• Title/Summary/Keyword: Zero IF

Search Result 691, Processing Time 0.029 seconds

A Two-Phase Separately Randomized Pulse Position PWM Technique with Double-Zero Vector Mode (2중 영 벡터 모드를 갖는 2상 개별 펄스 위치 변조기법)

  • Kim Jung-Geun;Oh Seung-Yeol;Jung Young-Gook;Lim Young-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.12
    • /
    • pp.739-750
    • /
    • 2004
  • In case while M(modulation index) is more than 0.7, the spectrum of motor voltage and current of a conventional two-phase SRP-PWM scheme are not reduced considerably. To solve the problems of a conventional two-phase SRP-PWM, this paper proposes a two-phase SRP-PWM(DZSRP-PWM) with double zero vector mode which zero vector is selected as V(111) in case of M >0.7, and zero vector is selected as V(000) if M < 0.7. For the validity of the proposed method, the PSIM simulations and experiments were achieved. And the simulation and experiment results show that the voltage and current harmonics all over the modulation index are spread to a wide band area.

개인 휴대 단말 시스템용 표면 탄성파 필터의 동향

  • 이만형
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.3
    • /
    • pp.41-49
    • /
    • 2003
  • 본 고에서는 휴대 이동단말 시스템의 복합다기능화 및 단말기내 적용되는 주파수 변조 방식의 변화에 따른 핵심부품으로서 표면탄성파필터의 요구 성능의 변화 및 그에 따른 대응방향에 대해서 설명하고 있다. 현재 전세계적으로 널리 보급되고 있는 코드분할다중접속방식(CDMA)의 이동단말기에서는 수퍼헤테로다인 변복조방식의 적용에 따라 표면탄성파 소자로서 듀플렉서, 송신 RF 필터, 수신 RF 필터 및 수신 IF 필터 등이 적용되어 왔다. 하지만 최근 들어 RF 대역에서 기저대역으로 신호의 직접변환(Direct Conversion)이 가능한 Chipset의 보급과 더불어 급속히 Zero-IF화가 추진되고 있으며, 그에 따라 RE 필터부의 고성능화가 요구되고 있다. Zero-IF Chipset은 신호대 잡음비를 크게 하기 위해서 수신 RE 필터에 있어서 Balance 구동을 기본으로 하고 있으며, 듀플렉서에 있어서는 통과대역의 저손실화, 저지대역의 고감쇠화 및 송수신간 높은 격리도를 요구하고 있다. 본 고에서는 이러한 요구사항을 만족시킬 수 있는 표면탄성파 필터의 구현 원리와 향후 동향에 대해 논의하였다.

A Laxity Based On-line Real-Time Scheduling Algorithm for Multiprocessor Systems (다중프로세서 시스템을 위한 여유시간 기반의 온라인 실시간 스케줄링 알고리즘)

  • Cho, Kyu-Eok;Kim, Yong-Seok
    • The KIPS Transactions:PartA
    • /
    • v.16A no.6
    • /
    • pp.437-442
    • /
    • 2009
  • For multiprocessor systems, Earliest Deadline First (EDF) based on deadline and Least Laxity First (LLF) based on laxity are not suitable for practical environment since EDF has low schedulability and LLF has high context switching overhead. As a combining of EDF and LLF to improve the performance, Earliest Deadline Zero Laxity (EDZL) was proposed. EDZL is basically the same as EDF. But if the laxity of a task becomes zero, its priority is promoted to the highest level. In this paper, we propose Least Laxity Zero Laxity (LLZL) which is based on LLF. But context switching is allowed only if the laxity of a task on rady queue becomes zero. Simulation results show that LLZL has high schedulability approaching to LLF and low context switching overhead similar to EDF. In comparison with EDZL, LLZL has better performance in both of schedulability and context switching overhead.

The Analysis of Zero Sequence Components in Dynamic Voltage Restorer System (영상성분을 고려한 DVR 기기 해석)

  • Jeong, Il-Yeop;Park, Sang-Yeong;Won, Dong-Jun;Mun, Seung-Il;Park, Jong-Geun;Han, Byeong-Mun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.4
    • /
    • pp.169-174
    • /
    • 2002
  • The magnitude and phase of the compensating voltage in Dynamic Voltage Restorer (DVR) system depend on the voltage sag in the phases affected by the fault and on the influence of the zero sequence components. If the delta connection of the transformer is used, the zero sequence components do not appear on the load side. But nowadays, Y connected transformers with grounded neutral, that is 3-phase 4-wire system, are usually used. Therefore the zero-sequence components are occurred during faults. The zero-sequence components result in the high insulation costs and the asymmetry of the phase and magnitude of the terminal voltages. In this paper 3 phase 4 wire distribution system and 3 phase 3 wire system are analyzed and characteristics of voltage sag are presented. And this paper proposes the method that can mitigate the zero-sequence under the unbalance faults causing voltage sage and phase angle iumps.

Design of the Zero Location for Minimizing the Peak Overshoot of Second-Order Discrete Systems (이차 이산 시스템의 Peak Overshoot을 최소화하기 위한 영점의 위치 설계)

  • Lee, Jae-Seok;Chung Tae-Sang
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.51 no.11
    • /
    • pp.483-493
    • /
    • 2002
  • The damping ratio ${\xi}$ of the unit-step response of a second-order discrete system is a function of only the location of the closed-loop poles and is not directly related to the location of the system zero. However, the peak overshoot of the response is the function of both the damping ratio ${\xi}$ and an angle ${\alpha}$, which is the phasor angle of the damped sinusoidal response and is determined by the relative location of the zero with respect to the closed-loop poles. Therefore, if the zero and the open-loop poles are relatively adjusted, through pole-zero cancellation, to maintain the desired (or designed) closed-loop poles, the damping ratio ${\xi}$ will also be maintained, while the angle ${\alpha}$ changes. Accordingly, when the closed-loop system poles are fixed, the peak overshoot is considered as a function of the angle ${\alpha}$ or the system zero location. In this paper the effects of the relative location of the zero on the system performance of a second-order discrete system is studied, and a design method of digital compensator which achieves a minimum peak overshoot while maintaining the desired system mode and the damping ratio of the unit step response is presented.

FOURIER INVERSION OF DISTRIBUTIONS ON THE SPHERE

  • A, Francisco Javier Gonzalez Vieli
    • Journal of the Korean Mathematical Society
    • /
    • v.41 no.4
    • /
    • pp.755-772
    • /
    • 2004
  • We show that the Fourier-Laplace series of a distribution on the sphere is uniformly Cesaro-summable to zero on a neighborhood of a point if and only if this point does not belong to the support of the distribution. Similar results on the ball and on the real projective space are also proved.

Design of Butterfly Valve Disk to Minimize Interference at Opening and Closing (개폐 시 최소 간섭을 갖는 버터플라이 밸브 디스크의 설계)

  • Choi Young;Boo Kwangsuk;Yeo Hong-Tae;Hur Kwando;Kim Hokwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.12
    • /
    • pp.140-145
    • /
    • 2004
  • In this study, the design and analysis of a butterfly valve disk was performed to minimize the rubbing between the disk and the seat at opening and closing. The butterfly valve has double eccentric structure and the contact surface between the disk and the seat is a conical surface. At the instant of opening and closing the valve by the rotation of disk, the positions of zero contact point are changed. Also, if the cone surface is cut in the perpendicular direction to the rotation axis of the valve, the contour of cutting section is hyperbolic. Therefore minimum distance between the origin of the eccentric axis and the hyperbolic curve goes to the position of zero contact point. In order to consider the interferences between the disk and the seat, the thermal-structure coupled field analysis was performed by ANSYS.

ON JORDAN AND JORDAN HIGHER DERIVABLE MAPS OF RINGS

  • Liu, Lei
    • Bulletin of the Korean Mathematical Society
    • /
    • v.57 no.4
    • /
    • pp.957-972
    • /
    • 2020
  • Let 𝓡 be a 2-torsion free unital ring containing a non-trivial idempotent. An additive map 𝛿 from 𝓡 into itself is called a Jordan derivable map at commutative zero point if 𝛿(AB + BA) = 𝛿(A)B + B𝛿(A) + A𝛿(B) + 𝛿(B)A for all A, B ∈ 𝓡 with AB = BA = 0. In this paper, we prove that, under some mild conditions, each Jordan derivable map at commutative zero point has the form 𝛿(A) = 𝜓(A) + CA for all A ∈ 𝓡, where 𝜓 is an additive Jordan derivation of 𝓡 and C is a central element of 𝓡. Then we generalize the result to the case of Jordan higher derivable maps at commutative zero point. These results are also applied to some operator algebras.

Switching Noise Spectrum of 2-Phase SRP-PWM Based Inverter Fed Drives with Double Zero Vector Mode (2중 영 벡터 모드의 2상 SRP-PWM기반 인버터 구동장치의 스위칭 소음 스펙트럼)

  • Kim J. G.;Oh S. Y.;Lim Y. C.;Jung Y. G.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.283-288
    • /
    • 2004
  • In case while modulation index (M) is more than 0.7, the spectrum of motor voltage and current of a conventional two-phase SRP scheme are not reduced considerably. To solve the problems of a conventional two-phase SRP, this paper proposes a two-phase SRP(DZSRP) with double zero vector mode which zero vector is selected as V(111) in case of $M\;\geqq\;0.7$, and zero vector is selected as V(000) if M < 0.7. For the validity of the proposed method, a 16 bit micro-controller C167 was used and the experiments were conducted with the 1.5kw induction motor under load condition. And the experimental results show that the switching noise spectrum for all the M are spread to a wide band area.

  • PDF