• Title/Summary/Keyword: X-ray inspection

Search Result 214, Processing Time 0.021 seconds

General Radiography Examination Statistical analysis of Patients in Geriatric hospitals (노인요양병원 내원환자의 일반촬영 통계분석)

  • Kim, Kyuhyung;Lee, Junhang;Kim, Youngwan
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.71-79
    • /
    • 2013
  • The purpose of this study is to establish the basic data for the management of the elderly patients aged more than 60 suffering from musculoskeletal disorders in geriatric hospitals. From January, 1 2012 to December 31, 2012, 2,500 patients who were taken the x-ray inspection and were analyzed x-ray order 5,042 cases above spines, upper lower extremities and joints. The elderly age was divided into 3 groups according to Brody elderly statistics. The majority of elderly patients who visited the hospital are exposed to spinal disorders and joint diseases. Shoulder, knee, L-spine examination cases had accounted for more than half the number of total. By age group, the number of the first quarter was most dominant commonly. Second and third quarter was maintaining slightly decrease. The fourth quarter had reduced compared to the first quarter. If the visiting purposes and the disease causes analysis and preventive measures are taken in a study, it is expected to utilize as basic data to make a plan of the education for preventing diseases and elderly behavior planning for geriatric hospitals and to redistribute health care resources of the rural areas efficiently.

The Clinical Study of Biyun(sinusitis) in Children (소아비연(小兒鼻淵)에 대(對)한 임상적(臨床的) 연구(硏究))

  • Park Eun-Jeong;Lee Hae-Ja
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.12 no.1
    • /
    • pp.111-131
    • /
    • 1998
  • 1. In oriental medicine, the case of sinusitis can be explained, not only external invasion such as PUNG HAN(wind-cold), PUNG YUL(wind-hot), SHUP YUL(damp-heat), but also functional disorder of internal organ such as spleen(脾), lung(肺), kidney(腎) The western medicine classified the cause of sinusitis as two factors. That is bacterial infection factor-Haemophilus influenza, streptococcus pyogeues, streptococcus pneumonia- and viral infection factor-Rhinovirus, parainfluenza, Echo28, Coxsacki21, Sinusitis is complicated to allergic rhinitis, chronic otitis media purulent, chronic tonsilitis, sinubronchitis. On the condition of nasal septum deformity, turbinates deformity, nasal septum deviation, sinusitis can be developed. the predisposing factors of sinusitis is swimming, air pollution, malnutrition, shortage of immunity.2. According to survey, sinusitis occurred that children from 4 to 12 years old and from 5 to 7 years old occupied 70% 3. From the past history data, they experienced chronic tonsillar hypertropy(20%), otitis media, atopic dermatitis, allergic rhinitis, bronchial asthma, pneumonia, bronchiolitis, chronic sore throat, urticaria, milk allergy in sequence. 4. the symptoms of sinusitis is nasal obstruction, postnasal dripping, purulunt(yellow)or white discharge, cough, nose bleeding in sequence. nasal obstruction take the portion of 95%, postnasal dripping 65%, night time or early morning cough 60%. 5. The suffering period of sinusitis is 6 month minimum, 4 years maximum, most cases are included in a year. The suffering period of children was shorter than adult. 6. Diagnosis depend on inspection of nasal cavity, postnasal dripping, X-ray finding. 75% of patient(15case) showed both maxillary sinusitis, 25%(5cases) showed left or right maxillary sinusitis. 7. Treatment of oriental medicine, consist of Herb-medicine, acupuncture and exposing of Lazer beam. Kamihyunggyeyungyotang(加味荊芥蓮翹湯) is administered mainly as the medical therapy, Kamigwaghyangjeungkisan(加味藿香正氣散) Kimizwakwieum(加味左歸飮), Kamihyangsosan(加味香蘇散) is administered for a additional symptoms which occurred by influenza recurrence. Kamijeonxibackchulsan(加味錢氏白朮散) is administered to treat gastro-intestine trouble patients who have sinusitis. 8. The period of treatment is varied with patient conditions and X-ray finding. The minimal period is 35days, maximal period is 202days. So it took about 86days in average and about 50% of patient(10cases) is recovered in one or two month.

  • PDF

Evaluation of Virtual Grid Software (VGS) Image Quality for Variation of kVp and mAs (관전압과 관전류량 변화에 대한 가상 그리드 소프트웨어(VGS) 화질평가)

  • Chang-gi Kong
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.725-733
    • /
    • 2023
  • The purpose of this study is to evaluate the effectiveness of virtual grid software (VGS). The purpose of this study is to evaluate the changes in energy and object thickness by dividing the use of VGS into two cases (Without-VGS) without using a movable grid. We attempted to determine the effectiveness of VGS by acquiring images using a chest phantom and a thigh phantom and analyzing SNR and CNR. In the chest phantom and femoral phantom, the tube flow was fixed at 2.5 mAs, and the tube voltage was changed by 10 kVp from 60 to 100 kVp to measure SNR and CNR, and SNR was about 1.09 to 8.86% higher in the chest phantom than in Without-VGS, and CNR was 4.18 to 14.56% higher in the VGS than in Without-VGS. And in the femoral phantom, SNR was about 9.78 to 18.05% higher in VGS than in Without-VGS, and CNR was 21.07 to 44.44% higher in VGS than in Without-VGS. The tube voltage was fixed at 70 kVp in the chest phantom and the femoral phantom, and the amount of tube current was changed at 2.5 to 16 mAs, respectively, and after X-ray irradiation, SNR and CNR were measured in the chest phantom, which was about 1.49 to 11.11% higher in VGS than in Without-VGS, and CNR was 4.76 to 13.40% higher in VGS than in Without-VGS. And in the femoral phantom, SNR was about 2.22 to 17.38% higher in VGS than in Without-VGS, and CNR was 13.85 to 40.46% higher in VGS than in Without-VGS. Therefore, if an inspection is required with a mobile X-ray imaging device, it is believed that good image quality can be obtained by using VGS in an environment where it is difficult to use a mobile grid, and it is believed that the use of mobile X-ray devices can be increased.

A Study on the Bonding Residual Thermal Stress Analysis of Dissimilar Materials Using Boundary Element Method (경계요소법에 의한 이종재료 접합 잔류열응력의 해석)

  • Yi, Won;Yu, Yeong-Chul;Jeong, Eui-Seob;Yun, In-Sik
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.15 no.4
    • /
    • pp.540-548
    • /
    • 1996
  • In general residual stress is measured by X-ray diffraction method but in case of bonding residual thermal stress it is inadequate technique to examine the stress singularity. Therefore Two-dimensional elastic boundary element analyses were carried out to investigate the residual thermal stress and stress singularity of bonding interface in Al/Epoxy. This boundary element results were compared with the strain gauge measurements. The effects of different interface models, sub-element and adherend thickness are presented and discussed. On the basis of the obtained results, interface delamination causing by normal stress is expected and stress singularity is observed more intensively increasing with adherend thickness. It is concluded that the bonding strength of Al/Epoxy interface can be estimated correctly by taking into account the stress singularity at the edge of the interface.

  • PDF

Quality assurance algorithm using fuzzy reasoning for resistance spot weldings (퍼지추론을 이용한 저항 점용접부위의 품질평가 알고리듬)

  • Kim, Joo-Seok;Lee, Jae-Ik;Lee, Sang-ryong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.3
    • /
    • pp.644-653
    • /
    • 1998
  • In resistance spot weld, the assurance of weld quality has been a long-standing problem. Since the weld nuggets if resustance spot welding form between the workpieces, visual detection of defects in usually impossible. Welding quality of resistance spot welding can be verified by non destructive and destructive inspections such as X-Ray inspection and testing of weld strength. But these tests, in addition to being time-consuming and costly, can entail risks due to sampling basis. The purpose of this study is the development of the monitoring system based on fuzzy inference, aimed at diagonosis of quality in resistance spot welding. The fuzzy inference system consists of fuzzy input variables, fuzzy membership functions and fuzzy rules. For inferring the welding quality(strength), the experimental data of the spot welding were acquired in various welding conditions with the monitoring system designed. Some fuzzy input variables-maximum, slop and difference values of electrode movement signals-were extracted from the experimental data. It was confirmed that the fuzzy inference values of strength have a .${\pm}$5% error in comparison with actual values for the selected welding conditions(9-10.5KA, 10-14 cycle, 250-300 $kg_f$). This monitoring system can be useful in improving the quality assurance and reliability of the resistance spot welding process.

Evaluation of Usability and Radiation Dose Measurement Using Personal Radiation Exposure Dosimeter (방사선 개인피폭선량계를 이용한 피폭선량 측정 및 유용성 평가)

  • Kang, In-Seog;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.11
    • /
    • pp.864-870
    • /
    • 2014
  • To propose a basis for the selection of personal dosimeters to measure radiation dose administration of radiation workers as a way to evaluate the usefulness dosimeter. For the dosimetry of the radiation workers 2012, during 1 year, 30 were radiation workers to measure personal dose. By personal exposure is measured cumulative dose, is investigated the performance of the TLD, PLD, OSLD. And comparing the measured value of each dosimeter dose and analyzed. Medical institutions, inspection work and quarterly confirmed the cumulative exposure dose of radiation workers. Using DAP and Ion-Chamber, to measure to compare TLD, PLD, OSLD dosimeter performance. A comparison of the directly through the X-ray dosimeter and The absolute value of the Ion-Chamber, OSLD more similar than in the TLD and PLD showed the dose values so the excellent ability to measure the results. Also in radiation generating area dose of radiation workers is higher than that in OSLD. Consequently, in terms of the individual exposure management OSLD is appropriated and beneficial than others.

A Novel Al-Bridged Trinuclear Iron(II) Bis(imino)pyridyl Complex with Catalytic Ethylene Polymerization Behavior

  • Long, Zerong;Li, Zhongquan;Ma, Ning;Wu, Biao
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.8
    • /
    • pp.2537-2543
    • /
    • 2011
  • A self-assembled Al-bridged diiminopyridine-based ligand (3) was synthesized and characterized by FT-IR, ESI-MS and NMR spectroscopy. Electron spectral titrations were performed to confirm the formation of a novel trinuclear bis(imino)pyridyl iron(II) complex (4) upon addition of $FeCl_2$ into Al-bridged ligand 3 in methanol solution. Simultaneously, a typical bis(imino)pyridine-iron(II) complex (2) was synthesized and fully characterized. The X-ray crystal study of the iron(II) complex 2 disclosed a five-coordinate, distorted square-pyramidal structure with the tridentate N^N^N ligand and chlorides. The optimal molecular structure of 4 was obtained by means of molecular mechanics, which showed that each iron atom in the complex 4 is surrounded by two chlorides, a tridentate N^N^N ligand and one oxygen atom, supporting considerations about the possibility of six-coordinate geometry from MMAO or the ethylene access. A comparison of 4 with the reference 2 revealed a remarkable decrease of the catalytic activity and MMAO consumption (activity up to $0.41{\times}10^3\;kg\;{mol_{Fe}}^{-1}h^{-1}bar^{-1}$, Al/Fe = 650 for 4 and $7.02{\times}10^3\;kg\;{mol_{Fe}}^{-1}h^{-1}bar^{-1}$, Al/Fe = 1600 for 2).

A Case Study of Concrete Pavement Deterioration by Alkali-Silica Reaction in Korea

  • Hong, Seung-Ho;Han, Seung-Hwan;Yun, Kyong-Ku
    • International Journal of Concrete Structures and Materials
    • /
    • v.1 no.1
    • /
    • pp.75-81
    • /
    • 2007
  • The concrete pavement of the Seohae Highway in Korea has suffered from serious distress, only four to seven years after construction. Deterioration due to Alkali-Silica Reaction (ASR) has seldom been reported per se in Korea, because the aggregate used for the cement concrete has been considered safe against alkali-silica reaction so far. The purpose of this study is to examine the deterioration caused by an alkali-silica reaction of concrete pavement in Korea. The investigation methods included visual inspection and Automatic Road Analyzer (ARAN) analysis of surface cracks, coring for internal cracks, stereo microscopic analysis, scanning electronic microscope (SEM) analysis, and electron dispersive X-ray spectrometer (EDX) analysis. The results are presented as follows: the crack pattern of the concrete pavement in Korea was longitudinal cracking, map cracking or D-cracking. Local areas of damage were noticed four to five years after construction. The cracks started from edges or joints and spread out to slabs. The most intensive cracking was observed at the intersection of the transverse and longitudinal joints. Where cracking was the most intense, pieces of concrete and aggregate had spalled away from top surface and joint interface area. The progress of deterioration was very fast. The reaction product of alkali-silica gel was clearly identified by its generally colorless, white, or very pale yellow hue seen through a stereo optical microscopy. The typical locations of the reaction product were at the interface between aggregate and cement paste in a shape of a rim, within aggregate particles in the cracks, and in the large void in the cement paste. Most of the white products were found at interface or internal aggregates. SEM and EDX analysis confirmed that the white gel was a typical reaction product of ASR. The ASR gel in Korea mainly consisted of Silicate (Si) and Potassium (K) from the cement. The crack in the concrete pavement was caused by ASR. It seems that Korea is no longer safe from alkali-silica reaction.

Physicochemical Characteristics of Starches in Rice Cultivars of Diverse Amylose Contents

  • Yoon, Mi-Ra;Chun, A-Reum;Oh, Sea-Kwan;Hong, Ha-Cheol;Choi, Im-Soo;Lee, Jeong-Heui;Cho, Young-Chan;Kim, Yeon-Gyu
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.57 no.3
    • /
    • pp.226-232
    • /
    • 2012
  • Through the sampling four rice cultivars with differing amylose contents, the relationship between the structural and gelatinization properties of endosperm starches was analyzed. These rice varieties exhibited different chain length distribution ratio within the amylopectin cluster as well as varing amylose levels. The proportion of amylopectin short chains of in Goami cutlivars was higher than the other varieties, whereas the Goami 2 which shows amylose extender mutant properties in the endosperm showed the highest proportion of long chains. In X-ray diffraction analysis of rice starches, the Goami 2 variety displayed a B-type pattern whereas the other varieties were all A-type. Among the cultivars with high and normal rice starch levels, those with the higher amylose contents showed distinctly lower swelling. Goami 2 rice was found to have the highest onset and peak gelatinization temperature from the differential scanning calorimetry results. The four rice cultivars under analysis also showed different rates of hydrolysis by amyloglucosidase. These findings suggest that the composition and chemical structure of the starch content is a major determinant of both the gelatinization and functional properties of rice.

Useful Corrosion - Potential of Magnesium Alloys as Implants

  • Kaya, A. Arslan;Kaya, R. Alper;Witte, Frank;Duygulu, Ozgur
    • Corrosion Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.162-167
    • /
    • 2008
  • Degradable implants have been in use for bone surgery for decades. However, degradable metal implants are one of the new research areas of biomaterials science. Magnesium has good biocompatibility due to its low toxicity, and it is a corroding, i.e. dissolvable, metal. Furthermore, magnesium is needed in human body, and naturally found in bone tissue. There have been some published reports also asserting the potential bone cell activation or bone healing effect of high magnesium ion concentrations. The classic method for achieving intertransverse process fusion involves autogenous iliac crest bone graft. Several investigations have been performed to enhance this type of autograft fusion. However, there is no research which has been undertaken to investigate the efficiency of pure magnesium particles in posterolateral spinal fusion. In this study, corrosion behavior of magnesium metal at the bone interface, the possibility of new bone cell formation and the degree of effectiveness in producing intertransverse process lumbar fusion in a sheep model have been investigated. Cortical bone screws were machined from magnesium alloy AZ31 extruded rod and implanted to hip-bones of sheep via surgery. Three months after surgery, the bone segments carrying these screws were removed from the sacrificed animals. Samples were sectioned to reveal Mg/bone interfaces and investigated using optical microscope, SEM-EDS and radiography. Optical and SEM images showed that there was a significant amount of corrosion on the magnesium screw. The elemental mapping results indicate, due to the presence of calcium and phosphorus elements, that there exists new bone formation at the interface. Furthermore, sixteen sheep were subjected to intertransverse process spinal fusions with pedicle screw fixation at various locations along their spines. Each animal was treated with 5cc autograft bone at one fusion level and 1cc magnesium+5cc autograft bone at the other. Six months after surgery, bone formation was evaluated by gross inspection and palpation, and radiological, histological, scanning electron microscopic and x-ray diffraction analyses. It may be stated that the potential for using useful corrosion of magnesium alloys in medical applications is expected to be significant.