• Title/Summary/Keyword: Z-value

Search Result 1,114, Processing Time 0.031 seconds

Vertical Ozone Distribution over Seoul: Ozonesonde Measurements During June 6~9, 2003 (서울지역 연직 오존 분포: 2003년 6월 6~9일 오존존데 관측)

  • Hwang, Mi-Kyoung;Kim, Yoo-Keun;Oh, In-Bo;Song, Sang-Keun;Lim, Yun-Kyu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.2
    • /
    • pp.196-205
    • /
    • 2008
  • Variability in vertical ozone and meteorological profiles was measured by 2Z electrochemical concentration cells (ECC) ozonesonde at Bangyi in Seoul ($37.52^{\circ}N$, $127.13^{\circ}E$) during June $6{\sim}9$, 2003 in odor to identify the vertical distribution of ozone and its relationship with the lower-atmospheric structure resulted in the high ozone concentrations near the surface. The eight profiles obtained in the early morning and the late afternoon during the study period clearly showed that the substantial change of ozone concentrations in lower atmosphere(${\sim}5\;km$), indicating that it is tightly coupled to the variation of the planetary boundary layer (PBL) structure as well as the background synoptic flow. All profiles observed early in the morning showed very low ozone concentrations near the surface with strong vertical gradients in the nocturnal stable boundary layer due to the photochemical ozone loss caused by surface NO titration under very weak vertical mixing. On the other hand, relatively uniform ozone profiles in the developed mixing layer and the ozone peaks in the upper PBL, were observed in the late afternoon. It was noted that a significant increase in ozone concentrations in the lower atmosphere occurred with the corresponding decrease of the mixing height in the late afternoon on June 8. Ozone in upper layer did not vertically vary much compared to that in PBL but changed significantly on June 6 that was closely associated with the variation of synoptic flows. Interestingly, heavily polluted ozone layers aloft (a maximum value of 115 ppb around 2 km) were formed early in the morning on 6 through 7 June under dominant westerly synoptic flows. This indicates the effects of the transport of pollutants on regional scale and consequently can give a rise to increase the surface ozone concentration by downward mixing processes enhanced in the afternoon.

Early Changes after Death of Plaice, Paralichthys olivaceus Muscle -6. Effect of Killing Methods on Morphological Changes of Myofibrills and Histological Changes of Muscle- (넙치 (Paralichthys olivaceus)육의 사후조기변화 -6. 치사 방법이 근원섬유의 형태학적 및 육의 조직학적인 변화에 미치는 영향-)

  • CHO Young-Je;LEE Nam-Geoul;KIM Yuck-Yong;KIM Jae-Hyun;LEE Keun-Woo;KIM Geon-Bae;CHOI Young-Joon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.27 no.4
    • /
    • pp.327-334
    • /
    • 1994
  • This study was undertaken to clarify the effect of killing methods on the morphological and histological changes of plaice, Paralichthys olivaceus muscle at early stage after killing. Killed samples by the three different methods were stored at $5^{\circ}$, and the changes in breaking strength of muscle, morphological observation of myofibrils and histological observation of extracellular spaces through storage were monitored. Samples killed by electrifying in sea water showed the maximum value of breakin strength immediately after killing and then it dropped significantly(p<0.05) until 2.5hrs passed. Breaking strength of samples killed by spiking at the head instantly and dipping in sea water including anesthetic rose steadily over 10hrs and 15hrs after killing, respectively. In myofibrills prepared from dorsal muscles immediately after spiking at the head instantly, A-band, H-band, I-band, and Z-line in sarcomere were clearly distinguishable each other. Due to muscle contraction by electrical stimulation, it was impossible to distinguish H-band from I-band observed in sarcomere immediately after killing for samples killed by electrifying. But, in the cases of samples killed by spiking and dipping, H-band could be observed dimly until 10hrs and 15hrs storage. No extracellular space was observed among muscle cells immediately after spiking at the head instantly. Samples killed by spiking at the head instantly and dipping in sea water including anesthetic showed extracellular spaces among all muscle cells after 15hrs and 25hrs storage, respectively. The other hand, samples killed by electrifying in sea water (110V, 30sec.) showed a few extracellular spaces immediately after killing and then it showed extracellular spaces among all muscle cells after 2.5hrs storage.

  • PDF

Usefulness of Flow Composite Image in Raynaud Scan ($^{201}Tl$) ($^{201}Tl$을 이용한 레이노 검사에서 동적 Composite 영상의 유용성)

  • Kim, Dae-Yeon;Shin, Gyoo-Seol;Oh, Eun-Jung;Kim, Gun-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.101-104
    • /
    • 2010
  • Purpose: Raynaud scan is divided to flow, blood pool and local-delay image. Usually, we evaluate comparison through blood pool and local-delay image. We will evaluate about usability when comparative observe blood image and local-delay image in Raynaud scan that used $^{201}Tl$ as making flow image to one sheet of images. Materials and Methods: We have selected 29 Raynaud phenomenon patients aged 14~68 years who visited department of vascular surgery between Feb. 2008 and Aug. 2009. An intravenous injection $^{201}Tl$ of 111 MBq (3 mCi) to opposite side diagonal line limbs above an internal auditing department. Equipment used Philips gamma camera forte A-Z, and collimator used LEHR. Matrix size set up to each $64{\times}64$, $128{\times}128$, $256{\times}256$ and zoom factor used to full field. Protocol of dynamic is 2 second to 155 frames. Blood pool and delay count to 300 second. We set up ROI by a foundation to data acquired in PEGASYS processing program. Each results were analyzed with the SPSS 12.0 statistical software. Results: Each averages of count ratio (Rt / Lt) to have been given at composite image, a blood pool image, delay images analyzed at Raynaud phenomenon patients is $1.25{\pm}0.39$, $1.20{\pm}0.33$, $1.11{\pm}0.17$. The sample analysis results of blood pool image and delay image contented itself with p<0.029. Also, there don't have been each difference, and blood pool image, delay image regarding composite image was able to know. Conclusion: We were able to give help for comparison to evaluate a blood pool image and a local delay image at the Raynaud scan which used $^{201}Tl$ while making a flow image to one sheet image. Identification to be visual too was possible. If you are proceeded a researcher that there was further depth, you are more appropriate for, and you may get useful information.

  • PDF

Quality Assurance Program of Electron Beams Using Thermoluminescence Dosimetry (열형광선량계를 이용한 전자선 품질보증 프로그램에 관한 연구)

  • Rah Jeong-Eun;Kim Gwe-Ya;Jeong Hee-Kyo;Shin Dong-Oh;Suh Tae-Suk
    • Progress in Medical Physics
    • /
    • v.16 no.2
    • /
    • pp.62-69
    • /
    • 2005
  • The purpose of this study has been performed to investigate the possibility of external audit program using thermoluminescence dosimetry for electron beam in korea. The TLD system consists of LiF powder, type TLD-700 read with a PCL 3 reader. In order to determine a calibration coefficient of the TLD system, the reference dosimeters are irradiated to 2 Gy in a $^{60}CO$ beam at the KFDA The irradiation is performed under reference conditions is water phantom using the IAEA standard holder for TLD of electron beam. The energy correction factor is determined for LiF powder irradiated of dose to water 2 Gy in electron beams of 6, 9, 12, 16 and 20 MeV (Varian CL 2100C). The dose is determined according to the IAEA TRS-398 and by measurement with a PTW Roos type plane-parallel chamber. The TLD for each electron energy are positioned in water at reference depth. In this study, to verify of the accuracy of dose determination by the TLD system are performed through a 'blind' TLD irradiation. The results of blind test are $2.98\%,\;3.39\%\;and\;0.01\%(1\sigma)$ at 9, 16, 20 MeV, respectively. The value generally agrees within the acceptance level of $5\%$ for electron beam. The results of this study prove the possibility of the TLD quality assurance program for electron beams. It has contributed to the improvement of clinical electron dosimetry in radiotherapy centers.

  • PDF

Accumulation of Heavy Metals(Cd, Cu, Zn, and Pb) in Five Tree Species in Relation to Contamination of Soil near Two Closed Zinc-Mining Sites (아연폐광산(亞鉛廢鑛山) 주변(周邊) 토양(土壤)의 중금속(重金屬) (Cd, Cu, Zn, Pb) 오염(汚染)에 따른 5개(個) 수종(樹種)의 부위별(部位別) 중금속(重金屬) 축적(蓄積))

  • Han, Sim Hee;Hyun, Jung Oh;Lee, Kyung Joon;Cho, Duck Hyun
    • Journal of Korean Society of Forest Science
    • /
    • v.87 no.3
    • /
    • pp.466-474
    • /
    • 1998
  • This study was conducted to evaluate heavy metal concentrations(Cd, Cu, Z, and Pb) in the soil of two zinc mines and to correlate heavy metal contents between the soils and trees growing near the mines. Soils and leaves, stems, and roots of five tree species(Corylus heterophylla, Pinus rigida. Populus alba${\times}$glandulosa, Rhododendron mucronulatum, and Robinia pseudoacacia) were collected from Sambo Zinc Mine located in Hwasung and Gahak Zinc Mine in Kwangmyung city in Kyonggido. Soils near two zinc mines were not seriously contaminated by heavy metals, but Zn and Pb concentrations were at toxic level. The heavy metal concentration in soils decreased in the order of Zn, Pb, Cu, and Cd, and decreased with increasing distance from zinc mining sites. Among the five tree species, Populus alba ${\times}$ glandulosa showed the highest heavy metal concentrations in the tissue except for Pb. Particulars, leaves of the species contained the high concentrations of heavy metals to reach the maximum of 91ppm Zn. The roots of Corylus heterophylla contained high concentrations of Cu and Pb. The order of heavy metal concentrations in the tree species was Zn, Cu, Pb and Cd. The concentration of heavy metals in the tree tissues showed a positive correlation with that in soil in which trees are growing. The ratio of heavy metal concentration of trees to that of soils(concentration factor : CF) was highest in Zn and lowest in Pb. Populus alba${\times}$glandulosa had the highest CF value among the five tree species. It was concluded that Populus alba${\times}$glandulosa, based on the high metal uptake ability, could be used for decontaminating of heavy metals from contaminated soils, and Pinus rigida could be used to reflect the level of contamination in soils.

  • PDF

A Study on the Forest Vegetation and Soil-environmental Factors Affecting the Water Quality of Iwonch on Stream (이원천 수질에 미치는 삼림식생과 토양환경요인)

  • Bang, Je-Yong;Yang, Keum-Chul
    • Korean Journal of Environmental Biology
    • /
    • v.27 no.2
    • /
    • pp.183-190
    • /
    • 2009
  • Characterization of the analysis of forest vegetation, soil environmental conditions and water quality were performed from March 2003 to March 2007. The two basins were characterized by cultivated area (Kaesim reservoir) and mountain area (Jangchan reservoir), and divided into eleven small basins, where dynamics of pollutants, forest vegetation and soil environmental conditions were surveyed. The vegetation can be divided into 10 types by $Z\ddot{u}rich$-Montpellier school's method. Pearson coefficients between vegetation type and water quality were correlated with dissolved oxygen (DO) in the Quercus variabilis community at the 5% level and total phosphorus (TP) in the Larix leptolepis plantation at the 1% level. Especially total phosphorous and total nitrogen increased in small basins where the proportion of cultivated and residential area increased. The analysis of influences of pollutant discharge on water quality showed that pollutant charge was very low in forest land area ($Y_{T-P}$=-0.0017X+0.2215, r=0.16, $Y_{COD}$=- 0.0395X+8.5051 r=0.47). The soil types of western area were comparatively simple, but those of eastern area were complicated with regosols, red-yellow soils, lithosoles, etc. The pH, total solid (TS) and volatile substance (VS) of the forest and agricultural land soils collected in each site were 5.4~6.9, 75.8~80.2%, and 3.80%~5.80%, respectively. According to the analytical result of soil environmental conditions, heavy metal contents fell short to the mean value of natural conditions. Runoff amount (Y) and depth of topsoil (X) were negatively correlated, $Y_{ron}=-1.0088X_{top}+35.378$ (r=0.68). The correlation was much lower in up-stream but much higher in down-stream, because permeation into soil particle was larger on down-stream due to its more or less gentle slope. Pearson coefficients between soil pH and water pH were statistically significant at 1% level.

Community Structure of Forest Vegetation in Mt. Geumsusan belong to Woraksan National Park (월악산국립공원 금수산 산림식생의 군집구조)

  • Kim, Ho-Jin;Shin, Jae-Kwon;Lee, Cheol-Ho;Yun, Chung-Weon
    • Korean Journal of Environment and Ecology
    • /
    • v.31 no.2
    • /
    • pp.202-219
    • /
    • 2017
  • The purpose of this study was to analyze the community structure of forest vegetation in Mt. Geumsusan belong to Woraksan National Park for providing basic information of ecological management. Data were collected by 41 plots from June to November in 2016 using Z-M phytosociology method, which was analyzed with vegetation types, mean importance value and coincidence method. As the results, the forest vegetation was classified into Quercus mongolica community group including Cornus controversa community, Castanea crenata community(Vegetation unit 3), Quercus variabilis community(Vegetation unit 4) and Q. mongolica community(Vegetation unit 5). C. controversa community was divided into two groups such as Ulmus davidiana var. japonica group(Vegetation unit 1) and Parthenocissus tricuspidata group(Vegetation unit 2). Mean importance percentage of vegetation unit 1 was showing Fraxinus rhynchophylla 14.9%, Morus bombycis 8.7% and Acer pictum subsp. mono 8.3%, that of unit 2 was Larix kaempferi 23.2%, C. controversa 20.1% and P. tricuspidata 6.5%, that of unit 3 was Q. mongolica 15.8%, C. crenata 13.4% and F. rhynchophylla 9.8%, that of unit 4 was Q. mongolica 26.6%, Q. variabilis 20.8% and Pinus densiflora 16.7%, that of unit 5 was Q. mongolica 48.3%, Styrax obassia 7.5%, F. rhynchophylla 5.3% in the order, respectively. Each vegetation unit was classified with dependance on environmental factors as 700m of altitude, $20^{\circ}$ of slope degree, middle slope of topography, 20% of bare rock, 30 taxa of present species, 80% of tree layer coverage rate and 20m of tree layer height. In conclusion, it was preferentially considered that development of peculiar and specific management methods with vegetation unit classified above should be needed for ecological and sustainable forest vegetation management.

A Study on Rail Vibration and Its Reduction Plan in Central Daejeon Area (대전 도심지역의 철도진동의 영향과 대책)

  • Ryu, Myoung-Ik;Suh, Man-Cheol;Lee, Won-Kook
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.4
    • /
    • pp.269-280
    • /
    • 2000
  • Rail vibration in city zone is becoming a serious environmental problem. In order to make a reduction plan for rail vibration, the research was conducted in which many experiments to measure actual rail vibration along the railroad through the central Deajeon area. A digital vibration level meter was used to measure rail vibration. Vibration levels of Z-axis were measured at every second for the duration of the train passing. The measuring station was placed at every 5m for the distance of 55m. A total of 353 different sets of vibration level were obtained. The signals were processed to get $L_{10}$ value and analyzed in terms of distance, train velocity, and number of trains. As a result, it has been found that rail vibration exceed the allowable vibraton limit of 60 dB, at the point of 25 m far from the railroad center, which is regulated by the las of vibration and noise. Train velocity was found to affect a little for vibration level within the zone. It was also found that a trench installed along a railroad could reduce vibration level up to approximately 10 percent. A model test was conducted to investigate the influence of the location and size of trench, on the transfer of vibration. A heavy steel ball was used to generate vibrations. On the basis obtained from this study, it could be concluded that the application of distance-attenuation and the installment of a trench along railroad could be applied as a reduction plan for rail vibration. Because limitions might exist to depend on the effect of distance attenuation, trenchs excavated along a railroad might be suggested as the most efficient solution to reduce railroad vibration.

  • PDF

The Impact on Fish Assemblage by the River Connectivity Fragmentation: Case Study of the Danjang Stream, South Korea (하천 연속성 단절이 어류상에 미치는 영향: 밀양 단장천을 중심으로)

  • Seung-Been Heo;Kang-Hui Kim;Donghyun Hong;Hyeon-Sik Lee;Gu-Yeon Kim;Gea-Jae Joo;Hyunbin Jo
    • Korean Journal of Ecology and Environment
    • /
    • v.55 no.3
    • /
    • pp.231-243
    • /
    • 2022
  • Anthropogenic disturbances on freshwater ecosystem are known to degrade biodiversity, especially on fish assemblage. In this study, we have conducted fish surveys to identify impact of a bridge construction on fish assemblages. A total of eight study sites were surveyed in the Danjang and the Dong Stream in southern part of South Korea from June to November in 2021. The fish samplings were carried out five times, using cast-nets(10×10 mm mesh size), scoop-nets(4×4 mm, 5×5 mm mesh size), set-nets (10×10 mm mesh size), and fish traps (3×3 mm mesh size), along with the Stream/River Ecosystem Survey and Health Assessment by the Ministry of Environment of Korea and basic water quality measurement. Also, we applied the species diversity index and length-weight relationship regressions on certain species to identify interspecific growth rate differences in accordance with study sites. As a result, a total of 782 individuals, 23 species and 10 families were collected. The dominant species was Zacco Koreanus and relative abundance was 50.89%. When applying the length-weight relationship regressions on certain species, the 'b' value for Z. Koreanus was lower at the downstream points than at the upstream points of the construction site. In addition, when comparing to the results of the past survey, relative density of demersal fish at the upstream and downstream points decreased from 26% to 1.4%, and from 18% to 6.3%, respectively. In conclusion, it is considered that bridge construction negatively affects the habitat of fishes, especially on demersal fishes. Therefore, appropriate conservation efforts such as installation of silt protector and sand sedimentation pond are needed to alleviate the disturbance in habitat such as occurrence of turbidity and destruction of micro-habitats.

Evaluation of the effect of a Position Error of a Customized Si-Bolus Produced using a 3D-Printer: Cervical Cancer Radiation Treatment (3D 프린터를 이용하여 제작한 맞춤형 Si-Bolus의 위치 오차 효과 평가: 자궁경부암 방사선 치료)

  • Seong Pyo Hong;Ji Oh Jeong;Seung Jae Lee;Byung Jin Choi;Chung Mo Kim;Soo Il Jung;Yun Sung Shin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.7-13
    • /
    • 2023
  • Purpose: In this study, we evaluated the effect of using a customized bolus on dose delivery in the treatment plan when cervical cancer protruded out of the body along with the uterus and evaluated reproducibility in patient set-up. Materials & Methods: The treatment plan used the Eclipse Treatment Planning System (Version 15.5.0, Varian, USA) and the treatment machine was VitalBeam (Varian Medical Systems, USA). The radiotherapy technique used 6 MV energy in the AP/PA direction with 3D-CRT. The prescribed dose is 1.8 Gy/fx and the total dose is 50.4 Gy/28 fx. Semiflex TM31010 (PTW, Germany) was used as the ion chamber, and the dose distribution was analyzed and evaluated by comparing the planned and measured dose according to each position movement and the tumor center dose. The first measurement was performed at the center by applying a customized bolus to the phantom, and the measurement was performed while moving in the range of -2 cm to +2 cm in the X, Y, and Z directions from the center assuming a positional error. It was measured at intervals of 0.5 cm, the Y-axis direction was measured up to ±3 cm, and the situation in which Bolus was set-up incorrectly was also measured. The measured doses were compared based on doses corrected to CT Hounsfield Unit (HU) 240 of silicon instead of the phantom's air cavity. Result: The treatment dose distribution was uniform when the customized bolus was used, and there was no significant difference between the prescribed dose and the actual measured value even when positional errors occurred. It was confirmed that the existing sheet-type bolus is difficult to compensate for irregularly shaped tumors protruding outside the body, but customized Bolus is found to be useful in delivering treatment doses uniformly.

  • PDF