• Title/Summary/Keyword: a angle detector

Search Result 178, Processing Time 0.036 seconds

Feasibility Analysis of Exploring Underground Utilities Using Muon (뮤온 입자를 활용한 지하매설물 탐사 가능성 분석)

  • Seo, Seunghwan;Chung, Moonkyung;Kwak, Kiseok;Kang, Jae Mo
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.11
    • /
    • pp.137-147
    • /
    • 2022
  • Various geophysical exploration methods are used to determine the exact location of underground utilities, and many studies have been performed to improve the accuracy. This study analyzed the feasibility of exploring underground utilities through a new exploration method using cosmic ray muon. A prototype of a portable muon detector was manufactured by combining a scintillator and a silicon photomultiplier. Further, a calibration operation was performed on the muon count rate. The ground thickness of the ground model was measured using the muon detector prototype, where the value could be estimated with an error of about 3%, close to the actual. In addition, the theoretical basis for tomography analysis technology was analyzed to utilize the muon detector for exploring underground utilities, and a zenith angle correction method was presented. This study revealed that the technology of exploration using muon can analyze density with high resolution and will be used for exploring underground utilities.

Crop-row Detection by Color Line Sensor

  • Ha, S.ta;T.Kobaysahi;K.Sakai
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1993.10a
    • /
    • pp.353-362
    • /
    • 1993
  • The purpose of this study is to develop a crop-row detector which can be applied to an automatic row following control for cultivators or thinning machines. In this report, a possibility of new crop-row detecting method was discussed. This detecting method consists of two principal means. One is the hardware means to convert the two dimensional crop-row vision to the compacted one dimensional information. The conversion is achieved by a color line sensor and a rotating mirror. In order to extract crop-row , R and G signals of RGB color system are used. The locations of two different points on the target row are detected by this means. Another is the software means to estimate the offset value and the heading angle between the detector and the target row which can be assumed as a straight line. As a result of discussion, it was concluded that this detecting method would be accurate enough for practical use.

  • PDF

Instantaneous Switching-Angle Control Scheme for Precise Speed Control of an SRM (SRM의 정밀속도제어를 위한 순시스위칭각 제어방식)

  • 안진우;오석규;황영문
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.454-459
    • /
    • 1997
  • The good features of a switched reluctance motor(SRM) are appreciated by the appliance manufactures. And it is spread into a commercial and industries market. The few disadvantage of the motor is higher torque ripple and noise. This paper proposes an instantaneous torque control scheme to control a speed precisely. It adapts phase-locked loop (PLL) technique to control speed precisely. In this control scheme, the phase detector signal of the PLL regulates the switching dwell angle flexibly and the loop filter's signal controls adaptively the instantaneous switching voltage. Experimental results show that drive performance is good with low torque ripple.

  • PDF

Dynamic Analysis of ATM Double Bill Detector (ATM기 2매 검지부의 동적 해석)

  • Jeong, Joong-Ki;Suh, Jun-Ho;Baek, Yoon-Kil;Choi, Yeon-Sun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.12 s.117
    • /
    • pp.1208-1214
    • /
    • 2006
  • ATM(automated-teller machine) is a machine that receives and pays money directly. The double bill detector(DBD) module of an ATM detects double bills from its thickness. In this paper, the dynamic behavior of the DBD was analyzed, which cannot be simulated correctly by a package program of SAMCEF. And the displacements of the lever was measured for various bills experimentally. The measured dynamic behaviors were analyzed kinematically using a vector equation and simulated dynamically by the derivation of equation of motion with consideration of damping and stiffness of the DBD and bills. The analysis showed that the spring constant of the system is not so influential, instead, the contact angle between the lever and bill needs to be larger than the existing DBD in order to be laster and reliable DBD.

New Gray Level Corner Point Detection Method (새로운 그레이 레벨 코너점 검출 방법)

  • 나재형;오해석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.8C
    • /
    • pp.1062-1068
    • /
    • 2004
  • In this paper, we introduce a new gray level comer detection method to recognize corner points accurately. The new corner detector divides the corner region into many homocentric circles according to the window size, and calculates the corner response and angle of corner area about each layer to get an accurate corner point. The new corner detector has a hierarchical structure so it can detect corner point more quickly than general gray level corner detector

An Experimental Study of Flow Behaviour in Underground Stairway Fire (지하계단 화재에서 유동에 대한 실험연구)

  • 정진용;홍기배;이재하;유홍선
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.10
    • /
    • pp.821-827
    • /
    • 2003
  • Reduced-scale experimental study was carried out on the heat flow behavior which flows under the sloped ceiling in underground fire. Temperature and flow velocity were measured to characterize the ceiling jet along the sloped stairway ceiling. The methanol fuel was used as a model fire source giving 2.2 and 3.4 kW, with changing the slope angle of stairway adopting of 15, 25, 35, and 45 deg. Based on the experimental data, excess temperature and velocity along the sloped stairway ceiling were examined which are usefully applicable to estimate the activating conditions of heat detector and sprinkler head mounted on the sloped ceiling. Excess temperature in upper exit of the sloped stairway was also examined to analyze the soffit which delays the smoke diffusion. The result shows that the activating conditions of heat detector and sprinkler in the sloped stairway ceiling have to be considered differently in a point of about 30 deg.

Comparison of Exposure dose according to the C-arm Angle Change (C-arm 각도 변화에 따른 피폭선량 비교)

  • Shin, Seong-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.9
    • /
    • pp.453-458
    • /
    • 2011
  • This study aimed to figure out the change of exposure dose to the radiologist according to the C-arm angle change. For the exam it was fixed with 101 kvp and 4.9mA for the exposure time with 3 seconds and 5 seconds respectively. C-arm Tube was located both under and over, then the average was taken after performing for 5 times with the change of angle from -30 degree to 0, 30, 60 and 90 degree. The detector measured in 160cm high from the position of the radiologist who operates the C-arm. The measurement was shown its highest result at -30 degree followed by 0, 30, 60, 90 from the highest order. Over tube method is higher than under tube method. Therefore, to reduce the exposure dose of the radiologist, it is required for using under tube method instead of over tube method. When the angle change is made, it is recommended to use the angle that tube is growing further apart from the radiologist. And it is also necessary to shorten exposed time as much as possible to create the same quality image and also to reduce the exposure dose.

The Clinical usefulness of the tangential projection view of Radius groove after Distal Radius Fracture operation using the T-type Plat (전방 잠금형 금속판을 이용한 요골 원위부 골절수술 후 요골구 접선방향 촬영법의 임상적 유용성)

  • Seo, Sun-Youl;Cho, Jeong-Hee;Han, Man-Seok;Kim, Tae-Hyung;Yoo, Se-Jong;Kim, Yong-Kyun;Han, Dong-Kyoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.6
    • /
    • pp.2760-2766
    • /
    • 2013
  • Introduction : The projection method to check existence and nonexistence of radius groove penetration of screw after distal radius fracture operation clinical using the T-type plate and the radiation of radial groove tangential is to propose a new test. Material and Methods : On the tangential projection view of radius groove, elevation angle of distal radius is 2.5, 5, 7.5, 10 degree. and forearm and radiation detector of angle is 60, 70, 80, degree each changed. that analyzed check existence and nonexistence of radius groove penetration of screw. Results : For the image of Radial groove tangential. the case of not radius groove penetration of screw(63.95%, n=55), medial penetration of radius groove(10.47%, n=9) or lateral penetration of radius groove(25.58%, n=22) was analysis. The radius groove penetrating of screw length was a range of 0.43 ~ 2.72mm, the average was 1.06mm. the check existence and nonexistence of radius groove penetration of medial or lateral was analysis that it accurate for the image of Radial groove tangential. the radiography of radial groove is well described elevation angle of distal radius 2.5 to 7.5 degree(90% over), forearm and radiation detector of angle 70degree(80%over) Conclusion : It is elevation angle of distal radius is 5degree, forearm and radiation detector of angle 70degree recommended.

STUDY ON THE EFFECT OF THE SELF-ATTENUATION COEFFICIENT ON γ-RAY DETECTOR EFFICIENCY CALCULATED AT LOW AND HIGH ENERGY REGIONS

  • El-Khatib, Ahmed M.;Thabet, Abouzeid A.;Elzaher, Mohamed A.;Badawi, Mohamed S.;Salem, Bohaysa A.
    • Nuclear Engineering and Technology
    • /
    • v.46 no.2
    • /
    • pp.217-224
    • /
    • 2014
  • The present work used the efficiency transfer method used to calculate the full energy peak efficiency (FEPE) curves of the (2"*2" & 3"*3") NaI (Tl) detectors based on the effective solid angle subtended between the source and the detector. The study covered the effect of the self attenuation coefficient of the source matrix (with a radius greater than the detector's radius) on the detector efficiency. $^{152}$ An Eu aqueous radioactive source covering the energy range from 121.78 keV up to 1408.01 keV was used. In this study an empirical formula was deduced to calculate the difference between the measured and the calculated efficiencies [without self attenuation] at low and high energy regions. A proper balance between the measured and calculated efficiencies [with self attenuation] was achieved with discrepancies less than 3%, while reaching 39% for calculating values [without self attenuation] due to working with large sources, or for low photon energies.

A Study on Analysis and Improvement of Current Korean Army's Mine Detector (한국 군 운용 지뢰 탐지기 현실태 분석 및 개선 방안 연구)

  • Kim, Chi-Wook
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.5
    • /
    • pp.229-233
    • /
    • 2013
  • Mine detector of troops is different from other equipments. It is a base of a miner branch's combat, combat support and mission. But its notion is too obsucure and each troops' model and maker of it is so different and most of it is old type so there are a lot of malfunctions. Hence, I will define management of mine detector and figure out these days miner troops' mine detector situation. I will collect experts' opinions too. Through a discussion we could found improvement plan and develop it adequate for future operational environment. Proceeding all these courses and finally making it weaponize are the points of this writing.