• 제목/요약/키워드: X-ray energy spectrum

검색결과 218건 처리시간 0.029초

Energy Spectrum Measurement of High Power and High Energy (6 and 9 MeV) Pulsed X-ray Source for Industrial Use

  • Takagi, Hiroyuki;Murata, Isao
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.93-99
    • /
    • 2016
  • Background: Industrial X-ray CT system is normally applied to non-destructive testing (NDT) for industrial product made from metal. Furthermore there are some special CT systems, which have an ability to inspect nuclear fuel assemblies or rocket motors, using high power and high energy (more than 6 MeV) pulsed X-ray source. In these case, pulsed X-ray are produced by the electron linear accelerator, and a huge number of photons with a wide energy spectrum are produced within a very short period. Consequently, it is difficult to measure the X-ray energy spectrum for such accelerator-based X-ray sources using simple spectrometry. Due to this difficulty, unexpected images and artifacts which lead to incorrect density information and dimensions of specimens cannot be avoided in CT images. For getting highly precise CT images, it is important to know the precise energy spectrum of emitted X-rays. Materials and Methods: In order to realize it we investigated a new approach utilizing the Bayesian estimation method combined with an attenuation curve measurement using step shaped attenuation material. This method was validated by precise measurement of energy spectrum from a 1 MeV electron accelerator. In this study, to extend the applicable X-ray energy range we tried to measure energy spectra of X-ray sources from 6 and 9 MeV linear accelerators by using the recently developed method. Results and Discussion: In this study, an attenuation curves are measured by using a step-shaped attenuation materials of aluminum and steel individually, and the each X-ray spectrum is reconstructed from the measured attenuation curve by the spectrum type Bayesian estimation method. Conclusion: The obtained result shows good agreement with simulated spectra, and the presently developed technique is adaptable for high energy X-ray source more than 6 MeV.

A New Approach on the Correction for Compton Escape Component in X-Ray Unfolding Algorithm

  • Kim, Soon-Young;Kim, Jong-Kyung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1995년도 추계학술발표회논문집(2)
    • /
    • pp.925-930
    • /
    • 1995
  • A new approach on the correction for Compton escape component in X-ray unfolding algorithm was investigated to obtain more accurate X-ray source spectrum. The X-ray detector used in this study was a planar type HPGe detector(EG&G ORTEC, GLP-32340/13-P-LP) whose energy response has been blown and ISO narrow beam series were employed as source spectrum. At lower energy Part of measured X-ray spectrum including the correction for Compton escape component more accurate unfolded spectrum was obtained by letting down the starting energy level of the collection in existing spectrum correction procedure to consider multiple scattering effects. It is, from this study, concluded that accurate correction for Compton escape component is needed in X-ray unfolding procedure since Compton scattering becomes more important as incident X-ray energies increase.

  • PDF

엑스선 에너지스펙트럼 변경을 통한 영상 화질 향상에 관한 연구 (Image Quality Improvement through Energy Spectrum Change for X-ray)

  • 김구;김능균;이승재
    • 한국방사선학회논문지
    • /
    • 제15권1호
    • /
    • pp.71-78
    • /
    • 2021
  • 엑스선 영상을 획득하는 경우에 연속 엑스선을 사용할 경우, 다양한 엑스선 에너지로 인해 같은 물질이라도 두께에 따라 영상에서 정확하게 표현되지 않을 수 있다. 이를 해결하기 위해 엑스선 에너지스펙트럼을 변경하여 영상의 질을 향상 시킬 수 있도록 하였다. SPEKTR v3.0을 사용하여 부가 필터를 추가한 엑스선 에너지스펙트럼과 고유 필터만을 사용한 일반 엑스선 에너지스펙트럼을 획득하였다. 획득한 엑스선 에너지스펙트럼을 Geant4 Application for Tomographic Emission(GATE)의 방사선원으로 사용하여 시뮬레이션을 수행하였다. GATE 데이터를 사용하여 부가 필터가 사용된 엑스선 영상과 부가 필터를 사용하지 않은 엑스선 영상을 재구성한 영상을 74 keV의 단일 에너지 영상을 통해서 비교 분석하였다. 부가 필터를 사용하지 않은 엑스선 에너지스펙트럼을 사용한 경우 같은 물질이라도 두께에 따라 투과한 엑스선의 양이 물질 두께에 따라 감소되는 양과는 상이한 양상을 보인 반면, 부가 필터를 사용한 경우 두께에 따라 투과된 엑스선의 양이 물질 두께에 따라 감소되는 양과 유사한 결과가 나왔다. 즉, 감소되는 선량이 단일 에너지를 사용했을 때와 비슷한 결과가 나왔다. 부가 필터를 사용하여 엑스선 에너지스펙트럼을 변경하여 엑스선 영상을 획득할 경우 엑스선의 투과에 대한 보다 정확한 결과의 값을 획득할 수 있다. 영상의학검사에서 부가 필터의 적절한 사용이 영상의 질을 높이는데 크게 작용한다는 것을 확인하였다.

X-선 스펙트럼 변조 기술 연구 (X-Ray Spectrum Modulation for Mammography)

  • 김광현;김경락;오창현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술회의 논문집 정보 및 제어부문 B
    • /
    • pp.600-603
    • /
    • 2003
  • Energy spectrum modulation of X-ray source in digital mammography has been studied. In this study, we calculated various filtered spectra using the scattering data. Primary spectra were generated by Molybdenum (Mo) and Tungsten (W) targets. The materials of added filters are Molybdenum and Rhodium (Rh) for 40 kVp Mo. primary spectrum, the amounts of photons over whole energy ranges are attenuated to 0.43 with 0.03 mm Mo filter and 0.38 with 0.06 mm Mo filter while the photons of energy ranged from 17 keV to 20 keV. The photons of low energy ranged below 17 keV are considerably attenuated. This effect brings out reducing the scattered radiation and dose to the patient, and enhancing subject contrast in the image. The results show that filtered spectra are not seriously affected by X-ray tube loadability. Because the energy range from 17 keV to 20 keV is directly transmitted although low and high energies are mainly filtered.

  • PDF

이중 에너지 방사선 검출기 개발 (Development of Dual Energy Radiation Detector)

  • 여화연
    • 한국방사선학회논문지
    • /
    • 제4권3호
    • /
    • pp.5-11
    • /
    • 2010
  • 본 논문에서는 이중 에너지 디지털 래디오그래피를 위한 이중 모드 검출기 개발을 제안한다. 이중 에너지 래디오그래피 모듈의 설계를 위하여 상용 BIS(Baggage Inspection System)에서 사용되고 있는 X-선 발생장치의 스펙트럼과 이중 모드 검출기에 대한 특징 및 방사선적 특성을 분석하였다. 제안하는 영상 검출기 모듈은 BIS에서 활용되고 있는 X-선관을 대상으로 X-선 스펙트럼을 모사하고, 모사한 스펙트럼을 통하여 새롭게 제안하는 검출기 모듈의 방사선적 특성을 고찰하였다. X-ray를 이용한 실험에서 구리 필터의 두께 증가에 따라 저에너지 검출기(LED)와 고에너지 검출기(HED)의 출력신호의 차이는 같이 증가하였다. 특히 HED에서의 출력신호의 크기는 구리 필터 두께가 증가 할수록 감소함을 알 수 있었다.

Development of a neural network method for measuring the energy spectrum of a pulsed electron beam, based on Bremsstrahlung X-Ray

  • Sohrabi, Mohsen;Ayoobian, Navid;Shirani, Babak
    • Nuclear Engineering and Technology
    • /
    • 제53권1호
    • /
    • pp.266-272
    • /
    • 2021
  • In the pulsed electron beam generators, such as plasma focus devices and linear induction accelerators whose electron pulse width is in the range of nanosecond and less, as well as in cases where there is no direct access to electron beam, like runaway electrons in Tokamaks, measurement of the electron energy spectrum is a technical challenge. In such cases, the indirect measurement of the electron spectrum by using the bremsstrahlung radiation spectrum associated with it, is an appropriate solution. The problem with this method is that the matrix equation between the two spectrums is an ill-conditioned equation, which results in errors of the measured X-ray spectrum to be propagated with a large coefficient in the estimated electron spectrum. In this study, a method based on the neural network and the MCNP code is presented and evaluated to recover the electron spectrum from the X-ray generated by collision of the electron beam with a target. Multilayer perceptron network showed good accuracy in electron spectrum recovery, so that for the X-ray spectrum with errors of 3% and 10%, the network estimated the electron spectrum with an average standard error of 8% and 11%, on all of the energy intervals.

Laplace transform 방법에 의한 x-ray의 에너지 스펙트럼 추정 (Estimated spectrum of a 6MV X-ray)

  • Yoo, Myung-Jin
    • 한국의학물리학회지:의학물리
    • /
    • 제4권2호
    • /
    • pp.37-47
    • /
    • 1993
  • Jones 모델 및 HKB모델을 이용하여 Laplace transform방법으로 6MV X-ray의 대략적인 에너지 스펙트럼을 분석하였다. Jones모델은 투과계수 0.1이하에서는 Laplace transform방법이 적용될 수 없는 심한 제약을 받는다는 것을 알 수 있었다. HKB모델에 의한 에너지 스펙트럼은 대체로 실제의 에너지 스펙트럼과 일치하는 형태를 나타내지만 6MeV에너지 이상의 영역에서 길게 꼬리를 이루는 단점이 있었다.

  • PDF

PCB 비파괴 검사에 있어서 단일 에너지 소스와 이중 에너지 소스의 영상비교를 위한 엑스선 스펙트럼 분석 (Energy Spectrum Analysis between Single and Dual Energy Source X-ray Imaging for PCB Non-destructive Test)

  • 김명수;김기윤;이민주;강동욱;이대희;박경진;김예원;김찬규;김형택;조규성
    • 방사선산업학회지
    • /
    • 제9권3호
    • /
    • pp.153-159
    • /
    • 2015
  • Reliability of printed circuit board (PCB), which is based on high integrated circuit technology, is having been important because of development of electric and self-driving car. In order to answer these demand, automated X-ray inspection (AXI) is best solution for PCB non-destructive test. PCB is consist of plastic, copper, and, lead, which have low to high Z-number materials. By using dual energy X-ray imaging, these materials can be inspected accurately and efficiently. Dual energy X-ray imaging, that have the advantage of separating materials, however, need some solution such as energy separation method and enhancing efficiency because PCB has materials that has wide range of Z-number. In this work, we found out several things by analysis of X-ray energy spectrum. Separating between lead and combination of plastic and copper is only possible with energy range not dose. On the other hand, separating between plastic and copper is only with dose not energy range. Moreover the copper filter of high energy part of dual X-ray imaging and 50 kVp of low energy part of dual X-ray imaging is best for efficiency.

A Copper Shield for the Reduction of X-γ True Coincidence Summing in Gamma-ray Spectrometry

  • Byun, Jong-In
    • Journal of Radiation Protection and Research
    • /
    • 제43권4호
    • /
    • pp.137-142
    • /
    • 2018
  • Background: Gamma-ray detectors having a thin window of a material with low atomic number can increase the true coincidence summing effects for radionuclides emitting X-rays or gamma-rays. This effect can make efficiency calibration or spectrum analysis more complicated. In this study, a Cu shield was tested as an X-ray filter to neglect the true coincidence summing effect by X-rays and gamma-rays in gamma-ray spectrometry, in order to simplify gamma-ray energy spectrum analysis. Materials and Methods: A Cu shield was designed and applied to an n-type high-purity germanium detector having an $X-{\gamma}$ summing effect during efficiency calibration. This was tested using a commercial, certified mixed gamma-ray source. The feasibility of a Cu shield was evaluated by comparing efficiency calibration results with and without the shield. Results and Discussion: In this study, the thickness of a Cu shield needed to avoid true coincidence summing effects due to $X-{\gamma}$ was tested and determined to be 1 mm, considering the detection efficiency desired for higher energy. As a result, the accuracy of the detection efficiency calibration was improved by more than 13% by reducing $X-{\gamma}$ summing. Conclusion: The $X-{\gamma}$ summing effect should be considered, along with ${\gamma}-{\gamma}$ summing, when a detection efficiency calibration is implemented and appropriate shielding material can be useful for simplifying analysis of the gamma-ray energy spectra.

NON-DESTRUCTIVE DETECTION FOR FOREIGN MATERIALS IN FOOD AND AGRICULTURAL PRODUCTS USING X-RAY SYSTEM

  • Morita, Kazuo;Tanaka, Shun'ichirou;Ogawa, Yukiharu
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1996년도 International Conference on Agricultural Machinery Engineering Proceedings
    • /
    • pp.334-343
    • /
    • 1996
  • Quality evaluation for food and agricultural products have always been one of the most elusive problems associated with the handling , processing and marketing in a food plant production. In order to detect physical foreign materials in food and agricultural products, non-destructive techniques have been developed for many years. Application of X-ray system to detect physical foreign materials in food and agricultural products could be considered to be a high potential method. Especially , it is impossible to detect internal physical foreign materials by visual inspections. In this study, it was tried to be applied for two different X-ray devices. Soft X-ray system with CdTe sensor and X-ray CT scanner were evaluated for advantage of the detection of non-meltallic foreign materials in food and agricultural products . Though the soft X-ray is not a high energy radiation, it is possible to detect small different density in a material. The CdTe sensor has a high resolution for t e soft X-ray energy region. The density characteristics of foods and foreign material were expressed region. The density characteristics of foods and foreign materials were expressed as a soft X-ray energy spectrum. The energy spectrum was analyzed by a personal computer with a multi-channel analyzer. X-ray CT scanner can provide visual image and analyze by three dimensional information inside food and agricultural products. The X-ray CT scanner using as a medical equipment was used to detect a foreign material. The density characteristics of food and foreign materials in food were tried to be detected by the threshold value on the basis of the CT numbers. The soft X-ray absorption characteristics for acrylin plates and distilled water were obtained and could be found the possibility of detecting a small physical foreign materials such as a plastic wrapping film , a stone and grasshopper in food and agricultural products.

  • PDF