• 제목/요약/키워드: Zero-vector

검색결과 301건 처리시간 0.034초

폴전압을 이용한 SVPWM 인버터의 과변조 기법 (An Overmodulation Strategy for SVPWM Inverter Using Pole Voltage)

  • 한대웅;김상훈;송영신;이은규
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.181-184
    • /
    • 2001
  • In this paper, a novel overmodulation strategy for space-vector PWM(SVPWM) inverters to utilize dc link voltage fully is presented. The proposed strategy uses the concept of SVPWM based on the zero sequence signal(offset voltage) injection principle. So, by modifying the pole voltage simply, the linear control of inverter output voltage over the whole overmodulation range can be achieved easily. The validity of the proposed strategy is confirmed by the experimental results.

  • PDF

속도센서리스 벡터제어에 의한 유도전동기 운전 (A Study on vector control of induction motor drive using a speed sensorless)

  • 이춘상
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.417-420
    • /
    • 2000
  • In order to the torque control the indirect flux control was performed by controlling the ratio of e/f and the q-axis flux was estimated by the slip command and q-axis flux was estimated by the slip command and q-axis current in the rotor circuits. Also the frequency was controlled to keep on the q-axis flux to be zero and the constant torque characteristics could be obtained by generation the preset torque. In the induction motor driven by the boltage source inverter with the constant voltage and frequency the speed variation is expressed as a slip So the speed control can be achieved by slip compensation The slip was calculated with a q-flux current filtered by first-order filter and as the result the error problem which may occur in current detection was eliminated

  • PDF

VPI-based Control Strategy for a Transformerless MMC-HVDC System Under Unbalanced Grid Conditions

  • Kim, Si-Hwan;Kim, June-Sung;Kim, Rae-Young;Cho, Jin-Tae;Kim, Seok-Woong
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2319-2328
    • /
    • 2018
  • This paper introduces a control method for a transformerless MMC-HVDC system. The proposed method can effectively control the grid currents of the MMC-HVDC system under unbalanced grid conditions such as a single line-to-ground fault. The proposed method controls the currents of the positive sequence component and the negative sequence component without separating algorithms. Therefore, complicated calculations for extracting the positive sequence and the negative sequence component are not required. In addition, a control method to regulate a zero sequence component current under unbalanced grid conditions in the transformerless MMC-HVDC system is also proposed. The validity of the proposed method is verified through PSCAD/EMTDC simulation.

SURFACES OF REVOLUTION SATISFYING ΔIIG = f(G + C)

  • Baba-Hamed, Chahrazede;Bekkar, Mohammed
    • 대한수학회보
    • /
    • 제50권4호
    • /
    • pp.1061-1067
    • /
    • 2013
  • In this paper, we study surfaces of revolution without parabolic points in 3-Euclidean space $\mathbb{R}^3$, satisfying the condition ${\Delta}^{II}G=f(G+C)$, where ${\Delta}^{II}$ is the Laplace operator with respect to the second fundamental form, $f$ is a smooth function on the surface and C is a constant vector. Our main results state that surfaces of revolution without parabolic points in $\mathbb{R}^3$ which satisfy the condition ${\Delta}^{II}G=fG$, coincide with surfaces of revolution with non-zero constant Gaussian curvature.

대칭분 전압 단위 벡터를 이용한 송전선로 보호용 고장상 선택 알고리즘 (Fault Phase Selection Algorithm using Unit Vector of Sequence Voltages for Transmission Line Protection)

  • 이명수;이재규;김수남;유석구
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권9호
    • /
    • pp.460-466
    • /
    • 2002
  • A reliable fault phase selection algorithm plays a very important role in transmission line protection, Particularly in Extra High Voltage (EHV) networks. The conventional fault phase selection algorithm used the phase difference between positive and negative sequence current excluding load current. But, it is difficult to pick out only fault current since we can not know when a fault occurs and select the fault phase in weak-infeed conditions that dominate zero-sequence current in phase current. The proposed algorithm can select the accurately fault phase using the sum of unit vectors which are calculated by positive-sequence voltage and negative-sequence voltage.

계통 연계형 태양광 발전 시스템의 위상 동기화를 위한 디지털 PLL 제어 (Digital PLL Control for Phase-Synchronization of Grid-Connected PV System)

  • 김용균;최종우;김흥근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권9호
    • /
    • pp.562-568
    • /
    • 2004
  • The frequency and phase angle of the utility voltage are important in many industrial systems. In the three-phase system, they can be easily known by using the utility voltage vector. However, in the case of single phase system, there are some difficulties in detecting the information of utility voltage. In conventional system, the zero-crossing detection method is widely used, but could not obtain the information of utility voltage instantaneously. In this paper, the new digital PLL control using virtual two phase detector is proposed with a detailed analysis of single-phase digital PLL control for utility connected systems. The experimental results under various utility conditions are presented and demonstrate an excellent phase tracking capability in the single-phase grid-connected operation.

Direct Search Methods for Nonlinear Optimization Problem used ART Theory

  • 손준혁;서보혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1830-1831
    • /
    • 2006
  • In this paper, the search is conducted along each of the coordinate directions for finding the minimum. If $e_i$ is the unit vector along the coordinate direction i, we determine the value a, minimizing f(a)= $f(x+ae_i)$, where a is a real number. A move is made to the new point $x+a_ie_i$ at the end of the search along the direction i. In an n dimensional problem, we define the search along all the directions as one stage. The function value at the end of the stage is compared to the value at the beginning of the stage in establishing the convergence. The gradient appears to be zero at point. We can safeguard this by introducing an acceleration step of one additional step along the pattern direction developed by moves along the coordinate directions.

  • PDF

배전선로 장주의 중성선 전류 계산 (Neutral Current Calculation of Electric Pole in Distribution Line)

  • 서훈철;김철환;정창수;유연표;이천원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.87-89
    • /
    • 2005
  • If the three phases are not balanced, the current in neutral line is not zero. Then, the induced voltage can be generated In communication line. The KEPCO's rule about unbalanced current in single electric pole is a twenty percent of phase current. But the unbalanced current in double electric pole can't decide the rule because there are many different views. This paper develops the calculation and analysis technique of neutral current in single electric pole and double electric pole using equivalent circuit analysis, vector analysis and EMTP simulation.

  • PDF

Comparison of the harmonic reduction by using harmonic passive fitters and technique of intervene firing method at the pulse of the 6-pulse phase controlled converter.

  • Wongtongdee, Surached W.;Laohasongkram, Pipat
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.782-785
    • /
    • 2005
  • This article introduces technique to reduce harmonic by using the $5^{th}$ and $7^{th}$ harmonic tune filter and line reactor in the comparison to the technique of intervening firing method at the pulse of the 6-pulse phase-controlled converter in every 1/6 period. The design of the technique introduced in this article is to reduce the harmonic distortion of the current and the voltage resulted from three-phase thyristor phase-controlled converter. The waveform obtained from the experiment was analyzed on the spectrum of the current, voltage and the total harmonic distortion. The double firing method causes zero vectors of output voltage and input current. Designing the mechanism of the converter based on the idea of Park Vector Theory, the number of harmonic distortion in the intervening firing method were compared to those in normal firing method.

  • PDF

CASTELNOUVO-MUMFORD REGULARITY OF GRADED MODULES HAVING A LINEAR FREE PRESENTATION

  • Ahn, Jeaman
    • 충청수학회지
    • /
    • 제22권4호
    • /
    • pp.777-787
    • /
    • 2009
  • In this paper we investigate the upper bound on the Castelnuovo-Mumford regularity of a graded module with linear free presentation. Let M be a finitely generated graded module over a polynomial ring R with zero dimensional support. We prove that if M is generated by elements of degree $d{\geq}0$ with a linear free presentation $$\bigoplus^p{R}(-d-1)\longrightarrow^{\phi}\bigoplus^q{R}(-d){\longrightarrow}M{\longrightarrow}0$$, then the Castelnuovo-Mumford regularity of M is at most d+q-1. As an important application, we can prove vector bundle technique, which was used in [11], [13], [17] as a tool for obtaining several remarkable results.

  • PDF