• 제목/요약/키워드: X70~X100

검색결과 319건 처리시간 0.035초

흉부(胸部)의 X선촬영(線撮影) 및 촬영장치(撮影裝置) 현황(現況)에 관(關)한 조사(調査) (A Study on Radiographic Equipments and Situation for the Chest)

  • 고신관;안봉선
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제8권2호
    • /
    • pp.3-9
    • /
    • 1985
  • From the study on the chest radiologic equipments and situations of university hospitals, general hospitals, and radiologic clinics located in Seoul area and Choong-cheong province, the author got conclusions as follows : 1. The rectfication methods of the equipments were employing mainly single or three-phase full wave, and 78% of the examined were using single phase full wave. 2. The focal sizes in case of small focus were less than 1.0mm in chest-only use, and more than 1.0mm in 81% of combined use. The focal sizes in case of large focus were more than 1.6mm in 78% of the total. 3. Maximum ratings of x-ray tubes were 47% at 125 kVp maximum tube voltage and 41% at 150kVp. The maximum tube currentes higher than 500mA were shown in 72% of all the examined. And the maximum exposure time was the range of 5-8sec. 4. Grid was not used in the 66% of all the hospitals. Equipment for chest-only was employing 10:1 grid ratio and the 2.0-2.9mmAl of total filtration formed 38% of all the examined. 5. In the processing time of exposed film, 68% of all was 90sec, and only 20% of all the examined used optimum developing temperature according to this condition. 6. In the radiographic conditions, more than 50% used low tube voltages lower than 70 kVp and only 3% of all the equipments used high tube voltages higher than 100 kVp. The 46.9% of all the equipments 300mA, and 53% of all used shorter exposure time less than 1/20(0.05) sec. 7. In the monthly average number of radiographs, 44% of all was x-ray the radiographs.

  • PDF

전악 치근단 방사선사진 촬영시 촬영조건에 따른 흡수선량 변화에 대한 연구 (COMPARISON OF ABSORBED DOSES RESULTING FROM VARIOUS INTRAORAL PERIAPICAL RADIOGRAPHY)

  • 강미애;박태원
    • 치과방사선
    • /
    • 제25권2호
    • /
    • pp.297-308
    • /
    • 1995
  • This study was designed to measure the absorbed dose to organs of special interest from full mouth with intraoral film(l4 films) and to compare the five periapical techniques. Thermoluminescent crystals(TLD-100 chip) were located in brain, orbit, bone marrow of mandibular ramus, bone marrow of mandibular body, bone marrow of 4th cervical spine, parotid gland, submandibular gland and thyroid gland. X -ray machine was operated at 70kVp and round collimating film holding device(XCP) and rectangular collimating film holding device(Precision Instrument) were used. The distance from the X-ray focus to the open end of the collimator was 8 inch, 12 inch and 16 inch. The results were as follows : 1. The absorbed dose was the highest in bone marrow of mandibular body(5.656mGy) and the lowest in brain (0.050mGy). 2. Generally, the lowest absorbed dose was measured from 16 inch cylinder, rectangular collimating film holding device with paralleling technique. But, in bone marrow of mandibular body and the floor of mouth, the highest absorbed dose was measured from 12 inch cylinder, rectangular collimating film holding device with paralleling techniques. 3. Comparing of five intraoral radiographic techniques, it was appeared statistically significant reduction of the absorbed doses measured with rectangular collimating film holding device compared to XCP film holding device (P<0.05). 4. No statistically significant reduction in the absorbed dose was found as cylinder length was changed(P>0.05).

  • PDF

산화처리 탄소의 전기화학적 거동 및 이를 이용한 EDLC 특성 (Oxidation-treated of Oxidized Carbons and its Electrochemical Performances for Electric Double Layer Capacitor)

  • 양선혜;김익준;전민제;문성인;김현수;안계혁;이윤표;이영희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.481-481
    • /
    • 2007
  • This work describes the effect of the number of roll pressing and the composition of carbon black on the electric and mechanical properties of carbon-PTFE electrode, in which composition is MSP 20 : carbon black: PTFE = 95-x : x : 5 wt.%. It was found that the best electric and mechanical properties were obtained in sheet electrode roll-pressed for about 15 times and in sheet electrode, in which composition is MSP 20 : carbon black: PTFE = 80 : 15 : 5 wt.%. These behaviors could be explained by the network structure of PTFE fibrils and conducting paths linked with carbon blacks, respectively. On the other hand, cell capacitor using the sheet electrode with 15 wt.% of carbon black attached on aluminum current collector with the electric conductive adhesive, in composition is carbon black : CMC = 70 : 30 wt.%, has exhibited the best rate capability in the current range of $0.5mA/cm^2$ $100mA/cm^2$ and the lowest equivalent series resistance.

  • PDF

A novel barium oxide-based Iraqi sand glass to attenuate the low gamma-ray energies: Fabrication, mechanical, and radiation protection capacity evaluation

  • Al-Saeedi, F.H.F.;Sayyed, M.I.;Kapustin, F.L.;Al-Ghamdi, Hanan;Kolobkova, E.V.;Tashlykov, O.L.;Almuqrin, Aljawhara H.;Mahmoud, K.A.
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.3051-3058
    • /
    • 2022
  • In the present work, untreated Iraqi sand with grain sizes varied between 100 and 200 ㎛ was used to produce a colored glass sample that has shielding features against the low gamma-ray energy. Therefore, a weight of 70-60 wt % sand was mixed with 9-14 wt% B2O3, 8-10 wt% Na2O, 4-6 wt% of CaO, 3-6 wt% Al2O3, in addition to 0.3% of Co2O3. After melting and annealing the glass sample, the X-ray diffraction spectrometry was applied to affirm the amorphous phase of the fabricated glass samples. Moreover, the X-ray dispersive energy spectrometry was used to measure the chemical composition, and the MH-300A densimeter was applied to measure the fabricated sample's density. The Makishima-Makinzie model was applied to predict the mechanical properties of the fabricated glass. Besides, the Monte Carlo simulation was used to estimate the fabricated glass sample's radiation shielding capacity in the low-energy region between 22.1 and 160.6 keV. Therefore, the simulated linear attenuation coefficient changed between 10.725 and 0.484 cm-1, raising the gamma-ray energy between 22.1 and 160.6 keV. Also, other shielding parameters such as a half-value layer, pure lead equivalent thickness, and buildup factors were calculated.

Pharmacokinetics of oxytetracycline in hybrid catfish (Clarias macrocephalus x C. gariepinus) after intravascular and oral administrations

  • Amnart Poapolathep;Kednapat Sriphairoj;Sittichai Hatachote;Kannika Wongpanit;Duangkamol Saensawath;Narumol Klangkaew;Napasorn Phaochoosak;Mario Giorgi;Saranya Poapolathep
    • Journal of Veterinary Science
    • /
    • 제25권4호
    • /
    • pp.58.1-58.8
    • /
    • 2024
  • Importance: Over the past decade, catfish farming has increased in Southeast Asia. However, there has been no existing for pharmacokinetic data in the hybrid catfish (Clarias macrocephalus x C. gariepinus). Objective: This study was designed to evaluate the pharmacokinetic characteristics of oxytetracycline (OTC) in the hybrid catfish, following single intravascular (IV) or oral (PO) administration at a single dosage of 50 mg/kg body weight (BW). Methods: In total, 140 catfish (each about 100-120 g BW) were divided into two groups (n = 70). Blood samples (0.6-0.8 mL) were collected from ventral caudal vein at pre-assigned times up to 144 h (sparse samples design). OTC plasma concentrations were analyzed using high-performance liquid chromatography-photodiode array detector. Results: The pharmacokinetic parameter of OTC was evaluated using a non-compartment model. OTC plasma concentrations were detectable for up to 144 and 120 h after IV and PO, respectively. The elimination half-life value of OTC was long with slow clearance after IV administration in hybrid catfish. The average maximum concentration value of OTC was 2.72 ㎍/mL with a time at the maximum concentration of 8 h. The absolute PO bioavailability was low (2.47%). Conclusions and Relevance: These results showed that PO administration of OTC at a dosage of 50 mg/kg BW was unlikely to be effective for clinical use in catfish. The pharmacodynamic properties and clinical efficacy of OTC after multiple medicated feed are warranted.

카드뮴의 흡입독성 연구를 위해 설계된 에어로졸 발생장치에서 발생된 카드뮴 에어로졸의 입경분석(766ppm 카드뮴 네뷸라이징 용액) (Particle Size Analysis of Cadmium Aerosol for Cadmium Inhalation Toxicology Study (766ppm Cadmium Nebulizing Solution))

  • 정재열;도날드밀턴;김태형;이종영;장두섭;강성호;송용선;이기남
    • 동의생리병리학회지
    • /
    • 제16권5호
    • /
    • pp.1035-1041
    • /
    • 2002
  • Ultrasonic nebulizer with the application of new engineering methodology and the design of electronic circuit and 766ppm Cd nebulizing solution were used to generate cadmium aerosol for inhalation toxicology study. The results of particle size analysis for cadmium aerosol were as following. The highest particle counting for source temperature 20℃ was 43.449 x 10³ in inlet temperature 250℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 50℃ was 43.211 x 10³ in inlet temperature 100 ℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 70℃ was 41.917x10³ in inlet temperature 250℃ and particle diameter 0.75㎛. The ranges of geometric mean diameter(GMD) were 0.677-1.009㎛ in source temperature 20℃, 0.716-0.963㎛ in source temperature 50℃, and 0.724-0.957㎛ in source temperature 70℃. The smallest GMD was 0.677㎛ in source temperature 20℃ and inlet temperature 20℃. and the largest GMD was 1.009㎛ in source temperature 20℃ and inlet temperature 20℃. The ranges of geometric standard deviation(GSD) were 1.635-2.101 in source temperature 20℃. 1.676-2.073 in source temperature 50℃, and 1.687-2.051 in source temperature 70℃. The lowest GSD was 1.635 in source temperature 20℃ and inlet temperature 20℃, and the highest GSD was 2.101 in source temperature 20℃ and inlet temperature 200℃. Aerosol generated for cadmium inhalation toxicology study was polydisperse aerosol. The ranges of mass median diameter(MMD) were 1.399-5.270㎛ in source temperature 20℃. 1.593-4.742㎛ in source temperature 50℃, and 1.644-4.504㎛ in source temperature 70℃. The smallest MMD was 1.399㎛ in source temperature 20℃ and inlet temperature 20℃, and the largest MMD was 5.270㎛ in source temperature 20℃ and inlet temperature 200℃. Increasing trends for GMD, GSD, and MMD were observed with same source temperature and increase of inlet temperature. MMD for inhalation toxicology testing in EPA guidance is less than 4㎛. In our results. inlet temperature 20 and 50℃ in source temperature 20℃, and inlet temperature 20 to 150℃ in source temperature 50 and 70℃ were conformed to the EPA guidance. MMD for inhalation toxicology testing in OECD and EU is less than 3㎛. In our results, inlet temperature 20 and 50℃ in source temperature 20, 50, and 70℃ were conformed to the OECD and EU guidance.

플라즈마 용사방식에 의해 형성된 페라이트-탄화규소 표면층의 마이크로파 흡수 특성(II) (Microwave Absorbing Characteristics of Ferrite-silicon carbide surface Films Produced)

  • 신동찬;손현
    • 한국통신학회논문지
    • /
    • 제18권8호
    • /
    • pp.1169-1175
    • /
    • 1993
  • 레이다의 추적 및 탐색으로 부터 비행 물체를 보호하기 위한 목적으로, 알루미늄 합금표면에 페라이트-탄화규소 복합물인 마이크로파 흡수층을 플라즈마 용사방식으로 제작하였다. 본 논문에서는 페라이트-탄화규소층(I) 제조시 사용했던 탄화규소 입자의 평균크기인 34[rm]대신에15[rm]가 사용되었으며, 플라즈마 용사변수들 중에서 분말의 공급비율은 70[Kg/h]대신에 50[Kg/h] 그리고, 용사거리는 80[mm[ 대신에 100[mm]가 사용 되었다. X-band(8~12.4(GHz)레이다용 페라이트-탄화규소 전자파 흡수체를 실험적으로 설계하고 시험제작하여 전기적 특성을 평가한 결과, -lOdB의 반사량을 허용한도로 했을 때 약 2.8%의 대역폭이 얻어졌으며, 최대 흡수두께는 0.5(mm)로 매우 양호한 박층형 전자파 흡수체가 얻어졌다.

  • PDF

고에너지밀도 캐패시터를 위해 PET 기판에 증착한 TiO2 박막의 특성 (Properties of TiO2 Thin Films Deposited on PET Substrate for High Energy Density Capacitor)

  • 박상식
    • 한국재료학회지
    • /
    • 제22권8호
    • /
    • pp.409-415
    • /
    • 2012
  • $TiO_2$ thin films for high energy density capacitors were prepared by r.f. magnetron sputtering at room temperature. Flexible PET (Polyethylene terephtalate) substrate was used to maintain the structure of the commercial film capacitors. The effects of deposition pressure on the crystallization and electrical properties of $TiO_2$ films were investigated. The crystal structure of $TiO_2$ films deposited on PET substrate at room temperature was unrelated to deposition pressure and showed an amorphous structure unlike that of films on Si substrate. The grain size and surface roughness of films decreased with increasing deposition pressure due to the difference of mean free path. X-ray photoelectron spectroscopy (XPS) analysis revealed the formation of chemically stable $TiO_2$ films. The dielectric constant of $TiO_2$ films was significantly changed with deposition pressure. $TiO_2$ films deposited at low pressure showed high dissipation factor due to the surface microstructure. The dielectric constant and dissipation factor of films deposited at 70 mTorr were found to be 100~120 and 0.83 at 1 kHz, respectively. The temperature dependence of the capacitance of $TiO_2$ films showed the properties of class I ceramic capacitors. $TiO_2$ films deposited at 10~30 mTorr showed dielectric breakdown at applied voltage of 7 V. However, the films of 500~300 nm thickness deposited at 50 and 70 mTorr showed a leakage current of ${\sim}10^{-8}{\sim}10^{-9}$ A at 100 V.

흑색 화산회토인 남원통의 분류 (Taxonomical Classification of Namweon Series, Black Volcanic Ash Soils)

  • 송관철;현병근;손연규;임한철;이신찬
    • 한국토양비료학회지
    • /
    • 제42권5호
    • /
    • pp.385-392
    • /
    • 2009
  • 대표적인 흑색 화산회토인 남원통은 Ap, BA 및 Bw층에서 Oxalate 침출성 (Al + 1/2 Fe) 함량이 각각 5.2%, 7.4%, 9.8%로 높고 인산보유능이 각각 85.4%, 98.4% 98.3%로 매우 높다. 용적밀도가 각각 $0.72,\;0.62,\;0.76Mg\;m^{-3}$으로 매우 낮다. 전 토층이 Andic 토양 특성을 보유하고 있어서 Andisols로 분류 된다. Udic 토양수분상을 보유하고 있으며, 토양수분 장력 1,500 kPa에서의 토양수분함량이 전토층에서 15% 이상이므로 아목은 Udands로 분류된다. Ap층과 BA층에서는 Allophane과 Al-유기복합체가 혼재되어 있으나, Bw층에서는 활성 Al이 주로 Allophane의 구성분으로 존재하고 있으며, 전 토층을 통하여 Allophane과 Ferrihydrite 함량이 높다. 습윤시 명도와 채도 값이 Ap, BA 및 Bw층 모두에서 2 이하이고, 유기탄소 함량이 각각 $125,\;115,\;42g\;kg^{-1}$이며, melanic index가 각각 1.53, 1.50, 1.55이다. 0 에서 72 cm 깊이까지 모든 층위에서 melanic 감식표층의 분류조건을 충족시키고 있다. 따라서 대군은 Melanudands로 분류된다. Ap, BA 및 Bw층에서 토양수분장력 1,500 kPa일 때 토양수분함량이 풍건 시료의 경우 각각 28.9, 29.1, 27.6%로 15% 이상이며, 비풍건 시료의 경우 34.2, 55.3, 48.7%로 70% 이하이다. 0~72 cm의 깊이에서 유기탄소 함량이 $60g \;kg^{-1}$ 이상이며, 습윤시 명도와 채도 값이 2 이하이므로 아군은 Pachic Melanudands 로 분류된다. 토양수분 제어부위에서 토양수분장력 1,500 kPa일때 토양수분함량이 풍건 시료의 경우 12% 이상이며, 비풍건 시료의 경우 30~100% 범위 내에 있으므로 대체 토성속은 medial에 속한다. 8 x acid oxalate 침출 Si(%) + 2 x acid oxalate 침출 Fe(%) 값이 광물속 제어부위에서 12.3~19.5로 5 이상이다. 또한 2 x acid oxalate 침출 Fe 값이 8 x acid oxalate 침출 Si(%) 값보다 크므로 광물속은 ferrihydritic에 속한다. 남원통은 thermic 토양온도상을 보유하므로 ashy, thermic family of Typic Melanudands가 아니라 medial, ferrihydritic, thermic family of Pachic Melanudands로 분류되어야 한다.

Nutrient requirement for maintenance and nutritional changes of the Hanwoo steers in early-fattening stage under heat stress

  • Choi, Chang Weon
    • 농업과학연구
    • /
    • 제45권1호
    • /
    • pp.74-83
    • /
    • 2018
  • Four early-fattening Hanwoo steers weighing $247{\pm}13.5kg$ were used within a $4{\times}4$ Latin square design to establish a nutrient requirement for maintenance and to investigate nutritional changes in the steers under heat stress condition. The steers were fed four different energy level diets: 100% (control) and 100%, 115% and 130% of total digestible nutrients (TDN) requirement of the early-fattening Hanwoo steers for maintenance based on the Korean Feeding Standard for Hanwoo. The steers in the control were housed with no stress (temperature $24^{\circ}C$ and humidity 60%), whereas the steers in the other groups were under heat stress (temperature $30^{\circ}C$ and humidity 70%). True digestibilities of dry matter (DM) and other nutrients were not significantly (p > 0.05) affected by heat stress (i.e., control vs T100). This may be the result of a lower DM intake than that of the Korean feeding standard due to the establishment of the nutrients requirement under heat stress. Heat stress and different energy intake levels did not affect the blood metabolite concentrations. Average daily gain (ADG) for T100 (-69.6 g) was lower than that of the control (-44.6 g, numerically), T115 (44.6 g, p < 0.05) and T130 (83.3 g, p < 0.05), respectively. Based on the ADG and TDN intake, the equation (Y = 0.1814X + 111.5) for the TDN requirement of the early fattening Hanwoo steers for maintenance was calculated, indicating that 11.5% of TDN requirement for maintenance under heat stress may be additionally supplied.