• Title/Summary/Keyword: X-ray inspection

Search Result 214, Processing Time 0.023 seconds

A Study on Stereo Visualization of the X-ray Scanned Image Based on Volume Reconstruction (볼륨기반 X-선 스캔영상의 3차원 형상화 연구)

  • Lee, Nam-Ho;Park, Soon-Yong;Hwang, Young-Gwan;Park, Jong-Won;Lim, Yong-Gon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.7
    • /
    • pp.1583-1590
    • /
    • 2011
  • As the existing radiation scanning systems use 2-dimensional radiation scanned images, the low accuracy has been pointed out as a problem of it. This research analyzes the applicability of the stereo image processing technique to X-ray scanned images. Two 2-dimensional radiation images which have different disparity values are acquired from a newly designed stereo image acquisition system which has one additional line sensor to the conventional system. Using a matching algorithm the 3D reconstruction process which find the correspondence between the images is progressed. As the radiation image is just a density information of the scanned object, the direct application of the general stereo image processing techniques to it is inefficient. To overcome this limitation of a stereo image processing in radiation area, we reconstruct 3-D shapes of the edges of the objects. Also, we proposed a new volume based 3D reconstruction algorithm. Experimental results show the proposed new volume based reconstruction technique can provide more efficient visualization for cargo inspection. The proposed technique can be used for such objects which CT or MRI cannot inspect due to restricted scan environment.

Evaluation of Dynamic X-ray Imaging Sensor and Detector Composing of Multiple In-Ga-Zn-O Thin Film Transistors in a Pixel (픽셀내 다수의 산화물 박막트랜지스터로 구성된 동영상 엑스레이 영상센서와 디텍터에 대한 평가)

  • Seung Ik Jun;Bong Goo Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.359-365
    • /
    • 2023
  • In order to satisfy the requirements of dynamic X-ray imaging with high frame rate and low image lag, minimizing parasitic capacitance in photodiode and overlapped electrodes in pixels is critically required. This study presents duoPIXTM dynamic X-ray imaging sensor composing of readout thin film transistor, reset thin film transistor and photodiode in a pixel. Furthermore, dynamic X-ray detector using duoPIXTM imaging sensor was manufactured and evaluated its X-ray imaging performances such as frame rate, sensitivity, noise, MTF and image lag. duoPIXTM dynamic X-ray detector has 150 × 150 mm2 imaging area, 73 um pixel pitch, 2048 × 2048 matrix resolution(4.2M pixels) and maximum 50 frames per second. By means of comparison with conventional dynamic X-ray detector, duoPIXTM dynamic X-ray detector showed overall better performances than conventional dynamic X-ray detector as shown in the previous study.

Pose Estimation of an Object from X-ray Images Based on Principal Axis Analysis

  • Roh, Young-Jun;Cho, Hyung-Suck
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.97.4-97
    • /
    • 2002
  • 1. Introduction Pose estimation of a three dimensional object has been studied in robot vision area, and it is needed in a number of industrial applications such as process monitoring and control, assembly and PCB inspection. In this research, we propose a new pose estimation method based on principal axes analysis. Here, it is assumed that the locations of x-ray source and the image plane are predetermined and the object geometry is known. To this end, we define a dispersion matrix of an object, which is a discrete form of inertia matrix of the object. It can be determined here from a set of x-ray images, at least three images are required. Then, the pose information is obtained fro...

  • PDF

Contrast Enhancement for Defects Extraction from Seel-tube X-ray Images (결함추출을 위한 강판튜브 엑스선 영상의 명암도 향상)

  • Hwang, Jung-Won;Hwang, Jae-Ho
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.361-362
    • /
    • 2007
  • We propose a contrast-controlled feature detection approach for steel radiograph image. X-ray images are low contrast, dark and high noise image. So, It is not simple to detect defects directly in automated radiography inspection system. Contrast enhancement, histogram equalization and median filter are the most frequently used techniques to enhance the X-ray images. In this paper, the adaptive control method based on contrast limited histogram equalization is compared with several histogram techniques. Through comparative analysis, CLAHE(contrast controlled adaptive histogram equalization) can enhance detection of defects better.

  • PDF

Inspection of electronic components using dual X-ray energy (이중 엑스선 에너지를 이용한 전자부품 검사)

  • Chon, Kwon Su;Seo, Seung Jun;Lim, Jae Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.5
    • /
    • pp.301-306
    • /
    • 2015
  • X-ray can be applied to obtain a projection image of an object. It is not easy to obtain an high quality image for the object composed of low and high density materials. For the object with large difference in density, it is possible to realize high contrast image using images of low and high tube voltages and image processing. The plastic and metalic parts of the electronic components can be imaged by the dual energy technique which use low and high tube voltages and by processing pixel-by-pixel using visual C++. The contrast-enhanced image can be used to detect and observe defects within the electronic components.

Inspection of Weld Bead using High Speed Laser Vision Sensor

  • Lee, H.;Ahn, S.;Sung, K.;Rhee, S.
    • International Journal of Korean Welding Society
    • /
    • v.3 no.2
    • /
    • pp.53-59
    • /
    • 2003
  • Visual inspection using laser vision sensor was proposed for fast and economic inspection and was verified experimentally. Welding is one of the most important manufacturing processes for automotive and electronics industries as well as heavy industries. The weld zone influences the reliability of the products. There are two kinds of weld inspection tests, destructive and non­destructive test. Even though the destructive test is much more reliable, the product should be destroyed, and hence the non­destructive test such as ultrasonic or X­ray test was used to overcome this problem. However, these tests are not used for real time inspection.

  • PDF

Calculation of Concrete Shielding Wall Thickness for 450 kVp X-ray Tube with MCNP Simulation and Result Comparison with Half Value Layer Method Calculation (MCNP 시뮬레이션을 통한 450 kVp 엑스레이 튜브의 콘크리트 차폐벽 두께 계산 및 반가층 방법을 이용한 계산과의 결과 비교)

  • Lee, Sangheon;Hur, SamSurk;Lee, Eunjoong;Kim, Chankyu;Cho, Gyu-seong
    • Journal of Radiation Industry
    • /
    • v.10 no.1
    • /
    • pp.29-35
    • /
    • 2016
  • Radiation generating devices must be properly shielded for their safe application. Although institutes such as US National Bureau of Standards and National Council on Radiation Protection and Measurements (NCRP) have provided guidelines for shielding X-ray tube of various purposes, industry people tend to rely on 'Half Value Layer (HVL) method' which requires relatively simple calculation compared to the case of those guidelines. The method is based on the fact that the intensity, dose, and air kerma of narrow beam incident on shielding wall decreases by about half as the beam penetrates the HVL thickness of the wall. One can adjust shielding wall thickness to satisfy outside wall dose or air kerma requirements with this calculation. However, this may not always be the case because 1) The strict definition of HVL deals with only Intensity, 2) The situation is different when the beam is not 'narrow'; the beam quality inside the wall is distorted and related changes on outside wall dose or air kerma such as buildup effect occurs. Therefore, sometimes more careful research should be done in order to verify the effect of shielding specific radiation generating device. High energy X-ray tubes which is operated at the voltage above 400 kV that are used for 'heavy' nondestructive inspection is an example. People have less experience in running and shielding such device than in the case of widely-used low energy X-ray tubes operated at the voltage below 300 kV. In this study, Air Kerma value per week, outside concrete shielding wall of various thickness surrounding 450 kVp X-ray tube were calculated using MCNP simulation with the aid of Geometry Splitting method which is a famous Variance Reduction technique. The comparison between simulated result, HVL method result, and NCRP Report 147 safety goal $0.02mGy\;wk^{-1}$ on Air Kerma for the place where the public are free to pass showed that concrete wall of thickness 80 cm is needed to achieve the safety goal. Essentially same result was obtained from the application of HVL method except that it suggest the need of additional 5 cm concrete wall thickness. Therefore, employing the result from HVL method calculation as an conservative upper limit of concrete shielding wall thickness was found to be useful; It would be easy, economic, and reasonable way to set shielding wall thickness.

X-ray Computed Tomography on Larger Diameter Timber than Digital Detector

  • Kim, Chul-Ki;Lee, Jun-Jae;Oh, Jung-Kwon
    • Journal of the Korean Wood Science and Technology
    • /
    • v.41 no.5
    • /
    • pp.385-391
    • /
    • 2013
  • X-ray computed tomography is a very powerful nondestructive technique in safety inspection of historic timber building. But, in field, various testing condition makes it difficult to carry out X-ray CT testing. Limited size in X-ray digital detector is one of the problems. In this study, a pitch pine disk with two holes was used to know how imperfection in X-ray projection affects CT image resolution. Using various number of projections, CT image was reconstructed by filtered back projection method, and then it was investigated how many projection is required to identify the holes in different location. Two artificial holes could be differently detected according to their location in cross section of specimen. One hole in center part of specimen was identified using more than 9 radiographs, but the other one which located in outer part of cross section could not be detected until more than 36 projections were used. Even though there is data missing in outer part of cross section due to limited size of detector, the center part of CT image could be reconstructed well and the resolution of outer part became higher with increase of the number of projections. For field application, the number of projections for CT image reconstruction needs to be decided with consideration of another nondestructive testing and the location of interest.