• Title/Summary/Keyword: Z buffer

Search Result 98, Processing Time 0.023 seconds

On the computation of low-subsonic turbulent pipe flow noise with a hybrid LES/LPCE method

  • Hwang, Seungtae;Moon, Young J.
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.1
    • /
    • pp.48-55
    • /
    • 2017
  • Aeroacoustic computation of a fully-developed turbulent pipe flow at $Re_{\tau}=175$ and M = 0.1 is conducted by LES/LPCE hybrid method. The generation and propagation of acoustic waves are computed by solving the linearized perturbed compressible equations (LPCE), with acoustic source DP(x,t)/Dt attained by the incompressible large eddy simulation (LES). The computed acoustic power spectral density is closely compared with the wall shear-stress dipole source of a turbulent channel flow at $Re_{\tau}=175$. A constant decaying rate of the acoustic power spectrum, $f^{-8/5}$ is found to be related to the turbulent bursts of the correlated longitudinal structures such as hairpin vortex and their merged structures (or hairpin packets). The power spectra of the streamwise velocity fluctuations across the turbulent boundary layer indicate that the most intensive noise at ${\omega}^+$ < 0.1 is produced in the buffer layer with fluctuations of the longitudinal structures ($k_zR$ < 1.5).

Registration of Dental Range Images from a Intraoral Scanner (Intraoral Scanner로 촬영된 치아 이미지의 정렬)

  • Ko, Min Soo;Park, Sang Chul
    • Korean Journal of Computational Design and Engineering
    • /
    • v.21 no.3
    • /
    • pp.296-305
    • /
    • 2016
  • This paper proposes a framework to automatically align Dental range image captured by depth sensors like the Microsoft Kinect. Aligning dental images by intraoral scanning technology is a difficult problem for applications requiring accurate model of dental-scan datasets with efficiency in computation time. The most important thing in dental scanning system is accuracy of the dental prosthesis. Previous approaches in intraoral scanning uses a Z-buffer ICP algorithm for fast registration, but it is relatively not accurate and it may cause cumulative errors. This paper proposes additional Alignment using the rough result comes after intraoral scanning alignment. It requires that Each Depth Image of the total set shares some overlap with at least one other Depth image. This research implements the automatically additional alignment system that aligns all depth images into Completed model by computing a network of pairwise registrations. The order of the each individual transformation is derived from a global network and AABB box overlap detection methods.

ANTICARIOGENCI EFFECT OF COMPOMER AND RMGIC (수복용 compomer 의 항우식성에 관한 연구)

  • Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.1
    • /
    • pp.12-15
    • /
    • 2002
  • The first purpose of present study was to compare the anticariogenic effect of compomer, resin modified glass ionomer cement and composite (RMGIC). The second purpose was to evaluate the recently introduced methods, which use confocal scanning micro-scope, in detecting initial caries around restoration. 2$\times$4$\times$1.5mm cavities were prepared from the recently extracted 50 human teeth on the buccal or lingual surface. The prepared teeth were randomly devided into 5 groups and restored with each filling material. Group 1: Dyract AP, Group 2: compoglass F, Group 3: F2000, Group 4: Z100. Group 5:Fuji II LC. The teeth were stored for 30 days in the distilled water, then stored in the buffer solution for artificial caries development: pH 4.3, lactic acid 100 mM, calcium 16 mM, phosphate 8mM, sodium azide 3mM. Then, the samples were sectioned longitudinally and examined with confical scanning microscope. The results showed that the use of compomer and resin modified glass ionomer cement showed caries inhibition zone whereas the composite did not. There was no difference in the width of caries inhibition zone between compomers and RMGIC. The confocal scanning microscope was useful in detecting initial caries around restoration.

A Study on True Ortho-photo Generation Using Epipolar Geometry and Classification Algorithm (에피폴라 기하와 군집화 알고리즘을 이용한 정밀 정사투영영상 제작에 관한 연구)

  • Oh, Kum-Hui;Hwang, Hyun-Deok;Kim, Jun-Chul;Shin, Sung-Woong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.26 no.6
    • /
    • pp.633-641
    • /
    • 2008
  • This study introduces the method of detecting and restoring occlusion areas by using epipolar algorithm and K-means classification algorithm for true ortho-photo generation. In the past, the techniques of detecting occlusion areas are using the reference images or information of buildings. But, in this study the occlusion areas can be automatically detected by using DTM data and exterior orientation parameters. The detected occlusion areas can be restored by using anther images or the computed values which are determined in K-means classification algorithm. In addition, this method takes advantages of applying epipolar algorithm in order to find same location in overlapping areas among images.

Analysis of Stop-and-Wait ARQ Protocol under Markovian interruption (Markovian 간섭 신호하에서의 Stop-­and-­Wait ARQ Protocol의 성능 분석)

  • 김성일;신병철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.8
    • /
    • pp.1674-1683
    • /
    • 2003
  • The performance of a packet data multiplexer with stop­and­wait ARQ protocols under Markovian interruption is considered in this work It is assumed that the input process, into the system is Poisson process, and that the output channel is divided into a series of time slots and a data packet can be transmitted in a slot time. In this system the round­trip propagation delay is defined to be the frame time. It is modeled that the output channel can be blocked by some Markevian interruption, whose state change between the blocking and non­-blocking states is given by Markov process. The overall system has been analyzed by constructing a relationship, taking the Markovian interruption into account, about the buffer behavior between the successive frames of slots. The validity of this analytical results has been verified by computer simulation.

A Study on the electric field distribution of design of LiNbO$_3$ optical waveguide (LiNbO$_3$ 광 도파로의 전계분포 및 설계에 관한 연구)

  • 강기성;소대화
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.288-293
    • /
    • 2000
  • BPM simulation was used in order to fabricate the LiNbO$_3$optical waveguide with optical source of He-Ne laser(λ=0.6328[$\mu$m]). we observed electric field E$_{x}$, E$_{y}$ in the x,y-direction are simulated at the LiNbO$_3$substrate (X1 55[$\mu$m]$\times$Z1 5000[$\mu$m]), where the depth, width and buffer layer of waveguide are 0.2[$\mu$m],4[$\mu$m] and 0.02[$\mu$m] respectively. By applying these parameters of single waveguide to simulate a X-switch, we have chosen index change of 0.002, width of 3[$\mu$m] and angle of 0.4$^{\circ}$~0.6$^{\circ}$of optical waveguide and under these conditions, optical beam propagates cross-side at 0.4$^{\circ}$. When applied switching voltage of 25[V], optical beam of X-switch turns cross-side to bar-side at intersection angle 0.4$^{\circ}$, index change of 0.002, waveguide width of 3[$\mu$m], electrode gap 2[$\mu$m]. By the above results, we can obtain design conditions of theoretical analysis of an X-switch optical waveguide.e.e.

  • PDF

THE ANTICARIOGENIC EFFECT OF F IN PRIMER, BONDING AGENT AND COMPOSITE RESIN IN THE CAVOSURFACE ENAMEDL AREA (Primer Bonding agent, 복합레진 내의 볼소의 법랑질에 대한 항우식 작용)

  • Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.2
    • /
    • pp.635-641
    • /
    • 1996
  • This study was designed to evaluate the anti cariogenic effect of F in primers, bonding agents, composite resins or glass ionomer cements in enamel. Twenty-five extracted teeth were selected and a cavity was prepared on either the buccal or the lingual surface of each tooth. After pumicing and etching, the samples were divided into 5 groups. In group A, the samples were primed, bonded and filled with ART bond and Brilliant Enamel (Coltene, Switzerland). Group B composed of Optibond and Herculited XRV (Kerr, USA), group C composed of Syntac and Tetric(Vivadent, Lichtenstein), and group D composed of Scotch-bond Multipurpose and Z 100 (3M, YSA). In group E, the samples were filled with glass ionomer cement (Fuji II LC, Japan), All surfaces except the 2mm beyond the cavosurface margin of the sample were protected, and samples were then put into an acid buffer for 3 days to develop the initial caries. The samples were then sectioned through the filling body into thin wafers and then examined with a polarizing microscope under water imbibition. The fluoride in primer, bonding agent, or composite filling material did not prevent the initial caries in the enamel area adjacent to the filling body whereas the fluoride in the glass ionomer did prevent the initial stage caries.

  • PDF

Detecting and Restoring the Occlusion Area for Generating the True Orthoimage Using IKONOS Image (IKONOS 정사영상제작을 위한 폐색 영역의 탐지와 복원)

  • Seo Min-Ho;Lee Byoung-Kil;Kim Yong-Il;Han Dong-Yeob
    • Korean Journal of Remote Sensing
    • /
    • v.22 no.2
    • /
    • pp.131-139
    • /
    • 2006
  • IKONOS images have the perspective geometry in CCD sensor line like aerial images with central perspective geometry. So the occlusion by buildings, terrain or other objects exist in the image. It is difficult to detect the occlusion with RPCs(rational polynomial coefficients) for ortho-rectification of image. Therefore, in this study, we detected the occlusion areas in IKONOS images using the nominal collection elevation/azimuth angle and restored the hidden areas using another stereo images, from which the rue ortho image could be produced. The algorithm's validity was evaluated using the geometric accuracy of the generated ortho image.

A Study on the Design and Implementation of Contact Resistance Measurement System and Andoroid OS App. (접촉저항 측정 시스템 및 안드로이드 운영체제 앱 설계 및 구현에 관한 연구)

  • Boo, Ra-Yun;Choi, Jung-Hun;An, Byung-Ho;Lee, Myung-Eui
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2022.11a
    • /
    • pp.188-190
    • /
    • 2022
  • 본 연구에서는 정전류(Constant Current) 방식에 전압강하법을 이용하여 접촉저항 측정 시스템을 구현하고 측정값을 블루투스 통신을 통해 안드로이드 운영체제에서 확인할 수 있도록 앱을 개발한다. 측정가능한 범위로 0 Ω에서 10.24 Ω 사이의 접촉 저항을 MCP3424 18 bit 분해능 ADC를 사용하여 측정할 수 있도록 설계하였다. 기존에는 반고정 저항과 별도의 전류계를 이용하여 정전류를 설정하였으나, 본 연구에서는 측정의 정밀도 및 편리성 개선을 위해 0.1% 고정밀 고정저항을 병렬로 4개 연결하여 구현하였으며, 또한 1:1 Unity Gain Buffer를 구성하고 Ultra High Precision Z-Foil 방식으로 오차 0.01%, 온도 계수 0.05 ppm/℃ 저항을 사용하여 실제로 측정한 샘플 저항 값의 결과를 확인하였다.

Validation of LC-MS/MS Method for Determination of Rabeprazole in Human Plasma : Application of Pharmacokinetics Study (인체 혈장중 라베프라졸의 정량을 위한 LC-MS/MS 분석법 검증 및 단일 용량 투여에 의한 약물동태 연구)

  • Tak, Sung-Kwon;Seo, Ji-Hyung;Ryu, Ju-Hee;Choi, Sang-Joon;Lee, Myung-Jae;Kang, Jong-Min;Lee, Jin-Sung;Hong, Seung-Jae;Yim, Sung-Vin;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.1
    • /
    • pp.73-78
    • /
    • 2009
  • A simple LC-MS/MS method of rabeprazole in human plasma was developed and validated. Rabeprazole and Internal standard (I.S), omeprazole, were extracted from human plasma by liquid liquid extraction, chromatographic separation of rabaprazole in plasma was achieved at $45^{\circ}C$ with a Shiseido UG120 $C_{18}$ column and methanol-10 mM ammonium acetate buffer (pH 9.42 with ammonium water), as mobile phase. Rabeprazole produced a protonated precursor ion [$(M+H)^+$] at m/z 360.10 and corresponding product ion at m/z 242.21. Internal standard produced a protonated precursor ion [$(M+H)^+$] at 346.09 and corresponding product ion at m/z 198.09. This method showed linear response over the concentration range of $1{\sim}500\;ng/mL$ with correalation coefficient greater than 0.99. The lower limit of quantitation (LLOQ) using 0.2 mL plasma was 1 ng/mL, which was sensitive enough for pharmacokinetics studies. The method was specific and validated with a limit of quantitation of 1 ng/mL. The intra-day and inter-day precision and accuracy were acceptable for all samples including the LLOQ. The applicability of the method was demonstrated by analysis of plasma after administration of a single 10 mg dose to 36 healthy subject. From the plasma rabeprazole concentration versus time curves, the mean $AUC_t$ (The area under the plasma concentration-time curve from time 0 to 12 hr ) was $691.36{\pm}321.88\;ng{\cdot}hr/mL$, $C_{max}$ (maximum plasma drug concentration) of $353.21{\pm}131.52\;ng/mL$ reached $3.4{\pm}1.1\;hr$ after adiministration. The mean biological half-life of rabeprazole was $1.37{\pm}0.75\;hr$. Based on the results, this simple method could readily be used in pharmacokinetics studies.