• Title/Summary/Keyword: X-ray field

Search Result 1,749, Processing Time 0.04 seconds

Evaluation of usability of the shielding effect for thyroid shield for peripheral dose during whole brain radiation therapy (전뇌 방사선 치료 시 갑상선 차폐체의 주변선량 차폐효과에 대한 유용성 평가)

  • Yang, Myung Sic;Cha, Seok Yong;Park, Ju Kyeong;Lee, Seung Hun;Kim, Yang Su;Lee, Sun Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.265-272
    • /
    • 2014
  • Purpose : To reduce the radiation dose to the thyroid that is affected to scattered radiation, the shield was used. And we evaluated the shielding effect for the thyroid during whole brain radiation therapy. Materials and Methods : To measure the dose of the thyroid, 300cGy were delivered to the phantom using a linear accelerator(Clinac iX VARIAN, USA.)in the way of the 6MV X-ray in bilateral. To measure the entrance surface dose of the thyroid, five glass dosimeters were placed in the 10th slice's surface of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. In the same location, to measure the depth dose of the thyroid, five glass dosimeters were placed in the 10th slice by 2.5 cm depth of the phantom with a 1.5 cm interval. The average values were calculated by measured values in five times each, using bismuth shield, 0.5 mmPb shield, self-made 1.0 mmPb shield and unshield. Results : Entrance surface dose of the thyroid were respectively 44.89 mGy at the unshield, 36.03 mGy at the bismuth shield, 31.03 mGy at the 0.5 mmPb shield and 23.21 mGy at a self-made 1.0 mmPb shield. In addition, the depth dose of the thyroid were respectively 36.10 mGy at the unshield, 34.52 mGy at the bismuth shield, 32.28 mGy at the 0.5 mmPb shield and 25.50 mGy at a self-made 1.0 mmPb shield. Conclusion : The thyroid was affected by the secondary scattering dose and leakage dose outside of the radiation field during whole brain radiation therapy. When using a shield in the thyroid, the depth dose of thyroid showed 11~30% reduction effect and the surface dose of thyroid showed 20~48% reduction effect. Therefore, by using the thyroid shield, it is considered to effectively protect the thyroid and can perform the treatment.

Petrological Study on the Spherulitic Rhyolite in the Jangsan Area, Busan (부산 장산 지역의 구과상(球課狀) 유문암에 대한 암석학적 연구)

  • Park, Sumi;Yun, Sung-Hyo
    • The Journal of the Petrological Society of Korea
    • /
    • v.22 no.3
    • /
    • pp.219-233
    • /
    • 2013
  • Spherulitic rhyolite occur as part of ring dyke which showing a vertical flowage of $60^{\circ}{\sim}90^{\circ}$, of the Jangsan cauldron was studied. The spherulites range in diameter from a few millimeters to 2.8 centimeters or more, and average 5~10 millimeters. It belongs to radiated simple spherulite type. They consist of a core of moderate brown dense material encased by a thin crust, a few millimeters thick at most of white grey material. The spherulites frequently have a radiating fibrous structure, which are thought to have formed as a consequence of rapid mineral growth caused by very fast cooling of the dykes in shallow depth near the surface. EPMA examination of the concentric-zoned core of spherulites show that they are mainly composed of cryptocrystalline-fibrous intergrowth of silica minerals and alkali feldspars which have $SiO_2$ 82% or more, $Al_2O_3$ 7~10%, $Na_2O+K_2O$ less than 8%. The feldspar compositions of the spherulites lie essentially within the sanidine field. XRD examination show that spherulites are mainly composed of quartz, sanidine, albite with minor mica, kaolinite and chlorite. According to X-ray mapping, the spherulites are enriched in $SiO_2$ in the core and partly enriched $Na_2O$ or $K_2O$, $Al_2O_3$ in the shell that reflect in compositional zoning with increasing spherulitic devitrification. The feathery and non-equant crystal shapes of spherulites from rhyolite dyke of Jangsan cauldron suggest that they may have formed during the rapid cooling of dyke under the static state, or faster velocity of devitrification from glassy materials than movement velocity of the magma intrusion. The spherulitic rhyolite originated from high-silica(75.4~75.7 wt.%) rhyolite magma.

Radiographic Evaluation of Adenoidal Size and Assessment of Impedance Audiometry in Children (소아 인두편도의 방사선적 고찰 및 Impedance 청력검사 소견)

  • 김주일;김철우;이병희;천경두
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.41.2-41
    • /
    • 1981
  • Tonsillectomy and adenoidectomy are the most common operations in the ENT field. Recent emphasis on careful selection of patients for these procedures derives from concern for complications of surgery, as well as the immunologic and anatomic functions of tonsils and adenoids. Adenoidectomy can relieve nasopharyngeal airway obstruction caused by enlarge adenoids, and can prevent complications such as heart failure and recurrent or chronic otitis media. We researched 117 cases of tonsilloadenoidectomy patients and 266 patients having routine examination from March, 1979 to February, 1981, and described the A/N ratio derived from linear measurements of lateral radiographs of the nasopharynx. The results of Impedance Audiometry and X-ray films from 117 cases of T&A patients were compared: 1) The average A/N ratio by age groups for 266 cases of normal children showed: 0.508 for age group, 0 to 3 years old, 0.533 for age group, 4 to 6 years old, 0.524 for age group, 7 to 9 years old, 0.519 for age group, 10 to 12 years old, 0.507 for age group, 13 to 15 years old, 0.481 for age group over 15 years old. The peak value lies in the age group of 4 to 6 years old. The sex difference of A/N ratio was not significant. 2) The average A/N ratio by age groups from 117 cases of T&A patients showed: 0.709 for age group, 0 to 3 years old, 0.733 for age group, 4 to 6 years old, 0.693 for age group, 7 to 9 years old, 0.707 for age group, 10 to 12 years old, 0.620 for age group, 13 to 15 years old, 0.756 for age group over 15 years old. 3) Among the 117 cases of T&A patients, the average A/N ratio for 57 cases in normal tympanogram was 0.688 and the average A/N ratio for 60 cases in abnormal tympanogram was 0.705. 4) Among 57 cases in abnormal tympanogram: 6 cases (10.5%) showed 0.40-0.59 of A/N ratio, 44 cases (77.2%) showed 0.60-0.79 of A/N ratio, and 7 cases (12.3%) showed 0.80-0.99 of A/N ratio. 5) Among 117 cases of T&A patients, 3 of 15 cases showing A/N ratio under 0.6, and 67 of 102 cases showing A/N ratio over 0.6, had paranasal sinusitis.

  • PDF

Truncation Artifact Reduction Using Weighted Normalization Method in Prototype R/F Chest Digital Tomosynthesis (CDT) System (프로토타입 R/F 흉부 디지털 단층영상합성장치 시스템에서 잘림 아티팩트 감소를 위한 가중 정규화 접근법에 대한 연구)

  • Son, Junyoung;Choi, Sunghoon;Lee, Donghoon;Kim, Hee-Joung
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.111-118
    • /
    • 2019
  • Chest digital tomosynthesis has become a practical imaging modality because it can solve the problem of anatomy overlapping in conventional chest radiography. However, because of both limited scan angle and finite-size detector, a portion of chest cannot be represented in some or all of the projection. These bring a discontinuity in intensity across the field of view boundaries in the reconstructed slices, which we refer to as the truncation artifacts. The purpose of this study was to reduce truncation artifacts using a weighted normalization approach and to investigate the performance of this approach for our prototype chest digital tomosynthesis system. The system source-to-image distance was 1100 mm, and the center of rotation of X-ray source was located on 100 mm above the detector surface. After obtaining 41 projection views with ${\pm}20^{\circ}$ degrees, tomosynthesis slices were reconstructed with the filtered back projection algorithm. For quantitative evaluation, peak signal to noise ratio and structure similarity index values were evaluated after reconstructing reference image using simulation, and mean value of specific direction values was evaluated using real data. Simulation results showed that the peak signal to noise ratio and structure similarity index was improved respectively. In the case of the experimental results showed that the effect of artifact in the mean value of specific direction of the reconstructed image was reduced. In conclusion, the weighted normalization method improves the quality of image by reducing truncation artifacts. These results suggested that weighted normalization method could improve the image quality of chest digital tomosynthesis.

A Case of Lymphangioleiomyomatosis Presenting as a Lung Mass (폐종괴로 나타난 폐의 림프관평활근종증 1례)

  • Park, Seon Cheol;Park, Byung Hoon;Shin, Sang Yun;Jeon, Han Ho;Chung, Kyung Soo;Park, Jun Chul;Jeong, Jaeheon;Kwon, Ji Eun;Park, Moo Suk;Kim, Se Kyu;Chang, Joon;Kim, Sung Kyu;Kim, Young Sam
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.3
    • /
    • pp.289-293
    • /
    • 2007
  • Lymphangioleiomyomatosis (LAM) is a rare disease that affects females of reproductive age. It is characterized by the abnormal proliferation of smooth muscle cells in the lung and along the axial lymphatics. We report a case of lymphangioleiomyomatosis presenting as a lung mass. The patient visited the emergency room because of dyspnea upon exertion. The chest X-ray showed a lung mass in the right lower lung field and a pneumothorax in the left lung. Chest computed tomography revealed a $5{\times}3cm$ sized mass in the right lower lobe and multiple thin-walled small cysts scattered in both lungs. Transbronchial biopsy of the lung mass was performed. The biopsy specimen showed atypical smooth muscle cell proliferation and cystic dilatation of the terminal bronchioles, which confirmed the diagnosis of lymphangioleiomyomatosis. To the best of our knowledge, this is the first case of lymphangioleiomyomatosis presenting as a lung mass.

Synthesis of Nano-Sized Y3Al5O12:Ce3+ Phosphors Prepared by High Energy Beads Milling Process and Their Luminescence Properties

  • Song, Hee-Jo;Kim, Dong-Hoe;Park, Jong-Hoon;Han, Byung-Suh;Hong, Kug-Sun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.386-386
    • /
    • 2012
  • For white light emitting diode (LED) applications, it has been reported that Y3Al5O12:Ce3+ (YAG:Ce) in nano-sized phosphor performs better than it does in micro-sized particles. This is because nano-sized YAG:Ce can reduce internal light scattering when coated onto a blue LED surface. Recently, there have been many reports on the synthesis of nano-sized YAG particles using bottom-up method, such as co-precipitation method, sol-gel process, hydrothermal method, solvothermal method, and glycothermal method. However, there has been no report using top-down method. Top-down method has advantages than bottom-up method, such as large scale production and easy control of doping concentration and particle size. Therefore, in this study, nano-sized YAG:Ce phosphors were synthesized by a high energy beads milling process with varying beads size, milling time and milling steps. The beads milling process was performed by Laboratory Mill MINICER with ZrO2 beads. The phase identity and morphology of nano-sized YAG:Ce were characterized by X-ray powder diffraction (XRD) and field-emission scanning electron microscopy (FESEM), respectively. By controlling beads size, milling time and milling steps, we synthesized a size-tunable and uniform nano-sized YAG:Ce phosphors which average diameters were 100, 85 and 40 nm, respectively. After milling, there was no impurity and all of the peaks were in good agreement with YAG (JCPDS No. 33-0040). Luminescence and quantum efficiency (QE) of nano-sized YAG:Ce phosphors were measured by fluorescence spectrometer and QE measuring instrument, respectively. The synthesized YAG:Ce absorbed light efficiently in the visible region of 400-500 nm, and showed single broadband emission peaked at 550 nm with 50% of QE. As a result, by considering above results, high energy beads milling process could be a facile and reproducible synthesis method for nano-sized YAG:Ce phosphors.

  • PDF

Effect of Surfactants on ZnO Synthesis by Hydrothermal Method and Photocatalytic Properties (계면활성제 첨가에 의한 산화아연의 수열합성과 광촉매 특성)

  • Hyeon, Hye-Hyeon;Lee, Dong-Kyu
    • Journal of the Korean Applied Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.50-57
    • /
    • 2017
  • Zinc oxide is, one of metal oxide semiconductor, harmless to human and environment-friendly. It has excellent chemical and thermal stability properties. Wurtzite-zinc oxide is a large band gap energy of 3.37 eV and high exciton binding energy of 60 meV. It can be applied to various fields, such as solar cells, degradation of the dye waste, the gas sensor. The photocatalytic activity of zinc oxide is varied according to the particle shape and change of crystallinity. Therefore, It is very important to specify the additives and the experimental variables. In this study, the zinc oxide were synthesized by using a microwave assisted hydrothermal synthesis. The precursor was used as the zinc nitrate, the pH value was controlled as 11 by NaOH. Surfactants are the ethanolamine, cetyltrimethylammonium bromide, sodium dodecyl sulfate, sorbitan monooleate was added by changing the concentration. The composite particles had the shape of a star-like, curcular cone, seed shape, flake-sphere. Physical and chemical properties of the obtained zinc oxide was characterized using x-ray diffractometer, field emission scanning electron microscopy, thermogravimetric analysis and optical properties was characterized using UV-visible spectroscopy, photoluminescence and raman spectroscopy.

Electrochemical treatment of wastewater using boron doped diamond electrode by metal inter layer

  • KIM, Seohan;YOU, Miyoung;SONG, Pungkeun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.251-251
    • /
    • 2016
  • For several decades, industrial processes consume a huge amount of raw water for various objects that consequently results in the generation of large amounts of wastewater. Wastewaters are consisting of complex mixture of different inorganic and organic compounds and some of them can be toxic, hazardous and hard to degrade. These effluents are mainly treated by conventional technologies such are aerobic and anaerobic treatment and chemical coagulation. But, these processes are not suitable for eliminating all hazardous chemical compounds form wastewater and generate a large amount of toxic sludge. Therefore, other processes have been studied and applied together with these techniques to enhance purification results. These include photocatalysis, absorption, advanced oxidation processes, and ozonation, but also have their own drawbacks. In recent years, electrochemical techniques have received attention as wastewater treatment process that could be show higher purification results. Among them, boron doped diamond (BDD) attract attention as electrochemical electrode due to good chemical and electrochemical stability, long lifetime and wide potential window that necessary properties for anode electrode. So, there are many researches about high quality BDD on Nb, Ta, W and Si substrates, but, their application in effluents treatment is not suitable due to high cost of metal and low conductivity of Si. To solve these problems, Ti has been candidate as substrate in consideration of cost and property. But there are adhesion issues that must be overcome to apply Ti as BDD substrate. Al, Cu, Ti and Nb thin films were deposited on Ti substrate to improve adhesion between substrate and BDD thin film. In this paper, BDD films were deposited by hot filament chemical vapor deposition (HF-CVD) method. Prior to deposition, cleaning processes were conducted in acetone, ethanol, and isopropyl alcohol (IPA) using sonification machine for 7 min, respectively. And metal layer with the thickness of 200 nm were deposited by DC magnetron sputtering (DCMS). To analyze microstructure X-ray diffraction (XRD, Bruker gads) and field emission scanning electron microscopy (FE-SEM, Hitachi) were used. It is confirmed that metal layer was effective to adhesion property and improved electrode property. Electrochemical measurements were carried out in a three electrode electrochemical cell containing a 0.5 % H2SO4 in deionized water. As a result, it is confirmed that metal inter layer heavily effect on BDD property by improving adhesion property due to suppressing formation of titanium carbide.

  • PDF

The Effect of Trivalent Cation Doping on the Low Temperature Phase Stability of 2Y-TZP (3가 양이온 산화물이 첨가된 2Y-TZP의 저온 상안정성)

  • Jang, Ju-Woong;Kim, Hak-Kwan;Lee, Deuk-Yong;Kim, Dae-Joon;Park, Sun-Min
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.11
    • /
    • pp.1055-1062
    • /
    • 2002
  • The phase stability and the Low Temperature Degradation(LTD) mechanism of Tetragonal Zirconia Polycrystals(TZP), sintered specimens of $Y_2O_3$-Stabilized Zirconia(2Y-TZP), doped with trivalent cations, were evaluated by investigating meachnical properties, Raman spectra, lattice parameter variation and the oxygen vacancy behavior under applied electric field. XRD observation was put forward on 2Y-TZP doped with trivalent cation whose ionic radii were larger than $Zr^{4+}(Sc^{3+},\;Yb^{3+},\;Y^{3+},\;Sm^{3+},\;Nd^{3+},\;La^{3+})$ up to 2 mol% and sintered at 1500 h for 1h. For $La^{3+}$ doping, the stability of tetragonal phase was degraded due to the formation of the pyrochlore phase $(La_2Zr_2O_7)$ as the dopant content increased above exceeded 0.5 mol%. As the dosage increased, tetragonal phase maintained for the case of $Sc^{3+}$, whose radius was similar to $Zr^{4+}$, on the other hand, the cubic phase was formed for the cases of $Yb^{3+},\;Y^{3+},\;Sm^{3+},\;Nd^{3+}$. As the radii of dopant cation increased, c/a ratio increased and it was experimentally observed that the amount of monoclinic phase decreased when the specimens were annealed at $220{\circ}C$ for 500 h.

고감도 형광판을 이용한 실시간 IMRT 선량 분석 가능성 연구

  • 고영은;이병용;안승도;이상욱;김종훈;신성수;최은경
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.36-36
    • /
    • 2003
  • 목적 : 고감도 형광판과 필름을 이용하여 실시간으로 선량을 측정하여 IMRT 선량분포를 검증하는데 사용하는 가능성을 알아보고자 하였다. 대상 및 방법 : 본 연구에서 개발한 물팬텀은 지름 25cm 아크릴 원통과 원통의 중앙부분에 삽입되는 고감도 형광판으로 구성되어 있다. 이를 사용하여 dose linearity correction factor를 구하기 위해 dmax 지점에서 6MV x-ray를 고감도형광판에 조사하여 blurring correction factor를 구하였다. CCD를 이용하여 고감도 형광판에서 나오는 영상을 수집하였다. 고감도 형광판에서 수집한 영상의 x축 profile은 RTP에서 얻은 profile과 비교하였고, 이온전리함으로 scanning한 데이터를 이용하여 고감도 형광판과 물에서 빛에 의한 산란선 때문에 발생하는 blurring effect를 교정하였다. 여기서 계산된 blurring effect factor를 고감도 형광판에서 수집된 영상에 적용하였다. 결과 : CCD 카메라는 형광판의 전 영역을 감지할 수 있고, 조사시간은 형광판의 중첩된 영상의 선량에 비례하였다. 물팬텀에서 형광판의 blurring effect 는 가우시안 분포로 표현할 수 있었다. 또한 Deconvolution kernel은 원통 팬텀에서 지름 $\pm$5cm 이내의 범위에 위치하였고, 따라서 형광판 영상으로부터의 실제 선량분 포를 뽑아낼 수 있었다. RTP 에서 계산된 선량분포와 blurring correction factor로 교정한 후 중첩시켜 얻은 고감도 형광판 영상의 선량분포는 일치하였다. 결론 : 정기적인 IMRT 선량 검증에 대한 실시간 선량측정 방법이 개발되었다. 고감도 형광판 영상과 CCD 카메라를 사용한 물팬텀으로, IMRT 치료계획에 대한 선량분포를 검증할 수 있는 가능성을 보였다.비의 회전에 의한 오차 보정, 필름의 광학적 밀도에 관한 보정 등 여러 가지 계통적 오차들에 대한 보정들이 선량분포 확인과정의 이해와 그 기준마련에 도움이 되겠지만 우리가 다룬 원점 불일치에 비해서 상대적으로 무시할 수 있었다. 마지막으로 선량분포 확인의 최종목표인 3 차원 선량분포 확인의 실제 적용을 위한 연구가 최적화 알고리듬을 이용하여 실험 중에 있다.\times$5cm, 10$\times$10cm, 15$\times$l5cm, 20$\times$20cm인 경우, 측정하여 얻은 PSF가 0.8%, 0.2%, 0.4%, 0.2%로 약간 높지만, 두 값은 매우 유사한 것으로 나타났다. 그리고, 기존의 BSF를 이용해 구한 TAR과 BJR 25에서 권고하는 PSF를 이용해 구한 TAR을 비교한 결과 field size 에 따라 약 1%-1.5% 정도로 BSF를 이용하여 구한 TAR보다 PSF를 이용하여 구한 TAR이 1.3% 정도 높게 나타났지만, 이것은 두 값의 절대적인 차이일 뿐, 실제로는 PSF를 이용하여 구한 TAR이 측정해서 구한 TAR과는 매우 유사한 값을 보여주고 있다. 결론 : 기존의 BSF를 이용해 구한 TAR과 PSF를 이용해 구한 TAR을 비교하였을 때, 약 1.3% 정도 높게 내고 있지만, 기존의 TAR보다는 PSF를 이용해 구한 TAR이 BJR 25와 잘 일치하고 있으므로 Co-60 원격치료용 방사선 조사장치를 사용할 경우 BSF보다는 PSF를 사용하는 것이 타당한 것으로 사료된다.tokines의 변화는 비록 통계학적인 차이는 없지만 비타민 C를 사용한 환자의 cytokines이 모두 사용하지 않은 환자에 비해 감소하였음을 보였다. 비타민 C는 부작용이 거의 없는 안전한 약으로서 말기 암 환자에서 비타민 C사용은 임상 증상을 호전시키는 데 도움

  • PDF