Rate of Transformation and Normal Range about Cardiac Size and Cardiothoracic Ratio According to Patient Position and Age at Chest Radiography of Korean Adult Man
![]() |
Joo, Young-Cheol
(Department of Radiology, Samsung Medical Center)
Lim, Cheong-Hwan (Department of Radiological Science, Hanseo University) Kim, Yun-Min (Department of Radiotechnology, Wonkwang Health Science University) Jung, Hong-Ryang (Department of Radiological Science, Hanseo University) Hong, Dong-Hee (Department of Radiological Science, Far East University) |
1 | Galal O, von Sinner W, Azhari N, et al.:Clinical Result and Radiographic Appearance of the Rashkind Double Umbrella Device in Patients with Occlusion of Ductus Arterious, Pediatric radiology, 27, 936-941, 1997 DOI |
2 | Ovenfors, C. O, Hedgcick, M.W: Intensive Care Unit Radiology: Problems of Interpretation. Radiol. Clin., North Am, 16, 407-436, 1978 |
3 | Krovetz LJ, Lester RG, Warden HE: The Diagnosis of Patent Ductus Arteriosus in Infancy, Chest, 42, 241-50, 1962 |
4 | Hamgyum Kim: The Finding on Cardiothracic Ratio in Simple Chest Radiography, Korean Society of Radiological Science, 27(4), 43-48, 2004 |
5 | Seoghee Park, Yungil Lee, Jongwoo Kim: Comparative study in cardiac measurement between standard PA and supine AP views of the chest, J Korean Radil Soc,16(2), 438-442, 1980 DOI |
6 | Kyoobyung Chung, Sook Lee, Insik Park, et al.: A Comparision of Upright Chest PA and Supine Chest AP View, Journal of the Korean radiological society, 15(2), 376-380, 1979 DOI |
7 | Myunghee Yoo, Oaksoon Yim, Seongyui Yoo, et al.: A Stastical Study of Chest Measurements in Normal Senile Korean -Diffefence of Senile Changes in Cardiovascular System, Journal of the Korean radiological society, 16(2), 426-432, 1980 DOI |
8 | Choongsook Hwang: A Study on the Normal Heart Volume of Korean Adults, Journal of the Korean radiological society, 4(1), 1-16, 1968 DOI |
9 | Dongun Choo: Statistical Study on the Teleroe ntgenographic life size of Normal heart of Korean, Aero-Medical Institue ROKAF, 1(4), 1-30, 1952 |
10 | K Nickol,M., A J. Wade: Radilgraphic Heart Size and Cadiothoracic Ratio in Three Ethnic Groups: a basis for a Simple Screening Test for Cadiac Enlargement in Men, British Journal of Radiology, 55, 399-403, 1982 DOI |
11 | Ashcroft, M. T, Miall, W. E: Cardio-Thoracic Ratios in Two Jamaican Commnities, American Journal of Epidemiology, 89, 161-167, 1969 DOI |
12 | Kerwin, A.J: Observation of Heart Size of Natives Living at High Altitudes, American Heart Journal, 28, 69-80, 1944 DOI |
13 | Daehun Kim, Seongjin Ko, Sesik Kang, Junghoon Kim, Changsoo Kim: Computer-Aided Diagnosis for Pulmonary Tuberclusis using Texture Features Analysis in Digital Chest Radiography, JKCA, 11(11), 187-193, 2011 |
14 | Boram Park, Dongwook Sung: A Comparative Study of Image Quality and Radiation Dose with Changes in Tube Voltage and Current for a Digital Chest Radiogray, J Korean Soc Radiol, 62, 131-137, 2010 DOI |
15 | http://kostat.go.kr/ |
16 | J.H. Wouter, Veldhamp, J. M. Lucia: Dose and perceived image qualigy in chest radiography, Eropaean journaral of Radiologry, 72(2), 209-217, 2009 |
17 | Inja Lee, Changnam Kim, Changyeob Lee, Kyeyeon Park: Evaluation of Image According to Exposure Conditions using Contrast-Detail Phantion for Chest Digital Radiography, Korean Society of Radiological Science, 32(1), 25-32, 2009 |
18 | https://www.mfds.go.kr/ |
19 | Seonghee Park. Jaemun Lee, Soonja Han et al.: Evaluation of Cardiac Measurements in Healthy Korean Adults, Journal of the Korean Radiological Society, 14(1), 57-62, 1978 DOI |
![]() |