• Title/Summary/Keyword: X-ray grid

검색결과 103건 처리시간 0.023초

흉부 X선사진 농도로부터 표면선량을 산출하는 방법 (The Relationship of Overdensity to Overexposure Each Film/screen Systems in Chest Radiography)

  • 김정민;허준;임태랑;석전유치;앵정달야
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권1호
    • /
    • pp.13-20
    • /
    • 1999
  • This study is to calculate the exposed radiation dose using Bit method, NDD calculation method and monogram method without dosimeter. In addition, we can calculate the radiation dose from x-ray film density as a film badge. The authors examined the entrance skin dose from $2{\sim}3$ intercostal chest x-ray film density. We also studied the relationship between film density and equivalent dose in the each screen film system under the different radiation quality and the poor geometry condition of grid ratio. As results, we established the deductive method to define the entrance skindose from chest x-ray film density. The error range was found in the range $-13%{\sim}+l7%$ for between deductive entrance skindose and the $2{\sim}3$ intercostal chest x-ray film density to actual detective radiation dose with dosimeter.

  • PDF

X-ray 영상에서 그리드 아티팩트 개선을 위한 동적 분할 기반 DCT 기법 (A Dynamically Segmented DCT Technique for Grid Artifact Suppression in X-ray Images)

  • 이지현;박준혁;서지수;김호준
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2018년도 추계학술발표대회
    • /
    • pp.813-816
    • /
    • 2018
  • X-ray 진단에서 그리드 하드웨어의 사용은 산란선에 의한 영상의 왜곡을 보정할 수 있는 장점이 있는 반면, 반복되는 라인 형태의 그리드 아티팩트를 발생시키는 부작용을 수반한다. 본 논문에서는 이러한 그리드 라인을 제거하는 방법론으로서 이산코사인변환(DCT: discrete cosine transform)을 사용 하는 기법을 제안한다. X-ray 영상에서 그리드 라인의 특성은 피사체의 형태와 영상의 영역에 따라 서로 다른 특성을 갖는다. 이에 본 연구에서는 동적으로 재구성되는 분할 구조를 기반으로 DCT 변환을 적용하고 개별 영역별로 필터전달함수를 최적화하는 방법을 채택하였다. 추출된 주파수 영역 데이터에 대하여 그리드 라인의 대역을 검출하는 알고리즘을 제안하였으며, 필터전달함수로 Kaiser윈도우와 Butterworth 필터를 조합한 형태의 밴드스톱필러(BSF: band stop filter)를 구현하였다. 또한 블로킹 현상을 개선하기 위하여 다중 영상으로부터 경계선 부분의 픽셀값을 결정하는 방법론을 제안하였다. 제안된 이론에 대하여 실제 영상을 사용한 실험결과로부터 그 타당성을 평가하였다.

미세병변 진단에서 Optimized Grid을 사용한 영상과 Grid Supperession Software를 사용한 영상의 비교분석 (Comparison of Images Using Optimized Grid and Images Using Grid Supperession Software in the Diagnosis of Micro Lesions)

  • 이상호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권2호
    • /
    • pp.149-155
    • /
    • 2018
  • Quantitative analysis was performed to confirm that moire artifact was removed without loss of image when using grid suppression software in the diagnosis of micro lesions. we showed that grid suppression images can be morphologically different from original images as they are significantly lower than those of the optimized grid in the similarity analysis with reference images in mammographic phantom images. We were confirmed that images of microcalcification with smaller signal than noise were lost because the pixel values of all lesions increased significantly after the grid suppression, The change in contrast using the NORMI 13 X-ray test phantom was reduced to 30% of the reference image, This result was significantly lower than the 90% when using the optimized grid. In conclusion, the use of grid suppression software in clinical images should be carefully considered because of the possibility of misdiagnosis due to micro lesion loss and morphological changes.

흉부(胸部) 고관전압(高管電壓) 촬영(撮影)에 있어 Air Gap Technique를 이용한 산란선(散亂線) 경감(輕減)에 관(關)한 연구(硏究) (Reduction of Scattered Radiation by Air Gap Technique for High Kilovoltage Chest Roentgenography)

  • 허준;김창균;강홍석;윤철호;이상석;임한영;송재관
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제3권1호
    • /
    • pp.57-66
    • /
    • 1980
  • X-ray grid is the most important means to reduce the scattered ray from patients, but alternative way is air gap technique that is another name of Groedel technique. This technique is mainly used in chest radiography. Authors performed an experimental study on the air gap technique for chest radiography and obtained the results as follows; 1. In using the high voltage air technique, scattered ray could be reduced effectively, while the percentage of scattered ray was slightly increased than conventional grid technique. 2. In film contrast, 30cm air gap technique was inferior to 12:1 grid technique and contrast improvement was increased when the object was thicker and higher voltage was used. 3. The patient exposure dose was reduced about $25{\sim}45%$ compared with conventional grid technique by air gap technique used.

  • PDF

Electrochemical Properties of (Li0.5-xNaxLa0.5)Ti0.8Zr0.2O3 Ceramics as Improved Electrolyte Materials for Li-ion Batteries

  • Lee, Seung-Hwan;Kim, Hong-Ki;Yun, Ye-Sol;Jeong, Tae-Hoon;Nam, Sung-Pill;Kim, Young-Sung;Kim, Jae-Chul;Lee, Ku-Tak;Im, In-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권2호
    • /
    • pp.96-99
    • /
    • 2014
  • We fabricated $(Li_{0.5-x}Na_xLa_{0.5})Ti_{0.8}Zr_{0.2}O_3$(LNTLZ)ceramics ($0{\leq}x{\leq}0.4$) with a perovskite structure via standard solid state synthesis. The influence of Na content on the structural and electrical properties of LNTLZ ceramics was also investigated. During XRD patterns analysis, all of the samples showed orthorhombic structure. The resistance of LNTLZ ceramics decreased as Na content increased, and the maximum activation energy shows 0.56 eV at x=0.4 at room temperature. These results indicated that LNTLZ ceramics are a candidate for use Lithium ion batteries as electrolytes.

복부 단순 X-선 촬영조건과 환자 피폭에 관한 조사 연구 (A Survey on Patient Dose and Exposure Conditions in Simple Radiography of the Abdomen)

  • 김성수;이선숙;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제19권2호
    • /
    • pp.59-65
    • /
    • 1996
  • We studied exposure techniques and exposure dose for simple abdomen A-P projection for 41 medical facilities that are located in Seoul area. 1. The range of tube voltage used was 60 to 84 kVp, the average tube voltage used was 74 kVp 2. Only 17% of added filter was used. 3. Tube current mostly used was 200 mA, some of them used 400 mA. 4. The grid ratio mostly was used 10 : 1, 54 % of the rare earth screen was used in most facilities. 5. The average skin entrance dose was 4.15 mSv and the dose range was 1.05 mSv to 11.0 mSv.

  • PDF

DR 시스템에서 화질 개선을 위한 VGR 알고리즘의 유용성에 관한 연구 (A Study on the Usefulness of VGR (Virtual Grid Role) Algorithm for Elevation of Image Quality in DR System)

  • 양현진;한동균
    • 한국방사선학회논문지
    • /
    • 제14권6호
    • /
    • pp.763-772
    • /
    • 2020
  • DR 시스템에서 일반X선 검사 시 환자에 의해 물리적으로 발생되는 산란X선으로 인하여 영상의 흐림 현상으로 인해 질 저하를 초래한다. 현재 임상에서는 격자를 사용하여 물리적으로 발생한 산란X선을 제거하여 영상의 대조도를 높이지만, 이로 인해 촬영조건이 증가되기 때문에 환자의 피폭선량이 증가되고 격자에 의한 아티팩트가 생길 가능성이 있다. 따라서, 본 연구에서는 가상 격자 역할을 하는 VGR (virtual grid role) 알고리즘을 사용하여 Non-grid 수준의 촬영조건을 가지고 Real-grid를 사용했을 때와 유사한 영상을 얻어내는데 목적이 있다. Real-grid 영상의 70%의 촬영조건을 가지고 획득한 Non-grid와 VGR 알고리즘 영상의 MTF, SNR, CNR을 비교한 결과 Non-grid와 GLE 알고리즘은 MTF0.5는 0.265와 0.350, MTF0.1은 0.412와 0.467로 차이가 나타났으며 SNR과 CNR도 차이가 있음을 보여줬다. 또한, VGR 알고리즘과 Real-grid 영상의 MTF, SNR, CNR을 비교한 결과 VGR 알고리즘과 Real-grid는 MTF0.5는 0.350과 0.367, MTF0.1은 0.467와 0.483으로 차이가 거의 없었으며 SNR과 CNR도 차이가 거의 없음을 보여줬다.

Ball Grid Array Solder Void Inspection Using Mask R-CNN

  • Kim, Seung Cheol;Jeon, Ho Jeong;Hong, Sang Jeen
    • 반도체디스플레이기술학회지
    • /
    • 제20권2호
    • /
    • pp.126-130
    • /
    • 2021
  • The ball grid array is one of the packaging methods that used in high density printed circuit board. Solder void defects caused by voids in the solder ball during the BGA process do not directly affect the reliability of the product, but it may accelerate the aging of the device on the PCB layer or interface surface depending on its size or location. Void inspection is important because it is related in yields with products. The most important process in the optical inspection of solder void is the segmentation process of solder and void. However, there are several segmentation algorithms for the vision inspection, it is impossible to inspect all of images ideally. When X-Ray images with poor contrast and high level of noise become difficult to perform image processing for vision inspection in terms of software programming. This paper suggests the solution to deal with the suggested problem by means of using Mask R-CNN instead of digital image processing algorithm. Mask R-CNN model can be trained with images pre-processed to increase contrast or alleviate noises. With this process, it provides more efficient system about complex object segmentation than conventional system.

고정 그리드를 사용한 디지털 방사선 영상에서 1차원 필터에 기초한 왜곡의 제거 (Artifact Reduction in Digital Radiography Images with the Stationary Grid Based on 1-Dimensional Filters)

  • 김동식
    • 대한전자공학회논문지SP
    • /
    • 제47권5호
    • /
    • pp.117-126
    • /
    • 2010
  • 산란선을 흡수하여 보다 선명한 x선 영상을 얻기 위하여 산란방지 그리드를 사용하여 투사영상을 얻는데, 이때 그리드로 인한 왜곡이 발생한다. 본 논문에서는 회전된 그리드를 사용하여 투사영상을 얻고 단순한 1차원 저역필터를 영상의 공간영역에서 각 축으로 별도로 적용하여 그리드 왜곡을 효율적으로 제거하는 방법을 제안하고 그 성능을 고찰해 보았다. 제안한 방법은 왜곡 주파수를 별도로 예측할 필요 없이, 회전된 그리드를 사용하여 획득한 영상에 단순한 1차원 필터를 주파수영역이 아닌 공간영역에서 적용하므로 매우 단순하여 쉽게 구현이 가능하며 빠른 계산 속도를 가지는 장점을 가지고 있으면서 그 성능은 주파수영역에서 2차원 필터를 적용한 경우와 유사하다.

상대운동이 있는 중첩격자계에 효율적인 Hole Searching Algorithm 개발 (Efficient Hole Searching Algorithm for the Overset Grid System with Relative Body Motion)

  • 이선형;채상현;오세종;이관중
    • 한국항공우주학회지
    • /
    • 제39권11호
    • /
    • pp.995-1004
    • /
    • 2011
  • Overset 격자계에서 사용되는 Object X-rays Method는 홀점 탐색의 일부인 교차점 탐색에 복잡한 벡터계산을 사용하고 개별 배경격자점에 대하여 물체 내외부를 판별하여 홀점을 탐색하므로 많은 시간이 소요된다. 특히 격자의 상대운동이 있을 경우 매 시간간격 마다 홀점 탐색을 수행해야 하므로 계산 시간이 가중된다. 이러한 문제를 해결하기 위해 본 연구에서는 홀점 탐색시간을 줄일 수 있는 효율적인 탐색 알고리즘을 제안한다. 빠른 탐색을 위해 격자점 수가 줄어든 가상의 표면을 사용하고 복잡한 벡터계산을 통한 교차점 탐색 대신 논리연산자를 사용하는 내외부 판별법을 사용하였다. 또한 개별 배경격자점에 대해 홀점 판별을 수행하는 대신 일괄로 홀점을 지정하여 탐색속도를 향상시켰다. 물체의 상대운동이 있을 경우 가상의 표면이 상대 운동하여 기존 방법에 비해서 홀점 탐색시간을 감소시킬 수 있었다. 임의의 2차원, 3차원 형상에 대하여 기존의 hole searching 알고리즘과 홀점 탐색속도를 비교한 결과를 제시하였다.