• Title/Summary/Keyword: X-ray photon spectroscopy

Search Result 25, Processing Time 0.027 seconds

Polymerization of Tetraethoxysilane by Using Remote Argon/dinitrogen oxide Microwave Plasma

  • Chun, Tae-Il;Rossbach, Volker
    • Textile Coloration and Finishing
    • /
    • v.21 no.3
    • /
    • pp.19-25
    • /
    • 2009
  • Polymerization of tetraethoxysilane on a glass substrate was investigated by remote microwave plasma using argon with portions of nitrous oxide as carrier gas. Transparent layer like a thickness of 0.5 ${\mu}m$ 3 ${\mu}m$ were obtained, differing in chemical composition, depending on plasma power and treatment time as well as on ageing time. In general the milder the treatment and the shorter the ageing was, the higher was the content of organic structural elements in the layer. We have identified that the chemical structure of our samples composed of mainly Si O and Si C groups containing aliphatics, carbonyl groups. These results were obtained by X ray photon spectroscopy, Fourier transformed infrared spectroscopy, and scanning electron microscope combined with Energy dispersive X ray spectroscopy.

Surface Dynamics using Coherent X-rays : X-ray Photon Correlation Spectroscopy (코히런트한 X-선을 이용한 표면 거동 연구)

  • Kim Hyeon Jeong
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.22-23
    • /
    • 2003
  • The new method of x-ray photon correlation spectroscopy (XPCS) [1] is developed recently for probing the dynamics of surface height fluctuations as a function of lateral length scale. Measurements were performed on supported polystyrene (PS) films of thicknesses varying from 84 to 333 nm at temperatures above the PS glass transition temperature. Within a range of wave vectors spanning $10^{-3}$ to $10^{-2}$ $nm^{-1}$, good agreement is found between the measured surface dynamics and the theory of overdamped thermal capillary waves on thin films. Quantitatively, the data can be accounted for using the viscosity of bulk PS. (omitted)

  • PDF

In-situ monitoring of oxidation states of vanadium with ambient pressure XPS

  • Kim, Geonhwa;Yoon, Joonseok;Yang, Hyukjun;Lim, Hojoon;Lee, Hyungcheol;Jeong, Changkil;Yun, Hyungjoong;Jeong, Beomgyun;Ethan, Crumlin;Lee, Juhan;Ju, Honglyoul;Mun, Bongjin Simon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.125.2-125.2
    • /
    • 2015
  • The evolution of oxidation states of vanadium is monitored with ambient pressure X-ray photoemission spectroscopy. As the pressure of oxygen gas and surface temperature change, the formations of various oxidation states of vanadium are observed on the surface. Under 100mTorr of the oxygen gas pressure and 523K of sample temperature, VO2 and V2O5 are formed on the surface. The temperature-dependent resistance measurement on grown sample shows a clear metal-insulator transition near 350K. In addition, the measurement of Raman spectroscopy displays the structural change from monoclinic to rutile structures across the phase transition temperature.

  • PDF

Coherent x-ray scattering to study dynamics in thin films (결맞는 X-선 산란을 이용한 박막의 표면 거동 연구)

  • Kim, Hyun-Jung
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.3
    • /
    • pp.143-146
    • /
    • 2005
  • A new method of x-ray photon correlation spectroscopy (XPCS) using coherent x-rays is developed recently for probing the dynamics of surface height fluctuations as a function of lateral length scale. This emerging technique applies the principles of dynamic light scattering in the x-ray regime. The short wavelength and slow time scales characteristic of XPCS extend the phase space accessible to scattering studies beyond some restrictions by light and neutron. In this paper, we demonstrate XPCS to study the dynamics of surface fluctuations in thin supported polymer films. We present experimental verification of the theoretical predictions for the wave vector and temperature dependence of the capillary wave relaxation times for the supported polymer films at melt for the film thicknesses thicker than 4 times of the radius of gyration of polymer. We observed a deviation from the conventional capillary wave predictions in thinner films. The analysis will be discussed in terms of surface tension, viscosity and effective interactions with the substrate.

Deposition of Polytetrafluoroethylene Thin Films by IR-pulsed Laser Ablation (Nd:YAG 레이저에 의한 폴리테트라플루오르에틸렌 박막 증착)

  • Park Hoon;Seo Yu-Suk;Hong Jin-Soo;Chae Hee-Baik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.6 no.1
    • /
    • pp.58-63
    • /
    • 2005
  • PTFE (polytetrafluoroethylene) thin films were prepared from the pellets of the graphite doped PTFE via pulsed laser ablation with 1064 nm Nd:YAG laser. The graphite powder converts the absorbed photon energy into thermal energy which is transmitted to nearby PTFE. The PTFE is decomposed by thermal process. The deposited films were transparent and crystalline. SEM (scanning electron microscopy) and AFM (atomic force microscopy) analyses indicated that the film surface morphology changed to fibrous structure with increasing thickness. The fluorine to carbon ratios of the film were 1.7 and molecular axis was parallel with (100) Si-wafer substrate. These results obtained by XPS (X-ray photoelectron spectroscopy), FTIR (fourier transform infrared spectroscopy) and XRD (X-ray diffraction).

  • PDF

A Novel Method for the Fabrication of Monodispersed Carbon Nanospheres and Their Crosslinked Forms

  • Im, Ji-Eun;Lee, Ha-Na;Li, Jing;Kim, Yong-Rok
    • Bulletin of the Korean Chemical Society
    • /
    • v.35 no.3
    • /
    • pp.871-874
    • /
    • 2014
  • Monodispersed carbon nanospheres (CNSs) were fabricated by a novel method and their structural properties were investigated. CNSs were prepared by the pyrolysis of nanospherical polystyrenes (PS). With the coating of $SiO_2$ shell, PS particles were effectively separated during pyrolysis process which resulted to CNSs with an average diameter of 40 nm. Moreover, CNSs could be crosslinked with each other through the bondings between the functional groups on their surfaces. Morphology of the fabricated carbon spheres and their crosslinked form were characterized by X-ray diffraction (XRD), field-emission scanning electron microscopy (FESEM), transmission electron microscopy (TEM), and fourier transform infrared spectroscopy (FT-IR).

Analysis of Wide-gap Semiconductors with Superconducting XAFS Apparatus

  • Shiki, S.;Zen, N.;Matsubayashi, N.;Koike, M.;Ukibe, M.;Kitajima, Y.;Nagamachi, S.;Ohkubo, M.
    • Progress in Superconductivity
    • /
    • v.14 no.2
    • /
    • pp.99-101
    • /
    • 2012
  • Fluorescent yield X-ray absorption fine structure (XAFS) spectroscopy is useful for analyzing local structure of specific elements in matrices. We developed an XAFS apparatus with a 100-pixel superconducting tunnel junction (STJ) detector array with a high sensitivity and a high resolution for light-element dopants in wide-gap semiconductors. An STJ detector has a pixel size of $100{\mu}m$ square, and an asymmetric layer structure of Nb(300 nm)-Al(70 nm)/AlOx/Al(70 nm)-Nb(50 nm). The 100-pixel STJ array has an effective area of $1mm^2$. The XAFS apparatus with the STJ array detector was installed in BL-11A of High Energy Accelerator Research Organization, Photon Factory (KEK PF). Fluorescent X-ray spectrum for boron nitride showed that the average energy resolution of the 100-pixels is 12 eV in full width half maximum for the N-K line, and The C-K and N-K lines are separated without peak tail overlap. We analyzed the N dopant atoms implanted into 4H-SiC substrates at a dose of 300 ppm in a 200 nm-thick surface layer. From a comparison between measured X-ray Absorption Near Edge Structure (XANES) spectra and ab initio FEFF calculations, it has been revealed that the N atoms substitute for the C site of the SiC lattice.

Resonant inelastic X-ray scattering of tantalum double perovskite structures

  • Oh, Ju Hyun;Kim, Jung Ho;Jeong, Jung Hyun;Chang, Seo Hyoung
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1225-1229
    • /
    • 2018
  • In this paper, we investigated the electronic structures and defect states of $SrLaMgTaO_6$ (SLMTO) double perovskite structures by using resonant inelastic x-ray scattering. Recently, $Eu^{3+}$ doped SLMTO red phosphors have been vigorously investigated due to their higher red emission efficiency compared to commercial white light emitting diodes (W-LED). However, a comprehensive understanding on the electronic structures and defect states of host SLMTO compounds, which are specifically related to the W-LED and photoluminescence (PL), is far from complete. Here, we found that the PL spectra of SLMTO powder compounds sintered at a higher temperature, $1400^{\circ}C$, were weaker in the blue emission regions (at around 400 nm) and became enhanced in near infrared (NIR) regions compared to those sintered at $1200^{\circ}C$. To elucidate the difference of the PL spectra, we performed resonant inelastic x-ray spectroscopy (RIXS) at Ta L-edge. Our RIXS result implies that the microscopic origin of different PL spectra is not relevant to the Ta-related defects and oxygen vacancies.

The New X-ray Induced Electron Emission Spectrometer

  • Yu.N.Yuryev;Park, Hyun-Min;Lee, Hwack-Ju;Kim, Ju-Hwnag;Cho, Yang-Ku;K.Yu.Pogrebitsky
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.5-6
    • /
    • 2002
  • The new spectrometer for X-ray Induced Electron Emission Spectroscopy (XIEES) .has been recently developed in KRISS in collaboration with PTI (Russia). The spectrometer allows to perform research using the XAFS, SXAFS, XANES techniques (D.C.Koningsberger and R.Prins, 1988) as well as the number of techniques from XIEES field(L.A.Bakaleinikov et all, 1992). The experiments may be carried out with registration of transmitted through the sample x-rays (to investigate bulk samples) or/and total electron yield (TEY) from the sample surface that gives the high (down to several atomic mono-layers in soft x-ray region) near surface sensitivity. The combination of these methods together give the possibility to obtain a quantitative information on elemental composition, chemical state, atomic structure for powder samples and solids, including non-crystalline materials (the long range order is not required). The optical design of spectrometer is made according to Johannesson true focusing schematics and presented on the Fig.1. Five stepping motors are used to maintain the focusing condition during the photon energy scan (crystal angle, crystal position along rail, sample goniometer rail angle, sample goniometer position along rail and sample goniometer angle relatively of rail). All movements can be done independently and simultaneously that speeds up the setting of photon energy and allows the using of crystals with different Rowland radil. At present six curved crystals with different d-values and one flat synthetic multilayer are installed on revolver-type monochromator. This arrangement allows the wide range of x-rays from 100 eV up to 25 keV to be obtained. Another 4 stepping motors set exit slit width, sample angle, channeltron position and x-ray detector position. The differential pumping allows to unite vacuum chambers of spectrometer and x-ray generator avoiding the absorption of soft x-rays on Be foil of a window and in atmosphere. Another feature of vacuum system is separation of walls of vacuum chamber (which are deformed by the atmospheric pressure) from optical elements of spectrometer. This warrantees that the optical elements are precisely positioned. The detecting system of the spectrometer consists of two proportional counters, one scintillating detector and one channeltron detector. First proportional counter can be used as I/sub 0/-detector in transmission mode or by measuring the fluorescence from exit slit edge. The last installation can be used to measure the reference data (that is necessary in XANES measurements), in this case the reference sample is installed on slit knife edge. The second proportional counter measures the intensity of x-rays transmitted through the sample. The scintillating detector is used in the same way but on the air for the hard x-rays and for alignment purposes. Total electron yield from the sample is measured by channeltron. The spectrometer is fully controlled by special software that gives the high flexibility and reliability in carrying out of the experiments. Fig.2 and fig.3 present the typical XAFS spectra measured with spectrometer.

  • PDF

Characterization and experimental investigation for gamma-ray shielding competence of basalt-doped polyethylene nanocomposites

  • I.A. El-Mesady;F.I. El-Agawany;H. El-Samman;Y.S. Rammah;A. Hussein;R.A. Elsad
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.477-484
    • /
    • 2024
  • Experimental investigations on gamma - rays attenuation parameters and dielectric spectroscopic properties were done on a polymeric mixture with chemical composition (100-x) polyethylene + x basalt, where x = 0, 1, 3, 5, 10, and 20 wt%. Using the melting blending technique,six nanocomposite polymeric samples were prepared. The linear attenuation coefficient µ of each prepared set of samples was measured using a gamma-ray spectrometer including High Purity Germanium detector (HPGe) at energies 662.5, 1173.24, and 1332.51 keV. Based on the measured values of (µ) and sample density, the other effective shielding parameters were calculated. The values of µ showed an increase with increasing the dopant ratios from 0.0 up to 20.0 wt%. In addition, the µ values decreased with the photon's energy. The µ values were found 0.0847 up to 0.1175 cm-1, 0.0571 up to 0.0855 cm-1, and 0.0543 up to 0.075 cm-1 at 662.5, 1173.24, and 1332.51 keV. for B0 up to B20, respectively. The ATR spectroscopy was done on the prepared samples, and a good evidence of adding the filler to the pure polyethylene (HDPE) was obtained. Besides, an enhancement in dielectric constant by insertion of basalt NPs also recorded and can be attributed to the large dielectric constant of basalt compared to pure HDPE.