• 제목/요약/키워드: X-ray equipment

검색결과 313건 처리시간 0.024초

X선진단(X線診斷) 부문(部門)에 있어서 업무량(業務量)에 관(關)한 조사연구(調査硏究)(II) (A Study on Activities of Diagnostic X-ray Examination(II))

  • 경광현;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제1권1호
    • /
    • pp.44-54
    • /
    • 1978
  • This study was carried out with statistical materials during the last two years of period from Jan. 1975 to Dec. 1976 which presented at radiologic department of 5 hospitals in Seoul City. The primary purpose of this study was to obtained more detailed informations related to the activities of radiologic technologists in diagnostic X-Ray examinations part and to provide some basic materials for managements in activities of then and manpower managements of their organization and practice. From the results of this study, the following conclusions were obtained [1] During two year from the January of 1975 to the December of 1976, total number of case in X-ray examinations were 464,830 case and 22,029 case in 1975 and 24,461 in 1976. And ratio of icreased in X-Ray examinations by year was 11.09 per cent. [2] Regarding the examined portion of X-Ray examination, a great propotion was chest examination as 56.88 per cent. [3] An average, the required time per case in X-Ray exam. was 9.28 minutes and make used of 1.94 sheets of X-Ray film per case in radiography. [4] An average, ratio of increased in X-Ray film by year was 12.71 per cent and ratio of failed film in it was 2.23 per cent. [5] The frequency rate of film size showed the highest distribution of $8"{\times}10"$(28.17%) and the highest distribution of X-Ray film by month was July(8.93%). [6] An average, the amount of activities per a diagnostic X-Ray equipment was 34.92 case and make used of 67.81 sheets of X-Ray film in a day. [7] The mean number of case in X-Ray examinations by radiologic technologists was 29.29 cases and make used of 56.87 sheets of X-Ray film in a day. Also, the average number of case was reading by radiologists was 32.42 case and 62.97 sheets of X-Ray film in a day.

  • PDF

X-ray tube 내 열유동 해석에 관한 연구 (A study on the analysis of heat flow in X-ray tube)

  • 윤동민;서병석;전용한
    • Design & Manufacturing
    • /
    • 제15권1호
    • /
    • pp.26-31
    • /
    • 2021
  • As the aging ages, the disease also increases, and the development of AI technology and X-ray equipment used to treat patients' diseases is also progressing a lot. X-ray tube converts only 1% of electron energy into X-ray and 99% into thermal energy. Therefore, when the cooling time of the anode and the X-ray tube are frequently used in large hospitals, the amount of X-ray emission increases due to temperature rise, the image quality deteriorates due to the difference in X-ray dose, and the lifespan of the overheated X-ray tube may be shortened. Therefore, in this study, temperature rise and cooling time of 60kW, 75kW, and 90kW of X-ray tube anode input power were studied. In the X-ray Tube One shot 0.1s, the section where the temperature rises fastest is 0.03s from 0s, and it is judged that the temperature has risen by more than 50%. The section in which the temperature drop changes most rapidly at 20 seconds of cooling time for the X-ray tube is 0.1 seconds to 0.2 seconds, and it is judged that a high temperature drop of about 65% or more has occurred. After 20 seconds of cooling time from 0 seconds to 0.1 seconds of the X-ray tube, the temperature is expected to rise by more than 3.7% from the beginning. In particular, since 90kW can be damaged by thermal shock at high temperatures, it is necessary to increase the surface area of the anode or to require an efficient cooling system.

이동형 치과 X선 발생장치의 공간선량 분포 (Spatial Dose Distribution from Portable Hand-Held Dental X-Ray Equipment)

  • 한경순;안성민
    • 치위생과학회지
    • /
    • 제15권3호
    • /
    • pp.254-258
    • /
    • 2015
  • 치과병의원에서 사용하고 있는 이동형 치과 X선 발생장치를 이용하여 두경부 마네킹에 X선을 조사할 때 주변의 공간선량을 측정하고, 동일한 방법으로 고정형 X선 발생장치에 적용하여 측정된 공간선량을 상호 비교하며, 더불어 기기 및 위치별 공간선량을 비교 분석한 결과는 다음과 같다. 이동형 X선 발생장치의 평균 공간선량은 $37.51{\mu}Sv$로 고정형 X선 발생장치의 $10.77{\mu}Sv$보다 매우 높았다(p<0.001). 이동형 X선 발생장치의 기기별 공간선량은 $17.77{\mu}Sv$부터 $68.90{\mu}Sv$까지 큰 차이를 나타냈다(p<0.05). 위치별로는 직전 위치가 $54.14{\mu}Sv$로 가장 높았고, 직우 위치가 $13.60{\mu}Sv$로 가장 낮았으며, 직좌와 직후 위치는 $42.12{\mu}Sv$, $40.18{\mu}Sv$로 유사하였다(p<0.01). 이상의 결과를 통해 이동용 치과 X선 발생장치는 이동 불가능한 환자만을 대상으로 제한적으로 시행하여야 하며, 반드시 환자와 술자 모두 납 방어복을 착용하여 방사선 피폭을 최소화해야 할 것이다.

이동형 방사선 발생장치 차폐물 설치에 관한 연구 (A study on Protector Performance Evaluation According to X-ray Scattering Distribution of Portable Radiation System)

  • 김형균;성동근;조경미;김상범;김재영;최준호
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.85-92
    • /
    • 2009
  • This study, "The study about performance evaluations of mobile cover for X-ray's diffusion and distribution in mobile radiation" is based on the rules of mobile defense apparatus for radiation producer in 2006. To use the mobile cover for X-ray for diagnosis has been compulsory in common wards except operation rooms, emergency rooms and intensive care units. we have confirmed the effect in arbitrary shielding material after Qualitiy Control was carried out for accuracy in an experiment of mobile photographing equipment. The performance evaluation was conducted with the fabrics of selenium, 0.2 mmPb, 0.1 mmPb and aluminiums. Considering the result, we choosed 0.1 mmPb and attached cover to mobile photographing equipment. We have finished making the cover after drew up the draft to attach cover to mobile photographing equipment through the modeling and the structural analysis. the process of the study is that we assembled the manufactured structures and carried out the practical experiment to take the photograph after attaching the fabric of 0.1 mmPb to mobile photographing equipment. It is need of additional thesises hereafter that we compare the result between the part to improve for safety besides convenience in photographic experiment about clinical radiation and the effect of covering the diffusion in condition attached the cover.

  • PDF

NON-DESTRUCTIVE DETECTION FOR FOREIGN MATERIALS IN FOOD AND AGRICULTURAL PRODUCTS USING X-RAY SYSTEM

  • Morita, Kazuo;Tanaka, Shun'ichirou;Ogawa, Yukiharu
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.334-343
    • /
    • 1996
  • Quality evaluation for food and agricultural products have always been one of the most elusive problems associated with the handling , processing and marketing in a food plant production. In order to detect physical foreign materials in food and agricultural products, non-destructive techniques have been developed for many years. Application of X-ray system to detect physical foreign materials in food and agricultural products could be considered to be a high potential method. Especially , it is impossible to detect internal physical foreign materials by visual inspections. In this study, it was tried to be applied for two different X-ray devices. Soft X-ray system with CdTe sensor and X-ray CT scanner were evaluated for advantage of the detection of non-meltallic foreign materials in food and agricultural products . Though the soft X-ray is not a high energy radiation, it is possible to detect small different density in a material. The CdTe sensor has a high resolution for t e soft X-ray energy region. The density characteristics of foods and foreign material were expressed region. The density characteristics of foods and foreign materials were expressed as a soft X-ray energy spectrum. The energy spectrum was analyzed by a personal computer with a multi-channel analyzer. X-ray CT scanner can provide visual image and analyze by three dimensional information inside food and agricultural products. The X-ray CT scanner using as a medical equipment was used to detect a foreign material. The density characteristics of food and foreign materials in food were tried to be detected by the threshold value on the basis of the CT numbers. The soft X-ray absorption characteristics for acrylin plates and distilled water were obtained and could be found the possibility of detecting a small physical foreign materials such as a plastic wrapping film , a stone and grasshopper in food and agricultural products.

  • PDF

포틀랜드 시멘트 클린커 광물조성의 X선구절에 의한 정량분석 (Quantitative Analysis of Mineral Composition in Porland Cement Clinker by X-ray Diffraction)

  • 장세경;이전;한기성
    • 한국세라믹학회지
    • /
    • 제23권2호
    • /
    • pp.64-70
    • /
    • 1986
  • In this investigation x-ray diffraction method was mainly studied for quantitative analysis of clinker mineral composition. And also optical microscopic observation and Bogue calculation method were applied to compare with the x-ray diffraction method. In the procedure of x-ray diffraction analysis graphite monochromator automatic divergence slit and spinner for sample holder were used for minimizing the error due to the operation of the equipment. Especially the separation of overlapped peaks were proceeded by micro-processor automatically. The results of x-ray diffraction method for synthesized clinker were consistent with the Bogue value and the results of optical microscopic observation. However the results of quantitative analysis of mineral composition or commercial clinker containing solid solution of minor component were different from the Bogue value. On the other hand they agreed reasonably well with results of the optical mic-roscopic observation.

  • PDF

골밀도 장치의 교차분석 ; 국내 제조사와 해외 제조사 비교 (Cross Calibration of Dual Energy X-ray Absorptiometry Equipment for Diagnosis of Osteoporosis: between Domestic Manufacturers and Global Manufacturers)

  • 김정수
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.833-844
    • /
    • 2018
  • 골다공증의 진단에서 이중에너지 X선 흡수계수법은 가장 빈번하게 사용되는 검사이다. 외국의 골밀도 장치 제조사인 지이나 홀로직 장치에 대한 교차분석 연구는 다양하나 국내 제조사 이중에너지 X선 흡수골밀도 장치에 대한 비교 분석이 부족하다. 이에 본 연구에서는 국내 제조사의 이중에너지 X선 흡수골밀도 장치와 해외 제조사의 이중에너지 X선 흡수 골밀도 장치의 교차분석을 시행하여 교차식을 수립하였다. 유럽인 척추 팬텀을 이용한 검사에서 가장 높은 표준 편차를 보인 Dexxum T 장치의 경우 상. 중. 하부 척추에서0.030, 0.029, 0.037를 보였고, 홀로직의 Horizon Ci에서는 0.005와 0.004로 하부와 중간 척추에서 가장 낮은 표준편차를 나타냈다. 오스테오 프로맥스 장치의 경우 상부 척추에서 0.005의 표준편자를 나타냈다. 본 연구에서 도출한 국내 외 이중에너지 흡수 골밀도 장치의 교차식은 임상환경에서 골밀도 검사의 추척검사에 유용한 사례가 될 것이다. 또한 본 연구에서 제시한 국산 이중에너지 X선골밀도 장치에 대해 설정된 교차 방정식에 기초로 임상환경에서 보다 정확한 골밀도 추적 관찰을 위해 보다 다양한 국산 이중에너지 X선 골밀도 장치의 교차 보정을 설정하는 것이 필요하다.

진단용 엑스선 장치에 있어서 방사선 방어에 대한 일반 요구사항 -IEC 60601-1-3:2008에 근거한 KFDA DRS 1-1-3:2008- (General Requirements Pertaining to Radiation Protection in Diagnostic X-ray Equipment -KFDA DRS 1-1-3 : 2008 base on IEC 60601-1-3:2008-)

  • 강희두;동경래;권대철;최준구;정재호;정재은;류영환
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.69-77
    • /
    • 2009
  • This study gives an account of the collateral standards in IEC 60601-1-3: 2008 specifying the general requirements for basic safety and essential performance of diagnostic X-ray equipment regarding radiation protection as it pertains to the production of X-rays. The collateral standards establish general requirements for safety regarding ionization radiation in diagnostic radiation systems and describe a verifiable evaluation method of suitable requirements regarding control over the lowest possible dose equivalent for patients, radiologic technologists, and others. The particular standards for each equipment can be determined by the general requirements in the collateral standard and the particular standard is followed in the risk management file. The guidelines for radiation safety of diagnostic radiation systems is written up in ISO 13485, ISO 14971, IEC 60601-1-3(2002)1st edition, medical electric equipment part 1-3, and the general requirements for safety-collateral standards: programmable electrical medical systems. Therefore the diagnostic radiation system protects citizens' health rights with the establishment and revisions of laws and standards for diagnostic radiation systems as a background for the general requirements of radiation safe guards applies, as an international trend, standards regarding the medical radiation safety management. The diagnostic radiation system will also assure competitive power through a conforming evaluation unifying the differing standards, technical specifications, and recognized processes.

  • PDF

진단용 X선 발생 장치의 X선 출력에 관한 연구 (A Study of X-ray Output for Diagnostic X-ray Equipment)

  • 고신관;안봉선;장상섭;최종운;신영순
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제18권2호
    • /
    • pp.61-73
    • /
    • 1995
  • For the managements of the diagnostic X-ray equipments, the authors examined the output of single phase rectification assembly, Three phase rectification assembly and serial radiographic appartus, and got the following conclusions. 1. When the tube voltages in X-ray control panels ware compared to the measured values on the kVp pulse meter, only little differences were detected in all the X-ray equipments. And most of the equipments were all well managed within the internationally permitted limits, excepting the 12.02 % error at 120 kVp in three phase rectifying assembly. 2. As for the X-ray qualities affecting the X-ray images, the serial radiographic apparatus showed excellence, while the single phase rectification assembly were somewhat inferior to the others only maining the internationally recommended limits. 3. The tube voltage ranges where the X-ray output showed excellence were $100{\sim}200\;mA$ in serial radiographic apparatus, $200{\sim}350\;mA$ in three phase rectification assembly and $350{\sim}400\;mA$ in single phase rectification assembly respectively. 4. In the repeatability test of the X-ray equipments, CVs were in the range of $0.0029{\sim}0.049$, which is within the HEW or KS standards. Consequently all the equipments are thought to be well-manage. 5. This study on characteristics and output of the X-ray equipments was accomplished within a limited short time. Long-time researches on the function managements for the X-ray equipments should be followed along with the periodical checking the output for reduction of X-ray exposures to the patients or radio-technologists, and for maintanance and prediction of trouble of the equipments.

  • PDF

무연 방사선 차폐 시트에 대한 몬테카를로 전산모사 (Monte Carlo Simulation for Radiation Protection Sheets of Pb-Free)

  • 천권수
    • 한국방사선학회논문지
    • /
    • 제11권4호
    • /
    • pp.189-195
    • /
    • 2017
  • 방사선 특히, 엑스선 또는 감마선으로부터 인체를 보호하기 위해 납(Pb)으로 된 보호 장구를 광범위하게 사용해왔다. 최근 납 중독 및 환경오염의 문제로 납을 대신하는 무연 방사선 차폐재의 개발이 활발히 이루어지고 있다. 차폐재의 성능 확보를 위해서는 제작 및 평가의 순환 사이클을 반복하게 된다. 본 연구는 실제 무연 방사선 차폐소재의 제작에 앞서 차폐재의 성능을 몬테카를로 전산모사를 통해 확인함으로써 가능한 차폐소재의 조합을 연구하였다. 방사선 차폐소재의 평가에 사용되는 조건으로 엑스선관을 Geant4를 이용하여 전산모사하고 획득된 광자 스펙트럼을 이용하여 텅스텐과 비스무스의 조합에 따른 차폐소재의 성능을 평가하였다. 차폐소재의 공극에 따른 성능 저하도 평가하였다. 방사선 차폐 소재 개발 시 공극률을 줄이는 것이 중요한 인자라는 것을 알 수 있었다.