• Title/Summary/Keyword: Zero vector

Search Result 301, Processing Time 0.036 seconds

A Two-Phase Separately Randomized Pulse Position PWM Technique with Double-Zero Vector Mode (2중 영 벡터 모드를 갖는 2상 개별 펄스 위치 변조기법)

  • Kim Jung-Geun;Oh Seung-Yeol;Jung Young-Gook;Lim Young-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.12
    • /
    • pp.739-750
    • /
    • 2004
  • In case while M(modulation index) is more than 0.7, the spectrum of motor voltage and current of a conventional two-phase SRP-PWM scheme are not reduced considerably. To solve the problems of a conventional two-phase SRP-PWM, this paper proposes a two-phase SRP-PWM(DZSRP-PWM) with double zero vector mode which zero vector is selected as V(111) in case of M >0.7, and zero vector is selected as V(000) if M < 0.7. For the validity of the proposed method, the PSIM simulations and experiments were achieved. And the simulation and experiment results show that the voltage and current harmonics all over the modulation index are spread to a wide band area.

Analysis of Capacitor Voltage and Boost Vector in Neutral-Point-Clamped and H-Bridge Converter (NPC와 H-Bridge 컨버더의 부스트 벡터와 커패시터 전압의 해석)

  • 김정균;김태진;강대욱;현동석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.274-284
    • /
    • 2003
  • Multi-level converter that is high-capacity electric power conversion system is used widely to electric motor drive system and FATCs(Flexible AC Transmission Systems). H-Bridge converter has been prevalently applied to shunt-type system because it can be easily expanded to the multi-level. In steady states, converter is normally operated in the range of 0.7∼0.8 of modulation Index. Even though zero vectors are not imposed to high modulation index, DC-Link voltage Is constant. It means that converter has another boost vector except for zero vectors among several vectors in 3-level converter. This paper has examined the principle of boost vector and investigated the difference between another boost vector and zero vectors in 3-level converter. In addition, this paper has analysed and compared the charging currents and the capacitor voltages of two topologies. The currents and voltages are related to reference voltage. Therefore, it proposed the calculation method for the voltage ripple and the charging current of each capacitor and compared various DC-Link voltage control methods through the simulation.

Optimal Zero Vector Selecting Method to Reduce Switching Loss on Model Predictive Control of VSI (전압원 인버터의 모델 예측 제어에서 스위칭 손실을 줄이기 위한 최적의 제로 벡터 선택 방법)

  • Park, Jun-Cheol;Park, Chan-Bae;Baek, Jei-Hoon;Kwak, Sang-Shin
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.3
    • /
    • pp.273-279
    • /
    • 2015
  • A zero vector selection method to reduce switching losses for model predictive control (MPC) of voltage source inverter is proposed. A conventional MPC of voltage source inverter has not been proposed, and a method to select the redundancy of the zero vector is required for this study. In this paper, the redundancy of the zero vectors is selected with generating a zero sequence voltage to reduce switching losses. The zero vector of 2-level inverter is determined by determining sign of the zero sequence voltage. In the proposed method, the quality of the current is retained and switching loss can be reduced compared with the conventional method. This result was verified by P-sim simulation and experiments.

Switching Noise and Conducted Noise of Two-Phase Space Vector SRP based Induction Motor Drives with Double Zero Vector Modes (2중 영벡터 모드를 갖는 2상 공간벡터 SRP기반 유도모터 구동시스템의 스위칭 소음과 전도 노이즈)

  • Kim, J.G.;Lim, Y.C.;Jung, Y.G.
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.109-113
    • /
    • 2004
  • In case while modulation index (M) is more than 0.7, the spectrum of motor voltage and current of a conventional two-phase SRP scheme are not reduced considerably. To solve the problems of a conventional two-phase SRP, this paper proposes a two-phase SRP(DZSRP) with double zero vector mode which zero vector is selected as V(111) in case of M $\geq$ 0.7, and zero vector is selected as V(000) if M < 0.7. For the validity of the proposed method, a 16 bit micro-controller C167 was used and the experiments were conducted with the 1.5kw induction motor under load condition. And the experimental results show that the switching noise spectrum for all the M are spread to a wide band area. Also the switching noise and conducted noise are discussed.

  • PDF

Direct Torque Control Method of Induction Machine with Constant Average Torque (일정한 토크 평균치를 가지는 유도전동기 직접토크제어기법)

  • Kim, Jeong-Ok;Jo, Nae-Su;Choe, Byeong-Tae;Kim, U-Hyeon;Im, Seong-Un;Gwon, U-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.31-34
    • /
    • 2003
  • There are several types of switching table for selection voltage vector in direct torque control of induction motor. In general, two-quadrant and four-quadrant operation switching table are used mostly. Two-quadrant operation has an advantage that reduced the torque ripples in comparison with four-quadrant operation, but it has the defect that is not constant average torque. Because the torque increasing slope size by non-zero voltage vector is different from the torque decreasing slope size by zero voltage vector as speed region. The main objective of this study is to maintain constant average torque using two-quadrant operation switching table. In proposed method, the torque increasing slope or decreasing slope are calculated before selected voltage vector is applied. Then, it is applied to zero voltage vector or non-zero voltage vector until the torque increasing slope and decreasing slope are equal. In total magnitude. Therefore it becomes to maintain average torque at whole operation speed. The validity of the proposed method is proven by simulated and experimental results.

  • PDF

Switching Noise Spectrum of 2-Phase SRP-PWM Based Inverter Fed Drives with Double Zero Vector Mode (2중 영 벡터 모드의 2상 SRP-PWM기반 인버터 구동장치의 스위칭 소음 스펙트럼)

  • Kim J. G.;Oh S. Y.;Lim Y. C.;Jung Y. G.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.283-288
    • /
    • 2004
  • In case while modulation index (M) is more than 0.7, the spectrum of motor voltage and current of a conventional two-phase SRP scheme are not reduced considerably. To solve the problems of a conventional two-phase SRP, this paper proposes a two-phase SRP(DZSRP) with double zero vector mode which zero vector is selected as V(111) in case of $M\;\geqq\;0.7$, and zero vector is selected as V(000) if M < 0.7. For the validity of the proposed method, a 16 bit micro-controller C167 was used and the experiments were conducted with the 1.5kw induction motor under load condition. And the experimental results show that the switching noise spectrum for all the M are spread to a wide band area.

  • PDF

Feasible Power Loss Analysis and Estimation of Auxiliary Resonant DC Link Assisted Soft-Switching Inverter with New Zero Vector Generation Method

  • Manabu Kurokawa;Claudio Y. Inaba;M. Rukonuzzaman;Eiji Hiraki;Yoshihiro Konishi;Mutsuo Nakaoka
    • Journal of Power Electronics
    • /
    • v.2 no.2
    • /
    • pp.77-87
    • /
    • 2002
  • The purpose of this paper is to improve power conversion efficiency of three-phase soft-switching voltage-source inverter with an auxiliary resonant dc link (ARDCL) snubber circuit. Firstly, the operation principle of ARDCL snubber circuit is described. Secondly, this paper proposes an effictive generation method of zero voltage vector for three-phase voltage-source soft-switching inverter in power losses in which power losses in the ARDCL snubber circuit can be reduced. In particular, zero voltage holding interval in the inverter DC busline can be controlled due to the new generation scheme of zero voltage vector. Thirdly, a simulator for power loss analysis for power loss characteristics based on actual system, is developed. the validity of developed. The validity of developed simulator of proved with experimental results. Finally, power efficency of three-phase inverter is estimated according to high carrier frequency by using the simulatior.

AN EINSTEIN'S CONNECTION WITH ZERO TORSION VECTOR IN EVEN-DIMENSIONAL UFT Xn

  • Lee, Jong Woo
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.24 no.4
    • /
    • pp.869-881
    • /
    • 2011
  • The main goal in the present paper is to obtain a necessary and sufficient condition for a new connection with zero torsion vector to be an Einstein's connection and derive some useful representation of the vector defining the Einstein's connection in even-dimensional UFT $X_n$.

Analysis and modelling of the large capacity multilevel H-bridge inverter using Space vector modulation (Space vector modulation을 이용한 대용량 멀티 레벨 H-bridge 인버터의 해석 및 모델링)

  • Kim H.J.;Jeong S.G.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.5-9
    • /
    • 2003
  • Conventional variable-speed Induction motor drives with inverters are subject to detrimental effect of zero-sequence voltages, such a shaft voltage and bearing current. This paper presents a way of the suppression of the zero-sequence components in multilevel H-bridge inverters. First examined Is the inherent zero-sequence characteristic of the conventional subharmonic PW method. Then it is shown that the zero-sequence voltage can be eliminated with proper -selection of switching states with space vector modulation. Although this method alone restricts the linear modulation range of control, a combination of the proposed method and the minimum switching method appears to be effective in suppressing the zero-sequence voltage to minimum level while maintaining the linear control range.

  • PDF

FRACTIONAL ORDER SOBOLEV SPACES FOR THE NEUMANN LAPLACIAN AND THE VECTOR LAPLACIAN

  • Kim, Seungil
    • Journal of the Korean Mathematical Society
    • /
    • v.57 no.3
    • /
    • pp.721-745
    • /
    • 2020
  • In this paper we study fractional Sobolev spaces characterized by a norm based on eigenfunction expansions. The goal of this paper is twofold. The first one is to define fractional Sobolev spaces of order -1 ≤ s ≤ 2 equipped with a norm defined in terms of Neumann eigenfunction expansions. Due to the zero Neumann trace of Neumann eigenfunctions on a boundary, fractional Sobolev spaces of order 3/2 ≤ s ≤ 2 characterized by the norm are the spaces of functions with zero Neumann trace on a boundary. The spaces equipped with the norm are useful for studying cross-sectional traces of solutions to the Helmholtz equation in waveguides with a homogeneous Neumann boundary condition. The second one is to define fractional Sobolev spaces of order -1 ≤ s ≤ 1 for vector-valued functions in a simply-connected, bounded and smooth domain in ℝ2. These spaces are defined by a norm based on series expansions in terms of eigenfunctions of the vector Laplacian with boundary conditions of zero tangential component or zero normal component. The spaces defined by the norm are important for analyzing cross-sectional traces of time-harmonic electromagnetic fields in perfectly conducting waveguides.