Browse > Article
http://dx.doi.org/10.5762/KAIS.2013.14.6.2760

The Clinical usefulness of the tangential projection view of Radius groove after Distal Radius Fracture operation using the T-type Plat  

Seo, Sun-Youl (Department of Public Health, The Graduate School of Eulji University)
Cho, Jeong-Hee (Department of Public Health, The Graduate School of Eulji University)
Han, Man-Seok (Kangwon University department of radiiologic science)
Kim, Tae-Hyung (Kangwon University department of radiiologic science)
Yoo, Se-Jong (Department of Public Health The Graduate School of Konyang University)
Kim, Yong-Kyun (Department of Radiological Technology, Daewon University College)
Han, Dong-Kyoon (Eulji University department of radiiologic science)
Publication Information
Journal of the Korea Academia-Industrial cooperation Society / v.14, no.6, 2013 , pp. 2760-2766 More about this Journal
Abstract
Introduction : The projection method to check existence and nonexistence of radius groove penetration of screw after distal radius fracture operation clinical using the T-type plate and the radiation of radial groove tangential is to propose a new test. Material and Methods : On the tangential projection view of radius groove, elevation angle of distal radius is 2.5, 5, 7.5, 10 degree. and forearm and radiation detector of angle is 60, 70, 80, degree each changed. that analyzed check existence and nonexistence of radius groove penetration of screw. Results : For the image of Radial groove tangential. the case of not radius groove penetration of screw(63.95%, n=55), medial penetration of radius groove(10.47%, n=9) or lateral penetration of radius groove(25.58%, n=22) was analysis. The radius groove penetrating of screw length was a range of 0.43 ~ 2.72mm, the average was 1.06mm. the check existence and nonexistence of radius groove penetration of medial or lateral was analysis that it accurate for the image of Radial groove tangential. the radiography of radial groove is well described elevation angle of distal radius 2.5 to 7.5 degree(90% over), forearm and radiation detector of angle 70degree(80%over) Conclusion : It is elevation angle of distal radius is 5degree, forearm and radiation detector of angle 70degree recommended.
Keywords
Colles' Fracture; Radial groove; T-type plate; Flexor pollicis longus Tendon;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Simic PM, Robison J, Gardner MJ, Gelberman RH, Weiland AJ, Boyer MI. "Treatment of distal radius fractures with a low-profile dorsal plating system: an outcomes assessment". J Hand Surg Am, 31, pp. 382-6, 2006. DOI: http://dx.doi.org/10.1016/j.jhsa.2005.10.016   DOI   ScienceOn
2 Kamath AF, Zurakowski D, Day CS. "Low-profile dorsal plating for dorsally angulated distal radius fractures: an outcomes study". J Hand Surg Am, 31, pp. 1061-7, 2006. DOI: http://dx.doi.org/10.1016/j.jhsa.2006.05.008   DOI   ScienceOn
3 Herron M, Faraj A, Craigen MA. "Dorsal plating for displaced intra-articular fractures of the distal radius". Injury, 34, pp. 497-502, 2003. DOI: http://dx.doi.org/10.1016/S0020-1383(02)00190-0   DOI   ScienceOn
4 Jupiter JB, Fernandez DL. "Complications following distal radial fractures". Instr Course Lect, 51, pp. 203-19, 2002.
5 Benson EC, DeCarvalho A, Mikola EA, Veitch JM, Moneim MS. "Two potential causes of EPL rupture after distal radius volar plate fixation". Clin Orthop Relat Res, 451, pp. 218-22, 2006. DOI: http://dx.doi.org/10.1097/01.blo.0000223998.02765.0d   DOI
6 Rampoldi M, Marsico S. "Complications of volar plating of distal radius fractures". Acta Orthop Belg, 73, pp. 714-9, 2007.
7 Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M. "Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate". J Orthop Trauma, 21, pp. 316-22, 2007. DOI: http://dx.doi.org/10.1097/BOT.0b013e318059b993   DOI   ScienceOn
8 Bianchi S, van Aaken J, Glauser T, Martinoli C, Beaulieu JY, Della Santa D. "Screw impingement on the extensor tendons in distal radius fractures treated by volar plating: sonographic appearance". AJR Am J Roentgeno, 191, pp. 199-203, 2008. DOI: http://dx.doi.org/10.2214/AJR.08.1057   DOI   ScienceOn
9 Knight D, Hajducka C, Will E, McQueen M. "Locked volar plating for unstable distal radial fractures: clinical and radiological outcomes". Injury, 41, pp. 184-9, 2010. DOI: http://dx.doi.org/10.1016/j.injury.2009.08.024   DOI   ScienceOn
10 Perry DC, Machin DM, Casaletto JA, Brown DJ. "Minimising the risk of extensor pollicis longus rupture following volar plate fixation of distal radius fractures: a cadaveric study". Ann R Coll Surg Engl, 93, pp. 57-60, 2011. DOI: http://dx.doi.org/10.1308/003588411X12851639107151   DOI   ScienceOn
11 Letsch R, Infanger M, Schmidt J, Kock HJ. "Surgical treatment of fractures of the distal radius with plates: a comparison of palmar and dorsal plate position". Arch Orthop Trauma Surg, 123, pp. 333-9, 2003. DOI: http://dx.doi.org/10.1007/s00402-003-0538-4   DOI   ScienceOn
12 Sun Youl Seo, Gi Jang Hong, mMan Seock Han, Young Gun Gim, "The Tangential Projection method for Checking Existence and Nonexistence of Radius Groove Penetrtion of Scrow after Distal Radius Operation Used the T-type Plate". Korea society of Radiogical Science, 33(4), pp.335-340, 2010.   과학기술학회마을
13 Maschke SD, Evans PJ, Schub D, Drake R, Lawton JN. "Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study". Hand (N Y), 2, pp. 144-50, 2007 DOI: http://dx.doi.org/10.1007/s11552-007-9038-2   DOI
14 Jin Ho Cho, Hyoung Keun Oh. "Attritional Flexor Tendon Rupures after Malunited Distal Radius Fracture". Journal of the Korean Fracture Society, 19(1), 2006.
15 Berglund LM, Messer TM. "Complications of volar plate fixation for managing distal radius fractures". J Am Acad Orthop Surg, 17, pp, 369-77, 2009.   DOI
16 Colles A. "On the fracture of the carpal extremity of the radius". Edinb Med Surg J, 10, pp. 182-6, 1814.