• 제목/요약/키워드: X-ray radiography and digital radiography (DR)

검색결과 48건 처리시간 0.024초

디지털 방사선영상 시스템의 기본적 원리 (Physical principles of digital radiographic imaging system)

  • 최진우;이원진
    • Imaging Science in Dentistry
    • /
    • 제40권4호
    • /
    • pp.155-158
    • /
    • 2010
  • Digital radiographic systems allow the implementation of a fully digital picture archiving and communication system (PACS), and provide the greater dynamic range of digital detectors with possible reduction of X-ray exposure to the patient. This article reviewed the basic physical principles of digital radiographic imaging system in dental clinics generally. Digital radiography can be divided into computed radiography (CR) and direct radiography (DR). CR systems acquire digital images using phosphor storage plates (PSP) with a separate image readout process. On the other hand, DR systems convert X-rays into electrical charges by means of a direct readout process. DR systems can be further divided into direct and indirect conversion systems depending on the type of X-ray conversion. While a direct conversion requires a photoconductor that converts X-ray photons into electrical charges directly, in an indirect conversion, lightsensitive sensors such as CCD or a flat-panel detector convert visible light, proportional to the incident X-ray energy by a scintillator, into electrical charges. Indirect conversion sensors using CCD or CMOS without lens-coupling are used in intraoral radiography. CR system using PSP is mainly used in extraoral radiographic system and a linear array CCD or CR sensors, in panoramic system. Currently, the digital radiographic system is an important subject in the dental field. Most studies reported that no significant difference in diagnostic performance was found between the digital and conventional systems. To accept advances in technology and utilize benefits provided by the systems, the continuous feedback between doctors and manufacturers is essential.

Digital Radiography System에서 X선 광자 검출 방식에 따른 선량 및 화질 특성에 관한 연구 (A Study on Dose and Image Quality according to X-ray Photon Detection Method in Digital Radiography System)

  • 홍선숙;김호철
    • 전자공학회논문지
    • /
    • 제50권12호
    • /
    • pp.247-253
    • /
    • 2013
  • 본 연구의 목적은 Direct DR(Digital Radiography), Indirect DR, I.I(Image Intensifier) DR에서 X선 광자 검출 방식에 따른 선량측정 및 획득된 영상을 정량적이고 객관적인 측정을 통해 DR System을 비교 평가 하는 것이다. Rando phantom을 사용하여 입사표면선량을 측정하였으며, 측정된 입사표면선량 값을 통해 PCXMC 프로그램을 사용하여 유효선량과 방사선 조사로 인한 위험을 평가하였다. 21cm 아크릴 phantom을 사용하여 SNR(Signal to Noise Ratio), NPS(Noise Power Spectrum), CNR(Contrast to Noise Ratio)을 측정하였으며, 측정값은 통계학적 분석기법을 사용하여 유의성을 평가하였다. 입사표면선량, 주요장기선량, 유효선량 모두 direct DR이 가장 낮게 측정되었으며, direct DR 선량을 기준으로 I.I type DR은 약 1.3배, indirect DR은 약 2.4배 높은 선량 비율로 측정되었다. 방사선량에 따른 위험도 역시 동일한 비율로 측정되었다. SNR 측정 결과 direct DR측정값을 기준으로 I.I DR은 약 7.25배, indirect DR이 약 1.48배 낮은 비율로 측정되었다. CNR 측정 결과 direct DR 측정값을 기준으로 I.I DR은 약 1.16배 높고, indirect DR이 약 0.87배 낮은 비율로 측정되었다. 따라서 a-selenium 검출소자를 사용하여 X선 광자를 검출하는 방식인 direct DR은 적은 선량으로 우수한 화질의 영상을 구현함으로써 선량에 민감한 소아나 생식선이 포함된 검사 등에 유용할 것으로 사료된다. 또한 많은 진단 정보를 위한 영상 평가가 요구되는 경우에는 indirect DR이 유용할 것으로 판단된다.

X-ray 흉부영상 FIlm/Screen, CR, DR Resolution과 Density 비교평가 (A comparative study for resolution and density of chest imaging using film/screen, CR and DR)

  • 안병주
    • 한국방사선학회논문지
    • /
    • 제4권1호
    • /
    • pp.25-30
    • /
    • 2010
  • 이 연구 목적은 흉부영상의 진단에 적절한 해상력과 음영에 대한 적절한 평가를 위해서다. 해상력을 비교하기 위해서, linear 해상력 팬텀을 사용하여 film/screen(선생님이 원하시는 conventional radiography : film/screen), CR, DR, 촬영했다. 해상력을 비교하기 위해 2명의 영상의학과 전문의와 3명의 방사선사가 블라인드 테스트를 통하여 평가했다. DR 은 3.95 필름/ 스크린은 3.58, CR은 3.48의 평가가 나왔다. 음영에 대해 분석은, CR, DR의 film/screen의 정상적인 흉부영상 50장을 선택했다. 이 흉부영상에서 7부위(폐야, 폐야 윤곽, 종격동 I, 종격동 II, 심장 음영 I, 심장음영 II, 횡격막)을 정하여 덴시토미터(농도계)을 사용하여 음영을 평가했다. 우리의 분석 방법은 낮은 영상(음영)을 0에서부터 가장 우수한 영상(음영) 2를 정한 일본의 흉부 x-ray 평가 방법을 적용했다. DR의 경우 종격동 1, 종격동2, 심장 1, 심장2, 횡격막에서 2점을 기록하여 우수했다. 이와 반대로 CR에서는 폐부위와 폐음영 부위에서 2점으로 우수했다. 결론적으로, 해상력과 음영에 비교하면 후처리 알고리즘과 작은 픽셀 사이즈에 의한 DR은 CR과 film/screen 보다 우수하다고 도출하였다.

X선 기기의 자동화를 위한 BLDC 모터 제어 장치 (BLDC Motor Control Unit for Automation of X ray Equipment)

  • 김태곤;김영표;천민우
    • 한국항행학회논문지
    • /
    • 제15권5호
    • /
    • pp.833-838
    • /
    • 2011
  • 진단용 X선 기기는 다양한 장치의 개발에 힘입어 보다 효과적이고 정밀한 진단이 가능하게 되었다. 정밀 진단이 가능하게 되면서 X선 기기는 임상의학에 있어 가장 기본적이고 핵심적인 진단 장치로 자리 잡고 있다. X선을 이용한 영상획득 분야에서는 영상의 획득 시간 단축과 전송이 용이하고, 조사선량의 감소가 가능한 DR(Digital Radiography)의 사용이 확대되고 있다. 하지만 DR은 1개의 디텍터를 이용하는 구조로 되어있어 기존의 X선 장치와는 달리 구조적인 변경이 필요하며 촬영위치에 따라 디텍터를 원하는 위치까지 움직여야하는 단점을 가진다. 따라서 본 연구에서는 BLDC 모터와 PID 제어방식을 사용해 DR에서 가장 움직임이 많은 디텍터의 상하, 좌우, 회전의 3축 위치자동 제어 시스템을 설계 제작하고 그 성능을 평가 하였다.

A Study of the Relationship between Absorbed Energy and DR Pixel Values Using SPEC-78

  • Kim, Do-Il;Lee, Hyoung-Koo;Kim, Sung-Hyun;Ho, Dong-Su;Choe, Bo-young;Suh, Tae-Suk
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2003년도 제27회 추계학술대회
    • /
    • pp.69-69
    • /
    • 2003
  • Flat panel based digital radiography (DR) systems have recently become useful and important in the field of diagnostic radiology. For DRs with amorphous silicon photosensors, CsI(TI) is normally used as the scintillator, which produces visible light corresponding to the absorbed energy. The visible light photons are converted into an electric signal in the amorphous silicon photodiode. In order to produce good quality images, we need to understand the detailed behavior of DR detectors in radiation. We, therefore, investigated the relationship between DR outputs and X -ray in terms of absorbed energy, using the SPEC-78, X-ray energy spectrum model. We calculated the total filtration of X-ray equipment measuring air exposure and this value was used in the calculation of absorbed energy. The relationship between DR output and the absorbed energy of the X-ray was obtained by matching the absorbed energy with pixel values of real images under various conditions. It was found that the relationship between these two values was almost linear. The results were verified using phantoms made of water and aluminium. The pixel value of the phantom image was estimated and compared with previous results under various conditions. The estimated pixel value coincided with the results, although the effect of scattered photons introduced some errors.

  • PDF

의료용 디지털방사선영상의 공간분해능 최적화에 의한 소듐냉각고속로 연료봉 내부의 소듐 충전상태 평가 (Evaluation of the Filling Sodium States Inside the Fuel rod of Sodium-Cooled Fast Reactor by Optimized Spatial Resolution in Medical Digital Radiographic Images)

  • 성열훈
    • 한국방사선학회논문지
    • /
    • 제10권2호
    • /
    • pp.117-124
    • /
    • 2016
  • 본 연구에서는 디지털 의료용 X선을 이용하여 소듐냉각고속로 금속연료봉 내부의 소듐 충전상태를 평가하고자 하였다. 의료용 X선은 디지털방사선(digital radiography, DR)시스템을 사용하였다. 최상의 공간분해능을 도출하기 위해 X선관의 초점크기와 디지털영상후처리 방법을 변화시켰다. 이때 텅스텐을 이용한 에지방법의 변조전달함수(modulation transfer function, MTF)를 사용하여 선예도(0.5 MTF)와 해상도(0.1 MTF) 를 평가하였다. 그 결과 소초점에서 영상후처리의 대조도를 강화시킨 조건에서 3.871 lp/mm (0.1 MTF)와 3.290 lp/mm (0.5 MTF)의 공간분해능을 얻었다. 결론적으로 이러한 결과는 디지털 의료용 X선을 이용하여 소듐냉각고속로 금속연료봉 내부의 소듐 충전상태를 관찰할 수 있었다.

CR과 DR 영상화질의 정량적 비교분석 (Quantitative Analysis and Comparison of DR and CR image quality)

  • 박혜숙;서장연;정진화;이창래;조효민;김희중
    • 한국방사선학회논문지
    • /
    • 제1권1호
    • /
    • pp.31-37
    • /
    • 2007
  • 본 연구의 목적은 CR(Computed Radiography)과 DR(Digital Radiography)장비의 각 Detector를 통해 획득된 영상의 화질을 비교 분석하기 위한 것이다. CR(AGFA MD 4.0 General plate, JAPAN)과 DR(HOLOGIC nDirect Ray, USA)에 대한 영상평가의 주요인자인 MTF(Modulation transfer function), NPS(Noise power spectrum), Photon fluence, DQE(Detective quantum efficiency)를 정량적인 값으로 도출하여 비교한 결과 CR이 DR보다 우수하게 나타났다. 본 연구의 결과는 CR과 DR장비의 Image quality를 정량적으로 평가할 수 있을 뿐만 아니라 이 장비들을 유지, 보수하는데도 도움이 될 것으로 사료된다.

  • PDF

비공학도를 위한 X-ray 영상촬영 시스템 해상력 평가 방법 (An Evaluation Method of X-ray Imaging System Resolution for Non-Engineers)

  • 우정은;이용금;배석환;김용권
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제35권4호
    • /
    • pp.309-314
    • /
    • 2012
  • Digital Radiography(DR) 시스템은 임상현장에서 아날로그 시스템을 대체하고 널리 이용되고 있다. DR을 이용하여 얻어진 X선 영상의 해상력을 결정짓는 요소에는 이용되는 검출기의 고유 해상력, 피사체의 대조도 및 특성, X선 선질, X선원의 산란, DR 검출기의 성능, X선 변환효율 및 초점의 크기, 피사체의 움직임 등이 있다. DR 검출기를 구성하는 요소에는 X선 포획 요소, 커플링 요소, 정보수집 요소가 있는데 이들은 시스템의 성능에 영향을 미치며, 그 성능은 해상력으로 평가된다. 의료영상 시스템의 해상력은 촬영대상물의 조직 간의 해부학적 영상을 구분하는 능력을 나타낸다. 해상력 평가를 위해 Modulation Transfer Function(MTF)이 보편적으로 이용되고, MTF는 입력 공간주파수 성분에 대한 출력 공간주파수 성분의 비를 나타내는데, 수학적으로 MTF는 Point Spread Function(PSF) 입력에 대한 시스템의 주파수 응답이며 Edge Phantom을 이용한 결과 영상에서 추출된 Line Spread Function(LSF)을 Fourier Transform하면 얻을 수 있다. 일반적으로 임상현장에서 의료영상시스템의 이용 및 관리의 책임은 방사선사가 맡고 있지만, MTF를 측정하기 위해서는 공학적, 수학적 기초 및 C, Fortran, Matlab등의 프로그램 작성 능력이 필요하기 때문에 비 공학도는 정확한 측정이 불가능하다. 의료영상 시스템의 성능 관리 및 최상의 상태를 유지하기 위해 시스템의 성능평가가 이뤄져야 하는데, 이를 위해 본 연구에서는 비공학도가 해상력 성능평가를 할수 있도록 ImageJ 및 Excel을 이용하여 해상력 평가를 할 수 있도록 방법을 제시하고, 제안된 방법을 이용해 계산된 결과와 프로그래밍을 이용해 계산된 결과의 비교를 통해 본 논문에서 제시하는 방법의 유용성을 확인하였다.

DR Responses to X-Ray: in Terms of Absorbed Energy

  • Kim, Do-Il;Lee, Hyoung-Koo;Kim, Sung-Hyeon;Ho, Dong-Su;Suh, Tae-Suk;Choe, Bo-Young
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.389-392
    • /
    • 2002
  • Digital radiography (DR) is being developed for numerous applications in medical imaging. For understanding DR image, it is necessary to comprehend DR responses to X-ray in terms of absorbed energy. This study reports on the relationship of absorbed energy in the scintillator vs. pixel value of detector. Pixel value and exposure were measured from 50 kVp to 120 kVp until the detector was saturated. For representing radiation produced at the X-ray tube, we used program Srs-78 and compared experimental exposure with calculated exposure. Absorbed energy was acquired using spectrum and we got the relation between the two values.

  • PDF

방사선 디텍터의 Noise Power Spectrum: I. 영상의 평균을 사용한 측정 (Noise Power Spectrum of Radiography Detectors: I. Measurement Using the Averages of Images)

  • 김동식;이은애
    • 전자공학회논문지
    • /
    • 제53권12호
    • /
    • pp.120-127
    • /
    • 2016
  • 디지털 x선 영상을 획득하기 위하여 최근에는 DR(digital radiography) 기술에 근거한 방사선 디텍터의 개발이 활발하게 진행되고 있다. 이러한 방사성 디텍터의 잡음 특성은, 균일한 노출에서 획득한 영상을 사용하여 NNPS(normalized noise power spectrum)를 측정하여 관찰한다. 이때 고정형태잡음(fixed pattern noise)을 제거하기위하여 두 장의 영상 차를 사용한다. 본 논문에서는 보다 정확한 NNPS를 측정하기 위하여, 먼저 여러 장의 영상을 획득하여 두 장의 평균영상을 구하고 그의 차를 사용하여 NNPS를 구하는 방법을 제안하였다. 이때 여러 장의 영상들의 평균으로 인하여 NNPS 값이 실제 값보다 작아지는데, 이러한 NNPS의 보정을 위하여, 평균할 때 사용한 영상 개수의 함수인 보정 상수도 함께 제안하였다. 또한 평균영상의 비를 사용하여 NNPS를 구하는 방법도 제안하였다. 실제 방사선 디텍터에서 획득한 영상을 사용하여 NNPS를 측정하는 실험을 통하여, 제안한 방법으로 NNPS 보다 정확하게 구할 수 있음을 관찰하였다.