• Title/Summary/Keyword: Y-coupling

Search Result 6,745, Processing Time 0.032 seconds

Alternative Expressions for Mutual Inductance and Coupling Coefficient Applied in Wireless Power Transfer

  • Kim, Gunyoung;Lee, Bomson
    • Journal of electromagnetic engineering and science
    • /
    • v.16 no.2
    • /
    • pp.112-118
    • /
    • 2016
  • Alternative analytic expressions for the mutual inductance ($L_m$) and coupling coefficient (k) between circular loops are presented using more familiar and convenient expressions that represent the property of reciprocity clearly. In particular, the coupling coefficients are expressed in terms of structural dimensions normalized to a geometric mean of radii of two loops. Based on the presented expressions, various aspects of the mutual inductances and coupling coefficients, including the regions of positive, zero, and negative value, are examined with respect to their impacts on the efficiency of wireless power transmission.

A Miniaturized Aperture-Coupled Multilayer Hairpin Bandpass Filter

  • Moon, Han-Ul;Choi, Seung-Un;Yun, Sang-Won
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.1
    • /
    • pp.12-16
    • /
    • 2008
  • In this paper, we introduce a coupling, which is achieved through the aperture instead of the conventional edge coupling, so that the bandpass filter is reduced less than half in size compared to conventional planar type. The resulting filter configuration has a near two-fold symmetry, where the aperture coupling is used in the middle of the coupling stages. We designed a bandpass filter using two tapped hairpin resonators, of which the order becomes four. The designed bandpass filter has the size of $8.9{\times}18.3\;mm$. It has the return loss better than 17dB and the insertion loss of less than 5 dB in overall passband. The measured results show good agreements with simulated ones.

6.78MHz Capacitive Coupling Wireless Power Transfer System

  • Yi, Kang Hyun
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.987-993
    • /
    • 2015
  • Wireless power transfer technologies typically include inductive coupling, magnetic resonance, and capacitive coupling methods. Among these methods, capacitive coupling wireless power transfer (CCWPT) has been studied to overcome the drawbacks of other approaches. CCWPT has many advantages such as having a simple structure, low standing power loss, reduced electromagnetic interference (EMI) and the ability to transfer power through metal barriers. In this paper, the CCWPT system with 6.78MHz class D inverter is proposed and analyzed. The proposed system consists of a 6.78MHz class D inverter with a LC low pass filter, capacitor between a transmitter and a receiver, and impedance transformers. The system is verified with a prototype for charging mobile devices.

Design of Three-winding Coupled Inductor for Minimum Current Ripple in Battery Chargers

  • Kang, Taewon;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.195-196
    • /
    • 2015
  • This paper investigates the design of coupled inductor for minimum inductor current ripple in rapid traction battery charger systems. Based on the general circuit model of coupled inductor together with the operating principles of dc-dc converter, the relationship between the ripple size of inductor current and the coupling factor is derived under the different duty ratio. The optimal coupling factor which corresponds to a minimum inductor ripple current becomes -0.5, i.e. a complete inverse coupling without leakage inductance, as the steady-state duty ratio operating point approaches 1/3 or 2/3. In an opposite manner, the optimal coupling factor value of zero, i.e. zero mutual inductance, is required when the steady-state duty ratio operating point approaches either zero or one. Coupled inductors having optimal coupling factor can minimize the ripple current of inductor and battery current resulting in a reliable and efficient operation of battery chargers.

  • PDF

Study on Reliability Evaluation for a Taper Grid Coupling (테이퍼 그리드 커플링의 신뢰성 평가에 관한 연구)

  • Jung, Dong Soo
    • Journal of Applied Reliability
    • /
    • v.17 no.4
    • /
    • pp.343-354
    • /
    • 2017
  • Purpose: This paper evaluates the reliability of tapered grid couplings and presents test results through performance and life tests. Methods: The performance and life test method were presented by analyzing the failure modes for the tapered grid coupling. Zero failure test time was calculated to evaluate the reliability of tapered grid couplings and the test was performed under accelerated conditions. The nondestructive test and wear analysis using weighing were also carried out to check the failure modes of the field conditions. Conclusion: This study can be provided to improve the product reliability through failure analysis of a tapered grid coupling. The performance test results of before and after the accelerated life test were presented to confirm the improved reliability of the tapered grid coupling.

Side-Coupled Asymmetric Plastic Optical Fiber Coupler for Optical Sensor Systems

  • Kim, Kwang-Taek;Kim, Deok-Gi;Hyun, Woong-Keun;Hong, Ki-Bum;Im, Kie-Gon;Baik, Se-Jong;Kim, Dae-Kyong;Choi, Hyun-Yong
    • Journal of the Optical Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.255-261
    • /
    • 2008
  • This paper reports a side-coupled asymmetric $1{\times}2$ plastic optical fiber coupler for an optical sensor system. The dependence of the optical power coupling ratio on the coupling angle and refractive index of the adhesion layer in both the forward and backward directions was examined based on the geometrical optics. It was confirmed experimentally that the coupling ratios can be optimized by controlling the coupling angle and refractive index of the adhesion layer. A maximum forward coupling efficiency > 93% was achieved.

A Study on the Characteristics of Directional Coupler by BPM (BPM에 의한 방향성 결합기의 특성 연구)

  • 장지호;최태일;최병하
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.7
    • /
    • pp.951-958
    • /
    • 1993
  • The coupling length is very important factor for the study of directional coupler and other intergrated-optic devices. And the calculation of coupling length is the fundamental process of studing various types of intergrated optical devices. But the calculation of coupling length, requires coupling coefficient n. and the evaluation of coupling coefficient f is very tedious because it requires the calculation of overlap intergral of the two modes. Because of above reason, we suggest the use of beam propagation method, We suggest the basic configuration of directional coupler, which has three different types of longitudinal to vertical ratio, and calculate the coupling length of sugested configuration by both coupled mode thery and beam propagation method and compare the results of each method.

  • PDF

Magnetic Exchange Coupling at The Interface of MR/TbCo Thin Films (자기저항 헤드용 MR/TbCo 박막의 자기교환 결합)

  • 서정교;조순철
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.1
    • /
    • pp.1-6
    • /
    • 1996
  • To simulate the characteristics of magnetic exchange coupling at the interface of MR/TbCo thin films, the directions of magnetizations were calculated by minimizing energy in the films. Newton method and Gauss-Seidel method were used. The width of M-H curve increased with TbCo anisotropy constant, and with the thickness of the transition region of TbCo layer. Hysteresis loop width became extremely narrow (less than 10 Oe of coercivity), when the TbCo transition region length was $400\;\AA$. Also the hysteresis loop of films with low interfacial exchange coupling constant was similiar to that of short transition region length. When interfacial exchange coupling constant was 1/100 of perfect coupling, hysteresis loop showed a coercivity of less than 10 Oe. Comparing the measured hysteresis loop of a fabricated sample with that of simulated one, exchange coupling con¬stant could be estimated.

  • PDF

The Effect of the Ligand's Spin-Orbit Coupling on the Zero-Field Splitting in the Low Spin Octahedral Ti(Ⅲ), V(Ⅲ), Fe(Ⅲ) and Ni(Ⅱ) Complexes (리간드의 Spin-Orbit Coupling이 작은 스핀팔면체 Ti(Ⅲ), V(Ⅲ), Fe(Ⅲ) 및 Ni(Ⅱ) 착물의 Zero-Field Splitting에 미치는 영향)

  • Ahn Sangwoon;Lee Kee Hag
    • Journal of the Korean Chemical Society
    • /
    • v.23 no.2
    • /
    • pp.65-74
    • /
    • 1979
  • An effect of the spin-orbit coupling interaction of ligand orbitals on the ground state for octahedral $[Ti(Ⅲ)A_3B_3]$, $ [V(Ⅲ)A_3B_3]$, $ [Fe(Ⅲ)A_3B_3]$ and $ [Ni(Ⅱ)A_3B_3]$ type complexes has been investigated in this work, applying the degenerate perturbation theory. The wave functions are not affected but the energy level splitting for the ground state of these complexes by the spin-orbit coupling interaction of ligand orbitals. The extent of effect on the energy level splitting for the ground state is decreased in order Ti(Ⅲ) > V(Ⅲ) > Fe(Ⅲ).

  • PDF

Analysis of Crosstalk-Induced Variation of Coupling Capacitance between Interconnect lines in High Speed Semiconductor Devices (고속 반도체 소자에서 배선 간의 Crosstalk에 의한 Coupling Capacitance 변화 분석)

  • Ji Hee-Hwan;Han In-Sik;Park Sung-Hyung;Kim Yong-Goo;Lee Hi-Deok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.5 s.335
    • /
    • pp.47-54
    • /
    • 2005
  • In this paper, novel test patterns and on-chip data are presented to indicate that the variation of coupling capacitance, ${\Delta}Cc$ by crosstalk can be larger than static coupling capacitance, Cc. It is also shown that ${\Delta}Cc$ is strongly dependent on the phase of aggressive lines. for anti-phase crosstalk ${\Delta}Cc$ is always larger than Cc while for in-phase crosstalk ${\Delta}Cc$ is smaller than Cc. HSPICE simulation shows good agreement with the measurement data.