• 제목/요약/키워드: X-ray scatter

검색결과 69건 처리시간 0.029초

영상의학과 이동검사 영역의 공간선량 분포에 대한 측정 및 분석 (The Measurement and Analysis by Free Space Scatter Dose Distribution of Diagnostic Radiology Mobile Examination Area)

  • 김성규;손상혁
    • 대한디지털의료영상학회논문지
    • /
    • 제11권1호
    • /
    • pp.5-13
    • /
    • 2009
  • There are several reasons to take X-ray in case of inpatients. Some of them who cannot ambulate or have any risk if move are taken portable X-ray at their wards. Usually, in this case, many other people-patients unneeded X-ray test, family, hospital workers etc-are indirectly exposed to X-ray by scatter ray. For that reason I try to be aware of free space scatter dose accurately and make the point at issue of portable X-ray better in this study. kVp dose meter is used for efficiency management of portable X-ray equipment. Mobile X-ray equipment, ionization chamber, electrometer, solid water phantom are used for measuring of free space scatter dose. First of all the same surroundings condition is made as taken real portable X-ray, inquired amount of X-ray both chest AP and abdomen AP most frequently examined and measured scatter ray distribution of two tests individually changing distance. In the result of measuring horizontal distribution with condition of chest AP it is found that the mAs is decreased as law of distance reverse square but no showed mAs change according to direction. Vertical distribution showed the mAs slightly higher than horizontal distribution but it isnt found out statistical characteristic. In abdomen AP, compare with chest AP, free space scatter dose is as higher as five-hundred times and horizontal, vertical distribution are quite similar to chest AP in result. In portable X-ray test, in order to reduce the secondary exposure by free space scatter dose first, cut down unnecessary portable order the second, set up the specific area at individual ward for the test the third, when moving to a ward for the X-ray test prepare a portable shielding screen. The last, expose about 2m apart from patients if unable to do above three ways.

  • PDF

흉부 X선 촬영 시 산란선 분포 연구 (Distribution of the Scatter Ray on Chest X-ray Examinations)

  • 조평곤
    • 한국콘텐츠학회논문지
    • /
    • 제12권7호
    • /
    • pp.255-260
    • /
    • 2012
  • 흉부 X-선 촬영 시 피사체의 유무, 촬영실내 X선관과 수광계 (image receptor), 환자 보기창 앞, 환자대기실 출입문 외측, 출입문 개폐여부, 방사선 관계 종사자 출입문 외측, 방사선 관계 종사자 출입문 개폐여부 등으로 구분하여 공간산란선발생을 알아보기 위한 연구로 공간산란선발생에 대한 연구 결과 피사체가 있을 때 수광계 (image receptor) 위치; Chest PA: $663{\pm}3.4$ mR/h, Chest Lateral: $2,067{\pm}3.7$ mR/h, X선관 위치; Chest PA: $293{\pm}2.1$ mR/h, Chest Lateral: $927{\pm}1.9$ mR/h, 환자대기실 출입문 외측 열고; Chest PA: $17{\pm}1.6$ mR/h, Chest Lateral: $88{\pm}2.6$ mR/h, 방사선 관계 종사자 촐입문 외측 열고; Chest PA: $3{\pm}1.6$ mR/h, Chest Lateral: $19{\pm}1.6$ mR/h), 피사체의 두께가 두꺼울수록 각 각의 측정지점에서 산란선 발생이 많았고, 출입문을 닫고 측정한 경우 산란선이 더 적었다. 그러므로 방사선 관계종사자는 촬영실내 산란선 분포에 대한 정확한 정보를 인지하여 불필요한 방사선 피폭을 줄일 수 있도록 노력해야 한다.

X선촬영실 내에서의 공간산란선량 변동에 관한 연구 (A Study on the Behavior of the Free Space Scatter dose in X-ray Diagnostic Room)

  • 오현주;김성수;김영일;임한영;김흥태;이후민;김학성;이상석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제17권2호
    • /
    • pp.21-27
    • /
    • 1994
  • In this pauper, when the X-ray exposure condition is 70, 90, 110 kV, 10 mAs, FFD 180 cm, FSO $10{\times}10$, $35{\times}35\;cm$, toward the $36{\times}36{\times}15\;cm$ acryl phantom, the free space scatter dose rate at the 15th points in X-ray diagnostic room was measured by electrometer and 1800 co ionization chamber. Therefore, the free space scatter dose distribution profile was drown, and then, the free space scatter dose contribution percentage was Investigated. The obtained results are summarized as following. 1. The X-ray tube leakage dose rate of the experiment generator at the 1 m from focus was measured maximum 85 mR/hr, minimum 20 mR/hr, therefore, this values was appeared below the KS rules, 2. The free space scatter dose become to larger at the primary X-ray beam around area, and lower at the back ward X-ray tube. The maximum values were 3,812 mR/hr at the front Lt 1 m $45^{\circ}$ point, minimum 117 mR/hr at the back ward 1 m $180^{\circ}C$ point. 3. As the more tube voltage and field size increase, the more free space scatter dose contribution percentage become to increase, as to 90 kV from 70 kV, increase to 12 %, to 110 kV from 90 kV, increase to 18 %, and then, become to 11 % at the $10{\times}10\;cm$ and 87 % at the $35{\times}35\;cm$. 4. The 89 % of the total producted scatter ray occured from acryl phantom, at the X-ray tube housing 6 %, at the front side back wall 5 %. 5. The free space scatter dose contribution percentage at the one point build up 80 % from the phanton direction, 14 % from the X-ray tube and collimator direction, 2.2 % from the front wall, 1.8 % from the side wall, 1.7 % the back wall.

  • PDF

X선 촬영시 산란선 방향 의존성에 관한 연구 (A Study on the Directional Dependence of Scatter Ray in Radiography)

  • 오현주;김성수;김영일;임한영;김흥태;이후민;김학성;이상석
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제18권1호
    • /
    • pp.63-70
    • /
    • 1995
  • In this pauper, the back, forward, side and $45^{\circ}$ oblique scatter dose were measured the X-ray exposure conditions 60, 80, 100, 120kV, FFD 100cm, FS $20\times20cm$, toward the $25\times25cm\times10\sim20cm$ of solid water, paraffin and MiX-DP phantom, and Pb, Cu, Al, and styrofoam meterials, by the electrometer and 5.3 cc ionization chamber. The obtained results are summarized as following. 1. The percentage depth dose(PDD) at the range of the diagnostic x-ray energy were appeared 50 % depth dose at the 2 cm depth with 60 kV, and 5 cm depth with 120 kV X-ray, 10 % depth dose at the 10 cm depth with 60 kV and 14 cm depth with 120 kV X-ray, 5 % below depth dose at the 20 cm depth. 2. The back scatter dose which were generated the surface of Pb, Cu and Al metal plates were 10 % below, and than the back scatter dose at the Pb plate were a most amount of these which were about 10 %, and were appeared the order of Cu and Al. 3. The percentage forward scatter were appeared from 50 % to 65 %, and the more phantom thicknees become, the more forward scatter were increased with the ratio of 5 % per 5 cm thickness. 4. The percentage back scatter which were generated the tissue equivalence meterials solid water, paraffin and MiX-DP were from 20 % to 40 %, and than the back scatter dose at the solid water were a mest amount of those, and paraffin and MiX-DP were appeared with the next values. 5. The percentage $90^{\circ}$ lateral and $45^{\circ}$ oblique side scatter dose were measured from 4 % to 12 %. a most amount of scatter dose which were generated from the patient in radiography were the forward scatter, the next values were the back scatter, the third values were the $90^{\circ}$ lateral scatter.

  • PDF

Contribution of Scattered X Rays to Signal Imaging with Anti-scatter Grids

  • Maeda, Koji;Arimura, Hidetaka;Morikawa, Kaoru;Kanamori, Hitoshi;Matsumoto, Masao
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.404-406
    • /
    • 2002
  • We have investigated the contribution of the scattered x rays to the signal imaging in the radiographs acquired with anti-scatter grids of several grid ratios by separating the line spread functions (LSFs) derived from the signal edge image into the primary and the scatter components. By using a 1.0-mm lead plate in the scattering material, the blurred signal edge images were acquired by use of an imaging plate at a tube voltage of 80 kV with the anti-scatter grids of grid ratios for 5:1, 6:1, 8:1, 10:1 and 12:1. The edge profiles of the signal images were scanned and those in relative exposure were differentiated to obtain the LSFs. To investigate the contribution of the scattered x rays to the signal imaging, we proposed a method for separating the LSFs derived from the signal images into the primary and the scatter components, where the scatter component was approximated with exponential function. Our basic approach is to separate the area of the LSFs by ratios of the scattered x-ray exposure to the primary x-ray exposure, which were obtained for the grid ratios by use of a lead disk method. The LSFs and the two components were Fourier transformed to obtain the modulation transfer functions (MTFs) and their two components. As the result, we found that, by using the anti-scatter grids, the scattered x rays were reduced, but the shape of the LSFs of the scatter component hardly changed. The contributions of the scatter component to the MTFs were not negligible (more than 10 %) for spatial frequencies lower than about 1.0 mm$\^$-l/ and that was greater as the grid ratio decreasing. On the other hand, for higher frequencies, the primary component was dominant compared with the scatter component.

  • PDF

The Effect of Grid Ratio and Material of Anti-scatter Grid on the Scatter-to-primary Ratio and the Signal-to-noise Ratio Improvement Factor in Container Scanner X-ray Imaging

  • Lee, Jeonghee;Lim, Chang Hwy;Park, Jong-Won;Kim, Ik-Hyun;Moon, Myung Kook;Lim, Yong-Kon
    • Journal of Radiation Protection and Research
    • /
    • 제42권4호
    • /
    • pp.197-204
    • /
    • 2017
  • Background: X-ray imaging detectors for the nondestructive cargo container inspection using MeV-energy X-rays should accurately portray the internal structure of the irradiated container. Internal and external factors can cause noise, affecting image quality, and scattered radiation is the greatest source of noise. To obtain a high-performance transmission image, the influence of scattered radiation must be minimized, and this can be accomplished through several methods. The scatter rejection method using an anti-scatter grid is the preferred method to reduce the impact of scattered radiation. In this paper, we present an evaluation the characteristics of the signal and noise according to physical and material changes in the anti-scatter grid of the imaging detector used in cargo container scanners. Materials and Methods: We evaluated the characteristics of the signal and noise according to changes in the grid ratio and the material of the anti-scatter grid in an X-ray image detector using MCNP6. The grid was composed of iron, lead, or tungsten, and the grid ratio was set to 2.5, 12.5, 25, or 37.5. X-ray spectrum sources for simulation were generated by 6- and 9-MeV electron impacts on the tungsten target using MCNP6. The object in the simulation was designed using metallic material of various thicknesses inside the steel container. Using the results of the computational simulation, we calculated the change in the scatter-to-primary ratio and the signal-to-noise ratio improvement factor according to the grid ratio and the grid material, respectively. Results and Discussion: Changing the grid ratios of the anti-scatter grid and the grid material decreased the scatter linearly, affecting the signal-to-noise ratio. Conclusion: The grid ratio and material of the anti-scatter grid affected the response characteristics of a container scanner using high-energy X-rays, but to a minimal extent; thus, it may not be practically effective to incorporate anti-scatter grids into container scanners.

산란 방사선이 치과용 방사선 필름에 미치는 영향에 관한 연구 (A STUDY ON THE SCATTER RADIATION AFFECTING THE DENTAL X-RAY FILM)

  • 박응천;김재덕
    • 치과방사선
    • /
    • 제22권1호
    • /
    • pp.87-94
    • /
    • 1992
  • The purpose of this study was to evaluate the effect of scatter radiation to dental x-ray film with long time-exposure in the different structures of the tooth, by using pinhole camera. For this study, pinhole camera, skull with tooth, and pocket dosimeter were used. The radiation with 70 and 90kVp and exposure time (minimum: 2.5 min., maximum 10 hrs.) was projected to the film in the pinhole camera. And density of the obtained x-ray film was measured with densitometer. In the intra-oral film taking, the amount of exposure of the scatter radiation affecting the thyroid gland area was measured with the dosimeter at the thyroid gland. The density of radiographs was compared in radiation projected with or without the metal cone of dental machine. The effect of the back scatter radiation to the film was also evaluated when the lead foil was removed. The obtained results were as follows: 1. A pinhole camera was a valuable device for locating the source of x-ray. 2. The scatter radiation affected the dental x-ray film when the radiation source was exposed. more than 5 hours'. In that case, the density of the scatter radiation could be observed visually. 3. The scatter radiation caused by short exposure of dental radiation didn't affect the diagnostic quality of the dental x-ray film. 4. The differences of densities between the tooth and the soft tissue according to exposure time showed 0.16 in 5 hours' exposure & 0.17 in 10 hours' exposure at 70 kVp & 0.12 in 5 hours' exposure & 0.13 in 10 hours' exposure at the 90kVp. 5. The differences of densities between the tooth and the soft tissue according to kVp showed no difference between 5 hours' exposure of tooth at 70 kVp and soft tissue at 90 kVp, but showed 0.05 high density in tooth when 10 hours' exposure at 90 kVp. 6. No difference of density was on radiographs taken with or without dental machine cone. 7. Back scatter radiation was recorded image of radiographs for only 3 min. 8. The amounts of the scatter radiation exposed to the thyroid gland in intraoral film taking were 1.12 mr in upper anterior, 0.55 mr in upper posterior, 2.75 mr in lower anterior, and 1.92 mr in lower posterior teeth.

  • PDF

디지털 방사선영상 시스템에서 산란선이 영상 품질에 미치는 영향 (A Study of Scattered Radiation Effect on Digital Radiography Imaging System)

  • 백철하
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권1호
    • /
    • pp.71-78
    • /
    • 2017
  • 디지털 방사선영상 시스템에서 산란선은 피검사체와 엑스선의 반응에 의해 발생하는 근원적인 현상이다. 방사선 투사영상은 일차선에 의해 형성되는 감쇠정보를 영상화 하므로 산란선은 투사영상에서 노이즈로써 작용한다. 본 연구에서는 다양한 검사조건에서 발생하는 산란선을 빔 저지체(beam stopper)를 이용하여 정량화하고 동시에 반 산란 격자의 효과를 확인하였다. 또한 산란선이 영상의 품질에 미치는 영향을 확인하기 위해 산란선에 의해 저하되는 대조도 대 잡음비를 측정하였다. 본 연구를 통해 산란선은 피검사체의 두께 및 공기층(air gap)에 지배적인 경향을 가짐을 확인하였다. 또한 산란선은 영상의 대조도를 현격히 저하시킴을 정량적으로 측정하였다. 산란선을 저감하기 위해 격자를 장착함으로써 상당량의 산란선을 저감할 수 있었으나 여전히 두꺼운 피검사체에 대해 많은 양의 산란선이 남아 있음을 확인하였다. 본 연구에서는 산란선을 정량화 하는 방법론을 제시하였으며, 향후 시스템의 최적화에 중요한 역할을 할 수 있을 것으로 기대된다.

산란선이 간접변환방식 엑스선 검출기의 신호 및 노이즈 특성에 미치는 영향에 관한 연구 (A Study on the Scatter X-ray Signal and Noise Characteristics of Indirect Conversion-Type Detector for Radiography)

  • 김준우
    • 한국방사선학회논문지
    • /
    • 제15권3호
    • /
    • pp.345-353
    • /
    • 2021
  • 디지털 래디오그라피 이미징 시스템으로 환자의 병변 진단에 있어 도움을 줄 수도 있으나 인체에 입사되는 엑스선이 물질과의 상호작용으로 인해 산란선이 발생되면 엑스선 영상의 신호 및 노이즈 특성에 영향을 미치게 된다. 인체를 폴리메틸메타아크릴레이트(polymethyl methacrylate, PMMA)로 간주하고 PMMA에서 발생되는 산란선이 엑스선 영상에 미치는 특성을 관찰하기 위해 공간 영역에서 신호 및 노이즈 분석뿐만 아니라 공간주파수 영역에서 노이즈-파워 스펙트럼(noise-power spectrum, NPS) 그리고 제로주파수에서 양자검출효율(detective quantum efficiency, DQE)을 계산하였다. PMMA 두께 증가에 따라 신호는 감소, 노이즈는 증가하였으며 전반적인 공간주파수에서 노이즈-파워 스펙트럼의 저하가 확인되었다. 이러한 특성을 바탕으로 제로주파수 성능 또한 저하되는 결과를 보였다. 간접변환방식 검출기의 산란선에 의한 제로주파수 성능을 보다 정량적으로 분석하기 위해 몬테칼로 시뮬레이션과의 비교분석이 이루어져야 할 것이다.

디지털유방촬영에서 Geant4-GATE를 이용한 산란선의 영향분석과 감소방안에 관한 연구 (Analysis of Scatter Ray Distribution Using GEANT4-GATE Simulation and Effectiveness of Silicone Pad in Digital Mammography)

  • 김명수;김영근;장영일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권3호
    • /
    • pp.175-180
    • /
    • 2019
  • In this study, we have researched the effectiveness of silicone pad. A distribution of scatter ray in mammography was evaluated using Monte-Carlo (MC) simulation technique and then a silicone pad was applied to remove the scatter ray for improving image quality. Molybdenum target and Molybdenum filter combination made a difference of 59.8% to a number of photon at 17.5 keV. On the other hand, Tungsten target and Rhodium filter showed a variation of 24.5% at 20 keV. Mean 68 of SNR was increased in Selenia and mean 1.04 of SNR was raised in Senographe. Silicone pad was significantly effective to reduce the scatter ray that was generated by primary X-ray. It can decrease an absorption rate of scatter ray to patient body and whilst it improve the image quality from increasing SNR.