• 제목/요약/키워드: X-ray dose rate

검색결과 167건 처리시간 0.029초

방사선방어 앞치마 성능 평가 (Performance Evaluation of Radiation Protection Apron's)

  • 강종구;강병삼
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권5호
    • /
    • pp.373-377
    • /
    • 2019
  • Radiation exposure is on the rise as the working hours of radiation workers increase. Accordingly, the importance of protection products for decreasing the dose of exposure has risen, and excellent X-ray shielding ability and light weight are required. The purpose of this study is to compare the Pb which use currently and other elements in order to reduce the exposure of workers to the most effective protection products. For experiment, we used the general X-ray equipment and angiography equipment, and obtained the Pb and apron's shielding rate. When the shielding rate of Pb and apron was compared in general X-ray equipment, the shielding rate was 95.1% for Pb 0.5 mm, 96.1% for apron 0.5 mmPb and 95.6% for Bi+W 0.5 mmPb. When compared the shielding rate of each aprons in angiography equipment, 0.5 mmPb apron was the highest as 96.4% and Bi+W 0.25 mmPb apron was the lowest as 90.2% at the 50 cm distance. The shielding rate of 0.5 mmPb apron was the highest as 95.7% and Bi+W 0.25 mmPb apron was the lowest as 85.9% at the 100 cm distance. As a result of evaluating the apron efficiency through this study, 0.5 mmPb apron showed the best shielding rate, but it was the heaviest apron. 0.35 mmPb apron and Bi+W 0.25 mmPb apron weighed light but had low shielding rate. Through the results of this experiment, it is recommended that radiation workers reduce radiation exposure by using more efficient protection products.

APPLICATION OF ALANINE/ESR SPECTRUM SHAPE CHANGE IN GAMMA DOSIMETRY

  • Choi, Hoon;Kim, Jeong-In;Lee, Byung-Ill;Lim, Young-Ki
    • Nuclear Engineering and Technology
    • /
    • 제42권3호
    • /
    • pp.313-318
    • /
    • 2010
  • Alnine pellets were installed in a nuclear power plant for one or two operation cycles and measured by electron spin resonance (ESR) spectrometers for dosimetry. Dose and "x/y ratio", i.e., satellite peak over main center peak ratio, were measured for the returned alanine dosimeters from the nuclear power plant and compared to the values of reference alanine dosimeters exposed only to gamma rays. The variation of the x/y ratio change depended on the population of radicals from each radiation component with different LET. The gamma dose in a mixed radiation field was estimated by an additive gamma ray irradiation experiment and the measured dose rate at specified locations in the containment building.

Exterior 투영데이터를 이용한 Region-of-Interest CT의 반복적 영상재구성 방법 (An Iterative Image Reconstruction Method for the Region-of-Interest CT Assisted from Exterior Projection Data)

  • 진승오;권오경
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권5호
    • /
    • pp.132-141
    • /
    • 2014
  • In an ordinary CT scan, a large number of projections with full field-of-view (FFOV) are necessary to reconstruct high resolution images. However, excessive x-ray dosage is a great concern in FFOV scan. Region-of-interest (ROI) CT or sparse-view CT is considered to be a solution to reduce x-ray dosage in CT scanning, but it suffers from bright-band artifacts or streak artifacts giving contrast anomaly in the reconstructed image. In this study, we propose an image reconstruction method to eliminate the bright-band artifacts and the streak artifacts simultaneously. In addition to the ROI scan for the interior projection data with relatively high sampling rate in the view direction, we get sparse-view exterior projection data with much lower sampling rate. Then, we reconstruct images by solving a constrained total variation (TV) minimization problem for the interior projection data, which is assisted by the exterior projection data in the compressed sensing (CS) framework. For the interior image reconstruction assisted by the exterior projection data, we implemented the proposed method which enforces dual data fidelity terms and a TV term. The proposed method has effectively suppressed the bright-band artifacts around the ROI boundary and the streak artifacts in the ROI image. We expect the proposed method can be used for low-dose CT scans based on limited x-ray exposure to a small ROI in the human body.

50-300 keV X-ray Transmission Ratios for Lead, Steel and Concrete

  • Tae Hwan Kim;Kum Bae Kim;Geun Beom Kim;Dong Wook Kim;Sang Rok Kim;Sang Hyoun Choi
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.164-171
    • /
    • 2022
  • The number of facilities using radiation generators increases and related regulations are strengthened, the establishment of a shielding management and evaluation technology has become important. The characteristics of the radiation generator used in previous report differ from those of currently available high-frequency radiation generators. This study aimed to manufacture lead, iron, and concrete shielding materials for the re-verification of half-value layers, tenth-value layers, and attenuation curve. For a comparison of attenuation ratio, iron, lead, and concrete shields were manufactured in this study. The initial dose was measured without shielding materials, and doses measured under different types and thicknesses of shielding material were compared with the initial dose to calculate the transmission rate on 50-300 kVp X-ray. All the three shielding materials showed a tendency to require greater shielding thickness for higher energy. The attenuation graph showed an exponential shape as the thickness decreased and a straight line as the thickness increased. The difference between the measurement results and the previous study, except in extrapolated parts, may be due to the differences in the radiation generation characteristics between the generators used in the two studies. The attenuated graph measured in this study better reflects the characteristics of current radiation generators, which would be more effective for shield designing.

X-Rays through the Looking Glass: Mobile Imaging Dosimetry and Image Quality of Suspected COVID-19 Patients

  • Schelleman, Alexandra;Boyd, Chris
    • Journal of Radiation Protection and Research
    • /
    • 제46권3호
    • /
    • pp.120-126
    • /
    • 2021
  • Background: This paper aims to evaluate the clinical utility and radiation dosimetry, for the mobile X-ray imaging of patients with known or suspected infectious diseases, through the window of an isolation room. The suitability of this technique for imaging coronavirus disease 2019 (COVID-19) patients is of particular focus here, although it is expected to have equal relevance to many infectious respiratory disease outbreaks. Materials and Methods: Two exposure levels were examined, a "typical" mobile exposure of 100 kVp/1.6 mAs and a "high" exposure of 120 kVp/5 mAs. Exposures of an anthropomorphic phantom were made, with and without a glass window present in the beam. The resultant phantom images were provided to experienced radiographers for image quality evaluation, using a Likert scale to rate the anatomical structure visibility. Results and Discussion: The incident air kerma doubled using the high exposure technique, from 29.47 µGy to 67.82 µGy and scattered radiation inside and outside the room increased. Despite an increase in beam energy, high exposure technique images received higher image quality scores than images acquired using lower exposure settings. Conclusion: Increased scattered radiation was very low and can be further mitigated by ensuring surrounding staff are appropriately distanced from both the patient and X-ray tube. Although an increase in incident air kerma was observed, practical advantages in infection control and personal protective equipment conservation were identified. Sites are encouraged to consider the use of this technique where appropriate, following the completion of standard justification practices.

방사선이 흰쥐 갑상샘 소포곁세포에 미치는 영향에 대한 미세구조적 연구 (Electron Microscopic Study on the Parafollicular Cells of the Thyroid Gland of the Head and Neck-Irradiated Rats)

  • 김용식;양남길;안의태;고정식;박경호;김진국
    • Applied Microscopy
    • /
    • 제22권2호
    • /
    • pp.1-14
    • /
    • 1992
  • This experiment was performed to study the morphological responses of the parafollicular cells of rat following X-ray irradiation. Male rats were divided into normal and experimental groups. The head and neck region of the rat, under sodium thiopental anesthesia, was exposed to 3,000 rads or 6,000 rads of radiation in a single dose, respectively. The source was a Mitsubishi Linear Accelerator ML-4MV. The target to skin distance was 80 cm, and the dose rate was 200 rads/min. The rate of experimental groups were sacrificed on the 6th hour, 2nd and 6th day after X-ray irradiation. Pieces of the tissue taken from the thyroid gland were fixed in 2.5% glutaraldehyde-1.5% paraformaldehyde (0.1M Millonig's phosphate buffer, pH 7.3), and in 1% osmium tetroxide (0.1M Millonig's phosphate buffer, pH 7.3), and embedded in araldite mixture. The ultrathin sections stained with uranyl acetate and lead citrate were observed with JEM 100 CX-II electron microscope. The results were as follow; 1. Two types of the parafollicular cells, according to their electron densities, were found, i. e., light cells and dark cells. 2. Three types of the parafollicular cells, according to their sizes of secretory granules were found, i.e., small granule cells ($85nm{\pm}20.1;64{\sim}102nm$), medium granule cells ($120nm{\pm}26.5;77{\sim}179nm$), and large granule cells ($165nm{\pm}25.7;128{\sim}189nm$). 3. The differential ultrastructural changes of the cells according to their cell types, i.e., dark and light cell, or small, medium and large granule cells, were hardly observed in the time and dose range covered by this study. 4. The morphological changes of the parafollicular cells were not pronounced after exposure to 3,000 rads of X-ray. 5. Swollen cisternae of the granular endoplasmic reticulum and partial cytolysis were observed after exposure to 6,000 rads of X-ray. 6. Above results suggest that the parafollicular cells showed the alterations of mitochondrial and granular endoplasmic reticular swelling, and partial cytolysis, but only in doses of 6,000 rads.

  • PDF

MCNPX 시뮬레이션을 이용한 무납 방사선 차폐 시트 기반의 공간산란 저감화 평가 (Evaluating the Reduction of Spatial Scattering based on Lead-free Radiation Shielding Sheet using MCNPX Simulation)

  • 양승우;박금별;허예지;박지군
    • 한국방사선학회논문지
    • /
    • 제14권4호
    • /
    • pp.367-373
    • /
    • 2020
  • 물체와 X선의 상호작용로 발생하는 산란선으로 야기되는 공간 산란선량은 대부분이 저에너지 영역의 전자기파로 인체에 비교적 쉽게 흡수되어 방사선 피폭정도가 증가하게 된다. 이러한 공간 산란 선량은 방사선작업 종사자 및 환자의 방사선 피폭 정도 지표로도 사용되고 있으며 간접적으로 발생하는 공간 산란 선량을 줄여 피폭을 저감화하기 위한 방안의 필요성이 마련될 필요성이 있다. 이에 본 연구에서는 공간산란 선량을 저감화 방안으로 무납 방사선 차폐 시트를 제시하였고 가슴 X선 촬영검사를 기준으로 몬테카를로(MC; Monte Carlo) 시뮬레이션을 수행하여 거리 변화에 따른 갑상샘과 생식선 위치에서 흡수되는 산란선의 흡수선량을 산출하였고 실측치와 차폐율을 비교 평가하였다.

X-선 조사를 받은 흰쥐 망막의 색소상피세포와 기저복합층의 미세구조 (Fine Structure on the Pigment Epithelial Cell and the Bruch's Membrane of the Rat Retina after X-Irradiation)

  • 고정식;신기호;안의태;양남길;박경호;김진국
    • Applied Microscopy
    • /
    • 제23권2호
    • /
    • pp.11-26
    • /
    • 1993
  • This experiment was performed to study the morphological responses of the pigment epithelial cell and the Bruch's membrane of the retina of rat following X-ray irradiation. Male rats were divided into normal and experimental groups. The heads of the rats, under sodium thiopental anesthesia, were exposed to 3,000 rads or 6,000 rads of radiation in a single dose, respectively. The source was a Mitsubishi Linear Accelerator ML-4MV. The target to skin distance was 80cm, and the. dose rate was 200 rads/min. The experimental groups were sacrificed on the 6th hour, 2nd and 6th day after X-ray irradiation. Under anesthesia, 1% glutaraldehyde-1% paraformaldehyde solution(0.1M Millonig's phosphate buffer, pH 7.3) was perfused through the left ventricle and ascending aorta. Pieces of the tissue taken from the posterior region of the retina were fixed in 2.5% glutaraldehyde-1.5% paraformaldehyde(0.1M Millonig's phosphate buffer, pH 7.3) and 1% osmium tetroxide(0.1M Millonig's phosphate buffer, pH7.3), and embedded in araldite mixture. The ultrathin sections contrasted with uranyl acetate and lead citrate were observed with JEM 100 CX-II electron microscope. The results were as follow; 1. The morphological changes of the pigment epithelial cells were not pronounced after exposure to 3,000 rads of X-ray. But on the 6th hour after exposure to 6,000 rads of X-ray, bulging nuclear membrane protruding into the cytoplasm and nuclear chromatin clumped into numerous masses along the nuclear membrane were observed. At the 2nd and 6th day post-irradiation, partial cytolysis or necrosis were seen. 2. The thickness of the Bruch's membrane of the experimental groups were increased in the time and dose range covered by this study, and splitting or diffusing basal laminae of the choriocapillary layer were observed frequently in the experimental group. Above results suggest that large amount(6,000 rads) of head irradiation induce direct hazardous effects on the pigment epitherial cells and Bruch's membrane of the retina of the rat, but pigment epithelial cells are more radioresistant than Bruch's membrane.

  • PDF

Assessment of Radiation Dose from Radioactive Wedge Filters during High-Energy X-Ray Therapy

  • Back, Geum-mun;Park, Sung Ho;Kim, Tae-Hyung
    • 한국의학물리학회지:의학물리
    • /
    • 제28권2호
    • /
    • pp.45-48
    • /
    • 2017
  • This paper evaluated the amount of radiation generated by wedge filters during radiation therapy using a high-energy linear accelerator, and the dose to the worker during wedge replacement. After 10-MV photon beam was irradiated with wedge filter, the wedge was removed from the linear accelerator, and the dose rate and energy spectrum were measured. The initial measurement was approximately 1 uSv/h, and the radiation level was reduced to 0.3 uSv/h after 6 min. The effective half-life derived from the dose rate measurement was approximately 3.5 min, and the influence of AI-28 was about 53%. From the energy spectrum measurements, a peak of 1,799 keV was measured for AI-28, while the peak for Co-58 was not measured in the control room. The peaks for Au-106 and Cd-105 were found only measurement was done without wedge removement from the linear accelerator. The additional doses received by the radiation worker during wedge replacement were estimated to be 0.08-0.4 mSv per year.

LIGA 공정 중 PMMA 현상 과정의 모사 (Simulation of the PMMA development course in LIGA process)

  • 임종석;이선아;구양모
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2000년도 추계학술대회 논문집
    • /
    • pp.733-736
    • /
    • 2000
  • In the first step of the LIGA process a resist layer, typically PMMA(polymethylmethacrylate), is pattered by deep X-ray lithography. Then the exposed parts are dissolved by an organic developer. To describe the developer. To describe the development course the parameters influencing the development process was investigated. The developed depth is proportional to the square root of the development time which suggests that the development rate increases with increasing dose value and temperature. So the development course can be described by a phenomenological equation.

  • PDF