• Title/Summary/Keyword: X-ray measurement

Search Result 1,305, Processing Time 0.028 seconds

Evaluation of Strength and Residual Stress in $Si_3N_4/SUS304$ Joint ($Si_3N_4/SUS304$ 접합재의 잔류응력 및 강도평가)

  • 박영철;오세욱;조용배
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.1
    • /
    • pp.101-112
    • /
    • 1994
  • The measurement of residual stress distribution of $Si_3N_4/SUS304$ joint was performed on 23 specimens with the same joint condition using PSPC type X-ray stress measurement system and the two-dimensional elastoplastic analysis using finite element method was also attempted. As results, residual stress distribution near the interface on the ceramic side of the joint was revealed quantitatively. Residual stress on the ceramic side of the joint was turned out to be tensional near the interface, maximum along the edge, varying in accordance with the condition of the joint and variance to be most conspicuous for the residual stress normal to the interface characterized by the stress singularities. In the vicinity of the interface, the high stress concentration occurs and residual stress distributes three-dimensionally. Therefore, the measured stress distribution differed remarkably from the result of the two-dimensional finite-element analysis. Especially at the center of the specimen near the interface, the residual stress, $\sigma_{x}$ obtained from the finite element analysis was compressive, whereas measurement using X-ray yielded tensile $\sigma_{x}$. Here we discuss two dimensional superposition model the discrepancy between the results from the two dimensional finite element analysis and X-ray measurement.

Development and Characteristics of the Soft x-ray transmission W-target tube (W-target 투과 양극형 Soft x-ray tube의 개발 및 특성분석)

  • Kim, Sung-Soo;Kim, Do-Yun
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.4
    • /
    • pp.305-310
    • /
    • 2007
  • The x-ray transmission W-target tube was developed and its characteristics were evaluated. The continuous x-ray was emitted at the tube voltage less than 12kV, and the characteristic x-ray was emitted more than 12kV. From the measurement of the energy distribution and dose of x-ray, it was confirmed that our results are a good agreement with the blown ones. Moreover, in comparison with commercial x-ray tube, it was also found that the characteristics of our x-ray tube is better than the commercial one. Therefore we confirmed that the x-ray tube developed in this study is so good that it can be commercialized.

X-Ray Reflectivity Analysis Incorporated with Genetic Algorithm to Analyze the Y- to X Type Transition in CdA LB Film

  • 최정우;조경상;이희우;이원홍;이한섭
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.5
    • /
    • pp.549-553
    • /
    • 1998
  • The structure and layer distribution of cadmium arachidate Langmuir-Blodgett film were analyzed by the small angle X-ray reflectivity measurements using synchrotron radiation. Y-to X type transition was ocurred during the 39th passage of deposition of cadmium arachidate. Based on the measurement of the consumed area of the monolayer, it was determined that about 27.5 layer was deposited. Using the synchrotron X-ray, the reflectivity profile of cadmium arachidate LB film over the wide range of grazing angle was obtained. The X-ray reflectivity profile was analyzed using the recursion formula. By fitting the location and dispersion of the subsidiary maxima between the Bragg peaks of the measured reflectivity profile with that of the calculated reflectivity profile, the average thickness and the distribution of layer thickness were evaluated. The genetic algorithm was adopted to the fitting of reflectivity profile to evaluate the optimum value of the number distribution of layer. Based on the morphology measurement with an atomic force microscopy (AFM), the domain structure and mean roughness of LB films were obtained. The mean roughness value calculated based on the number of layer distribution obtained from the measurement by AFM is consistent with that obtained from X-ray reflectivity analysis.

Reference X-ray Irradiation System for Personal Dosimeter Testing and Calibration of Radiation Detector

  • Lee, Seung Kyu;Chang, Insu;Kim, Sang In;Lee, Jungil;Kim, Hyoungtaek;Kim, Jang-Lyul;Kim, Min Chae
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.72-78
    • /
    • 2019
  • Background: In the calibration and testing laboratory of Korea Atomic Energy Research Institute, the old X-ray generator used for the production of reference X-ray fields was replaced with a new one. For this newly installed X-ray irradiation system, beam alignment as well as the verification of beam qualities was conducted. Materials and Methods: The existing X-ray generator, Phillips MG325, was replaced with YXLON Y.TU 320-D03 in order to generate reference X-ray fields. Theoretical calculations and Monte Carlo simulations were used to determine initial filter thickness. Beam alignment was performed in three steps to deliver a homogeneous radiation dosage to the target at different distances. Finally, the half-value layers were measured for different X-ray fields to verify beam qualities by using an ion chamber. Results and Discussion: Beam alignment was performed in three steps, and collimators and other components were arranged to maintain the uniformity of the mean air kerma rate within ${\pm}2.5%$ at the effective beam diameter of 28 cm. The beam quality was verified by using half-value layer measurement methods specified by American National Standard Institute (ANSI) N13.11-2009 and International Organization for Standardization (ISO)-4037. For each of the nine beams than can be generated by the new X-ray irradiation system, air kerma rates for X-ray fields of different beam qualifies were measured. The results showed that each air kerma rate and homogeneity coefficient of the first and second half-value layers were within ${\pm}5%$ of the recommended values in the standard documents. Conclusion: The results showed that the new X-ray irradiation system provides beam qualities that are as high as moderate beam qualities offered by National Institute of Standards and Technology in ANSI N13.11-2009 and those for narrow-spectrum series of ISO-4037.

Wear and Implantation Tilt Measurements using X-ray and CAD (X-ray영상과 CAD를 이용한 인공고관절의 마모 및 식립각 측정법)

  • Lee, Jong Min;Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.107-114
    • /
    • 2018
  • Long-term complications such as loosening, wear, osteolytic lesion and granulomatous reaction by foreign bodies can occur, after total hip arthroplasty. The implantation alignment effects dislocation and wear, according to its amount and direction. Wear particles in total hip arthroplasty brings about biochemical complications such as osteolysis or send wear. In this sense, it is important to regularly check wear and alignment of total hip replacement. Because the wear in followup of 10 years may remain in a small amount, like a 1 or 2 mm generally, somewhat precise measurement tool has to be established. The wear and alignment measurement softwares commercially available currently lack in project saving or reproducibility. This study suggests a reliable method for the measurement using an X-ray image and a CAD software. The proposed method can be executed only if having a CAD software under most of current general clinical radiographical environment. The proposed was revealed through tests for the method to have accuracy of 0.06 mm with precision of 0.05 mm for wear measurement, and precision of 0.27 degrees for tilt measurement.

The MTF Measurement of the Conventional X-ray System by using the Computed Radiography (CR을 이용한 일반촬영장치의 MTF 측정)

  • Kim, Chang-Bok
    • Journal of radiological science and technology
    • /
    • v.28 no.2
    • /
    • pp.111-115
    • /
    • 2005
  • The quality of image from the system that creates medical images by using X-ray depends on the various different reasons such as the X-ray generator, the subject and the image transmission medium. In other words, thereare various factors existing that can influence on the quality of image from the moment when the X-ray is generated and until the final image is created. Therefore, the operator who creates images at the clinical site should make continuous evaluation and observation from the final image. There are various methods of evaluating the medical images, but it is assumed that the MTF measurement method can be suitable for measuring actual or effective resolution. So in this study, the MTF measurement method by using X-ray film has been avoided and the MTF features according to the deterioration of the X-ray system have been measured by using the software (the program used Borland C++ builder software and LEAD tools software) that can measure the MTF of the digital medical images. As the result of this measurement, it has been found out through the MTF graph that the resolution and sharpness from the old x-ray generator with a many years of using and many numbers of times of using were deteriorated for the quality of image comparing to those from the new system. Also a simple and easy measurement method for the MTF from the digital medical images can be obtained in this study.

  • PDF

Analysis of Space Radiation Dose Rate using portable X-ray Generating Device for Abdomen (이동형 X-ray 발생장치를 이용한 복부 촬영 시 공간 선량률에 관한 연구)

  • Park, Chang-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.97-101
    • /
    • 2010
  • This experimental study is carried out one of the General Hospital in Kyungbok providence. Abdomen Phantom being located Anterior-posterior(AP) position on portable bed, and the portable X-ray generating device was placed the phantom at $-90^{\circ}$ direction. The experiment were set 65 kVp, 10 mAs, $10{\times}10\;cm^2$, 100 cm(FOD) for the measurement. Digital proportional counting tube survey meter was used for measuring the space scatter dose. Measurement points of horizontal distribution was set up at $30^{\circ}$ interval by increasing 50 cm radius of upside, downside, left and right. Vertical distribution of measurement points were set up for the vertical plane with a radius of at $30^{\circ}$ intervals with 50cm increments. It is concluded that longer distance from the soure of X-ray significantly decrease radiation dose to the patient and use of the radiation protection device should be applied in clinical practice to reduce dose to the patient.

  • PDF

Flow Measurement in Xylem Vessels of a Bamboo Leaf Using Synchrotron X-ray Micro Imaging (Synchrotron X-ray 미세영상기법을 이용한 식물 목질부 내부 수액 유동의 계측)

  • Kim Yang Min;Lee Sang-Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.83-86
    • /
    • 2003
  • Synchrotron X-ray micro imaging technique was employed to non-invasively monitor the water flow inside xylem vessels in a bamboo leaf. The phase contrast X-ray images clearly visualized plant anatomy and the rise of a water front inside the vessels. Consecutive X-ray images taken for 60 seconds revealed water rise kinetics against gravity in the xylem of a cut dry leaf taken from a bamboo tree. For the first time, traces of water rise, variation of contact angle between water and xylem wall as well as the internal structure of xylem were obtained. In xylem vessels, a repeating flow pattern has a typical flow velocity of $30.7{\mu}m/s$ and faster flow is established intermittently. It is concluded that the transmission type of X-ray micro imaging can be used as a powerful tool to investigate the ascent of sap in the xylem vessels at a resolution higher than that of MRI.

  • PDF

Development of Neutron, Gamma ray, X-ray Radiation Measurement and Integrated Control System (중성자, 감마선, 엑스선 방사선 측정 및 통합 제어 시스템 개발)

  • Ko, Tae-Young;Lee, Joo-Hyun;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.21 no.4
    • /
    • pp.408-411
    • /
    • 2017
  • In this paper, we propose an integrated control system that measures neutrons, gamma ray, and x-ray. The proposed system is able to monitor and control the data measured and analyzed on the remote or network, and can monitor and control the status of each part of the system remotely without remote control. The proposed system consists of a gamma ray/x-ray sensor part, a neutron sensor part, a main control embedded system part, a dedicated display device and GUI part, and a remote UI part. The gamma ray/x-ray sensor part measures gamma ray and x-ray of low level by using NaI(Tl) scintillation detector. The neutron sensor part measures neutrons using Proportional Counter Detector(low-level neutron) and Ion Chamber Type Detector(high-level neutron). The main control embedded system part detects radiation, samples it in seconds, and converts it into radiation dose for accumulated pulse and current values. The dedicated display device and the GUI part output the radiation measurement result and the converted radiation amount and radiation amount measurement value and provide the user with the control condition setting and the calibration function for the detection part. The remote UI unit collects and stores the measured values and transmits them to the remote monitoring system. In order to evaluate the performance of the proposed system, the measurement uncertainty of the neutron detector was measured to less than ${\pm}8.2%$ and the gamma ray and x-ray detector had the uncertainty of less than 7.5%. It was confirmed that the normal operation was not less than ${\pm}15$ percent of the international standard.

Spatial Dose Distribution from Portable Hand-Held Dental X-Ray Equipment (이동형 치과 X선 발생장치의 공간선량 분포)

  • Han, Gyeong-Soon;Ahn, Sung-Min
    • Journal of dental hygiene science
    • /
    • v.15 no.3
    • /
    • pp.254-258
    • /
    • 2015
  • To compare the stationary dental X-ray generator and the portable dental X-ray generator and to understand spatial radiation dose depended on locations by measuring spatial radiation dose of the portable dental X-ray generator. The researchers used an Ionization chamber to measure spatial radiation dose which was generated while applying X-ray radiation to real bone skull phantom with both portable and stationary dental X-ray generator. There were 4 measurement locations which were immediate anterior, right, left and posterior. Distance of measurement was 50 cm in every location and the recorded result is an average of two applications of X-ray radiation to the maxillary molar area under the condition of 70 kVp, 3 mA, 0.1 sec. Average spatial radiation dose of portable X-ray generator was $37.51{\mu}Sv$, much higher than that of stationary X-ray generator which was $10.77{\mu}Sv$ (p<0.001). The result of the spatial radiation dose of the portable X-ray generator showed a huge difference depending on types of units which varied from $17.77{\mu}Sv$ to $68.90{\mu}Sv$ (p<0.05), also depending on the measurement location, immediate anterior resulted in the highest radiation dose of $54.14{\mu}Sv$ and immediate right was the lowest of $13.60{\mu}Sv$. Immediate left and posterior, however, resulted in similar radiation dose which were $42.12{\mu}Sv$, $40.18{\mu}Sv$ (p<0.01). With this result, we claim that usage of portable dental X-ray generator should be restricted to patients who can't move and exposure to radiation should be minimized by wearing lead-apron.