• Title/Summary/Keyword: Y-ray

Search Result 17,660, Processing Time 0.054 seconds

A New X-Ray Image Sensor Utilizing a Liquid Crystal Panel (새 구조의 액정 엑스선 감지기)

  • Rho, Bong-Gyu
    • Korean Journal of Optics and Photonics
    • /
    • v.19 no.4
    • /
    • pp.249-254
    • /
    • 2008
  • We developed a new x-ray image sensor utilizing a reflection-mode liquid crystal panel as its sensitive element, and tested its functionality by using it to obtain an x-ray image of a printed circuit board. In the liquid crystal x-ray image sensors hitherto reported, the liquid crystal layer is in direct contact with the photoconductive film which is deposited on a glass substrate. In the fabrication of the new x-ray image sensor, a liquid crystal panel is fabricated in the first step by using a pair of glass plates of a few centimeters thicknrss. Then one of the glass substrates is ground until its thickness is reduced to about $60\;{\mu}m$. After polishing the glass plate, dielectric films for high reflectance at 630 nm, a film of amorphous selenium for photoconduction, and a transparent conductive film for electrode are deposited in sequence. The new x-ray image sensor has several merits: primarily, fabrication of a large area sensor is more easily compared with the old fashioned x-ray image sensors. Since the reflection type liquid crystal panel has a very steep response curve, the new x-ray sensor has much more sensitivity to x-rays compared with the conventional x-ray area sensor, and the radiation dosage can be reduced down to less then 20%. By combining the new x-ray sensor with CCD camera technology, real-time x-ray images can be easily captured. We report the structure, fabrication process and characteristics of the new x-ray image sensor.

The Compensation of Image Distortion on the X - Ray Image Intensifier (X - Ray 검사 시스템에서 Image Intensifier의 왜곡 보정)

  • Shin, Dong-Chul;Oh, Choon-Suk
    • The Transactions of the Korea Information Processing Society
    • /
    • v.5 no.4
    • /
    • pp.1044-1047
    • /
    • 1998
  • Non-destructive x-ray inspection system needs image intensifier to obtain the x-ray image. Captured image from image intensifier is distorted because the input plate of image intensifier has a spherical surface. In the research, in order to compensate this image distortion, we created the model of image intensifier and show mathematically that the image distortion was compensated. To show the performance of the proposed method, experiment was performed in real x-ray inspection system.

  • PDF

X-ray PIV Measurements of Velocity Field of Blood Flows

  • Lee, Sang-Joon;Kim, Guk-Bae
    • 순환기질환의공학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.28-36
    • /
    • 2006
  • The x-ray PIV method was improved for measuring quantitative velocity fields of real blood flows using a coherent synchrotron x-ray source. Without using any contrast media or seeding particles, this method can visualize flow pattern of blood by enhancing the phase-contrast and interference characteristics of blood cells based on a synchrotron x-ray imaging mechanism. The enhanced x-ray images were achieved by optimizing the sample-to-scintillator distance, the sample thickness, and hematocrit. The quantitative velocity fields of blood flows inside opaque tubes were obtained by applying a 2-frame PIV algorithm to the x-ray images of the blood flows. The measured velocity field data show typical features of blood flows such as the yield stress effect. The non-Newtonian flow characteristics of blood flows were analyzed using the x-ray PIV method and the experimental results were compared with hemodynamic models.

  • PDF

Lateral Conduction of Preservative Solution in Larix kaempferi Woods

  • Ahmed, Sheikh Ali;Park, Jeong-Hwan;Chun, Su-Kyoung
    • Journal of the Korea Furniture Society
    • /
    • v.19 no.2
    • /
    • pp.151-155
    • /
    • 2008
  • An experiment was conducted to observe the 5% CCFZ solution penetration depth through ray parenchyma and ray tracheid of Larix kapempferi. Moisture content was adjusted 28% for both sapwood and heartwood. Even though the moisture content was same, heartwood was 1.3 times less permeable than sapwood and the difference was found statistically significant. Due to anatomical differences between ray parenchyma and ray tracheid, ray parenchyma was about 1.3 times more permeable than ray tracheid. Penetration speed was high initially and it decreased rapidly in course of time.

  • PDF

Propagation Analysis Method in using 3D Ray Tracing Model in Wireless Cell Planning Software (무선망 설계툴에서 3 차원 광선 추적법을 이용한 전파해석 방법)

  • Shin, Young-Il;Jung, Hyun-Meen;Lee, Seong-Choon
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.251-255
    • /
    • 2007
  • In this paper, propagation analysis method in using 3D Ray Tracing propagation model in wireless cell planning is proposed. Through 3D Ray Tracing model, we can predict the distribution of propagation loss of the received signal. For correct and a low complex analysis, Quad Tree and Pre-Ordering and Hash Function algorithms are included in 3D Ray Tracing algorithm. And 3D Ray Tracing model is embodied in CellTREK that is developed by KT and used to plan Wibro system analysis. In CellTREK, propagation analysis is performed and that result is represented in 3D viewer. In numerical results, it is showed that the proposed scheme outperforms Modified HATA model when comparing with measurement data.

  • PDF

Development of PC based High Voltage Generator for Dental CT (PC기반 치과 CT용 고전압 펄스 발생장치 개발)

  • Kim, Hack-Seong;Oh, Jun-Yong;Song, Sang-Hoon;Won, Choong-Yeon
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.580-582
    • /
    • 2008
  • The object of this paper is develope the PC based controlled high voltage power supply and studies 1.2kW(120kV, 10mA) pulse power X-ray generator possible to adapt fluoroscopy of Dental CT X-ray generator and industrial X-ray pulse power equipment. The developed pulse power X-ray generator consisted of mono-block tank include X-ray tube and high voltage X-ray power supply circuit and high voltage control unit with RS232C/422 communication port. The PC control program of pulse power X-ray generator uses LabVIEW, and the size of high voltage transformer and high voltage generator is minimized by high voltage high frequency inverter has 100kHz switching frequency. Also this paper shows result of X-ray tube voltage and tube current correspond to variable load.

  • PDF

X-ray PIV Measurements of Velocity Field of Blood Flows

  • Lee, Sang-Joon;Kim, Guk-Bae
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 2006
  • The x-ray PIV method was improved for measuring quantitative velocity fields of real blood flows using a coherent synchrotron x-ray source. Without using any contrast media or seeding particles, this method can visualize flow pattern of blood by enhancing the phase-contrast and interference characteristics of blood cells based on a synchrotron x-ray imaging mechanism. The enhanced x-ray images were achieved by optimizing the sample-to-scintillator distance, the sample thickness, and hematocrit. The quantitative velocity fields of blood flows inside opaque tubes were obtained by applying a 2-frame PIV algorithm to the x-ray images of the blood flows. The measured velocity field data show typical features of blood flows such as the yield stress effect. The non-Newtonian flow characteristics of blood flows were analyzed using the x-ray PIV method and the experimental results were compared with hemodynamic models.

  • PDF

Understanding our Universe with the REFLEX II cluster survey

  • Chon, Gayoung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.41.1-41.1
    • /
    • 2014
  • Clusters of galaxies provide unique laboratories to study astrophysical processes on large scales, and are also important probes for cosmology. X-ray observations are still the best way to find and characterise clusters. The extended ROSAT-ESO flux-limited X-ray (REFLEX II) galaxy clusters form currently the largest well-defined and tested X-ray galaxy cluster sample, providing a census of the large-scale structure of the Universe out to redshifts of z-0.4. I will describe the properties of the survey and the X-ray luminosity function, which led to our recent cosmological constraints on omegaM-sigma8. They tighten the previous constraints from other X-ray experiments, showing good agreements with those from the Planck clusters, but some tension exists with the Planck CMB constraints. The second part of my talk will concern the structure of the local Universe, and the study of the first X-ray superclusters. The density of the clusters reveals an under-dense region in the nearby Universe, which has an interesting implication for the cosmological parameters. Using the X-ray superclusters, that are constructed with a physically motivated procedure, I will show environmental aspects that X-ray superclusters provide, and compare to cosmological N-body simulations.

  • PDF

Flow Measurement in Xylem Vessels of a Bamboo Leaf Using Synchrotron X-ray Micro Imaging (Synchrotron X-ray 미세영상기법을 이용한 식물 목질부 내부 수액 유동의 계측)

  • Kim Yang Min;Lee Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.83-86
    • /
    • 2003
  • Synchrotron X-ray micro imaging technique was employed to non-invasively monitor the water flow inside xylem vessels in a bamboo leaf. The phase contrast X-ray images clearly visualized plant anatomy and the rise of a water front inside the vessels. Consecutive X-ray images taken for 60 seconds revealed water rise kinetics against gravity in the xylem of a cut dry leaf taken from a bamboo tree. For the first time, traces of water rise, variation of contact angle between water and xylem wall as well as the internal structure of xylem were obtained. In xylem vessels, a repeating flow pattern has a typical flow velocity of $30.7{\mu}m/s$ and faster flow is established intermittently. It is concluded that the transmission type of X-ray micro imaging can be used as a powerful tool to investigate the ascent of sap in the xylem vessels at a resolution higher than that of MRI.

  • PDF

Study on Automatic Generation of Platform Configuration Register in FlexRay Protocol (FlexRay 프로토콜에서 플랫폼 구성 변수의 자동 생성에 관한 연구)

  • Yang, Jae-Sung;Park, Jee-Hun;Lee, Suk;Lee, Kyung-Chang;Choi, GwangHo
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.7 no.1
    • /
    • pp.41-52
    • /
    • 2012
  • Recently, FlexRay was developed to replace controller area network (CAN) protocol in chassis networking systems, to remedy the shortage of transmission capacity and unsatisfactory real-time transmission delay of conventional CAN. FlexRay network systems require correct synchronization and complex scheduling parameters. However, because platform configuration register (PCR) setting and message scheduling is complex and bothersome task, FlexRay is more difficult to implement in applications than CAN protocol. To assist a network designer for implementing FlexRay cluster, this paper presents an analysis of FlexRay platform configuration register and automatic generation program of PCR. To demonstrate the feasibility of the automatic generation program, we evaluated its performance using experimental testbed.