0{\mu}A$ respectively. The maximum power of the cell is $269.30{\mu}W$ where as the observed power at power point is $91.28{\mu}W$. The observed conversion efficiency is 0.6095% and the fill factor 0.2566 has been experimentally found out at the power point of the photogalvanic cell, whereas the absolute value is 1.00. The photogalvanic cell so developed can work for 120.0 minutes in dark if it is irradiated for 200.0 minutes that is the storage capacity of photogalvanic cell is 60.00%. The effects of different parameters on the electrical output of the photogalvanic cell have been observed. A mechanism has also been proposed for the photogeneration of electrical energy.

임의시간 환산계수에 대한 Weiss 모형의 개선 (Improvement of Weiss Model on the Conversion Factor of Fixed- to True-Interval Rainfall)

  • 유철상;전창현
    • 대한토목학회논문집
    • /
    • 제31권4B호
    • /
    • pp.315-322
    • /
    • 2011
  • 본 연구에서는 임의시간 환산계수(Conversion Factor, CF)와 관련하여 거의 유일한 이론적 연구인 Weiss 모형을 자세히 검토하고, 그 문제점을 보완한 수정 Weiss 모형을 제안하였다. 아울러 강우의 특성을 반영하지 못하는 이들 모형의 한계를 극복하는 시도의 하나로서 강우의 시간분포 특성을 고려허여 CF를 추정하고 이를 실제 관측 자료에 근거한 CF와 비교하였다. 그 결과 수정 Weiss 모형을 근거로 산정한 CF 값은 강우 시간분포의 형태에 따라 다양한 값으로 나타났다. 특히, 중앙으로 집중된 강우 시간분포 형태에 대한 이론적인 CF 값이 실측 자료에 근거한 국내 외 CF 값들과 매우 유사한 것을 확인할 수 있었다.

AC-DC 전력변환기의 역률개선 제어기법에 관한 연구 (A study on control strategy of power factor correction for AC-DC power conversion system)

  • 곽동걸;이현우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 추계학술대회 논문집
    • /
    • pp.263-266
    • /
    • 2003
  • The high power factor converters are classified step-up, step-up-down and step-down converter, The power conversion system must be increased switching frequency in order to achieve a small size, a light weight and a low noise. And the power system brings on a high efficiency and high power factor. When a switch of the step down converter is operated with a commercial frequency(60Hz), a reactor using the converter is gone with a great number of harmonics waveforms of low grade. As results of this, the converter is decreased input power factor and is increased system size. To improved these, this paper proposes a PSM(Pulse Size Modulation) control strategy operated with high power factor.

  • PDF

고압 나트륨 램프 구동용 전력변환장치의 역률 개선 (Power Factor improvement of Power Conversion Equipment for High Pressure Sodium Lamps)

  • 이상현;서기영;이현우;이수흠;문상필
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.147-150
    • /
    • 2002
  • HPSL(High Pressure Sodium lamp)have attracted much attention in recent years, because they offer high luminous efficiency and very long life. Recently, AC-DC converters have been widely as power factor improvement circuits in the power conversion equipment An application of the ZVT-PWM(Zero Voltage Transition Pulse Width Modulation) boost converter, which has great advantage on miniaturization and high power density, to the power factor improvement circuit of the HPSL inverter are described to identify the power factor correction characteristics of the inverter. In this paper the series-parallel resonant inverter(electronic ballast) for driving a HPS lamp is discussed. Finally, a power factor corrector is cascaded in front of the electronic ballast. Consequently, a high power factor above 0.99 and low THD on the line current can be achieved.

  • PDF

비다짐 성토지반의 합리적 토량평가를 위한 토량환산계수 추정 (Estimation of Soil Conversion Factor for the Non-compacted Soil in Embankment)

  • 오세욱;이봉직;김홍석
    • 한국지반환경공학회 논문집
    • /
    • 제18권11호
    • /
    • pp.13-18
    • /
    • 2017
  • 단지조성을 위한 성토과정에서 비다짐 시공은 별도의 다짐을 수행하지 않고 장비하중에 의해 다져지게 하는 공법으로 대부분의 현장에서 적용하고 있으나 구체적인 시공지침이나 시방에 명시되지 않아 토공량 평가에 불명확한 점이 있다. 본 연구에서는 단지조성을 위한 지반조성을 수행함에 있어 비다짐 성토지반에 대한 설계 토량환산계수와 실제 토량환산계수 값을 비교하여 타당성 여부를 검토하고 실내시험 및 현장시험, 하중-침하시험 등을 수행하여 합리적인 토량환산계수를 제안함으로써 현장에서의 토공 적정성을 검토하기 위한 기초연구이다. 비다짐 시 토량환산계수 C값은 1.0으로 설계하고 있으나, 현장실험결과 0.86으로 설계보다 작은 것으로 나타나 성토량이 증가될 것으로 예측되었으며, 시공결과 실제로 성토량에 차이가 발생하였다. 따라서 비다짐 성토의 경우 현장여건 및 성토고의 자중을 고려하여 현장조건에 적합한 C값을 실험을 통하여 적용하는 것이 타당할 것으로 판단된다.

Validation of a Model for Estimating Individual External Dose Based on Ambient Dose Equivalent and Life Patterns

  • Sato, Rina;Yoshimura, Kazuya;Sanada, Yukihisa;Sato, Tetsuro
    • Journal of Radiation Protection and Research
    • /
    • 제47권2호
    • /
    • pp.77-85
    • /
    • 2022
  • Background: After the Fukushima Daiichi Nuclear Power Station (FDNPS) accident, a model was developed to estimate the external exposure doses for residents who were expected to return to their homes after evacuation orders were lifted. However, the model's accuracy and uncertainties in parameters used to estimate external doses have not been evaluated. Materials and Methods: The model estimates effective doses based on the integrated ambient dose equivalent (H*(10)) and life patterns, considering a dose reduction factor to estimate the indoor H*(10) and a conversion factor from H*(10) to the effective dose. Because personal dose equivalent (Hp(10)) has been reported to agree well with the effective dose after the FDNPS accident, this study validates the model's accuracy by comparing the estimated effective doses with Hp(10). The Hp(10) and life pattern data were collected for 36 adult participants who lived or worked near the FDNPS in 2019. Results and Discussion: The estimated effective doses correlated significantly with Hp(10); however, the estimated effective doses were lower than Hp(10) for indoor sites. A comparison with the measured indoor H*(10) showed that the estimated indoor H*(10) was not underestimated. However, the Hp(10) to H*(10) ratio indoors, which corresponds to the practical conversion factor from H*(10) to the effective dose, was significantly larger than the same ratio outdoors, meaning that the conversion factor of 0.6 is not appropriate for indoors due to the changes in irradiation geometry and gamma spectra. This could have led to a lower effective dose than Hp(10). Conclusion: The estimated effective doses correlated significantly with Hp(10), demonstrating the model's applicability for effective dose estimation. However, the lower value of the effective dose indoors could be because the conversion factor did not reflect the actual environment.

Malmquist 지수에 기초한 의료기관평가 대상 병원의 생산성 변동과 환산지수 변동에 관한 연구 (A Study on the relations between change of productivity and conversion factor of the Accredited Hospitals based on Malmquist index)

  • 오동일
    • 한국산학기술학회논문지
    • /
    • 제12권1호
    • /
    • pp.125-137
    • /
    • 2011
  • 본 연구에서는 1주기와 2 주기 모두 의료기관평가 대상이 된 병원의 Malmquist 지수를 구하고 지수변동의 원인을 분석하였다. 그 결과 평가대상이 된 병원의 Malmquist 방식에 의한 생산성 향상이 이루어졌음을 발견할 수 있었다. 의료기관평가점수와 생산성 변동과의 관계를 살펴본 결과 진료 및 운영체계 점수가 부문별성과 점수에 비해 높은 설명력을 가지고 있었다. 또한 생산성 향상이 큰 병원일수록 환산지수 하락 폭도 큰 것으로 나타났으며 이러한 결과는 병원의 종별, 그룹별, 지역별 모수 요인과도 독립적인 것으로 나타났다. 생산성 변동 폭이 큰 병원일수록 환산지수 하락 폭이 더 큰 것으로 나타나 수가계약의 한 요소로 생산성지표를 도입할 수 있는 가능성을 알 수 있었다. 이러한 결과는 정태적 효율성 보다는 다기간 생산성 변동을 반영한 환산지수 추정 모형과 지불제도 개편 시 다연도성과를 반영하는 메카니즘 개발이 검토되어야 한다는 점을 의미한다.

디지털사진측량 및 3D 레이저스캐너를 이용한 토랑환산계수의 산정 (A Estimation of Soil Conversion Factor Using Digital Photogrammetry and 3D Laser Scanner)

  • 이재기;정성혁;이계동
    • 한국측량학회지
    • /
    • 제24권2호
    • /
    • pp.227-234
    • /
    • 2006
  • 건설교통부에서는 예산절감을 위해 토석정보시스템을 운영하고 있으며, 시스템 운영에 기본적으로 고려되어야 할 사항은 원지반의 토량을 기준으로 산정되는 토량 변화율인 토량환산계수의 정확한 적용이다. 토공사의 절성토량의 균형, 사토장 및 토취장의 계획은 공사비와 직접적인 관계를 가지고 있기 때문에 정확한 토공량 산정 및 효율적인 토공유동이 무엇보다도 중요하다고 할 수 있다. 그러나 현장에서의 비합리적인 토량환산계수의 적용으로 토공유동이 효과적이지 못한 점이 있으며, 정확한 공사비 산정 및 투입에도 지장을 초래할 수 있다. 이와 같이 효율적인 토공유동계획은 토공량 산정의 정확도에 기인한다고 할 수 있으며, 정확한 토량환산계수의 적용이 토공량 산정에 절대적이라 할 수 있다. 본 연구에서는 대규모 토공사가 실시되는 현장을 대상으로 대상지 내의 임의지점 절 성토부를 굴착하고 굴착 전후 및 다짐후의 체적을 사진측량기법 및 레이저스캐닝기법으로 정밀한 수치표고모형을 제작하여 토량환산계수를 산정하고, 동시에 절 성토부 건조밀도시험을 통해 산정되는 토량변화율의 결과값과 비교 분석하여 신뢰성 있는 토량환산계수의 산정방법을 결정하고자 한다.