• 제목/요약/키워드: XPS.

검색결과 2,180건 처리시간 0.024초

Application of X-ray photoelectron spectroscopy (XPS) in ionic liquids

  • 박주연;서초현;서성용;강용철
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2015년도 제49회 하계 정기학술대회 초록집
    • /
    • pp.117-117
    • /
    • 2015
  • Availability of X-ray photoelectron spectroscopy (XPS) for the identification of ionic liquids (ILs) was tested. Commercially available ionic liquids (1-butyl-3-methyl imidazolium tetrafluoroborate ([BMIM] $BF_4$), (1-butyl-3-methyl imidazolium trifluoromethanesulfonate ([BMIM] OTf), (1-butyl-3-methyl imidazolium hexafluorophosphate ([BMIM] $PF_6$), 1-hexyl-3-imidazolium hexafluorophosphate ([HMIM] $PF_6$), and 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([EMIM] $Tf_2N$) were qualitatively and semi-quantitatively analyzed with XPS. In order to confirm whether the results of XPS were correct, conventional method such as a nuclear magnetic resonance (NMR) was performed. After the XPS results were convinced by NMR, we synthesized ILs (1-(4-sulfonic acid) butyl-3-butylimidazolium trifluoromethanesulfonate ([SBBIM] OTf), 1-(4-sulfonic acid) propyl-3-methylimidazolium trifluoromethanesulfonate ([SPMIM] OTf), and 1-(4-sulfonic acid) propyl-3-butylimidazolium trifluoromethanesulfonate ([SPBIM] OTf) and analyzed it with XPS and NMR as well. It was successful the usage of XPS to analyze ILs without any purification processes.

  • PDF

XPS® Microresector(Shaver)를 이용한 액취증 수술 (XPS® Microresector for Treatment of Axillary Osmidrosis)

  • 한병기;박성욱;송재용;김정헌
    • Archives of Plastic Surgery
    • /
    • 제35권5호
    • /
    • pp.569-573
    • /
    • 2008
  • Purpose: Surgical excision of the subcutaneous tissues, with or without skin excision in the axillary hair-bearing area, has been the treatment of choice in treating osmidrosis for several decades. However, long periods of postoperative immobilization of a shoulder joint, partial necrosis of skin flaps or the possibility of hematoma and scars have occurred frequently. So we used $XPS^{(R)}$ microresector(Shaver) in procedure which requires removal of soft tissue for comparing results between surgical excision and the laters. Methods: From January 2007 to February 2008, a total of 20 patients(8 male and 12 female) underwent $XPS^{(R)}$ microresector(Shaver) assisted aspiration for treating osmidrosis. The mean age of the subjects was 21.9, and we tried to analyze some advantages of $XPS^{(R)}$ microresector(Shaver). Results: The average operation time was 61.6 minutes. This results can show that the patients who received $XPS^{(R)}$ microresector(Shaver) assisted aspiration can accomplish better outcomes than any other procedures in terms of operation time at least. Moreover, no significant postoperative complications occurred in our studies. Subjects have been followed up from 2 months to 1 year and among these patients, no one suffered from critical complications. Conclusion: In brief, $XPS^{(R)}$ microresector(Shaver) is able to shorten the time of operation and simplify the procedures relatively and this device has more superiorities in wound healing by maintaining of vascularized dermal skin flaps. It means that $XPS^{(R)}$ microresector (Shaver) can prevent flap necrosis, axillary hair loss and minimalize scarring and bleeding. Thus, we expect that these advantages can lead to better patient's comfort and self-confidence than several previous procedures.

XPS® microresector(Shaver)를 이용한 여성형 유방증 수술 (The Treatment of gynecomastia using XPS® Microresector(Shaver))

  • 송재용;한병기;김정헌
    • Archives of Plastic Surgery
    • /
    • 제36권6호
    • /
    • pp.806-810
    • /
    • 2009
  • Purpose: Gynecomastia is an abnormal increase in the volume of the male breast. Subcutaneous mastectomy was the first surgical treatment for gynecomastia. But because of the complications such as nerve injury and scar formation, subcutaneous mastectomy has been substituted with liposuction. Recently various techniques including ultrasound - assisted liposuction has been used for treatment of gynecomastia. The purpose of this study is to evaluate the results of XPS$^{(R)}$ microresector(Shaver) for treatment of gynecomastia. Methods: 17 patients, 33 breasts of gynecomastia, Simon grade I or II have been treated with XPS$^{(R)}$ microresector(Shaver). The mean age was 24.5. The subcutaneous tissue and glandular tissue were removed with XPS$^{(R)}$ microresector(Shaver). The operation time, the weight of removed tissue and patients' satisfaction score were accessed. Results: The mean operation time was 78.2 minutes. The mean weight of removed tissue was 113.8 g. There was no significant complications such as necrosis, hematoma, infection or scar contracture. Patients' satisfactory score of scar, shape and confidence were 8.4, 8.2 and 8.4 respectively. As the average score was 8.3, almost patients were satisfied with their breasts. Conclusion: The authors have treated 17 patients suffering from gynecomastia with XPS$^{(R)}$ microresector(Shaver). We obtained short operation time, early recovery, minimal operative scar and less complications with XPS$^{(R)}$ microresector(Shaver) for the treatment of gynecomastia, and patients were satisfied with the results of our method. We concluded XPS$^{(R)}$ microresector(Shaver) is an alternative option for the treatment of gynecomastia.

철도에서의 동상방지를 위한 모형시험에서 XPS 및 PE골재의 설치 효과 (Effect of XPS and Polyethylene Aggregates in Model Tests for Prevention of Frost Heave in Railroad Track)

  • 김동관;윤여원;김영진
    • 한국지반환경공학회 논문집
    • /
    • 제15권10호
    • /
    • pp.5-13
    • /
    • 2014
  • 본 연구에서는 철도노반에서의 동결융해로 인한 피해를 줄이고자 뛰어난 단열효과와 강도를 가진 XPS(eXtruded PolyStyrene)와 PE골재(polyethylene aggregates)를 사용하여 동상을 억제하는 방법을 연구하고자 대형동토실에서 모형시험을 수행하였다. 이를 위해 노반과 PE골재의 혼입비율을 변화시켜 건조밀도와 함수비, 온도에 따른 열전도율을 측정하였다. 시험결과 노반에 혼입된 PE골재 비율에 비례하여 단열효과가 증가하였지만, 간극의 함수비와 온도변화에 민감하였다. 또한 철도노반을 모사한 모형시험에서 각 단열재의 두께와 설치순서를 다르게 한 후 단열효과를 비교 결과, XPS의 단열효과가 우수한 것으로 나타났으며 XPS판자가 상부, PE골재가 하부에 설치될 때 그 반대의 경우보다 단열효과가 뛰어난 것으로 나타났다.

FCVA 방법으로 증착된 다이아몬드상 탄소 박막의 XPS 및 XRR 특성 연구 (A Study on XPS and XRR Characteristics of DLC films Deposited by FCVA Method)

  • 박창균;장석모;엄현석;서수형;박진석
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권3호
    • /
    • pp.109-115
    • /
    • 2003
  • Diamond-like carbon (DLC) films are deposited at room temperature using a filtered cathodic vacuum arc (FCVA) technique. The influence of negative bias voltage (applied to the substrate from 0 to -250V) on the $sp^3$ hybridized carbon fraction is examined by Raman spectroscopy and x-ray photoelectron spectroscopy (XPS) for C 1s core peak. For the first time, depth profile of C 1s, Si 2p, and O 1s XPS peaks for the deposited DLC film are obtained. DLC film is modeled as a multilayered structure. composing of surface, bulk, and interface. In addition, the x-ray reflectivity (XRR) is proposed as a method for estimating the density, surface roughness, and thickness of each layer constituting the DLC film. The estimated thickness of DLC film is in good agreement with the result obtained from the transmission electron microscope (TEM) measurement.

화학증착법에 의해 제조된 PbTiO$_3$ 박막의 AES와 XPS에 의한 조성분석 (The Chemical COmposition Analysis by AES and XPS of PbTiO$_3$ Thin Films Fabricated by CVD)

  • Soon Gil Yoon;Ho Gi Kim
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1989년도 춘계학술대회 논문집
    • /
    • pp.83-86
    • /
    • 1989
  • Lead titanate thin films with a perovskite structure were successfully structure were successfully fabricated on titanium substrate by Chemical Vapour Deposition(CVD). Analyses of Auger Electron Spectroscopy(AES) and X-ray Photoelectron Spectroscopy (XPS) have been performed in order to find a chemical composition of lead titanate films. The analysis of chemical composition by AES and XPS was investigated for variations of deposition temperature and Ti(C$_2$H$_{5}$O)$_4$ fractions. The chemical composition of PbTiO$_3$by XPS analysis was almost constant regardless of deposition parameters and the comparison of chemical composition by AES and XPS was performed.d.

  • PDF

$Cd_{1-x}Co_xIn_2Se_4$ 결정의 XPS 분석 (XPS Analysis of $Cd_{1-x}Co_xIn_2Se_4$ Crystals)

  • 최성휴
    • 한국진공학회지
    • /
    • 제3권3호
    • /
    • pp.355-359
    • /
    • 1994
  • Cd1-xCoxIn2Se4(X=0.50) 결정을 수직 Bridgman 방법으로 성장시키고 성장된 결정의 결정구조 및 XPS 특성을 연구하였다. 성장된 결정은 pseudocubic 구조이고 격자상수는 a=5.778$\AA$으로 주어졌다. Cd1-xCoxIn2Se4 결정의 각 성분원소인 cadmium cobalt indium 그리고 selenium에 대한 XPS spectrum으 로부터 결합에너지와 결합상태를 조사하였다. Cd1-xCoxIn2Se4결정과 결합하지 안는 각 성분원소인 cadium cobalt imdium 그리고 selenium에 대한 core level의 XPS spectrum과 비교하면 각 성분원소상 이의 결합에 의한 chemical shift 현상 때문에 core level의 결합에너지가 0.10~4.87 eV 차이가 있다. Cd1-xCoxIn2Se4 결정에서 Co 2P3/2 core level의 주 peak와 statellite peak와의 결합에너지 차이로부터 cadmium과 치화된 cobalt는 Co2+ ion으로 Td symmetry 점에 위치함을 알 수 있다.

  • PDF

BCl$_3$/SF6 gas chemistries에 의한 TiW막의 식각특성 연구 (A Study on the Etching Characateristics of TiW Films using BCl$_3$/SF6/ gas chemistries)

  • 권광호;김창일;윤선진;김상기;백규하;남기수
    • 전자공학회논문지D
    • /
    • 제34D권3호
    • /
    • pp.1-8
    • /
    • 1997
  • The surface properties after plasma etching of TiW alloy using the chemistries of BCl$_{3}$ and SF$_{6}$ gases with varying mixing ratio have been investigated using XPS(X-ray photoelectron spectrocopy). The elements existed on the etched sampled have been extracted with BCL$_{3}$/SF$_{6}$ ratio and their chemical binding states have also been analysed. It was confirmed that the thickness of native oxide formed on the TiW films is thinner than 10nm by using Ar sputtering. At the same time, the roughness of etched surface has been esamnied using AFM (atomic force microscopy). on the basis of the basis of this results, the relations between the caanges of oxygen contents detected by XPS and the rouhness of etched surface have been discussed. And the etch rate and etched profile of Tiw films have been examined and the changes of the etch rate and etched prfile have been discussed with XPS results. From XPS results, the role of passivation layer consisted of Ti-S compound with XPS results. From XPS results, the role of passivation layer consisted of Ti-S compound has been proposed. Ti-S compound seems to make a role of passivation layer that surpresses Ti-O formation.ion.

  • PDF

XPS 분석을 통한 CrMoN 코팅의 마찰마모 거동 연구 (Tribological Behavior Analysis of CrMoN Coating by XPS)

  • 양영환;여인웅;박상진;임대순;오윤석
    • 대한금속재료학회지
    • /
    • 제50권8호
    • /
    • pp.549-556
    • /
    • 2012
  • The tribological behavior of CrMoN films with respect to surface chemistry was investigated by using X-ray photoelectron spectroscopy (XPS). All of the films were prepared from a hybrid PVD system consisting of DC unbalanced magnetron (UBM) sputtering and arc ion plating (AIP) sources. The tribological property of the films was evaluated by a friction coefficient using a Ball-on-disk type tribometer. The chemistry of wear track was analyzed by energy dispersive spectroscopy (EDS) and XPS. The friction coefficient was measured to be 0.4 for the CrMoN film, which is lower than that of a monolithic CrN film. EDS and XPS results imply the formation of an oxide layer on the coating surface, which was identified as molybdenum oxide phases, known to be a solid lubricant during the wear test.

원격 플라즈마 화학기상증착법에 의해 중합된 아크릴산 필름의 XPS 분석 (XPS Analysis of Acrylic Acid Films Polymerized by Remote Plasma-Enhanced Chemical Vapor Deposition)

  • 김성훈;서문규
    • 공업화학
    • /
    • 제20권5호
    • /
    • pp.536-541
    • /
    • 2009
  • 플라즈마 중합 아크릴산 필름을 원격 플라즈마 방식으로 Si과 KBr 기판 위에 증착하였다. 플라즈마 출력, 반응 압력, 간접 플라즈마 방식이 필름의 성장속도, 화학적 구조 및 화학 결합 상태 등에 미치는 영향을 조사하였다. 화학 구조와 화학적 상태는 FT-IR, XPS 분석과 curve fitting 기법으로 분석하였다. 플라즈마 출력에 따른 필름의 성장속도는 100 W에서 포화값을 보이지만, 압력에 대해서는 300 mtorr에서 최대값을 나타내었다. 플라즈마 출력을 높이거나 압력을 낮추면 단위 입자들에게 가해지는 에너지 값(W/FM)이 증가하여 아크릴산 분자의 파괴가 촉진되었다. XPS curve fitting 분석 결과, W/FM값이 커질수록 카르복실 COO 결합은 감소하지만 에테르 C-O 결합과 카보닐 C=O 결합은 증가하여 서로 반대의 경향을 보임을 확인하였다.