• Title/Summary/Keyword: Y-Stent

Search Result 472, Processing Time 0.029 seconds

Hybrid Procedure for Pulmonary Atresia with Ventricular Septal Defect in a Low Birth Weight Neonate

  • Park, Ji Young;Seo, Dong-Man;Shin, Hong Ju;Kim, Soo-Jin;Son, Jae Sung
    • Journal of Chest Surgery
    • /
    • v.46 no.1
    • /
    • pp.56-59
    • /
    • 2013
  • Cardiac surgery in neonates with congenital heart disease has progressed dramatically in the past three decades. However, low-birth-weight neonates with congenital heart disease continue to challenge the intellectual and technical skills of healthcare professionals. We present a case of a low-birth-weight neonate with pulmonary atresia and a ventricular septal defect, in whom palliation was achieved with a right ventricular outflow tract stent using a hybrid procedure.

Delayed Type III Endoleak Caused by Fabric Erosion after Endovascular Repair of an Abdominal Aortic Aneurysm

  • Lee, Jae Hang;Kim, Eung-joong;Choi, Jin-Ho
    • Journal of Chest Surgery
    • /
    • v.50 no.4
    • /
    • pp.291-294
    • /
    • 2017
  • A 74-year-old patient presented with recurrent aneurysms in the infrarenal abdominal aorta and right common iliac artery 6 years after endovascular aortic repair using endografts in the same location. The patient underwent an aorto-bi-iliac replacement with removal of the stent graft. Two holes measuring 2 mm each were found in the removed graft, and they appeared to have been caused by wear from continuous friction between the endograft and the aortic wall.

Endovascular Treatment of Blood Blister-Like Aneurysms Using Multiple Self-Expanding Stents

  • Kim, Young-Woo;Park, Ik-Seong;Baik, Min-Woo;Jo, Kwang-Wook
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.2
    • /
    • pp.116-119
    • /
    • 2011
  • The surgical as well as endovascular treatment of blood-blister-like aneursysms (BBAs) is extremely difficult because of these pathological natures, such as small and the fragile necks. The optimal treatment of BBAs has remained uncertain. Stents are known to divert blood flow and induce thrombosis of intracranial aneurysms. We report 3 cases of successful obliteration of BBAs after multiple stents placement.

Congenital Pulmonary Vein Stenosis with Normal Anatomical Connection -One case report- (정상적인 해부학적 연결을 가진 선천성 폐정맥 협착증 -치험 1예 보고-)

  • 박준석;장윤희;정미진;강이석;전태국
    • Journal of Chest Surgery
    • /
    • v.37 no.4
    • /
    • pp.364-368
    • /
    • 2004
  • Congenital pulmonary vein stenosis is a rare anomaly and related to high mortality due to progressive pulmonary hypertension and heart failure in infancy. Aggressive anti-failure medication and surgical treatment is recommended. Surgical options are balloon dilatation, endovascular stent, pneumonectomy, lung transplantation, patch grafting, and sutureless repair. We report a case of congenital pulmonary vein stenosis with normal anatomical connection successfully treated with sutureless technique and using pulmonary vasodilators, such as Sildenafil, lloprost and iNO postoperatively.

Perforated Afferent Loop Syndrome in a Patient with Recurrent Gastric Cancer: Non-Surgical Treatment with Percutaneous Transhepatic Duodenal Drainage and Endoscopic Stent (재발된 위암 환자에서 발생한 천공성 수입각 증후군의 비수술적 치료)

  • Song Kyo Young;Son Chang Hee;Park Cho Hyun;Kim Seung Nam
    • Journal of Gastric Cancer
    • /
    • v.4 no.3
    • /
    • pp.176-179
    • /
    • 2004
  • Surgical treatment for afferent loop syndrome (ALS) in patients with recurrent gastric cancer is usually not feasible because of the recurrent tumor mass at the anastomosis site and/or extensive carcinomatosis resulting in bowel loop fixation. Furthermore, ALS usually makes oral intake impossible, resulting in a rapid deterioration in general condition. In this situation, gastroscopic stenting at the anastomotic site and/or percutaneous external drainage may be a more feasible alternative for palliation. We herein report a recurrent gastric cancer whose ALS was successfully treated with internal and external drainage procedures.

  • PDF

A Simple Surgical Guide for Horizontal Bone Graft: A Technical Note

  • Ahn, Kang-Min
    • Journal of International Society for Simulation Surgery
    • /
    • v.3 no.2
    • /
    • pp.90-92
    • /
    • 2016
  • Horizontal bone defect in the anterior maxilla makes it difficult to place dental implant. The golden standard for bone augmentation is autogenous block bone graft. Tight contact with recipient site and rigid fixation are two key factors for successful block bone graft. Ramal bone graft has been the most reliable methods for dental implant field. However, the curvature of the alveolar ridge is different from ramal bone shape. Intraoperative trimming of ramal bone is cumbersome for surgeon. In this technical note, a simple way to design the ramal bone harvest using bone wax stent is reviewed.

A Comparative Study of the Hemodynamic Hypotheses for the Generation of Atherosclerosis (동맥경화증의 발생에 관한 혈류역학적 가설들에 대한 비교연구)

  • Suh, Sang-Ho;Cho, Min-Tae;Roh, Hyung-Woon;Kwon, Hyuck-Moon
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1915-1918
    • /
    • 2003
  • Atherosclerosis, which is a degenerate disease, is believed to occur in the vascular system due to deposition of cholesterol and low density lipoprotein(LDL) or thrombosis on the blood vessel. Atherosclerosis narrows arterial lumen, which is known as stenosis phenomenon of blood vessel. Pathogenesis of atherosclerosis is thought to occur mainly by aging. Restenosis phenomenon is observed in the same site of insertion of a stent and balloon angioplasty after treatment of interventional theraphy. Several hypothetical theories related to the generation of atherosclerosis have been reported: high shear stress theory, low shear stress theory, high shear stress gradient theory, flow separation and turbulence theory and high pressure theory. However, no one theory clearly explains the causes of atherosclerosis. In the present study the generation of atherosclerosis in the left coronary artery is investigated. The hypotheses are verified by using the computer simulation.

  • PDF

CBCT analysis of three implant cases for treatment planning (임플란트 치료 전 CBCT 영상분석 세 증례)

  • Kim, Jae-Duk;Kim, Kwang-Won;Lim, Sung-Hoon
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.171-180
    • /
    • 2007
  • The role of radiographic imaging in determining the size, numbers and the position of implants is very important. To perform the implant procedure, the dentist needs to evaluate the bone pathology and bone density, and to know the precise height, width, and contour of the alveolar process, as well as its relationship to the maxillary sinus and mandibular canal. The author analyzed 3 implant cases for treatment planning with the cone beam CT. All axial, panoramic, serial and buccolingual-sectioned images of 3 cases with stent including vertical marker were taken by using Mercuray (Hitachi, Japan). When the curved line drawn intentionally did not include dot image of a vertical marker on the axial image of CBCT, the image of the vertical marker was deformed on its buccolingually sectioned image. There was wide discrepancy in inclination between the alveolar bone and tooth on buccolingually sectioned image.

  • PDF

A Study of Micro Electrolytic-deburring for Nitinol (Nitinol 소재의 미세 전해디버링에 관한 연구)

  • Kim W.M.;Sin M.J.;Lee E.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.229-230
    • /
    • 2006
  • Shape memory alloy, Nitinol is used for medical stent, artificial human joint, antenna of artificial satellite, fire door, temperature sensor...etc. It is important for some nitinol product high precision and clean surface. In this study, we experiment about deburring of edge and surface of nitinol work piece with micro electrolytic-deburring. We made an observation in case electric currents are $1A{\sim}4A$, above 5A and each machining times.

  • PDF