• Title/Summary/Keyword: Zero Crossing Detection

Search Result 75, Processing Time 0.029 seconds

Modeling and Application Research of Zero Crossing Detection Circuit (Zero Crossing Detection 회로 Modeling 및 응용연구)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.4
    • /
    • pp.143-148
    • /
    • 2020
  • In the case of a system that detects and controls the phase of an alternating voltage, the analog control method compensates the phase offset part by filtering for the detected phase and applies it to the control. However, in the digital control method, precise control cannot be achieved due to an error between the operating frequency of the microprocessor or the microcontroller and the input phase time when controlled using such phase detection. In general, when the method used is a certain time, the accumulated error is compensated and adjusted at random. To solve this problem, a method of detecting a zero point in real time and compensating for the operating frequency of the microprocessor is needed. Therefore, the research to be performed in this paper to reduce these errors and apply them to precise digital control is as follows. 1) Research on how to implement Zero Crossing Detection algorithm through simulation modeling to compensate the zero point to match the operating frequency through detection. 2) A study on the method of detecting zero points in real time through the Zero Crossing Detection design using a microcontroller and compensating for the operating frequency of the microprocessor. 3) A study on the estimation of the rotor position of BLDC motors using the Zero Crossing Detection circuit.

A frequency measurement based on modified zero-crossing method for anti-islanding detection of distributed generation (분산전원의 Anti-islanding용 수정된 zero-crossing 방식 주파수 검출기법)

  • Bae, Byung-Yeol;Baek, Seung-Taek;Lee, Jin-Hee;Suh, In-Young
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.634-636
    • /
    • 2008
  • This paper proposes a frequency detection method based on an advanced zero-crossing technique. Zero-crossing method for detecting frequency is one of the most widely used methods today. Although it is simple to apply, it requires extra hardware in implementation due to its limitations in accuracy. The proposed method models the error generated during zero crossing linearization and compensated for it in real time which makes it simple and accurate. The validity of the method and its applicability in anti-islanding detection of distributed generators was confirmed through simulation.

  • PDF

Zero Crossing Switching Method for PWM Converter in Rolling stock (철도차량 PWM Converter Zero Crossing 스위칭 기법)

  • Kim, Jin-Yong;Kim, Yen-Chung;Park, Sung-Ho
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.564-570
    • /
    • 2010
  • Last train of the vehicle for eht energy saving and improved performance PWM converters ares widely used. In the case of PWM converters by the zero detection system performance depends on whether it can be argued. Zero voltage detectio method of the hardware and software approach is to in this paper, the zero detection methods for hardware and software problems that have occured as a complemnetary technique was expained.

  • PDF

Fault Detection for Ceramic Heater in CVD Equipment using Zero-Crossing Rate and Gaussian Mixture Model (영교차율과 가우시안 혼합모델을 이용한 박막증착장비의 세라믹 히터 결함 검출)

  • Ko, JinSeok;Mu, XiangBin;Rheem, JaeYeol
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.2
    • /
    • pp.67-72
    • /
    • 2013
  • Temperature is a critical parameter in yield improvement for wafer manufacturing. In chemical vapor deposition (CVD) equipment, crack defect in ceramic heater leads to yield reduction, however, there is no suitable ceramic heater fault detection system for conventional CVD equipment. This paper proposes a short-time zero-crossing rate based fault detection method for the ceramic heater in CVD equipment. The proposed method measures the output signal ($V_{pp}$) of RF filter and extracts the zero-crossing rate (ZCR) as feature vector. The extracted feature vectors have a discriminant power and Gaussian mixture model (GMM) based fault detection method can detect fault in ceramic heater. Experimental results, carried out by measured signals provided by a CVD equipment manufacturer, indicate that the proposed method detects effectively faults in various process conditions.

Phase-extraction using Zero-Crossing detection in fiber-optic laser interferometry (영점검출을 이용한 광섬유형 레이저 간섭계의 위상추출)

  • Park, Hyoung-Jun;Lee, Jun-Ho;Song, Min-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.426-430
    • /
    • 2005
  • The fiber-optic interferometer which is a powerful application for nondestructive measurement techniques has many advantages such as capability of making portable system, easy optical arrangement, low optical loss. In spite of these advantages, this system has an environmental sensitivity of thermal drifts and vibrations. Against environmental perturbations and nonlinear characteristic of phase modulator, the accurate and fast ${\pi}/2$ phase stepping has been achieved by using zero-crossing detection. CCD camera trigger signal is generated at the 4 zero-crossing points. Our System has achieved up to 100 Hz of image capture speed and 0.6 mrad of accuracy of phase stepping, accuracy.

  • PDF

The Study on Detecting Scheme of Voltage Sag using the Two Difference Voltage (이중 차 전압을 이용한 전압 새그 검출 기법에 관한 연구)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.65-73
    • /
    • 2014
  • In this paper, the detection scheme of the voltage variation using a two difference voltage is proposed. The conventional sag detector is from a single-phase digital phase-locked loop (DPLL) that is based on a d-q transformation using an all-pass filter (APF). The APF generates a virtual q-axis voltage component with $90^{\circ}$ phase delay but the APF cannot generate the virtual q-axis voltage depending on the phase of the grid voltage. To overcome the problem, q-axis voltage component is generated from difference between the current and previous value of d-axis voltage component in the stationary reference frame. However, the difference voltage around the zero crossing is not enough to detect the voltage sag. Therefore, the new detection scheme using the two difference voltage which can detect the sag around the zero crossing voltage is proposed.

The Study on Sag Detecting Scheme around Zero Crossing Voltage for Single-Phase Inverter System (단상 인버터 시스템에서 영 전압 근처 전압 강하 검출 기법에 관한 연구)

  • Lee, Woo-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.96-104
    • /
    • 2014
  • The all pass filter generates a virtual q-axis voltage component with $90^{\circ}$ phase delay but the virtual q-axis voltage cannot detect the voltage depending on the phase of the grid voltage. To overcome the problem, q-axis voltage component is generated from difference between the current and previous value of d-axis voltage component in the stationary reference frame. However, the difference voltage between the current and previous value around the zero crossing voltage is not enough to detect the voltage sag. Therefore, the new detection scheme which can detect the sag around the zero crossing voltage is proposed.

Autocorrelation Coefficient for Detecting the Frequency of Bio-Telemetry

  • Nakajima, Isao;Muraki, Yoshiya;Yagi, Yukako;Kurokawa, Kiyoshi
    • Journal of Multimedia Information System
    • /
    • v.9 no.3
    • /
    • pp.233-244
    • /
    • 2022
  • A MATLAB program was developed to calculate the half-wavelength of a sine-curve baseband signal with white noise by using an autocorrelation function, a SG filter, and zero-crossing detection. The frequency of the input signal can be estimated from 1) the first zero-crossing (corresponding to ¼λ) and 2) the R value (the Y axis of the correlogram) at the center of the segment. Thereby, the frequency information of the preceding segment can be obtained. If the segment size were optimized, and a portion with a large zero-crossing dynamic range were obtained, the frequency discrimination ability would improve. Furthermore, if the values of the correlogram for each frequency prepared on the CPU side were prepared in a table, the volume of calculations can be reduced by 98%. As background, period detection by autocorrelation coefficients requires an integer multiple of 1/2λ (when using a sine wave as the object of the autocorrelation function), otherwise the correlogram drawn by R value will not exhibit orthogonality. Therefore, it has not been used in bio-telemetry where the frequencies move around.

A 3-Level Endpoint Detection Algorithm for Isolated Speech Using Time and Frequency-based Features

  • Eng, Goh Kia;Ahmad, Abdul Manan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1291-1295
    • /
    • 2004
  • This paper proposed a new approach for endpoint detection of isolated speech, which proves to significantly improve the endpoint detection performance. The proposed algorithm relies on the root mean square energy (rms energy), zero crossing rate and spectral characteristics of the speech signal where the Euclidean distance measure is adopted using cepstral coefficients to accurately detect the endpoint of isolated speech. The algorithm offers better performance than traditional energy-based algorithm. The vocabulary for the experiment includes English digit from one to nine. These experimental results were conducted by 360 utterances from a male speaker. Experimental results show that the accuracy of the algorithm is quite acceptable. Moreover, the computation overload of this algorithm is low since the cepstral coefficients parameters will be used in feature extraction later of speech recognition procedure.

  • PDF

A Simplified Analysis Approach on the Rotor Position Detection Error in Sensorless Interior Permanent Magnet Brushless DC Motor Drives (센서리스 매입형 영구자석 브러시리스 직류전동기 구동장치에서 단순화된 회전자 위치검출 오차 분석 방법)

  • Lee, Kwang-Woon;Park, Tae-Sik
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.5
    • /
    • pp.449-452
    • /
    • 2016
  • This paper presents a simplified analysis on the rotor position detection error in sensorless interior permanent magnet brushless DC motor (BLDCM) drives, wherein terminal voltage sensing based on the back-electromotive force (back-EMF) zero-crossing point detecting circuitry is employed. The effect of a rotor saliency on the back-EMF's zero-crossing point detection is analyzed using the extended EMF-based voltage equation of the interior permanent BLDCM in a stationary reference frame, and thus the overall analysis is considerably simplified compared to the conventional one. Simulation results are provided to verify the effectiveness of the proposed method.