• Title/Summary/Keyword: X-ray radiography

Search Result 519, Processing Time 0.028 seconds

Testing and Analysis of Tube Voltage and Tube Current in The Radiation Generator for Mammography (유방촬영용 방사선발생장치의 관전압과 관전류 시험 분석)

  • Jung, Hong-Ryang;Hong, Dong-Hee;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Breast shooting performance management and quality control of the generator is applied to the amount of current IEC(International Electrotechnical Commission) 60601-2-45 tube voltage and tube current are based on standards that were proposed in the analysis of the test results were as follows. Tube voltage according to the value of the standard deviation by year of manufacture from 2001 to 2010 as a 42-3.15 showed the most significant, according to the year of manufacture by tube amperage value of the standard deviation to 6.38 in the pre-2000 showed the most significant, manufactured after 2011 the standard deviation of the devices, the PAE(Percent Average Error) was relatively low. This latest generation device was manufactured in the breast of the tube voltage and tube diagnosed shooting the correct amount of current to maintain the performance that can be seen. The results of this study as the basis for radiography diagnosed breast caused by using the device's performance and maintain quality control, so the current Food and Drug Administration "about the safety of diagnostic radiation generator rule" specified in the test cycle during three years of self-inspection radiation on a radiation generating device ensure safety and performance of the device using a coherent X-ray(constancy) by two ultimately able to keep the radiation dose to the public to reduce the expected effect is expected.

Rate of Transformation and Normal Range about Cardiac Size and Cardiothoracic Ratio According to Patient Position and Age at Chest Radiography of Korean Adult Man (한국인 성인 남성의 흉부 방사선영상에서 자세와 연령에 따른 심장 크기 및 심흉비의 정상 범위와 변환율)

  • Joo, Young-Cheol;Lim, Cheong-Hwan;Kim, Yun-Min;Jung, Hong-Ryang;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.179-186
    • /
    • 2017
  • Purpose of this study is present the normal range of cardiac size and cardiothoracic ratio according to patient position(chest PA and AP) and age of Korean adult male on digital chest X - ray, And to propose a mutually compatible conversion rate. 1,024 males were eligible for this study, among 1,300 normal chest patients who underwent chest PA and low-dose CT examinations on the same day at the 'S' Hospital Health Examination Center in Seoul From January to December 2014. CS and CTR were measured by Danzer (1919). The mean difference between CS and CTR was statistically significant (p<0.01) in Chest PA (CS 135.48 mm, CTR 43.99%) and Chest AP image (CS 155.96 mm, CTR 51.75%). There was no statistically significant difference between left and right heart in chest PA and AP images (p>0.05). CS showed statistically significant difference between Chest PA (p>0. 05) and Chest AP (p<0.05). The thorax size and CTR were statistically significant (p<0.01) in both age and chest PA and AP. Result of this study, On Chest AP image CS was magnified 15%, CTR was magnified 17% compare with Chest PA image. CS and CTR were about 10% difference by changing posture at all ages.

Radiologic Evaluation of Intraabdomenal Masses in Childhood (소아복부 종괴의 방사선학적 고찰)

  • Kwon, Hyuk-Po;Byun, Woo-Mok;Hwang, Mi-Soo;Kim, Sun-Yang;Chang, Jae-Chun;Park, Bok-Hwan
    • Journal of Yeungnam Medical Science
    • /
    • v.5 no.1
    • /
    • pp.33-42
    • /
    • 1988
  • The abdominal tumors in children are different from those of adult. These tumors are the third most common one, preceded by leukemia and brain tumors, in children under 15 years. X-ray examination is the most important method among diagnostic approaches. The role of diagnostic imaging is to identify the precise anatomic location and extent of pathologic process with the minimal number of imaging procedures. 23 cases of abdominal tumors were reviewed in respect of age incidence, site of origin, radiologic findings. The results are briefly summarized as follows : 1. Neuroblastoma was the most common(6 cases) and wi1m's tumor(5 cases), choledocal cyst(4 cases), ovarian mass(3 cases), hydronephrosis(2 cases), were descending order in frequency. 2. The most common site was retroperitoneum(60%). Kidney was the single most common site of origin. 3. Radiologic findings. The most common findings of plain radiography was ill defined soft tissue mass and this method was helpful in the presence of calcification especially in neuroblastoma. Ultrasonographic pattern was anechoic(cystic), echoic or mixed pattern, but this method provide less precise anatomical details, nevertheless ultrasonography wes paticullary useful imaging modality for the pediatric abdominal tumors. IVP findings were renal displacement, caliceopelvic system distortion or nonvisualization of kidney, these information was helpful in determining the location of tumors. CT scan showed homogenous or inhomogenous, cystic or solid, mass with their anatomic location. 4. Ultrasonography was the most widely used specific diagnostic method, but had limited value in detecting the anatomic location of tumors. CT scan was superior to ultrasound for determining the extent of tumors.

  • PDF

The effects of the correction exercise program combined with stretching and elastic band exercise on femoral intercondylar distance, Q-angle, plantar pressure in undergraduate with genu varum (탄성밴드운동과 스트레칭을 이용한 교정운동프로그램이 내반슬 대학생들의 무릎간 간격, Q-각 및 족압의 변화에 미치는 영향)

  • Yu, Byong-Kyu;Kim, Eun-Hye
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.2064-2072
    • /
    • 2015
  • The aim of this study is to identify the effects of the correction exercise program on femoral intercondylar distance, Q-angle and plantar pressure in undergraduate with genu varum. A experimental study with a randomized controlled trial design was used. Thirty subjects with genu varum were allocated in two groups: the experimental group (n=15) or the control group (n=15). The experimental group conducted correction exercise program for 30 minutes a day, 5 times a week, for 6 weeks, while the control group did not perform any exercise. The correction exercise program group showed a significant decreased femoral intercondylar distance, plantar pressure of M 4, M 5 (Metatarsal 4, 5). Also the correction exercise program group significantly increased Q-angle, plantar pressure of Toe 2-5 and M 1, M 2, M 3 (Metatarsal 1, 2, 3) (Rt, Lt) (p<.05). Thus, we suggested that the correction exercise program may be suitable intervention to improve normal alignment in undergraduate with genu varum.

Evaluation on Organ Dose and Image Quality by Changing kVp and Ion Chamber Combination while Taking Digital Chest Lateral Decubitus PA Projection (디지털 흉부 측와위 후전방향 검사 시 Ion chamber조합 설정과 관전압 변화에 따른 장기선량 및 화질 평가)

  • Lee, Jin-Soo;Park, Hyong-Hu
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.1
    • /
    • pp.316-323
    • /
    • 2015
  • In this study, we analyzed radiation dose and MTF with setting of Ion chamber and changing kVp so that we are able to suggest acquiring optimized diagnostic images and minimizing patient dose. we assumed right lateral decubitus position among chest decubitus projection and set 7 combination of Ion chamber. By changing kVp(100, 110, 120, 130kVp), we exposed x-ray five times respectively and calculated average value after measuring entrance dose. we input the entrance dose value to PCXMC Monte carlo simulation tool and calculated organ dose and effective dose. Then we did physical image evaluation with MTF for the purpose to compare image quality. As a result, the high kVp, entrance dose is reduced. As change of ion chamber, when selecting second ion chamber, both organ dose and effective dose were the lowest. In contrast, selecting first ion chamber was the highest. MTF is superior to set second Ion chamber and using 120 kVp. Consequently, when taking chest right lateral decubitus using Digital radiography, the optimized combination which have both reducing dose efficiently without declining image quality and aquring good qualified image is set 120 kVp and selecting second Ion chamber.

AN EXPERIMENTAL STUDY OF MANDIBULAR FRACTURE WOUND HEALING IN THE CALCIUM DEFICIENT RAT (저칼슘식이가 백서의 하악골 골절치유에 미치는 영향에 관한 실험적 연구)

  • LEE Sang-Hoon;HWANG Eui-Hwan;LEE Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.123-140
    • /
    • 1997
  • The purpose of this study was to investigate effects of osteoporosis on fracture wound healing in the calcium deficient rat. To research the experiment some ten-week old Wistar strain rats with approximately 300 gms weight were selected. Then, the rats were divided into two groups: Normal diet group(rats given a normal diet before and after bone fracture) and Low calcium diet group(rats given a low calcium diet before and after bone fracture). Both groups had been provided with each diet for three weeks. When the rats became thirteen weeks old, the mandibular angle of rats in both groups was artificially fractured for test. The healing of fracture wounds was reviewed by using soft x-ray radiography and /sup 99m/Tc-MDP bone scan and also histopathologic examination. The obtained results were as follows : 1. The radiolucency of the fracture site for the Normal diet group started to decrease from the 14th day since the experiment was made, while the Low calcium diet group began decrease in the radiolucency from the 21st day of the experiment. The radiolucency for the Normal diet group disappeared at the 42nd day, but one for the Low calcium diet group disappeared at the 56th day of the experiment. 2. The highest uptake rate of /sup 99m/Tc-MDP stood at the 14th day of the experiment in the Normal diet group and the Low calcium diet group's maximum rate was recorded at the 21st day of the experiment. These both groups were gradually experiencing decrease in the uptake rate as the experiment time was going on. However, the uptake rate in the Low calcium diet group was lower than one in the Normal diet group. 3. For the Normal diet group, the newly formed trabeculae, which were similar to one of the surroundung bone, were seen at the 42nd day of the experiment. On the other hand, the Low calcium diet group showed at the 56th day of the experiment that the osteoporotic findings looked weak, irregular trabeculae, and also large bone marrow space were observed clearly. As a result of the above experiment, it is said that the healing of the fracture can be completed for both groups, the Normal diet group and the Low calcium diet group. However, the amount of the newly formed bone wound in the Low calcium diet group is rather decreased compared to one in the Normal diet group and at the same time the healing of the fracture is delayed in the Low calcium diet group. Consequently, for the successful healing of fracture in osteoporosis, it is considered that the management of the etiologic factors of osteoporosis must be preceded. The more study of calcium metabolism and functions of osteoblast and osteoclast needs to proceed on.

  • PDF

Benign Tumor-Like Developmental Salivary Gland Defect (양성 종양과 유사한 형태를 가진 발육성 타액선 골결손)

  • An, Seo-Young;Kim, Yong-Gun;Jung, Jae-Kwang
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.301-307
    • /
    • 2012
  • 50-year-old female and 50-year-old male were referred to the department of the oral and maxillofacial surgery of Kyungpook national university dental hospital with asymptomatic lesions on their posterior mandibular body areas. They were discovered incidentally on panoramic radiographs during routine dental examination. Physical examination revealed no remarkable findings. Each panoramic radiograph showed well defined radiolucent lesions without hyperostotic border on their posterior mandibular body area. At first they were diagnosed as benign tumors because they looked like multilocular pattern and one of the patient showed discontinuity of mandibular canal within the lesion. CT scans demonstrated well demarcated and irregular lingual depression filled with fat tissue and they were diagnosed as developmental salivary gland defects. One of the lesion showed no change on follow-up panoramic radiograph after 4 months. Developmental salivary gland defects resembling benign tumor are atypical cases and it is suggested that confirmatory imaging using CT or MRI should be taken.

Effect of exposure time and image resolution on fractal dimension (노출 시간과 영상 해상도가 프랙탈 차원값에 미치는 영향)

  • An Byung-Mo;Heo Min-Suk;Lee Seung-Pyo;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won;Kim Jong-Dae
    • Imaging Science in Dentistry
    • /
    • v.32 no.2
    • /
    • pp.75-79
    • /
    • 2002
  • Purpose : To evaluate the effect of exposure time and image resolution on fractal dimension calculations for determining the optimal range of these two variances. Materials and Methods : Thirty-one radiographs of the mandibular angle area of sixteen human dry mandibles were taken at different exposure times (0.01, 0.08, 0.16, 0.25, 0.40, 0.64, and 0.80 s). Each radiograph was digitized at 1200 dpi, 8 bit, 256 gray level using a film scanner. We selected an Region of Interest (ROI) that corresponded to the same region as in each radiograph, but the resolution of ROI was degraded to 1000, 800, 600, 500, 400, 300, 200, and 100 dpi. The fractal dimension was calculated by using the tile-counting method for each image, and the calculated values were then compared statistically. Results: As the exposure time and the image resolution increased, the mean value of the fractal dimension decreased, except the case where exposure time was set at 0.01 seconds (α = 0.05). The exposure time and image resolution affected the fractal dimension by interaction (p<0.001). When the exposure time was set to either 0.64 seconds or 0.80 seconds, the resulting fractal dimensions were lower, irrespective of image resolution, than at shorter exposure times (α = 0.05). The optimal range for exposure time and resolution was determined to be 0.08- 0.40 seconds and from 400-1000 dpi, respectively. Conclusion : Adequate exposure time and image resolution is essential for acquiring the fractal dimension using tile-counting method for evaluation of the mandible.

  • PDF

Evaluation of imaging reformation for root and pulp canal shapes of permanent teeth using a cone beam computed tomography (Cone beam형 전산화단층영상을 이용한 영구치 치근과 근관의 형태 평가)

  • Hong, Jong-Hyun;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.37 no.3
    • /
    • pp.165-170
    • /
    • 2007
  • Purpose: To estimate the shape of root and pulp canal using a dental cone beam computed tomography (CBCT) and to evaluate the accuracy of imaging reformation. Materials and Methods: CBCT images were obtained with incisors, premolars, and molars as the destination by using PSR $9000N^{TM}$ Dental CT system (Asahi Roentgen Ind. Co., Ltd, Kyoto, Japan) and i-CAT (Imaging Sciences International, Inc, USA) cone beam CT unit that have different kind of detector and field of view, and compared these with the shape and the size of actual root and root canal. Results: When the measuring value of cone beam computed tomography concerning to each root's bucco-lingual diameter and mesio-distal diameter was compared with the value of the actual root, it reveals an error range $-0.49{\sim}+0.63$ mm at PSR900N and $-0.97{\sim}+1.14$ mm at i-CAT (P>0.05). It was possible to identify and measure PSR$9000N^{TM}$ Dental CT system to the limit $0.48{\pm}0.06mm$ (P>0.05) and i-CAT CBCT to the limit $0.86{\pm}0.09mm$ (P<0.05) on estimating the size and the shape of root canal. Two kinds of CBCT images revealed the useful reproducibility to estimate the shape of root, but there was the difference to estimate the shape of root according to apparatus. The reproducibility of root shape in the image of three-dimensions at PSR 900N is low such as 0.65 mm in a case of minute root canal. Conclusions: CBCT images revealed higher accuracy of the imaging reformation for root and pulp and clinically CBCT is a useful diagnostic tool for the assessment of root and canal. However, there are different qualities of imaging reformation according to CBCT apparatus and limitation of reproducibility for minute root canals.

  • PDF

The Diagnosis and Treatment of Osteoporosis (골다공증의 진단과 치료)

  • Moon, Jun-Sung;Won, Kyu-Chang
    • Journal of Yeungnam Medical Science
    • /
    • v.25 no.1
    • /
    • pp.19-30
    • /
    • 2008
  • Osteoporosis, a disease characterized by low bone mass and microarchitectural deterioration of bone tissue leading to enhanced bone fragility and fracture risk, is a major public health problem. The diagnostic methods for osteoporosis include simple radiography, bone scan, DXA (Dual energy X-ray Absortiometry) and biochemical markers of bone turnover. Optimal treatment and prevention of osteoporosis require modification of risk factors, particularly smoking cessation, adequate physical activity, and attention to diet, in addition to pharmacologic intervention. The estrogens and raloxifene both prevent bone loss in postmenopausal women, and the estrogens probably also decrease the risk of first fracture. There is good evidence that raloxifene prevents further fractures in postmenopausal women who already have had fractures and some evidence that estrogen does as well. Bisphosphonate prevents bone loss and reduces fractures in healthy and osteoporotic postmenopausal women and in osteoporotic men as well. Risedronate is more potent and has fewer side effects than alendronate and reduces the incidence of fractures in osteoporotic women. Calcitonin increases bone mineral density in early postmenopausal women and men with idiopathic osteoporosis, and also reduces the risk of new fractures in osteoporotic women. All of the agents discussed above prevent bone resorption, whereas teriparatide and strontium increase bone formation and are effective in the treatment of osteoporotic women and men. New avenues for targeting osteoporosis will emerge as our knowledge of the regulatory mechanisms of bone remodeling increases, although issues of tissue specificity may remain to be addressed.

  • PDF