• Title/Summary/Keyword: X-ray spectrum

Search Result 596, Processing Time 0.032 seconds

Analysis of Beam Hardening of Modulation Layers for Dual Energy Cone-beam CT (에너지 변조 필터로 구현한 이중 에너지 콘빔 CT의 에너지 스펙트럼 평가 연구)

  • Ahn, Sohyun;Cho, Sam Ju;Keum, Ki Chang;Choi, Sang Gyu;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.27 no.1
    • /
    • pp.8-13
    • /
    • 2016
  • Dual energy cone-beam CT can distinguish two materials with different atomic compositions. The principle of dual energy cone-beam CT based on modulation layer is that higher energy spectrum can be acquired at blocked x-ray window. To evaluate the possibility of modulation layer based dual energy cone-beam CT, we analyzed x-ray spectrum for various thicknesses of modulation layers by Monte Carlo simulation. To compare with the results of simulation, the experiment was performed on prototype cone-beam CT for 50~100 kVp with CdTe XR-100T detector. As the result of comparing, the mean energy of energy spectrum for 80 kVp are well matched with that of simulation. The mean energy of energy spectrum for 80 and 120 kVp were increased as 1.67 and 1.52 times by 2.0 mm modulation layer, respectively. We realized that the virtual dual energy x-ray source can be generated by modulation layer.

The Defect Characterization of $Gd_2O_2S$: Tb Crystals by Positron Annihilation Spectroscopy (양전자 소멸 분광법을 이용한 $Gd_2O_2S$ : Tb 결함 특성)

  • 이종용;김창규
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.2
    • /
    • pp.92-98
    • /
    • 2004
  • DBPAS has been used to characterize atomic size defect structures in materials. In this investigation the numerical analysis of the Doppler spectra was employed to the determination of the shape parameter, S, defined as the ratio between the amount of counts in a central portion of the spectrum and the total counts of whole spectrum. As the samples were exposed by X-ray increasing the exposed doses from 3, 6, and 9 Gy with 6 MV and 15 MV, respectively and also irradiated by X-ray as the medical applications used for in 0, 2, 4 and 6 years. The S-parameter values were increased as increasing the exposed time and the energies, that indicated the defects generate more. The S-parameters of the samples with medical treatment is varied from 0.4932 to 0.4956.

X-ray Photoemission Spectroscopy Study of Cation-Deficient La$_{0.970}$Mn$_{0.970}$O$_3$ System (양이온 결손 La$_{0.970}$Mn$_{0.970}$O$_3$의 X-ray Photoemission Spectroscopy 관측)

  • 정우환
    • Journal of the Korean Ceramic Society
    • /
    • v.36 no.1
    • /
    • pp.50-54
    • /
    • 1999
  • We have measured the x-ray photoemission spectroscopy of cation deficient La0.970Mn0.970O3 as a function of temperature. Detailed results on the chemical shifts and changes in Mn 2p and Lp 3d core levels due to variation of temperature have been obtained. The Mn 2p 3/2 and 1/2 main peaks and La 3d core spectrum shift to lower binding energy levels with increasing temperature. This XPS behavior is correlated with the strength of localization of Mn3+. The Jahn-Teller effect due to Mn3+ besides the conventional random potential effects is likely to localize charge carriers in La-.970Mn0.970O3.

  • PDF

Synthesis, Structures and Properties of Two Metal-organic Frameworks Derived from 3-Nitro-1,2-benzenedicarboxylic Acid

  • Xu, Wen-Jia;Zhang, Ling-Yu;Tang, Jin-Niu;Wang, Dai-Yin;Pan, Gang-Hong;Feng, Yu
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.8
    • /
    • pp.2375-2380
    • /
    • 2013
  • Two metal-organic frameworks based on the connectivity co-effect between rigid benzenedicarboxylic acid and bridging ligand have been synthesized $[Zn_2(3-NO_2-bdc)_2(4,4'-bpy)_2H_2O]_n$ (1), $[Co(3-NO_2-bdc)(4,4'-bpy)H_2O]_n$ (2) (where $3-NO_2-bdcH_2$ = 3-nitro-1,2-benzenedicarboxylic acid, 4,4'-bpy = 4,4'-bipyridine). The two novel complexes were characterized by IR spectrum, elemental analysis, fluorescent properties, thermogravimetric analysis, single-crystal X-ray diffraction and powder X-ray diffraction (PXRD). X-ray structure analysis reveals that 1 and 2 are two-dimensional (2D) network structures. Complex 1 and complex 2 belong to triclinic crystal with P-1 space group. The luminescence measurements reveal that two complexes exhibit good fluorescent emissions in the solid state at room temperature. Also, thermal decomposition process and powder X-ray diffraction of complexes were investigated.

Multi-layer design of Hybrid method for digital X-ray imaging (디지털 X-ray imaging을 위한 Hybrid 방식의 다층구조 설계)

  • Cho, Sung-Ho;Park, Ji-Koon;Lee, Dong-Gil;Kim, Dae-Hwan;Kim, Jae-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.75-78
    • /
    • 2003
  • In recent years, there has been keen interest in developing flat panel detectors for all modalities of radiology, including gerneral radiology, fluoroscopy, electronic portal imaging, and mammography. In this paper, we report the new hybrid x-ray detector consisted of ZnS(Ag) photoemission layer and a-Se photoconductor layer to resolve problem of conventional x-ray detector such as the direct detector and the indirect detector. To design the structure of ZnS(Ag)/a-Se detector, the penetrated energy spectrum and absorption fraction was estimated using MCNP 4C code. Also, we carried out the experiment to demonstrate the result of MCNP 4C code. Experimental results showed that the absorption fraction of $500{\mu}m$-ZnS(Ag) film was above 87%, 75% at 60 and 80 kVp. As a results, we can determined the thickness of suitable phosphor and the thickness of photoconductor.

  • PDF

A Study on the Material Decomposition of Dual-Energy Iodine Image by Using the Multilayer X-ray Detector (다층구조 엑스선 검출기를 이용한 이중에너지 조영제 영상의 물질 구분에 관한 연구)

  • Kim, Jun-Woo
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.465-471
    • /
    • 2021
  • Dual-energy X-ray imaging (DEI) techniques can provide X-ray images that a certain material is suppressed or emphasized by combining two X-ray images obtained from two different x-ray spectrum. In this paper, a single-shot DEI, which uses stacked two detectors (i.e., multilayer detector), is proposed to reduce the patient dose and increase throughput in angiography. The polymethyl methacrylate (PMMA) and aluminum (Al) were selected as two basis materials for material decomposition, and material-specific images are reconstructed as a vector combination of these two materials. We investigate the contrast and noise performance of material-decomposed images using iodine phantoms with various concentrations and diameters. The single-shot DEI shows comparable performances to the conventional dual-shot DEI. In particular, the single-shot DEI shows edge enhancement in material-decomposed images due to the different spatial-resolution characteristics of upper and lower detectors. This study could be useful for designing the multilayer detector including scintillators and energy-separation filter for angiography purposes.

Performance analysis of improved hybrid median filter applied to X-ray computed tomography images obtained with high-resolution photon-counting CZT detector: A pilot study

  • Lee, Youngjin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3380-3389
    • /
    • 2022
  • We evaluated the performance of an improved hybrid median filter (IHMF) applied to X-ray computed tomography (CT) images obtained using a high-resolution photon-counting cadmium zinc telluride (CZT) detector. To study how the proposed approach improves the image quality, we measured the noise levels and the overall CT-image quality. We established a CZT imaging system with a detector length of 5.12 cm and thickness of 0.3 cm and acquired phantom images. To evaluate the efficacy of the proposed filter, we first modeled two conventional median filters. Subsequently, we were able to achieve a normalized noise power spectrum result of ~10-8 mm2, and furthermore, the proposed method improved the contrast-to-noise ratio by a factor of ~1.51 and the coefficient of variation by 1.55 relative to the counterpart values of the no-filter image. In addition, the IHMF exhibited the best performance among the three filters considered as regards the peak signal-to-noise ratio and no-reference-based image-quality evaluation parameters. Thus, our results demonstrate that the IHMF approach provides a superior image performance over conventional median filtering methods when applied to actual CZT X-ray CT images.

Block-matching and 3D filtering algorithm in X-ray image with photon counting detector using the improved K-edge subtraction method

  • Kyuseok Kim;Youngjin Lee
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2057-2062
    • /
    • 2024
  • Among photon counting detector (PCD)-based technologies, the K-edge subtraction (KES) method has a very high material decomposition efficiency. Yet, since the increase in noise in the X-ray image to which the KES method is applied is inevitable, research on image quality improvement is essential. Here, we modeled a block-matching and 3D filtering (BM3D) algorithm and applied it to PCD-based X-ray images with the improved KES (IKES) method. For PCD modeling, Monte Carlo simulation was used, and a phantom composed of iodine substances with different concentrations was designed. The IKES method was modeled by adding a log term to KES, and the X-ray image used for subtraction was obtained by applying the 3.0 keV range based on the K-edge region of iodine. As a result, the IKES image using the BM3D algorithm showed the lowest normalized noise power spectrum value. In addition, we confirmed that the contrast-to-noise ratio and no-reference-based evaluation results when the BM3D algorithm was applied to the IKES image were improved by 29.36 % and 20.56 %, respectively, compared to the noisy image. In conclusion, we demonstrated that the IKES imaging technique using a PCD-based detector and the BM3D algorithm fusion technique were very efficient for X-ray imaging.

Physico-Chemical Properties of Various Oxide Nanoparticles Synthesized with Electron Beam Irradiation System

  • Sin, Won-Gyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.437-437
    • /
    • 2014
  • Various oxide particles are synthesized in an ambient condition using an electron beam irradiation system. The formation of oxide particles is confirmed by FT-IR spectra results and the X-ray photoelectron spectrum. It is also shown that the morphology and size of oxide particles are significantly influenced by the type and flowrate of dilution gas. The energy dispersive X-ray (EDX) analysis also confirms that various oxide particles are synthesized.

  • PDF

Progress Report on Optical Spectroscopy of X-ray selected Intermediate-mass Black Holes

  • Kim, Minjin;Ho, Luis C.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.42.2-42.2
    • /
    • 2014
  • We present high-resolution optical spectra of newly selected candidates of intermediate-mass black holes. The sample was selected based on the variability and spectral shape in X-ray. The spectra was taken with Magellan 6.5 m Clay Telescope and cover the rest-frame region 3500-10000A. The high spectral resolution (R~4000) of the spectrum allows us to estimate BH masses of the sources. Interestingly, the majority of the sample appears to have broad emission lines. Using this dataset, we will estimate the BH masses and Eddington ratio in order to understand their physical properties.

  • PDF