A Study on the Directional Dependence of Scatter Ray in Radiography

X선 촬영시 산란선 방향 의존성에 관한 연구

  • Oh, Hyun-Joo (Dept. of Radiotechnology, Sin Gu College) ;
  • Kim, Sung-Soo (Dept. of Radiotechnology, Sin Gu College) ;
  • Kim, Young-Il (Dept. of Radiotechnology, Sin Gu College) ;
  • Lim, Han-Young (Dept. of Radiotechnology, An San Junior College) ;
  • Kim, Heung-Tae (Dept. of Radiotechnology, Sin Heung Junior College) ;
  • Lee, Who-Min (Dept. of Radiotechnology, Dong Nam Junior Health College) ;
  • Kim, Hak-Sung (Dept. of Radiotechnology, Dong Nam Junior Health College) ;
  • Lee, Sang-Suk (Dept. of Radiotechnology, Dong Nam Junior Health College)
  • 오현주 (신구전문대학 방사선과) ;
  • 김성수 (신구전문대학 방사선과) ;
  • 김영일 (신구전문대학 방사선과) ;
  • 임한영 (안산전문대학 방사선과) ;
  • 김흥태 (신흥전문대학 방사선과) ;
  • 이후민 (동남보건전문대학 방사선과) ;
  • 김학성 (동남보건전문대학 방사선과) ;
  • 이상석 (동남보건전문대학 방사선과)
  • Published : 1995.06.30

Abstract

In this pauper, the back, forward, side and $45^{\circ}$ oblique scatter dose were measured the X-ray exposure conditions 60, 80, 100, 120kV, FFD 100cm, FS $20\times20cm$, toward the $25\times25cm\times10\sim20cm$ of solid water, paraffin and MiX-DP phantom, and Pb, Cu, Al, and styrofoam meterials, by the electrometer and 5.3 cc ionization chamber. The obtained results are summarized as following. 1. The percentage depth dose(PDD) at the range of the diagnostic x-ray energy were appeared 50 % depth dose at the 2 cm depth with 60 kV, and 5 cm depth with 120 kV X-ray, 10 % depth dose at the 10 cm depth with 60 kV and 14 cm depth with 120 kV X-ray, 5 % below depth dose at the 20 cm depth. 2. The back scatter dose which were generated the surface of Pb, Cu and Al metal plates were 10 % below, and than the back scatter dose at the Pb plate were a most amount of these which were about 10 %, and were appeared the order of Cu and Al. 3. The percentage forward scatter were appeared from 50 % to 65 %, and the more phantom thicknees become, the more forward scatter were increased with the ratio of 5 % per 5 cm thickness. 4. The percentage back scatter which were generated the tissue equivalence meterials solid water, paraffin and MiX-DP were from 20 % to 40 %, and than the back scatter dose at the solid water were a mest amount of those, and paraffin and MiX-DP were appeared with the next values. 5. The percentage $90^{\circ}$ lateral and $45^{\circ}$ oblique side scatter dose were measured from 4 % to 12 %. a most amount of scatter dose which were generated from the patient in radiography were the forward scatter, the next values were the back scatter, the third values were the $90^{\circ}$ lateral scatter.