DOI QR코드

DOI QR Code

Comparison of Images Using Optimized Grid and Images Using Grid Supperession Software in the Diagnosis of Micro Lesions

미세병변 진단에서 Optimized Grid을 사용한 영상과 Grid Supperession Software를 사용한 영상의 비교분석

  • Lee, Sang-Ho (Glocal industry University cooperation department, Sun Moon University)
  • 이상호 (선문대학교 글로컬 산학협력학부)
  • Received : 2018.04.11
  • Accepted : 2018.04.24
  • Published : 2018.04.30

Abstract

Quantitative analysis was performed to confirm that moire artifact was removed without loss of image when using grid suppression software in the diagnosis of micro lesions. we showed that grid suppression images can be morphologically different from original images as they are significantly lower than those of the optimized grid in the similarity analysis with reference images in mammographic phantom images. We were confirmed that images of microcalcification with smaller signal than noise were lost because the pixel values of all lesions increased significantly after the grid suppression, The change in contrast using the NORMI 13 X-ray test phantom was reduced to 30% of the reference image, This result was significantly lower than the 90% when using the optimized grid. In conclusion, the use of grid suppression software in clinical images should be carefully considered because of the possibility of misdiagnosis due to micro lesion loss and morphological changes.

Keywords

References

  1. Michael Sandborg, David R. Dance, Gudrun Alm Carlsson and Jan Persliden. 'The choice of anti-scatter grids in diagnostic radiology: the optimization of image quality and absorbed dose' Department of Medicine and Care Radio Physics Faculty of Health Sciences, 1993
  2. J. Wang and H. K. Huang, (1994) "Film digitization aliasing artifacts caused by grid line patterns," IEEE Trans. Medical Imaging, 13(2).
  3. D.S. Kim, S. Lee. (2011) "Analysis on the Saturation of Grid Artifact and its Reduction in Digital Radiography Images Based on the Adaptive Filtering". Journal of the institute of electronics engineers of Korea, 48(4), 1-11
  4. D.S. Kim. (2011) "Grid Angle Optimization and Grid Artifact Reduction in Digital Radiography Images Based on the Modulation Model". Journal of the institute of electronics engineers of Korea, 48(3), 30-41.
  5. Hoo-Min Lee, Joon Yoon, Hyun-Ju Kim. (2014) "Effects of Contrast Improvement on High Voltage Rectification Type of X-ray Diagnostic Apparatus". Journal of radiological science and technology. 37(3),187-193
  6. D.S Kim, (2010) "Artifact Reduction in Digital Radiography Images with the Stationary Grid Based on 1-Dimensional Filters". Journal of the Institute of Electronics Engineers of Korea SP, 47(5), 117-126.
  7. D.S. Kim, S. Lee. (2013) "Grid artifact reduction for direct digital radiography detectors based on rotated stationary grids with homomorphic filtering". Med. Phys vol. 40(6):061905. https://doi.org/10.1118/1.4807085
  8. Kato M, et al. (2005) "Clinical efficacy of image processing of grid detection and suppression (GDS) in computed radiography". Nihon Hoshasen Gijutsu Gakkai Zasshi. 61(8), 1158-1169. https://doi.org/10.6009/jjrt.KJ00003943078
  9. Kim, Dong-Sik. (2010) "Artifact Reduction in Digital Radiography Images with the Stationary Grid Based on 1-Dimensional Filters." Journal of the Institute of Electronics Engineers of Korea SP, 47(5), 117-126.
  10. Ryoji Sasada; Masahiko Yamada; Shoji Hara; Hideya Takeo; Kazuo Shimura. (2003) "Stationary grid pattern removal using 2D technique for moire-free radiographic image display", Proceedings Volume 5029, Medical Imaging 2003: Visualization, Image-Guided Procedures, and Display.
  11. Chih-Yang Lin, Wen-Jeng Lee, Shyh-Jye Chen, Ching-Hwa Tsai, Yu-Tai Ching, et. al. (2006) "A Study of Grid Artifacts Formation and Elimination in Computed Radiographic Images". J Digit Imaging. 19(4), 351-361. https://doi.org/10.1007/s10278-006-0630-8
  12. Ubeda, Carlos, et al. (2013) "Influence of the antiscatter grid on dose and image quality in pediatric interventional cardiology X-ay systems." Catheterization and Cardiovascular Interventions, 82(1), 51-57. https://doi.org/10.1002/ccd.24602
  13. Seung-Hun Jeung, Beom-Hui Han, Hong-Ryang Jung. (2017) "Evaluation of Image Quality When Using Grid During Child Chest X-Ray Examination". Journal of radiological science and technology, 40(3), 371-376. https://doi.org/10.17946/JRST.2017.40.3.03
  14. Fritz, Shannon, and A. Kyle Jones. (2014) "Guidelines for anti-scatter grid use in pediatric digital radiography." Pediatric radiology, 44(3), 313-321. https://doi.org/10.1007/s00247-013-2824-9
  15. Tapiovaara, Markku J., Michael Sandborg, and David R. Dance. (1999) "A search for improved technique factors in pediatric fluoroscopy." Physics in medicine and biology 44(2), 537-560 https://doi.org/10.1088/0031-9155/44/2/018
  16. Lee Sang-Ho. (2017) 'Image analysis using Grid suppression software to remove Moire artifact from micro lesions of SD (Sprague Dawley) Rat', Journal of Radiological Science and Technology, 40(4), 575-580 https://doi.org/10.17946/JRST.2017.40.4.06