• Title/Summary/Keyword: Zygomatic implant

Search Result 7, Processing Time 0.032 seconds

Selective laser melted titanium implants: a new technique for the reconstruction of extensive zygomatic complex defects

  • Rotaru, Horatiu;Schumacher, Ralf;Kim, Seong-Gon;Dinu, Cristian
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.1.1-1.6
    • /
    • 2015
  • The restoration of extensive zygomatic complex defects is a surgical challenge owing to the difficulty of accurately restoring the normal anatomy, symmetry, proper facial projection and facial width. In the present study, an extensive post-traumatic zygomatic bone defect was reconstructed using a custom-made implant that was made with a selective laser melting (SLM) technique. The computer-designed implant had the proper geometry and fit perfectly into the defect without requiring any intraoperative adjustments. A one-year follow-up revealed a stable outcome with no complications.

Maxillary resection for cancer, zygomatic implants insertion, and palatal repair as single-stage procedure: report of three cases

  • Salvatori, Pietro;Mincione, Antonio;Rizzi, Lucio;Costantini, Fabrizio;Bianchi, Alessandro;Grecchi, Emma;Garagiola, Umberto;Grecchi, Francesco
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.13.1-13.8
    • /
    • 2017
  • Background: Oronasal/antral communication, loss of teeth and/or tooth-supporting bone, and facial contour deformity may occur as a consequence of maxillectomy for cancer. As a result, speaking, chewing, swallowing, and appearance are variably affected. The restoration is focused on rebuilding the oronasal wall, using either flaps (local or free) for primary closure, either prosthetic obturator. Postoperative radiotherapy surely postpones every dental procedure aimed to set fixed devices, often makes it difficult and risky, even unfeasible. Regular prosthesis, tooth-bearing obturator, and endosseous implants (in native and/or transplanted bone) are used in order to complete dental rehabilitation. Zygomatic implantology (ZI) is a valid, usually delayed, multi-staged procedure, either after having primarily closed the oronasal/antral communication or after left it untreated or amended with obturator. The present paper is an early report of a relatively new, one-stage approach for rehabilitation of patients after tumour resection, with palatal repair with loco-regional flaps and zygomatic implant insertion: supposed advantages are concentration of surgical procedures, reduced time of rehabilitation, and lowered patient discomfort. Cases presentation: We report three patients who underwent alveolo-maxillary resection for cancer and had the resulting oroantral communication directly closed with loco-regional flaps. Simultaneous zygomatic implant insertion was added, in view of granting the optimal dental rehabilitation. Conclusions: All surgical procedures were successful in terms of oroantral separation and implant survival. One patient had the fixed dental restoration just after 3 months, and the others had to receive postoperative radiotherapy; thus, rehabilitation timing was longer, as expected. We think this approach could improve the outcome in selected patients.

Recent advances in dental implants

  • Hong, Do Gia Khang;Oh, Ji-hyeon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.33.1-33.10
    • /
    • 2017
  • Dental implants are a common treatment for the loss of teeth. This paper summarizes current knowledge on implant surfaces, immediate loading versus conventional loading, short implants, sinus lifting, and custom implants using three-dimensional printing. Most of the implant surface modifications showed good osseointegration results. Regarding biomolecular coatings, which have been recently developed and studied, good results were observed in animal experiments. Immediate loading had similar clinical outcomes compared to conventional loading and can be used as a successful treatment because it has the advantage of reducing treatment times and providing early function and aesthetics. Short implants showed similar clinical outcomes compared to standard implants. A variety of sinus augmentation techniques, grafting materials, and alternative techniques, such as tilted implants, zygomatic implants, and short implants, can be used. With the development of new technologies in three-dimension and computer-aided design/computer-aided manufacturing (CAD/CAM) customized implants can be used as an alternative to conventional implant designs. However, there are limitations due to the lack of long-term studies or clinical studies. A long-term clinical trial and a more predictive study are needed.

Frontal augmentation as an adjunct to orthognathic or facial contouring surgery

  • Park, Young-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.37.1-37.5
    • /
    • 2016
  • Background: The dimensions and shape of the forehead determine the esthetics of the upper third of the face. Korean young people consider a broad and smooth, rounded forehead more attractive. As a result, frontal augmentation becomes more popular in patients with dentofacial deformities. Various surgical procedures and materials have been used in frontal augmentation surgery, with associated advantages and disadvantages. Silicone is a good candidate for frontal augmentation. The author presents two cases of esthetic frontal augmentation with a prefabricated silicone implant in female patients with dentofacial deformities. Case presentation: In case 1, a 24-year-old female patient underwent frontal augmentation surgery with simultaneous maxillomandibular and zygomatic osteotomies to correct facial asymmetry. A silicone implant was fabricated preoperatively using a positive template stone mold of her forehead. In case 2, a 23-year-old female patient underwent total facial contouring surgery including frontal augmentation for improved facial esthetics. A computed tomography (CT)-guided rapid prototype (RP) model was used to make the silicone implants. The operative procedure was safe and simple, and the silicone implants were reliable for a larger degree of frontal augmentation. Six months later, both patients had recovered from the surgery and were satisfied with their frontal shape and projection. Conclusions: Frontal augmentation with silicone implants can be an effective adjuvant strategy to improve facial esthetics in patients with a flat and narrow forehead who undergo orthognathic reconstruction or total facial contouring surgery.

CORRECTION OF POSTTRAUMATIC DIPLOPIA AND ENOPHTHALMOS USING AUTOGENOUS COMPOSITE CONCHAL CARTILAGE AND TEMPORAL FASCIAL;A CASE REPORT (이개연골과 측두근막의 자가복합이식술에 의한 외상성 복시현상과 안구함몰의 치험례)

  • Kim, Il-Kyu;Lee, Seong-Jun;Ha, Soo-Yong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.12 no.1
    • /
    • pp.114-120
    • /
    • 1990
  • This is a case report of correction of posttraumatic diplopia and enophthalmos using autogenous composite conchal cartilage and temporal fascia. The results are as follows. 1. Diplopia and enophthalmos may be persistent complications in zygomatic complex fracture. 2. The concha is a reservior of autogenous cartilage which leaves no cosmetic and functional deformity in reconstruction of orbital floor. 3. Warpping the cartilage in temporal fascia may serve to increase implant stability and get graft with smooth edge. 4. Donor incision lines are well hidden within the scalp and in auriculocephalic fold.

  • PDF

Infraorbital nerve transpositioning into orbital floor: a modified technique to minimize nerve injury following zygomaticomaxillary complex fractures

  • Kotrashetti, Sharadindu Mahadevappa;Kale, Tejraj Pundalik;Bhandage, Supriya;Kumar, Anuj
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.2
    • /
    • pp.74-77
    • /
    • 2015
  • Objectives: Transpositioning of the inferior alveolar nerve to prevent injury in lower jaw has been advocated for orthognathic, pre-prosthetic and for implant placement procedures. However, the concept of infra-orbital nerve repositioning in cases of mid-face fractures remains unexplored. The infraorbital nerve may be involved in trauma to the zygomatic complex which often results in sensory disturbance of the area innervated by it. Ten patients with infraorbital nerve entrapment were treated in similar way at our maxillofacial surgery centre. Materials and Methods: In this article we are reporting three cases of zygomatico-maxillary complex fracture in which intra-operative repositioning of infra-orbital nerve into the orbital floor was done. This was done to release the nerve from fractured segments and to reduce the postoperative neural complications, to gain better access to fracture site and ease in plate fixation. This procedure also decompresses the nerve which releases it off the soft tissue entrapment caused due to trauma and the organized clot at the fractured site. Results: There was no evidence of sensory disturbance during their three month follow-up in any of the patient. Conclusion: Infraorbital nerve transposition is very effective in preventing paresthesia in patients which fracture line involving the infraorbital nerve.

The Efficacy of Bioabsorbable Mesh in Craniofacial Trauma Surgery

  • Choi, Won Chul;Choi, Hyun Gon;Kim, Jee Nam;Lee, Myung Cheol;Shin, Dong Hyeok;Kim, Soon Heum;Kim, Cheol Keun;Jo, Dong In
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.3
    • /
    • pp.135-139
    • /
    • 2016
  • Background: The ultimate goal of craniofacial reconstructive surgery is to achieve the most complete restoration of facial functions. A bioabsorbable fixation system which does not need secondary operation for implant removal has been developed in the last decade. The purpose of this study is to share the experience of authors and to demonstrate the efficacy of bioabsorbable mesh in a variety of craniofacial trauma operations. Methods: Between October 2008 and February 2015, bioabsorbable meshes were used to reconstruct various types of craniofacial bone fractures in 611 patients. Any displaced bone fragments were detached from the fracture site and fixed to the mesh. The resulting bone-mesh complex was designed and molded into an appropriate shape by the immersion in warm saline. The mesh was molded once again under simultaneous warm saline irrigation and suction. Results: In all patients, contour deformities were restored completely, and bone segments were fixed properly. The authors found that the bioabsorbable mesh provided rigid fixation without any evidence of integrity loss on postoperative computed tomography scans. Conclusion: Because bioabsorbable meshes are more flexible than bioabsorbable plates, they can be molded and could easily reconstruct the facial bone in three dimensions. Additionally, it is easy to attach bone fragments to the mesh. Bioabsorbable mesh and screws is effective and can be easily applied for fixation in various craniofacial trauma reconstructive scenarios.