• Title/Summary/Keyword: Zero-profile

Search Result 120, Processing Time 0.023 seconds

A New High Efficiency and Low Profile On-Board DC/DC Converter for Digital Car Audio Amplifiers

  • Kim Chong-Eun;Han Sang-Kyoo;Moon Gun-Woo
    • Journal of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.83-93
    • /
    • 2006
  • A new high efficiency and low profile on-board DC/DC converter for digital car audio amplifiers is proposed. The proposed converter shows low conduction loss due to the low voltage stress of the secondary diodes, a lack of DC magnetizing current for the transformer, and a lack of stored energy in the transformer. Moreover, since the primary MOSFETs are turned-on under zero-voltage-switching (ZVS) conditions and the secondary diodes are turned-off under zero-current-switching (ZCS) conditions, the proposed converter has minimized switching losses. In addition, the input filter can be minimized due to a continuous input current, and an output inductor is absent in the proposed converter. Therefore, the proposed converter has the desired features, high efficiency and low profile, for a viable power supply for digital car audio amplifiers. A 60W industrial sample of the proposed converter has been implemented for digital car audio amplifiers with a measured efficiency of $88.3\%$ at nominal input voltage.

Cervical Stand-Alone Polyetheretherketone Cage versus Zero-Profile Anchored Spacer in Single-Level Anterior Cervical Discectomy and Fusion : Minimum 2-Year Assessment of Radiographic and Clinical Outcome

  • Cho, Hyun-Jun;Hur, Junseok W.;Lee, Jang-Bo;Han, Jin-Sol;Cho, Tai-Hyoung;Park, Jung-Yul
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.2
    • /
    • pp.119-124
    • /
    • 2015
  • Objective : We compared the clinical and radiographic outcomes of stand-alone polyetheretherketone (PEEK) cage and Zero-Profile anchored spacer (Zero-P) for single level anterior cervical discectomy and fusion (ACDF). Methods : We retrospectively reviewed 121 patients who underwent single level ACDF within 2 years (Jan 2011-Jan 2013) in a single institute. Total 50 patients were included for the analysis who were evaluated more than 2-year follow-up. Twenty-nine patients were allocated to the cage group (m : f=19 : 10) and 21 for Zero-P group (m : f=12 : 9). Clinical (neck disability index, visual analogue scale arm and neck) and radiographic (Cobb angle-segmental and global cervical, disc height, vertebral height) assessments were followed at pre-operative, immediate post-operative, post-3, 6, 12, and 24 month periods. Results : Demographic features and the clinical outcome showed no difference between two groups. The change between final follow-up (24 months) and immediate post-op of Cobb-segmental angle (p=0.027), disc height (p=0.002), vertebral body height (p=0.033) showed statistically better outcome for the Zero-P group than the cage group, respectively. Conclusion : The Zero-Profile anchored spacer has some advantage after cage for maintaining segmental lordosis and lowering subsidence rate after single level anterior cervical discectomy and fusion.

Comparative Study of Clinical and Radiological Outcomes of a Zero-Profile Device Concerning Reduced Postoperative Dysphagia after Single Level Anterior Cervical Discectomy and Fusion

  • Son, Doo Kyung;Son, Dong Wuk;Kim, Ho Sang;Sung, Soon Ki;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.56 no.2
    • /
    • pp.103-107
    • /
    • 2014
  • Objective : This study analyzed clinical and radiological outcomes of a zero-profile anchored spacer (Zero-P) and conventional cage-plate (CCP) for single level anterior cervical discectomy and fusion (ACDF) to compare the incidence and difference of postoperative dysphagia with both devices. Methods : We retrospectively reviewed our experiences of single level ACDF with the CCP and Zero-P. From January 2011 to December 2013, 48 patients who had single level herniated intervertebral disc were operated on using ACDF, with CCP in 27 patients and Zero-P in 21 patients. Patients who received more than double-level ACDF or combined circumferential fusion were excluded. Age, operation time, estimated blood loss (EBL), pre-operative modified Japanese Orthopaedic Association (mJOA) scores, post-operative mJOA scores, achieved mJOA scores and recovery rate of mJOA scores were assessed. Prevertebral soft tissue thickness and postoperative dysphagia were analyzed on the day of surgery, and 2 weeks and 6 months postoperatively. Results : The Zero-P group showed same or favorable clinical and radiological outcomes compared with the CCP group. Postoperative dysphagia was significantly low in the Zero-P group. Conclusions : Application of Zero-P may achieve favorable outcomes and reduce postoperative dysphagia in single level ACDF.

Zero Placement of the Asymmetric S-curve Profile to Minimize the Residual Vibration (잔류진동 저감을 위한 비대칭 S-curve 프로파일의 영점 배치법)

  • Ha, Chang-Wan;Rew, Keun-Ho;Kim, Kyung-Soo;Kim, Soo-Hyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.4
    • /
    • pp.308-313
    • /
    • 2012
  • Robust tuning rules of the motion profile are proposed to minimize the residual vibration. For asymmetric S-curve profile, tuning rules are analytically formulated using Laplace-domain approach. When the system modeling is known exactly, by placing a single zero of the motion profile on the pole of the system, the residual vibration can be perfectly eliminated under undamped system. However, if there are some amounts of the modeling errors, the residual vibration significantly increases. To track this issue, the robust tuning rules against modeling error are discussed. One of the proposed robust tuning rules is placing the multiple zeros of the motion profile on the pole of the system, and the other is placing the zeros of the motion profile around the pole of the system. Thanks to the proposed robust tuning rules, motion profile becomes more robust to modeling errors while minimizing the residual vibration. By simulation, the effectiveness of the proposed robust tuning rules is verified.

EXACT SOLUTION FOR STEADY PAINT FILM FLOW OF A PSEUDO PLASTIC FLUID DOWN A VERTICAL WALL BY GRAVITY

  • Alam, M.K.;Rahim, M.T.;Islam, S.;Siddiqui, A.M.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.16 no.3
    • /
    • pp.181-192
    • /
    • 2012
  • Here in this paper, the steady paint film flow on a vertical wall of a non-Newtonian pseudo plastic fluid for drainage problem has been investigated. The exact solution of the nonlinear problem is obtained for the velocity profile. Also the average velocity, volume flux, shear stress on the wall, force to hold the wall in position and normal stress difference have been derived. We retrieve Newtonian case, when material constant ${\mu}_1$ and relaxation time ${\lambda}_1$ equal zero. The results for co-rotational Maxwell fluid is also obtained by taking material constant ${\mu}_1$ = 0. The effect of the zero shear viscosity ${\eta}_0$, the material constant ${\mu}_1$, the relaxation time ${\lambda}_1$ and gravitational force on the velocity profile for drainage problem are discussed and plotted.

The Image Changes in the Control Panelipse Radiography by the Control of the Profile Index (Profile Index에 따른 Panelipse Ⅱ 방사선 상층의 변화)

  • Cho Chul-Ho;Sung Jae-Hyun
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.1
    • /
    • pp.71-78
    • /
    • 1990
  • This research was made to investigate the change of the image layer and of the vertical and horizontal magnification on the Panelipse radiographic image by the control of profile index. Using the Panelipse, a series of 60 exposures were taken with the steel balls placed in the holes of the plastic model plate, and then evaluated by 4 observers. Two points were assigned for a reading of sharp, one for middling sharp, and zero for unsharp. Each ball image then could be given a total reader score of 0 to 8. The author analyzed the image layer as defined by a sharpness score of 6 or more. The results obtained were as follows: As the profile index was increased, the shape of the image layer was not changed, and the width of the image layer was increased, and the position of the layer shifted away from the rotation center. As the profile index was increased, the ranges of vertical and horizontal magnification was increased, especially the ranges of horizontal magnification was greater than that of vertical magnification.

  • PDF

THE MASS PROFILE OF ABELL 1689 FROM A LENSING ANALYSIS OF DEEP WIDE FIELD SUBARU IMAGES

  • UMETSU KEIICHI;BROADHURST TOM;TAKADA MASAHIRO;KONG Xu
    • Journal of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.191-195
    • /
    • 2005
  • We used Subaru observations of A1689 (z = 0.183) to derive an accurate, model-independent mass profile for the entire cluster, r$\le$2Mpc/h, by combining magnification bias and distortion measurements. The projected mass profile steepens quickly with increasing radius, falling away to zero at r${\~}$1.0Mpc/h, well short of the anticipated virial radius. Our profile accurately matches onto the inner profile, r $\le$200kpc/ h, derived from deep HST / ACS images. The combined ACS and Subaru information is well fitted by an NFW profile with virial mass, $(1.93 \pm 0.20) {\times}10^{15} M_{\bigodot}$, and surprisingly high concentration, $C_{vir} = 13.7^{+1.4}_{-1.1}$, significantly larger than theoretically expected ($C_{vir} {\le}4$), corresponding to a relatively steep overall profile. These results are based on a reliable sample of background galaxies selected to be redder than the cluster E/SO sequence. By including the faint blue galaxy population a much smaller distortion signal is found, demonstrating that blue cluster members significantly dilute the true signal for r $\le$ 400kpc/ h. This contamination is likely to affect most weak lensing results to date.

Preparation and In vitro Release Characteristics of Hydrophilic Albumin Microspheres Containing Methotrexate and Methotrexate-Human Serum Albumin Conjugates

  • Hwang, Sung-Joo;Lee, Myung-Gulll;Kim, Chong-Kook
    • Archives of Pharmacal Research
    • /
    • v.15 no.2
    • /
    • pp.162-168
    • /
    • 1992
  • Release characteristics of five different types of hydrophilic albumin microspheres (HAM) containing different ratios of methotrexate-albumin (MTX-HSA) conjugates to free MTX: 1 : 0 (HAMC), 3 :1 (HAMC 3F), 1 :1 (HAMCF), 1:3 (HAMCF3) and 0 : 1 (HAMF) were investigated in the absence or presence of protease using dissolution tester. In all the HAMs studied except HAMC, the MTX was released bi-exponentially in the absence of protease; an initial fast release period up to approximately 6h, and thereafter the release rate was very much slower. The fast release of MTX from the HAMs (such as HAMC3F, HAMCF, HAMCF3 and HAMF) at the initial phase in probably due to the release of "physically associated" MTX from the core of the HAMs. The initial rate constants were 7.2, 8.7, 8.5 and 5.9 times greater than the second rate constants for HAMF, HAMCF3, HAMCF and HAMC3F, respectively. MTX release from HAMC was very slow and mono-phasic. It was at most 2.2% of the total entrapped amount by 24 h. The protease accelerated the release of MTX from the HAMs. The percentages of MTX released from HAMs up to 24 h were 100, 89.0, 75.0, 66.0 and 61.0% for HAMF, HAMCF3, HAMCF, HAMC3F and HAMC, respectively in the presence of protease and the corresponding values in the absence of protease were 30.2 19.0, 10.0, 6.5 and 2.2%, respectively. In vitro release of MTX in the presence of protease varied according to the ratios of MTX-HSA conjugates to MTX; the data set from HAMF, HAMCF3 and HAMCF fits better to monophasic first-order profile more adequately than to zero-order profile, that of HAMC3 monophasic first-order, and that of HAMC to bi-phasic zero-order. Above results suggested that zero-order release rate can be achieved by adjusting the ratio of MTX-HSA conjugates to MTX in the preparation of HAMs such as HAMC3F.as HAMC3F.

  • PDF

Development of Low Cost, High-Performance Miniaturized Lithium-ion Battery Tester Using Raspberry Pi Zero

  • La, Phuong-Ha;Im, Hwi-Yeol;Choi, Sung-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2017.11a
    • /
    • pp.47-48
    • /
    • 2017
  • This paper presents a low-cost portable lithium battery parameter measuring and estimating the solution. In this method, lithium battery characteristics are monitored during discharging and charging cycles. The battery profile is analyzed, and its key parameters are estimated by GNU Octave running on Raspberry Pi Zero, a mini computer. The proposed method can measure and estimate the battery parameters for SOC and DOD estimation with reasonable accuracy as well as portability features.

  • PDF

Optimisation of a novel trailing edge concept for a high lift device

  • Botha, Jason D.M.;Dala, Laurent;Schaber, S.
    • Advances in aircraft and spacecraft science
    • /
    • v.2 no.3
    • /
    • pp.329-343
    • /
    • 2015
  • This study aimed to observe the effect of a novel concept (referred to as the flap extension) implemented on the leading edge of the flap of a three element high lift device. The high lift device, consisting of a flap, main element and slat is designed around an Airbus research profile for sufficient take off and landing performance of a large commercial aircraft. The concept is realised on the profile and numerically optimised to achieve an optimum geometry. Two different optimisation approaches based on Genetic Algorithm optimisations are used: a zero order approach which makes simplifying assumptions to achieve an optimised solution: as well as a direct approach which employs an optimisation in ANSYS DesignXplorer using RANS calculations. Both methods converge to different optimised solutions due to simplifying assumptions. The solution to the zero order optimisation showed a decreased stall angle and decreased maximum lift coefficient against angle of attack due to early stall onset at the flap. The DesignXplorer optimised solution matched that of the baseline solution very closely. The concept was seen to increase lift locally at the flap for both optimisation methods.