• Title/Summary/Keyword: X-ray measurement

Search Result 1,305, Processing Time 0.043 seconds

Binding energy study from photocurrent signal in HgCdTe layers

  • Hong, Kwang-Joon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.379-379
    • /
    • 2010
  • $Hg_{1_x}Cd_xTe$ (MCT) was grown by hot wall epitaxy. Prior to the MCT growth, the CdTe (111) buffer layer was grown on the GaAs substrate at the temperature of $590^{\circ}C$ for 15 min. When the thickness of the CdTe buffer layer was $5\;{\mu}m$ or thicker, the full width at half maximum values obtained from the x-ray rocking curves were found to significantly decrease. After a good quality CdTe buffer layer was grown, the MCT epilayers were grown on the CdTe (111) /GaAs substrate at various temperatures in situ. The crystal quality for those epilayers was investigated by means of the x-ray rocking curves and the photocurrent experiment. The photoconductor characterization for the epilayers was also measured. The energy band gap of MCT was determined from the photocurrent measurement and the x composition rates from the temperature dependence of the energy band gap were turned out.

  • PDF

Assessment of DVC measurement uncertainty on GFRPs with various fiber architectures

  • Bartulovic, Ante;Tomicevic, Zvonimir;Bubalo, Ante;Hild, Francois
    • Coupled systems mechanics
    • /
    • v.11 no.1
    • /
    • pp.15-32
    • /
    • 2022
  • The comprehensive understanding of the fiber reinforced polymer behavior requires the use of advanced non-destructive testing methods due to its heterogeneous microstructure and anisotropic mechanical proprieties. In addition, the material response under load is strongly associated with manufacturing defects (e.g., voids, inclusions, fiber misalignment, debonds, improper cure and delamination). Such imperfections and microstructures induce various damage mechanisms arising at different scales before macrocracks are formed. The origin of damage phenomena can only be fully understood with the access to underlying microstructural features. This makes X-ray Computed Tomography an appropriate imaging tool to capture changes in the bulk of fibrous materials. Moreover, Digital Volume Correlation (DVC) can be used to measure kinematic fields induced by various loading histories. The correlation technique relies on image contrast induced by microstructures. Fibrous composites can be reinforced by different fiber architectures that may lead to poor natural contrast. Hence, a priori analyses need to be performed to assess the corresponding DVC measurement uncertainties. This study aimed to evaluate measurement resolutions of global and regularized DVC for glass fiber reinforced polymers with different fiber architectures. The measurement uncertainties were evaluated with respect to element size and regularization lengths. Even though FE-based DVC could not reach the recommended displacement uncertainty with low spatial resolution, regularized DVC enabled for the use of fine meshes when applying appropriate regularization.

The Anode Heel Effect caused by changing the Angle of X-Ray Tube (X-선관 각도 변경에 따른 Anode Heel Effect)

  • Shin, Seong-gyu;Lee, Hyo-Yeong
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.6
    • /
    • pp.435-442
    • /
    • 2016
  • This study was an investigation of the anode heel effect caused by changing the angle of the x-ray tube. We established the following conditions for experimental measurements: 70 kV, 30 mAs, focus-detector distance of 100cm, and a collimator setting of $35{\times}43cm^2$. The measurement points were set up at the center of the collimator and extended to each side in intervals of 3.5cm, with points A1, A2, A3, A4, A5, A6 on the anode side and points C1, C2, C3, C4, C5, C6 on the cathode side. We measured the entrance surface dose from point A6 to point C6 with each point perpendicular to an x-ray tube. And we did the same when measuring different angles of the x-ray tube from 15 to 30 degrees for every point on the anode and cathode sides. Using perpendicular x-ray tube, we found that the entrance surface dose of the A5 point was three times higher than that of the C5 point. Thus, we conclude that if the anode side is placed near highly radiosensitive organs, then there will be less radiation exposure when using a perpendicular x-ray tube. When imaging using x-ray tube angles, an angle to the cathode side can reduce the gap of the entrance surface dose on both the anode and cathode sides. When imaging areas where there are differences in thickness between the upper and lower sides, the angle to the cathode side that is closer to the thicker area can reduce the gap of the entrance surface dose and capture a higher quality image.

On the Graphitic Properties of Korean Anthracite (II) X-ray Diffraction Method as an Estimation of the Graphitic Properties of Anthracite (石炭의 黑鉛性에 關한 硏究 (第2報))

  • Sin Sup Oh;Suk Won Lee;Changmoo Lee
    • Journal of the Korean Chemical Society
    • /
    • v.7 no.2
    • /
    • pp.182-185
    • /
    • 1963
  • In the previous paper of the series of researches on the graphitic properties of anthracites, authors have already reported the results on the electrical specific resistance measurements for Korean anthracites in order to develope a simple methods which differentiate graphite from anthracite. In this paper, the X-ray diffraction method and oxidation have been applied and compared with the results which were obtained by the specific resistance measurements in the previous paper. It has been confirmed that there is a parallel relation between the value of specific resistance measurement and height of hexagonal peak by X-ray diffraction, but the color reaction due to graphitic acid by oxidation does not show any definite critical points between graphite and anthracite.

  • PDF

Characterization of Two-Dimensional Transition Metal Dichalcogenides in the Scanning Electron Microscope Using Energy Dispersive X-ray Spectrometry, Electron Backscatter Diffraction, and Atomic Force Microscopy

  • Lang, Christian;Hiscock, Matthew;Larsen, Kim;Moffat, Jonathan;Sundaram, Ravi
    • Applied Microscopy
    • /
    • v.45 no.3
    • /
    • pp.131-134
    • /
    • 2015
  • Here we show how by processing energy dispersive X-ray spectrometry (EDS) data obtained using highly sensitive, new generation EDS detectors in the AZtec LayerProbe software we can obtain data of sufficiently high quality to non-destructively measure the number of layers in two-dimensional (2D) $MoS_2$ and $MoS_2/WSe_2$ and thereby enable the characterization of working devices based on 2D materials. We compare the thickness measurements with EDS to results from atomic force microscopy measurements. We also show how we can use electron backscatter diffraction (EBSD) to address fabrication challenges of 2D materials. Results from EBSD analysis of individual flakes of exfoliated $MoS_2$ obtained using the Nordlys Nano detector are shown to aid a better understanding of the exfoliation process which is still widely used to produce 2D materials for research purposes.

Measurement of the group-delay dispersion of optical elements using white-light interferometry (백색광 간섭계를 이용한 광학소자의 군지연분산 측정)

  • Tayyab Imran;Hong, Kyung-Han;Yu, Tae-Jun;Nam, Chang-Hee
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.07a
    • /
    • pp.248-249
    • /
    • 2003
  • The characterization of laser mirrors is important for obtaining proper performance of femtosecond lasers. Characteristics of laser mirrors are usually described in terms of their reflectivity at a certain wavelength. In femtosecond laser applications, however, the dispersion property of the mirror should be considered because the temporal shape of a femtosecond light pulse changes during the reflection at the mirrors. (omitted)

  • PDF

Radiographic Study of Cobey Method and Modified Cobey Method (Cobey 검사법과 Modified Cobey 검사법에 대한 방사선학적 연구)

  • Go, Yu-Rim;Joo, Young-Cheol;Lee, Seung-Keun
    • Journal of radiological science and technology
    • /
    • v.42 no.3
    • /
    • pp.167-173
    • /
    • 2019
  • The Cobey method and the modified Cobey method are most commonly used in clinical practice. Therefore, the purpose of this study was to investigate the radiological differences between Cobey and modified Cobey and provide radiographic information about changes of hindfoot image with X-ray entrance center and tube angle change in modified Cobey. This study was performed on foot and ankle phantom. First, for image comparison of Cobey and modified Cobey, the images obtained by applying the same X-ray entrance center to the ankle joint were compared and analyzed. Second, in the modified Cobey, the X-ray entrance center is set as ankle joint and lateral malleolus. The X-ray tube angle was varied from $10^{\circ}$ to $40^{\circ}$ at $5^{\circ}$ intervals for each X-ray entrance center. The images obtained by varying the X-ray tube angle from $10^{\circ}$ to $40^{\circ}$ at intervals of $5^{\circ}$ for each X-ray entrance center were compared and analyzed. The irradiation conditions were the same with 110 kVp, 200 mA, 10 ms, and 110 cm of source - image receptor distance (SID). Image evaluation was performed by two radiologists. Measurements were made on the lateral point, middle point, and calcaneus width based on a hypothetical line parallel to the calcaneal tuberosity. Data were analyzed by using descriptive statistics as the mean of the distance to each measurement location. The modified Cobey was longer than the Cobey by an average of 3 to 4 mm lateral and medial points, and the calcaneus width was similar (ICC = 0.939). In modified Cobey method, when the X-ray entrance center is ankle joint, the lateral point is about 3 mm and the medial point is about 4.3 mm longer than lateral malleolus. Also, when the X-ray tube angle is more than $20^{\circ}$, the degree of distortion is large. The ICCs for the lateral, medial point, and calcaneus width were 0.998, 0.961, and 0.997, respectively, as the X-ray entrance center and tube angle were changed. There was no significant difference between Modified Cobey and Cobey. Modified Cobey showed no need to compensate the $20^{\circ}$ detector angle of the Cobey. In addition, we suggest that tube angle should be limited within $20^{\circ}$ when modified Cobey is performed.

Improvement of Measurement Accuracy by Correcting Systematic Error Associated with the X-ray Diffractometer (X-선 회절 장비의 기계적 오차 수정을 통한 분석 정확도 향상)

  • Choi, Dooho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.97-101
    • /
    • 2017
  • X-ray diffractometers are used to characterize material properties, such as the phase, texture, lattice constant and residual stress, based on the diffracted beams obtained from specimens. Quantitative analyses using X-rays are typically conducted by measuring the peak positions of the diffracted beams. However, the long-term use of the diffractomer, like any other machine, results in errors associated with the mechanical parts, which can deteriorate the accuracy of the quantitative analyses. In this study, the process of correcting systematic errors in the $2{\theta}$ range of $30{\sim}90^{\circ}$ is discussed, for which strain-free Si powders from NIST were used as the standard specimens. For the evaluation of the impact of such error correction, we conducted a quantitative analysis of the true lattice constant for tungsten thin films.

A Study on the Performance Evaluation of Portable Radiation Shielding Apparatus (이동형 방사선 차폐장치의 성능평가에 관한 연구)

  • Koo, Bon-Yeoul;Han, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.41 no.4
    • /
    • pp.289-295
    • /
    • 2018
  • When using a mobile X-ray unit, primary radiation creates medical images and secondary radiation scatters in many directions, which reduces image quality and causes exposure to patients, care givers and medical personnel. The purpose of this study was to develop a radiation shielding system for effectively shielding secondary radiation and evaluate its effectiveness. Using a mobile X-ray unit, spatial dose according to presence of human equivalent phantom and spatial dose using the developed shielding device were measured, and the phantom at 80 cm equidistance from center of X-ray was compared with spatial dose according to use of a shield. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from the head direction($-90^{\circ}$) to the body direction($+90^{\circ}$). In the spatial dose measurement with and without the phantom, when the human equivalent Phantom was used, the spatial dose was increased by 40% in all directions from 40 cm to 100 cm from the central X-ray, and about 88% of the space dose was reduced when using the developed shields with the phantom. The equidistance dose at 80 cm from the central X-ray was increased by 39% from $5.1{\pm}0.26{\mu}Gy$ to $7.1{\pm}0.15{\mu}Gy$ when the human equivalent phantom was used, and when phantom was used and shielding was used, the spatial dose was reduced by about 90% from $7.1{\pm}0.15{\mu}Gy$ to $0.7{\pm}0.07{\mu}Gy$. The spatial dose of natural radiation was measured to be about $0.2{\pm}0.04{\mu}Gy$ when using the developed shielding with Phantom at a distance of 1 m or more. It is expected that by using the developed shielding system, it will be possible to effectively reduce secondary radiation dose received in all directions and to ensure safe imaging.

Study on the Exposure Field of Head and Neck with Measurement of X-ray dose Distribution for Dental Panoramic X-ray System (치과 파노라마 장치의 X선 공간선량분포 측정을 통한 두경부 피폭영역 조사에 대한 연구)

  • Oh, Yoonjin;Hong, Girang;Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.17-21
    • /
    • 2015
  • Recently, As people's interest in the health of teeth is increased in the medical field changed into aging society, the number of times for the radiological diagnosis is increased. It can be said that the radiation exposure dose of Korean population is increased. It is also growing concern about radiation exposure. Therefore, the basic data for the dental panoramic X-ray system, its investigation and measuring the radiation dose is needed. In this study, we used ALOKA PDM-117 dosimeter and estimated a two-dimensional dose distribution of the dental panoramic X-ray system (VATEC Pax-400). Dose evaluation about the distribution is confirmed from the point of radiation exposure of a patient. Dose distribution of the dental panoramic X-ray system irradiated chin and the facial region to high dose as well as the parts of teeth. It was founded that the eye lens which are sensitive to radiation are exposed to unnecessary radiation, considering the effect of scattered radiation. The results of this study will be used more accurate dose assessment in a variety of object size and location of measuring dose.