• 제목/요약/키워드: X-ray topography

검색결과 58건 처리시간 0.028초

The effect of nano-Zinc oxide on the self-cleaning properties of cotton fabrics for textile application

  • Panutumrong, Praripatsaya;Metanawin, Tanapak;Metanawin, Siripan;O-Charoen, Narongchai
    • International Journal of Advanced Culture Technology
    • /
    • 제3권1호
    • /
    • pp.13-20
    • /
    • 2015
  • The self-cleaning properties of nano-zinc oxide on cotton fabrics have been investigated. The cotton fabric has been prepared by pad-dry method. The nano-zinc oxide was encapsulated in the polystyrene particle by mini-emulsion process prior used. The loading amount of zinc oxide particles into the mini-emulsion were various from 1% wt to 40%wt. The particles sizes of ZnO-encapsulated polystyrene mini-emulsion were determined using dynamic light scattering. It was showed that the particle size of the mini-emulsion was in the range of 124-205 nm. The topography and morphology of ZnO-encapsulated polystyrene which coated on cotton fabrics was observed using scanning electron microscopy. The crystal structure of ZnO-coated on cotton fabrics was explored by X-ray diffraction spectroscopy. The photocatalytic activities of zinc oxide were present through the self-cleaning properties. The presents of the zinc oxide on cotton fabrics significantly showed the improving of the self-cleaning properties under UV radiation.

ZnO 나노 입자 분산 레진의 thermal imprinting 공정을 통한 기능성 패턴 제작 (Fabrication of Functional ZnO Nano-particles Dispersion Resin Pattern Through Thermal Imprinting Process)

  • 권무현;이헌
    • 한국정밀공학회지
    • /
    • 제28권12호
    • /
    • pp.1419-1424
    • /
    • 2011
  • Nanoimprint lithography is a next generation lithography technology, which enables to fabricate nano to micron-scale patterns through simple and low cost process. Nanoimprint lithography has been applied in various industry fields such as light emitting diodes, solar cells and display. Functional patterns, including anti-reflection moth-eye pattern, photonic crystal pattern, fabricated by nanoimprint lithography are used to improve overall efficiency of devices in that fields. For these reasons, in this study, sub-micron-scaled functional patterns were directly fabricated on Si and glass substrates by thermal imprinting process using ZnO nano-particles dispersion resin. Through the thermal imprinting process, arrays of sub-micron-scaled pillar and hole patterns were successfully fabricated on the Si and glass substrates. And then, the topography, components and optical property of the imprinted ZnO nano-particles/resin patterns are characterized by Scanning Electron Microscope, Energy-dispersive X-ray spectroscopy and UV-vis spectrometer, respectively.

Evaluation of antibacterial activity and cytotoxic effects of green AgNPs against Breast Cancer Cells (MCF 7)

  • Vizhi, Dhandapani Kayal;Supraja, Nookala;Devipriya, Anbumani;Tollamadugu, Naga Venkata Krishna Vara Prasad;Babujanarthanam, Ranganathan
    • Advances in nano research
    • /
    • 제4권2호
    • /
    • pp.129-143
    • /
    • 2016
  • The present work reports a facile, rapid and an eco-friendly method for the synthesis of silver nanoparticles using Luffa acutangula (L. acutangula) leaves extract and their antibacterial and cytotoxic effects. The synthesized silver nanoparticles (AgNPs) were characterized by UV-Visible spectroscopy (UV-Vis), Fourier transform infrared spectroscopy (FT-IR) and X-ray diffraction analysis (XRD). Additionally the topography, morphology and the elemental composition of the particles were determined by Scanning Electron Microscopy (SEM) and Energy dispersive spectrophotometric (EDS) technique and the measured particle sizes from SEM micrographs are in the range of 12.5 to 24.5nm. The in-vitro antimicrobial activity of the synthesized nanoparticles was high against gram positive Staphylococcus aureus and moderate against gram negative Escherichia coli and Pseudomonas aeruginosa strains. Further, the cytotoxic effects of synthesized AgNPs were evaluated against Human Breast Cancer (MCF 7) cell line.

Exceptional removal capacity of clenbuterol from aqueous solution by mechano-synthesized [Cu (INA)2]-MOF via ball-mill

  • Marinah Mohd, Ariffin;Usman, Armaya'u;Saw Hong, Loh;Wan Mohd Afiq Wan Mohd, Khalik;Hanis Mohd, Yusoff
    • Membrane and Water Treatment
    • /
    • 제13권6호
    • /
    • pp.321-335
    • /
    • 2022
  • Copper-based Metal-organic framework (MOF) namely ([Cu (INA)2]-MOF) is synthesized by ball milling and characterized using scanning electron microscopy (SEM) for the topography, microstructure, and elemental evidence determination, powdered X-ray diffraction (XRD) for the crystallinity measurement, thermogravimetric (TG) analysis was performed to determine the thermal stability of the material, and Fourier transformed infrared (FTIR) spectroscopy for functional groups identification. The use of [Cu (INA)2]-MOF as hazardous removal material of β-agonists as persistent hazardous micro-pollutants in our environmental water is first reported in this study. The removal efficiency of the Cu-MOF is successfully determined to be 97.7% within 40 minutes, and the MOF has established an exceptional removal capacity of 835 mg L-1 with 95 % percent removal on Clenbuterol (CLB) even after the 5th consecutive cycle. The Langmuir model of the adsorption isotherms was shown to be more favourable, while the pseudo-second-order model was found to be favoured in the kinetics. The reaction was exothermic and spontaneous from a thermodynamic standpoint, and the higher temperatures were unfavourable for the adsorption study of the CLB. As a result, the studied MOF have shown promising properties as possible adsorbents for the removal of CLB in wastewater.

수종의 방법으로 임프란트 표면 처치후 표면의 형태 및 성분 변화 분석에 관한 연구 (The XPS and SEM Evaluation of Various Technique for Cleansing and Decontamination of The Rough Surface Titanium Implants)

  • 김선봉;임성빈;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제31권4호
    • /
    • pp.749-763
    • /
    • 2001
  • Osseointegrated titanium implants have become an integral therapy for the replacement of teeth lost. For dental implant materials, titanium, hydroxyapatite and alumina oxide have been used, which of them, titanium implants are in wide use today. Titanium is known for its high corrosion resistance and biocompatability, because of the high stability of oxide layer mainly consists of $TiO_2$. With the development of peri-implantitis, the implant surface is changed in surface topography and element composition. None of the treatments for cleaning and detoxification of implant surface is efficient to remove surface contamination from contaminated titanium implants to such extent that the original surface elemental composition. In this sights, the purpose of this study was to evaluate rough surface titanium implants by means of scanning electron microscopy(SEM) and X-ray photoelectron spectroscopy(XPS) with respect to surface appearance and surface elemental composition. Moreover, it was also the aim to get the base for treatments of peri-implantitis. For the SEM and XPS study, rough surface titanium models were fabricated for control group. Six experimental groups were evaluated: 1) long-time room exposure, 2 ) air-powder abrasive cleaning for 1min, 3) burnishing in citric acid(pH1) for 1min, 4) burnishing in citric acid for 3min, 5) burnishing in tetracycline for 1min, 6) burnishing in tetracycline for 3min. All experimental treatments were followed by 1min of rinsing with distilled water. The results were as follows: 1. SEM observations of all experimental groups showed that any changes in surface topography were not detected when compared with control group. (750 X magnification) 2. XPS analysis showed that in all experimental groups, titanium and oxygen were increased and carbon was decreased, when compared with control group. 3. XPS analysis showed that the level of titanium, oxygen and carbon in the experimental group 3(citric acid treatment for 1min, followed by 1min of distilled water irrigation) reached to the level of control group. 4. XPS analysis showed that significant differences were not detected between the experimental group 1 and the other experimental groups except of experimental group 3. The Ti. level of experimental group 2, airpowder abrasive treatment for lmin followed by 1min of saline irrigation, was lower than the Ti. level of tetracycline treated groups, experimental group 5 and 6. From the result of this study, it may be concluded that the 1min of citric acid treatment followed by same time of rinsing with distilled water gave the best results from elemental points of view, and can be used safely to treat peri-implantitis.

  • PDF

개오동이 흰쥐의 Collagen 유발 관절염에 미치는 영향 (Effects of Catalpa Ovata on the Collagen-induced Arthritis in Lewis Rats)

  • 김순중;서일복;윤제필
    • 대한추나의학회지
    • /
    • 제4권1호
    • /
    • pp.75-88
    • /
    • 2003
  • Objectives : The purpose of this study is to find out the effects of Catalpa Ovata on the collagen-induced arthritis in the lewis rats. and we infere the effects of Catalpa Ovata on the rheumatoid arthritis in the human body. Methods : We investigated the effect of Catalpa Ovata on the Collagen-induced arthritis in Lewis rats via morphology, histology and serology as an experimental group, a control group, and a normal group. We feed Catalpa Ovata. only to an experimental group. Results : According to this research, the abnormal finding In Moire topography was 53.7% (1,018 students), and students needed X-ray re-examination were 11.2% (213 students). Students diagnosed scoliosis by X-ray re-examination were 1.8%. According to statistical analysis, interval between vertical base line of pelvis and vertical base line of neck, gap between left distance and right distance to the vertical base line of pelvis and difference of contour lines have strong correlations with deformity degree of the body surface examined by Moire. Conclusions : 1. The weight of an experimental group were lower than control group with statistically significant at 15 days later. 2, The paw edema volume of an experimental group were lower than control group at 10 days, 15 days later. but couldn't be found meaning. 3. The size of the tarsal joint of an experimental group were lower than control group at 5 days, 10 days, 15 days later, but couldn't be found meaning. 4. The volume of tumor necrosis factor-a at an experimental group were lower than control group with statistically significant. 5. The volume of interleukin-$1{\beta}$ at an experimental group were lower than control group with statistically significant. 6. An experimental group and a control group were showed ankylosing osteoarthritis, but an experimental group compared with a control group, alleviated In the fibrous ankylosis, destruction of articular cartilage and destruction of subchondral bony tissue. According to the above results, it might be considered that Catalpa Ovata has the suppression of the advance of the Collagen-induced arthritis and that result were presumed to bo connected with suppression of volume of the tumor necrosis $factor-{\alpha}$ and $interleukin-1{\beta}$ in the blood.

  • PDF

Moire 영상을 이용한 근골격계 질환의 한의학적 진단에 관한 연구 (A Study on Oriental Medical Diagnosis of Musculoskeletal Disorders using Moire Image)

  • 이은경;유승현;이수경;강성호;한종민;정명수;천은주;송용선;이기남
    • 대한예방한의학회지
    • /
    • 제4권2호
    • /
    • pp.72-92
    • /
    • 2000
  • This research has conducted studies on an Oriental medicine-based method of diagnosing of occupational musculoskeletal system diseases. This researcher has searched through existing relevant medical literature. Also, this researcher has worked on a moire topography using moire topography. In this course, this researcher has reached the following conclusion in relation to the possibility of using a moire topography as a diagnosing device of musculoskeletal system diseases under Oriental medicine . 1 The Western medicine outlines its criteria of screening occupational musculoskeletal system diseases as follows A. The occupational musculoskeletal diseases must clearly include one or more of the subjective symptoms characterized by pain, hypoesthesia dysaesthesia, anaesthesia. etc . B, There should be clinically admitted objective observations and diagnosis outlining that the disease concerned shows symptoms such as tenderness, induration. and edema that can appear with occupational musculoskeletal system diseases. dyscinesia should be admitted with the disease concerned, or there should be observations and diagnosis outlining that abnormality exists in electric muscular or nervous diagnosis and examination . C. It should be admitted that prior to the occurrence of symptoms or observations and diagnosis on musculoskeletal system-related diseases, a patient has been engaged in works with conditions requiring improper work posture or work movement. That is, this is an approach whereby they see abnormality in the musculoskeletal system come from material and structural defect, and adjust and control abnormality in the musculoskeletal system and secreta . 2. The Oriental medicines sees that a patient develops the pain of occupational musculoskeletal diseases as he cannot properly activate the flow of his life force and blood thus not only causing formation of lumps in the body and blocking the flow of life force and blood in some parts of the body. Hence, The Oriental medicine focuses on resolving the cause of weakening the flow of life force and blood, instead of taking material approach of correcting structural abnormality Furthermore , Oriental medicine sees that when muscle tension builds up, this presses blood vessels and nerves passing by, triggering circulation dyscrasia and neurological reaction and thus leading to lesion. Thus, instead of taking skeletal or neurophysiological approach. it seeks to fundamentally resolve the cause of the flow of the life force and blood in muscles not being activated. As a result Oriental medicine attributes the main cause of musculoskeletal system diseases to muscle tension and its build-up that stem from an individual's long formed chronicle habit and work environment. This approach considers not only the social structure aspect including companies owners and work environment that the existing methods have looked at, but also individual workers' responsibility and their environmental factors. Hence, this is a step forward method. 3 The diagnosis of musculoskeletal diseases under Oriental medicine is characterized by the fact that an Oriental medicine doctor uses not only photos taken by himself, but also various detection devices to gather information and pass comprehensive judgment on it. Thus, it is the core of diagnosis under Oriental medicine to develop diagnosing devices matching the characteristics of information to be induced and to interpret information so induced from the views of Oriental medicine. Diagnosis using diagnosing devices values the whole state of a patient and formal abnormality alike, and the whole balance and muscular state of a patient serves as the basis of diagnosis. Hence, this method, instead of depending on the information gathered from devices under Western medicine, requires devices that provide information on the whole state of a patient in addition to the local abnormality information that X-ray. CT, etc., can offer. This method sees muscle as the central part of the abnormality in the musculoskeletal system and thus requires diagnosing devices enabling the muscular state. 4. The diagnosing device using moire topography under Oriental medicine has advantages below and can be used for diagnosing musculoskeletal system diseases with industrial workers . First, the device can Provide information on the body in an unbalanced state. and thus identify the imbalance and difference of height in the left and right stature that a patient can not notice at normal times. Second, the device shows the twisting of muscles or induration regions in a contour map. This is not possible with existing shooting machines such as X-ray, CT, etc., thus differentiating itself from existing machines. Third, this device makes it possible for Oriental medicine to take its unique approach to the abnormality in the musculoskeletal system. Oriental medicine sees the state and imbalance state in muscles as major factors in determining the lesion of musculoskeletal system, and the device makes it possible to shoot the state of muscles in detail. In this respect, the device is significant. Fourth, the device has an advantage as non-aggression diagnosing device.

  • PDF

모아레를 이용한 체형분석의 반복성 재현성에 관한 연구 (Study on the Repeatability and Reproductivity of a Moire Body Shape Analyser)

  • 이동엽;박영배;오환섭
    • 대한한의진단학회지
    • /
    • 제10권2호
    • /
    • pp.121-131
    • /
    • 2006
  • Background : As each human has a look in the face of oneself, he or she has a look of him or herself in the shape of the body also. And for the shape of the body which gives a big clue in diagnosis in musculoskeletal disorders. Therefor many means are used and developed for diagnosis through body shape or posture analysis for musculoskeletal disorders. X-ray, CT, MRI has been used for diagnosis through image in this way to tell about the inside of the human body. On the other side, moire topography was used for information about the exterior of the human body, but yet only minimal information such as the number of contour lines in each side was available. Therefor there were a few studies to use moire topography or other methods to get information about the surface of the human body in numeric values. The instrument used in this study which is a laser projection moire, is another trial to get numeric data about the surface of the human body. The instrument is composed of laser projector and a computer software to recompose and analyse the image data into depth, height, angle and length. Objectives : The study was focused on whether the instrument is reliable for clinic use, and to seek the proper environment and posture for the examination, and among the data the software provides, which items are more reliable and useful. Methods : For reproductivity and repeatability, 4 testers tested 2 persons. And to how if the body shape changes according to the posture and which posture gives the most reliable data, the test was performed in 6 different positions. Results : Result, the instrument showed sufficient repeatability and reproductivity for clinical use. And among the items the software provides, the length of the back, the angle of the back in the sagittal and coronal plane showed reliable results. And there was difference in the results according to the posture, and Therefor, in following studies using this instrument or similar type of posture analysing instruments, the length of the back, the angle of the back in the sagittal and coronal plane could be reliable item to use.

  • PDF

The role of EL2 in the infrared transmission images of defects in semi-insulating GaAs

  • Kang, Seong-Jun;Lee, Sung-Seok
    • Journal of information and communication convergence engineering
    • /
    • 제9권6호
    • /
    • pp.725-728
    • /
    • 2011
  • Infrared transmission images from GaAs semi insulating wafers were considered for years as directly related to the quantum absorption by electrons on fundamental states of deep centers, especially EL2. The satisfying correspondence of these images with the dislocations revealed by etching or X ray topography or infrared tomography led to the opinion that a strong concentration of EL2 centers was to be expected in the immediate vicinity of the dislocations. More recent work indicates that contrary to the expected behavior the photoqu$\acute{e}$nching of transmission images at T=80K does not appreciably change the image structure itself but more largely the uniform background level of absorption. Such investigations show that the transmission images of isolated dislocations (Indium doped materials) or cell structures of tangled dislocations (undoped materials) can be partly attributed to scattered light; similar operation at T=10K removes the dark features associated to EL2 but still preserves the skeleton of the pattern which is due to scattering. A result of the measurements is that dislocations must not be considered any longer as inexhaustive EL2 reservoirs. The lifetime of the photoqu$\acute{e}$nching mechanism is shown to vary differently for EL2 centers located close to the dislocations or in the matrix. In this paper we will develop the details of infrared image photoqu$\acute{e}$nching experiments in the vicinity of dislocations; undoped and In doped GaAs materials will be shown. These results will be discussed in the light of surface etching experiments.

부산일원(釜山一圓) 연안해빈사(沿岸海賓砂)의 퇴적학적(堆積學的) 연구(硏究) (Sedimentological Study of Littoral Beach Sand in Busan Area, South Korea)

  • 이유대;최광선
    • 자원환경지질
    • /
    • 제16권2호
    • /
    • pp.65-78
    • /
    • 1983
  • This report deals with the sedimentological study of the littoral sand of beaches in the Busan area. The purpose of this report is to know the grain size, mineralogical composition, heavy mineral and clay mineral of the beach sands, and gravity measurements of the Nagdong River Deltas. 1) As a whole, the littoral sand of the beaches are composed of uniformly medium grained, moderately sorted and nearly symmetrical. The barrier sand of the Nagdong Estuary is composed of fine grained, well sorted and nearly symmetrical. 2) The littoral sand of the beaches is transported by saltation and rolling. The barrier sand of the Nagdong Estuary is transported by suspension and saltation. 3) In the littoral sand of the beaches, the ratio of feldspar to quartz is 1 :2.31 and in the barrier sand of the Nagdong Estuary 1:1.40. 4) The content of heavy mineral of samples ranges from 0.54 to 3.87 %. The principal heavy minerals are hornblende, pyroxene, epidote, garnet, leucoxene, zircon, apatite, magnetite, hematite and ilmenite with minor accessories of rutile and olivine. 5) The x-ray diffraction analysis of the clay mineral informs the existence of quartz, feldspar, kaolinite and montmorillonite. The montmorillonite is considered to have been derived from the alteration of acidic volcanic rocks. 6) To determine the depositional structure of the Nagdong Estuary, Gravity measurements were made. Free air anomaly ranges from 14.5 mgal to 33.5 mgal and Bouguer anomaly ranges from 14.3 to 23.5 mgal and both are closely related to the topography. According to the interpreted layer structure, the upper layer composing sand, silt and clay, the intermediate layer composing sand with gravel, the lower layer composing weathered and soft rock, and bed rock composing hornfels or andesite. 7) The depositional environments of the study, the littoral area is dominated by the marine environment and the Nagdong Estuary by the mixed environment.

  • PDF