• Title/Summary/Keyword: Y-coupling

Search Result 6,745, Processing Time 0.057 seconds

Insulation Properties and Evaluation of Diglycerol Ester Synthesized by Solid Acid Catalysts (고체산 촉매를 이용해 합성한 diglycerol ester의 전기절연 특성 및 평가)

  • Gwon, Miseong;Baek, Jae Ho;Kim, Myung Hwan;Park, Dae-Won;Lee, Man Sig
    • Applied Chemistry for Engineering
    • /
    • v.25 no.3
    • /
    • pp.254-261
    • /
    • 2014
  • The transformer is a static electrical device that transfers energy by inductive coupling. Then, heat is occurred at coils, inner transformer was filled with insulating oils for cooling and insulation. Although mineral oil as insulating oil has been widely used, it does not meet health and current environmental laws because it is not biodegradable. Therefore, in this study, the diglycerol ester was synthesized with diglycerol and fatty acids (oleic acid and caprylic acid) over various catalysts for insulating oil having biodegradability, high flash points and low pour points. The sulfated zirconia ($SO_4{^{2-}}/ZrO_2$) catalyst prepared at different calcination temperature shows the highest conversion of fatty acids at $600^{\circ}C$ due to crystallinity and high density of acid sites per surface area. When the molar ratio of oleic acid and caprylic acid is 1:3, the diglycerol ester shows superior insulation properties that are the flash point of $306^{\circ}C$ and pour point of $-50^{\circ}C$. The insulation properties of synthesized diglycerol ester shows the pour point of $-50^{\circ}C$ and the flash point of over $300^{\circ}C$. Therefore, diglycerol ester is superior to the vegetable oils in insulation properties.

DUAL BAND SLOT COUPLED MULTIPLE PATCH ANTENNA WITH BROAD BANDWIDTH AND HIGH DIRECTIVITY FOR WIRELESS ACCESS POINT (무선 액세스 포인트용 광대역의 고지향성 이중대역 슬롯 결합 다중 패치안테나)

  • Yeom, Insu;Kang, Seonghun;Jung, Changwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.3074-3078
    • /
    • 2014
  • We implemented a dual-band slot-coupled patch (SCP) antenna for the external access point (AP) of the wireless local area network (WLAN) band. The antennas consist of two radiators on three layers. The first radiator is a slotted bow tie antenna operating at the 2.4-2.483 GHz band. The second radiator is a patch antenna with parasitic elements operating at 4.095-5.845 GHz. The high gain and broad bandwidth is important element of wireless access. To enhance the bandwidth, a coupled feeding was used in the first radiator and a parasitic patch was used in the second radiator. We used a parasitic patch and chock to improve the directivity and isolation in both radiators. The porposed antenna was designed by EM simulation tool and measured. The S11 of the antenna was less than -11dB (VSWR 1.8:1) at operating frequency. The peak gain was more than 6 dBi in the first antenna and more than 8 dBi in the second antenna.

Implementation and Characteristic Analysis of DC/DC Voltage Regulator for Operation Efficiency Improvement in PV system (태양광발전의 운용효율 향상을 위한 DC/DC 전압 레귤레이터의 구현 및 특성분석)

  • Kim, Chanhyeok;Choi, Sungsik;Kang, Minkwan;Jung, Youngmun;Rho, Daeseok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.201-208
    • /
    • 2017
  • Recently, the installation of photovoltaic(PV) systems has been increasing due to the worldwide interest in eco-friendly and abundant solar energy. On the other hand, a PV system has approximately 25% power loss while the energy generated from solar cells is transformed to the power coupling point through a power conversion system (DC/AC). If the output voltage of a string in the PV system is lower than the operating range of the inverter when a part of module in the string has a shadow due to weather conditions, the string is not synchronized and the whole efficiency of output power in a PV system may be reduced significantly. Therefore, to overcome this problem, this paper proposes a novel control method to compensate for the lower voltage by introducing a DC/DC voltage regulator for each string in a PV system, which adopts a concept for MPPT (Maximum Power Point Tracking) control function using the P&O algorithm and adopts constant voltage control method used in an existing inverter. This paper also implements a 2kW DC/DC voltage regulator based on the proposed algorithm and performs a variety of scenario-based experiments. From the simulation result, it was confirmed that the operation efficiency in the proposed method is improved compared to the existing method.

The Effects of Polymerization Catalyst Systems on the Synthesis of Poly(2,6-dimethyl-1,4-phenylene ether) (중합촉매 시스템이 폴리페닐렌에테르의 합성에 미치는 영향)

  • Lee, Chang-Jae;Kim, Yong-Tae;Kim, Jin-Kyu;Kim, Ji-Heung;Nam, Sung-Woo;Jeon, Boong-Soo;Kim, Young-Jun
    • Polymer(Korea)
    • /
    • v.36 no.1
    • /
    • pp.98-103
    • /
    • 2012
  • Poly(2,6-dimethyl-1,4-phenylene ether) (PPE) was synthesized using $Cu(NO_2)_2{\cdot}3H_2O$ or CuCl catalyst with various amounts of ligand and base in several different solvent systems. CuCl/1-methylimidazole/ammonium hydroxide was found to be an effective catalyst system which showed the highest polymer yield and molecular weight. The effects of catalyst/monomer ratio, different amine ligands, and the content of mono-functional reagent 2,4,6-trimethylphenol (TMP) additive on the polymer yield and molecular weight were investigated. Among the co-solvent systems used in this polymerization, chloroform/methanol 9/1(v/v) gave the highest polymer yield and molecular weight ($\overline{M_n}$ 55 K, $\overline{M_w}$ 92 K, PDI 1.7). The catalytic activity between CuCl and CuI was compared by oxygen-uptake experiments and the formation of sideproduct, 5,5'-tetramethyl-4,4'-diphenoquinone (DPQ), was analyzed by ultraviolet spectroscopy.

Magnetoresistance Properties of Spin Valves Using MoN Underlayer (MoN 하지층을 이용한 스핀밸브의 자기저항 특성)

  • Kim, Ji-Won;Jo, Soon-Chul;Kim, Sang-Yoon;Ko, Hoon;Lee, Chang-Woo
    • Journal of the Korean Magnetics Society
    • /
    • v.16 no.5
    • /
    • pp.240-244
    • /
    • 2006
  • In this paper, magnetic properties and annealing behavior of spin valve structures using Mo(MoN) layers as underlayers were studied varying the thickness of the underlayers. The spin valve structure was consisted of Si substrate/$SiO_2(2,000{\AA})/Mo(MoN)(t{\AA})/NiFe(21\;{\AA})/CoFe(28\;{\AA})/Cu(22\;{\AA})/CoFe(18\;{\AA})/IrMn(65\;{\AA})/Ta(25\;{\AA})$. Also, MoN films were deposited on Si substrates and their thermal annealing behavior was analyzed. The resistivity of the MoN film increased as the $N_2$ gas flow rate was increased. After annealing at $600^{\circ}C$, XRD results did not show peaks of silicides. XPS results indicated MoN film deposited with 5 sccm of $N_2$ gas flow rate was more stable than the film deposited with 1 sccm of $N_2$ gas flow rate. The variations of MR ratio and magnetic exchange coupling fold were small for the spin valve structures using Mo(MoN) underlayers up to thickness of45 ${\AA}$. MR ratio of spin valves using MoN underlayers deposited with various $N_2$ gas flow rate was about 7.0% at RT and increased to about 7.5% after annealing at $220^{\circ}C$. Upon annealing at $300^{\circ}C$, the MR ratio decreased to about 3.5%. Variation of $N_2$ gas flow rate up to 5 sccm did not change the MR ratio and $H_{ex}$ appreciably.

Characteristics of the Angular-dependent Exchange Coupling Bias in Multilayer [Pt/Co]N-IrMn with Toward-in Plane Applied Fields (박막수직방향에서 면방향으로 회전하는 인가자기장에 대한 다층박막 [Pt/Co]N-IrMn의 교환바이어스의 각도의존특성)

  • Kim, S.S.;Yim, H.I.;Rhee, J.R.;Lee, S.S.;Hwang, D.G.
    • Journal of the Korean Magnetics Society
    • /
    • v.18 no.4
    • /
    • pp.142-146
    • /
    • 2008
  • The angular dependence of the exchange bias($H_{ex}$) and coercivity($H_c$) in multilayer $[Pt/Co]_N-IrMn$ with applied measuring field rotated toward in-plane at angle $\theta$ from perpendicular-to-plane, has been measured. Multilayer films consisting of $Si/SiO_2/Ta(50)/Pt(4)/[Pt(15)/Co(t_{Co})]_N/IrMn(50)/Ta(50)(in\;{\AA})$ were prepared by magnetron sputtering under typical base pressure below $2{\times}10^{-8}$ Torr at room temperature. Magnetization measurements were performed on a vibrating sample magnetometer and extraordinary Hall voltage measurement systems after cooling from 550 K under a field of 2 kOe applied along the perpendicular to film direction. The hysteresis loop shifts from the origin not only along the field axis but also along the magnetization axis. $H_{ex}$ and $H_c$ show a $1/cos{\theta}$ and $1/|cos{\theta}|$ dependence on the angle($\theta$) between the applied measuring field and the perpendicular-film direction, respectively. This $1/cos{\theta}$ dependence can be accounted for by considering the angular dependence of strong out-of-plane magnetic anisotropy introduced during the field cooling.

Synthesis and Characterization of Composite Paper Using Polyamide Fiber and Surface Modified Microfibrillated Cellulose (표면 개질된 마이크로피브릴화 셀룰로오스를 이용한 폴리아마이드 섬유와의 복합페이퍼 제조 및 특성평가)

  • Lee, Jong-Hee;Lim, Jung-Hyurk;Kim, Ki-Young;Kim, Kyung-Min
    • Polymer(Korea)
    • /
    • v.38 no.1
    • /
    • pp.74-79
    • /
    • 2014
  • Microfibrillated cellulose (MFC) was chemically modified with two different silane coupling agents (3-aminopropyltriethoxysilane and 3-mercaptopropyltriethoxysilane) and lauroyl chloride. The surface modification of MFC was confirmed by infrared spectroscopy (FTIR), energy dispersive X-ray spectroscopy (EDX), and contact angle measurements. Composite paper was successfully prepared with surface modified MFC and polyamide (PA) fiber. The surface modification of MFC not only prevented aggregation of MFC but also improved adhesive property between PA fiber and surface modified MFC. It was impossible to prepare papers of only PA fiber because there is no binder to connect PA fibers. That is, surface modified MFC as a binder in PA fiber played a crucial role in making composite paper. Composite paper with silane modified MFC showed higher tensile strength and modulus than composite paper with lauroyl moiety modified MFC. The structure, morphology, and mechanical properties of composite paper were analyzed by scanning electron microscope (SEM) and universal testing machine (UTM).

Wind load and wind-induced effect of the large wind turbine tower-blade system considering blade yaw and interference

  • Ke, S.T.;Wang, X.H.;Ge, Y.J.
    • Wind and Structures
    • /
    • v.28 no.2
    • /
    • pp.71-87
    • /
    • 2019
  • The yaw and interference effects of blades affect aerodynamic performance of large wind turbine system significantly, thus influencing wind-induced response and stability performance of the tower-blade system. In this study, the 5MW wind turbine which was developed by Nanjing University of Aeronautics and Astronautics (NUAA) was chosen as the research object. Large eddy simulation on flow field and aerodynamics of its wind turbine system with different yaw angles($0^{\circ}$, $5^{\circ}$, $10^{\circ}$, $20^{\circ}$, $30^{\circ}$ and $45^{\circ}$) under the most unfavorable blade position was carried out. Results were compared with codes and measurement results at home and abroad, which verified validity of large eddy simulation. On this basis, effects of yaw angle on average wind pressure, fluctuating wind pressure, lift coefficient, resistance coefficient,streaming and wake characteristics on different interference zone of tower of wind turbine were analyzed. Next, the blade-cabin-tower-foundation integrated coupling model of the large wind turbine was constructed based on finite element method. Dynamic characteristics, wind-induced response and stability performance of the wind turbine structural system under different yaw angle were analyzed systematically. Research results demonstrate that with the increase of yaw angle, the maximum negative pressure and extreme negative pressure of the significant interference zone of the tower present a V-shaped variation trend, whereas the layer resistance coefficient increases gradually. By contrast, the maximum negative pressure, extreme negative pressure and layer resistance coefficient of the non-interference zone remain basically same. Effects of streaming and wake weaken gradually. When the yaw angle increases to $45^{\circ}$, aerodynamic force of the tower is close with that when there's no blade yaw and interference. As the height of significant interference zone increases, layer resistance coefficient decreases firstly and then increases under different yaw angles. Maximum means and mean square error (MSE) of radial displacement under different yaw angles all occur at circumferential $0^{\circ}$ and $180^{\circ}$ of the tower. The maximum bending moment at tower bottom is at circumferential $20^{\circ}$. When the yaw angle is $0^{\circ}$, the maximum downwind displacement responses of different blades are higher than 2.7 m. With the increase of yaw angle, MSEs of radial displacement at tower top, downwind displacement of blades, internal force at blade roots all decrease gradually, while the critical wind speed decreases firstly and then increases and finally decreases. The comprehensive analysis shows that the worst aerodynamic performance and wind-induced response of the wind turbine system are achieved when the yaw angle is $0^{\circ}$, whereas the worst stability performance and ultimate bearing capacity are achieved when the yaw angle is $45^{\circ}$.

Magnetoresistance Effects of Magnetic Tunnel Junctions with Amorphous CoFeSiB Single and Synthetic Antiferromagnet Free Layers (비정질 CoFeSiB 단일 및 합성형 반강자성 자유층을 갖는 자기터널접합의 자기저항 효과)

  • Hwang, J.Y.;Kim, S.S.;Rhee, J.R.
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.6
    • /
    • pp.315-319
    • /
    • 2005
  • To obtain low switching field ($H_{SW}$) we introduced amorphous ferromagnetic $Co_{70.5}Fe_{4,5}Si_{15}B_{10}$ single and synthetic antiferromagnet (SAF) free layers in magnetic tunnel junctions (MTJs). The switching characteristics for MTJs with structures $Si/SiO_2/Ta$ 45/Ru 9.5/IrMn 10/CoFe 7/AlOx/CoFeSiB 7 or CoFeSiB (t)/Ru 1.0/CoFeSiB (7-t)/Ru 60 (in nm) were investigated and compared to MTJs with $Co_{75}Fe_{25}$ and $Ni_{80}Fe_{20}$ free layers. CoFeSiB showed a lower saturation magnetization of $560 emu/cm^3$ and a higher anisotropy constant of $2800\;erg/cm^3$ than CoFe and NiFe, respectively. An exchange coupling energy ($J_{ex}$) of $-0.003erg/cm^2$ was observed by inserting a 1.0 nm Ru layer in between CoFeSiB layers. In the CoFeSiB single and SAF free layer MTJs, it was frond that the size dependence of the $H_{SW}$ originated from the lower $J_{ex}$ experimentally and by micromagnetic simulation based on the Landau-Lisfschitz-Gilbert equation. The CoFeSiB SAF structures showed lower $H_{SW}$ than that of NiFe, CoFe and CoFeSiB single structures. The CoFeSiB SAF structures were proved to be beneficial far the switching characteristics such as reducing the coercivity and increasing the sensitivity in micrometer to submicrometer-sized elements.

Shear bond strength of rebonded ceramic brackets (세라믹 브라켓의 재접착이 전단 결합 강도에 미치는 영향)

  • Sung, Ji-Young;Kang, Kyung-Hwa
    • The korean journal of orthodontics
    • /
    • v.39 no.4
    • /
    • pp.234-247
    • /
    • 2009
  • Objective: The purpose of this study was to evaluate the shear bond strength of rebonded ceramic brackets according to each condition and find an appropriate method to rebond ceramic brackets with proper shear bond strength in clinical practice. Methods: The study consisted of 12 experimental groups, according to the types of brackets, debonding methods, and treatment methods of the bracket base. Shear bond strength was measured, and adhesive residues left on the tooth surface were assessed. The base of the bracket was examined under scanning electron microscopy. Results: The shear bond strength of the monocrystalline ceramic bracket group was significantly higher than thatof the polycrystalline bracket group with only sandblasting (p < 0.05). There was no significant difference in shear bond strength between groups that used rebonded brackets which were debonded with shear force and debonded with laser (p > 0.05). The shear bond strength of the sandblasted/silane group was significantly higher than that of the selectively grinded group with a low-speed round bur and the sandblasted only group (p < 0.001). The retentive structure was more presented in groups where laser was applied than in groups where shear force was applied to debond brackets prior to rebonding. The bracket bases which were treated before rebonding presented smoother surfaces than new brackets. Conclusions: Shear bond strength could be increased by applying a silane coupling agent after sandblasting before rebonding. Also, the bond strength of the selectively grinded group with a low-speed round bur and the sandblasted group showed acceptable bond strength for clinical orthodontic treatment.