• Title/Summary/Keyword: X-ray dose

Search Result 945, Processing Time 0.03 seconds

Results of Radiotherapy for the Uterine Cervical Cancer (자궁경부암의 방사선치료성적)

  • Kim, Chul-Yong;Choi, Myung-Sun;Suh, Won-Hyuck
    • Radiation Oncology Journal
    • /
    • v.6 no.1
    • /
    • pp.63-73
    • /
    • 1988
  • One hundred fifty-four patients with the carcinoma of the uterine cervix were studied retrospectively to assess the result and impact of treatment at Department of Radiation Oncology, Korea University, Hae-Wha Hospital from Feb 1981 through Dec. 1986. Prior to radiotherapy, the patients were evaluated and staged by recommendation of FIGO including physical examination, pelvic examination, cystoscopy, rectosigmoidoscopy, chest X-ray, IVP. Ba enema. Also, an additional pelvic CT scan was obtained for some of the patients. The patients were treated by radiotherapy alone or adjuvant postoperative irradiation; in case of radiation therapy only, whole pelvic irradiation was given with Co-60 teletherapy unit via AP and PA parallel opposing fields or 4-oblique fields, 180 cGy per day, 5 days per week and intracavitary insertion was performed. In satges Ia, Ib, and IIa with small primary lesion, external irradiation was initially given to pelvis up to $2,000\~3,000\;cGy/2frac{1}{2}\;-3frac{1}{2}$ weeks and then intracavitary insertion was performed using Fletcher-Mini-Declos Applicator with cesium-137 cources and followed by external irradiation of $1,000\~2,000\;cGy/1frac{1}{2}\;-2frac{1}{2}$weeks via AP and PA parallel opposing fields with midline shield to spare of bladder and rectum. However, if the primary lesion is large, external irradiation was given without midline shield. More than stages IIb, the patients were treated by external beam irradiation up to 5,400cGy/30f for 6 weeks via 4-oblique portals and at the dose of 5,040cGy/28f the field was cut 5cm from the top margin for spare of small bowel, and followed by intracavitary irradiation, If there was residual tumor an additional dose of $900\~l,200cGy/5\~7f$ was given to parametrium and/or residual tumor area. Total dose of radiation to A and B-point were as follows; A-point; In early stages, Ia, Ib, IIa; $8,000\~9,000$ B-point $5,000\~6,000 cGy$ A-point; In advanced stages IIb, IIIa, IIIb; $9,000\~10,000$ B-point $60,000\~7,000cGy$ The results were obtained and as fellows; 1 The patients distribution according to FIGO staging system were stage Ia 6, Ib 27, IIa 28, IIb 54, IIIa 12, IIIb 18, and stage IVa 9. 2. Value of CT scan were demonstration of cervix tumor mass, parametrial and pelvic side wall tumor spread, pelvic and inguinal lymph nodes metastases, and hydronephrosis. Three dimensional quantitative demonstration of tumor volume is also important in planning radiation therapy. Another advantage of CT scan was detection of recurrent tumor after radiation or surgery. 3. Local control rate of tumor according to the size was $91.3\%$ for less than 5cm in size and $44.6\%$ in tumor over 5cm (p<0.0068). 4. Thirty out of 50 recurrent sites has locoregional failures and 17 cases has distant metastases. And the para-aortic lymph nodes were the most common site for distant metastases. 5. The most common complication was temporal rectal bleeding which was controlled most by conservative management. However, 4 patients required for endoscopic cauterization. 6. The 5-year survival rates showed; stage la and Ib $95\%,\;stage\;IIa\;81\%\;stage\;lIb\;67\%,\;stage\;IIIa\;37.7\%,\;stage\;IIIb\;23\%$ and 3-year survival rate of stage IVa showed $11.6%$, retrospectively.

  • PDF

A Study on the Utilization of Diagnostic Equipments and Patient Dose for Diagnostic Radiological Procedures in Korea (진단방사선영역에서 방사선장치의 이용실태 및 환자피폭선량에 관한 조사연구)

  • Kim Youhyun;Choi Jonghak;Kim Sungsoo;Lee Chanhyeup;Cho Pyongkon;Lee Youngbae;Kim Chelmin
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.10-15
    • /
    • 2005
  • IAEA's guidance levels have been provided for western people to the end. Guidance levels lower than the IAEA'S will be necessary in view of Korean people's proportions. Therefore, we need to develope the standard doses for Korean people. And we conducted a nationwide survey of patient dose from x-ray examinations in Korea. In this study, the 278 institutions were selected from Members Book of Korean Hospital Association. The valid response rate was approximately 57.9%. Doses were calculated from the questionnaires by NDD method. We obtained the results were as follows; 1) General radiographic equipments were distributed for 42.0%, fluoroscopic equipments 29.4%, dental equipments 13.2%, CT units 8.1 % and mamographic units 7.2%. 2) According to classification by rectification, three-phase equipments were 29.9%, inverter-type generators 29.5%, single-phase equipments 25.5%, constant voltage units 9.0% and unknown units 6.0%. 3) According to classification by receptor system, film-screen types were 46.8%, CR types 26.8%, DR types 17.7% and unknown types 8.9%. 4) The number of examinations were chest 49.2%, spine 16.8% and abdomen 12.7%. 5) Patient doses were head AP 3.44 mGy, abdomen AP 4.25 mGy and chest PA 0.39 mGy.

  • PDF

The Role of Radiotherapy in the Treatment of Extrahepatic Bile Duct Carcinoma (간외담도종양에서 방사선치료의 역할)

  • Shin Hyun Soo;Kim Gwi Eon;Lee Hyung Sik;Suh Chang Ok;Loh John JK;Lee Jong Tae
    • Radiation Oncology Journal
    • /
    • v.9 no.2
    • /
    • pp.253-263
    • /
    • 1991
  • Twenty-seven patients with unresectable extrahepatic bile duct carcinoma (n=21) or with microscopic evidence of tumor rest after aggressive surgery for extrahepatic bile duct carcinoma (n=6) between 1985 and 1990 were given radiotherapy consisting intentionally external radiotherapy and/or intraluminal therapy using Gamma-Med 12i (192-Ir) high dose rate (HDR) remote control afterloading system following bile drainage procedures and Gianturco stent insertion. The objectives of this study has been to assess the feasibility and effects on survival of a combination of external radiotherapy and brachytherapy with which we hope to achieve optimal loco-regional control for patients with unresectable extrahepatic bile duct tumors. Sixteen patients were men and eleven were women, and the mean age was 58 years (34-70). 10MV X-ray was used for radiation therapy, with the total dose ranging from 45 Gy to 55 Gy, and intraluminal brachytherapy performed after external radiotherapy, with the dose of total 15 Gy. The minimum follow up was 12 months. Failure were predominantly local-regional, without distant failure. Median survival was 10 months; 2-year actuarial survival rates was $21\%$. Median survival for common hepatic duct (CHD) cancer was 9 months; for common bile duct (CBD) cancer, was 16 months. And median survival for incomplete surgery/external radiotherapy group and external/intraluminal radiotherapy group was 10 months; for external radiotherapy alone group, was 6 months. Use of chemotherapy and/or hyperthermia were not affected in survival. Therefore, our result is that the survival rates in the group of external/intraluminal radiotherapy were comparable with ones in the group of incomplete resection/external radiotherapy, and so we believe that the aggressive local and regional radiotherapy can improve the quality of life and the survival length.

  • PDF

THE EFFECTS OF IRRADIATION ON THE MANDIBULAR BONE OF RATS ON THE LOW CALCIUM DIET (방사선조사가 저칼슘식이 백서의 하악골에 미치는 영향에 관한 실험적 연구)

  • Hwang Eui-Hwan;Lee Sang-Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.2
    • /
    • pp.241-252
    • /
    • 1992
  • The purpose of this study was to investigate the changes of morphology and structure of bone tissue in the irradiated mandibular bone in rats which were fed a low calcium diet. In order to carry out this experimant, 64 seven-week old Sprague-Dawley strain rats weighing about 150gms were selected and equally divided into one experimental group of 32 rats and one control group with the remainder. The experimental group and the control group were then subdivided into two groups when the rats reached ten-week old, 16 were assigned rats for each subdivided group, exposed to irradiation. The two irradiation groups received a single dose of 20 Gy in the jaws area only and irradiated with a cobalt-60 teletherapy unit. The rats in the control and experimental groups were serially terminated by fours on the 3rd, the 7th, the 14th, and the 21st day after irradiation. Following termination, both sides of the dead rats mandibular bodies were removed and fixed with 10% neutral formalin. One side of the mandibular body was radiographed with a soft X-ray apparatus. Thereafter, the obtained microradiographs were observed by a light microscope. The remaining side of the mandibular bone was further decalcified and embedded in paraffin as using the general method. The specimen sectioned and stained with hematoxylin and eosin, and Rabit Anti-Human Tumor Necrosis Factor-a, observed by a light microscope. The obtained results were as follows: 1. Microradiogram revealed that thinning of the cortex and a decrease in the trabecula of the interradicular bone and mandibular body were observed and noted from the start to finish throughout the experiment in the non-irradiated rats on the low calcium diet rather than in the non-irradiated rats on the normal diet. In microscopic observations, there were marked osteolytic changes in the center of the bone marrow. 2. Microradiogram revealed that thinning of the cortex and a decrease in the trabecula of interradicular bone and mandibular body were more marked after 7 days in the irradiated rats on the low calcium diet rather than in the non-irradiated rats on the low clacium diet. In microscopic observations, osteoblasts were decreased markedly after 7 days, and a few osteoclasts were observed. 3. Microradiogram revealed that thinning of the cortex and a decrease in trabecula of interradicular bone and the mandibular body were more marked from the strart to finish troughout the experiment in the irradiated rats on the low calcium diet rather than in the irradiated rats on the normal diet. In microscopic observations, there were no osteolytic changes noted in the irradiated rats on the normal diet. 4. In immunocytochemical findings, a few bone marrow cells including Tumor Necrosis Factor were observed in the irradiated rats on the normal diet, but was not observed in the rats on the low calcium diet.

  • PDF

Effect of Photodynamic Therapy in Lung Cancer (폐암에서 광역동치료술의 효과)

  • Yoon, Sung Ho;Han, Kyung Taek;Kim, Gyung Nam;Lee, Seung Il
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.4
    • /
    • pp.358-363
    • /
    • 2004
  • Background : Photodynamic therapy (PDT) involves the use of photosensitizing agents for treatment of malignant disease. PDT is approved by the U.S. Food and Drug Administration for the endobronchial microinvasive nonsmall cell lung cancer and for palliation in patients with obstructing tumors. We report our experience and results of PDT in lung cancer. Method : Ten patients with lung cancer who were diagnosed in Chosun university hospital by histologic confirm through bronchoscopy were included between August 2002 and May 2003. The photosensitizer (Photogem$^{(R)}$, Lomonosov institute of Fine Chemical, Russia/dose 2.0 mg/kg body weight) was injected 48 hours prior to the PDT session. For PDT with the photosensitizer (Photogem$^{(R)}$), Diode LASER system (Biolitec Inc., Germany, wavelength; 633nm) were used. PDTs were done at 48-72 hours after photogem injection. Follow up bronchoscopy and chest X-ray or thorax computerized tomography were done for evaluate PDT response. Results : 9 of 10 patients with endobronchial obstruction showed partial remission with bronchus opening after PDT. Direct reaction of the tumor to PDT was similar in despite of its localization. It was as follows; edema, hyperemia, in-situ bleeding, fibrin film occurrence. Any other complications such as sunburns of skin, inflammation within the PDT zone were not occurred by the end of the fourth week. Conclusion : In the advanced endobronchial disease, PDT has been shown to be useful in treating endobronchial tumors that are causing clinically significant dyspnea or are likely to progress and lead to further clinical complications, such as postobstructive pneumonia.

A Case of Goodpasture's Syndrome Combined with Crohn's Disease (크론씨 병에 동반된 Goodpasture 증후군 1예)

  • Kim, Ji-Yon;Bae, Jun-Yong;Jung, Eun-Jung;Kim, Yang-Ki;Lee, Young Mok;Kim, Ki-Up;Uh, Soo-taek;Hwang, Jung-Hwa;Jin, So-Young;Lee, Dong-Wha
    • Tuberculosis and Respiratory Diseases
    • /
    • v.61 no.4
    • /
    • pp.384-388
    • /
    • 2006
  • A 29-year-old male patient was admitted due to his general weakness and poor oral intake for several months. He was diagnosed as having Crohn disease 16 years ago and total colectomy was performed 10 years ago. On the 3rd day after admission, gross hematuria and sudden hemoptysis combined with diffuse infiltration were noted on chest X-ray. His symptoms and the diffusely increased lung opacities improved with administering high-dose steroid therapy. Later, anti-GBM antibody was found to be positive on the laboratory findings. We report here on a rare case of Goodpsture syndrome combined with prolonged Crohn disease along with a review of literature.

고감도 형광판을 이용한 실시간 IMRT 선량 분석 가능성 연구

  • 고영은;이병용;안승도;이상욱;김종훈;신성수;최은경
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2003.09a
    • /
    • pp.36-36
    • /
    • 2003
  • 목적 : 고감도 형광판과 필름을 이용하여 실시간으로 선량을 측정하여 IMRT 선량분포를 검증하는데 사용하는 가능성을 알아보고자 하였다. 대상 및 방법 : 본 연구에서 개발한 물팬텀은 지름 25cm 아크릴 원통과 원통의 중앙부분에 삽입되는 고감도 형광판으로 구성되어 있다. 이를 사용하여 dose linearity correction factor를 구하기 위해 dmax 지점에서 6MV x-ray를 고감도형광판에 조사하여 blurring correction factor를 구하였다. CCD를 이용하여 고감도 형광판에서 나오는 영상을 수집하였다. 고감도 형광판에서 수집한 영상의 x축 profile은 RTP에서 얻은 profile과 비교하였고, 이온전리함으로 scanning한 데이터를 이용하여 고감도 형광판과 물에서 빛에 의한 산란선 때문에 발생하는 blurring effect를 교정하였다. 여기서 계산된 blurring effect factor를 고감도 형광판에서 수집된 영상에 적용하였다. 결과 : CCD 카메라는 형광판의 전 영역을 감지할 수 있고, 조사시간은 형광판의 중첩된 영상의 선량에 비례하였다. 물팬텀에서 형광판의 blurring effect 는 가우시안 분포로 표현할 수 있었다. 또한 Deconvolution kernel은 원통 팬텀에서 지름 $\pm$5cm 이내의 범위에 위치하였고, 따라서 형광판 영상으로부터의 실제 선량분 포를 뽑아낼 수 있었다. RTP 에서 계산된 선량분포와 blurring correction factor로 교정한 후 중첩시켜 얻은 고감도 형광판 영상의 선량분포는 일치하였다. 결론 : 정기적인 IMRT 선량 검증에 대한 실시간 선량측정 방법이 개발되었다. 고감도 형광판 영상과 CCD 카메라를 사용한 물팬텀으로, IMRT 치료계획에 대한 선량분포를 검증할 수 있는 가능성을 보였다.비의 회전에 의한 오차 보정, 필름의 광학적 밀도에 관한 보정 등 여러 가지 계통적 오차들에 대한 보정들이 선량분포 확인과정의 이해와 그 기준마련에 도움이 되겠지만 우리가 다룬 원점 불일치에 비해서 상대적으로 무시할 수 있었다. 마지막으로 선량분포 확인의 최종목표인 3 차원 선량분포 확인의 실제 적용을 위한 연구가 최적화 알고리듬을 이용하여 실험 중에 있다.\times$5cm, 10$\times$10cm, 15$\times$l5cm, 20$\times$20cm인 경우, 측정하여 얻은 PSF가 0.8%, 0.2%, 0.4%, 0.2%로 약간 높지만, 두 값은 매우 유사한 것으로 나타났다. 그리고, 기존의 BSF를 이용해 구한 TAR과 BJR 25에서 권고하는 PSF를 이용해 구한 TAR을 비교한 결과 field size 에 따라 약 1%-1.5% 정도로 BSF를 이용하여 구한 TAR보다 PSF를 이용하여 구한 TAR이 1.3% 정도 높게 나타났지만, 이것은 두 값의 절대적인 차이일 뿐, 실제로는 PSF를 이용하여 구한 TAR이 측정해서 구한 TAR과는 매우 유사한 값을 보여주고 있다. 결론 : 기존의 BSF를 이용해 구한 TAR과 PSF를 이용해 구한 TAR을 비교하였을 때, 약 1.3% 정도 높게 내고 있지만, 기존의 TAR보다는 PSF를 이용해 구한 TAR이 BJR 25와 잘 일치하고 있으므로 Co-60 원격치료용 방사선 조사장치를 사용할 경우 BSF보다는 PSF를 사용하는 것이 타당한 것으로 사료된다.tokines의 변화는 비록 통계학적인 차이는 없지만 비타민 C를 사용한 환자의 cytokines이 모두 사용하지 않은 환자에 비해 감소하였음을 보였다. 비타민 C는 부작용이 거의 없는 안전한 약으로서 말기 암 환자에서 비타민 C사용은 임상 증상을 호전시키는 데 도움

  • PDF

Photostimulated Luminescence and Photoluminescence of SrCl2:Eu2+ Phosphors (SrCl2:Eu2+ 형광체의 광발광 및 광자극발광 특성)

  • Doh, Sih-Hong;Seo, Hyo-Jin;Kim, Young-Kook;Kim, Do-Sung;Kim, Sung-Hwan;Kim, Chan-Jung;Lee, Byung-Hwa;Kim, Wan;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.319-326
    • /
    • 2002
  • $SrCl_2:Eu^{2+}$ phosphors were prepared by the solid phase reaction method, and their photostimulated luminescence(PSL) and photoluminescence(PL) characteristics were investigated. The PSL and PL peak of the $SrCl_2:Eu^{2+}$ phosphors are due to the $5d{\rightarrow}4f$ transition of $Eu^{2+}$ ions in phosphors. The PSL and PL spectrum obtained by the 355nm excitation was observed in $380{\sim}440\;nm$ region with the peak at 407 nm. The dose response of the PSL phosphors were linear within $2.5\;mGy{\sim}200\;mGy$ of 100 kV X-ray. The fading of the phosphors at room temperature was approximately 60% after 20 min.

Testing and Analysis of Tube Voltage and Tube Current in The Radiation Generator for Mammography (유방촬영용 방사선발생장치의 관전압과 관전류 시험 분석)

  • Jung, Hong-Ryang;Hong, Dong-Hee;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Breast shooting performance management and quality control of the generator is applied to the amount of current IEC(International Electrotechnical Commission) 60601-2-45 tube voltage and tube current are based on standards that were proposed in the analysis of the test results were as follows. Tube voltage according to the value of the standard deviation by year of manufacture from 2001 to 2010 as a 42-3.15 showed the most significant, according to the year of manufacture by tube amperage value of the standard deviation to 6.38 in the pre-2000 showed the most significant, manufactured after 2011 the standard deviation of the devices, the PAE(Percent Average Error) was relatively low. This latest generation device was manufactured in the breast of the tube voltage and tube diagnosed shooting the correct amount of current to maintain the performance that can be seen. The results of this study as the basis for radiography diagnosed breast caused by using the device's performance and maintain quality control, so the current Food and Drug Administration "about the safety of diagnostic radiation generator rule" specified in the test cycle during three years of self-inspection radiation on a radiation generating device ensure safety and performance of the device using a coherent X-ray(constancy) by two ultimately able to keep the radiation dose to the public to reduce the expected effect is expected.

Rate of Transformation and Normal Range about Cardiac Size and Cardiothoracic Ratio According to Patient Position and Age at Chest Radiography of Korean Adult Man (한국인 성인 남성의 흉부 방사선영상에서 자세와 연령에 따른 심장 크기 및 심흉비의 정상 범위와 변환율)

  • Joo, Young-Cheol;Lim, Cheong-Hwan;Kim, Yun-Min;Jung, Hong-Ryang;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.179-186
    • /
    • 2017
  • Purpose of this study is present the normal range of cardiac size and cardiothoracic ratio according to patient position(chest PA and AP) and age of Korean adult male on digital chest X - ray, And to propose a mutually compatible conversion rate. 1,024 males were eligible for this study, among 1,300 normal chest patients who underwent chest PA and low-dose CT examinations on the same day at the 'S' Hospital Health Examination Center in Seoul From January to December 2014. CS and CTR were measured by Danzer (1919). The mean difference between CS and CTR was statistically significant (p<0.01) in Chest PA (CS 135.48 mm, CTR 43.99%) and Chest AP image (CS 155.96 mm, CTR 51.75%). There was no statistically significant difference between left and right heart in chest PA and AP images (p>0.05). CS showed statistically significant difference between Chest PA (p>0. 05) and Chest AP (p<0.05). The thorax size and CTR were statistically significant (p<0.01) in both age and chest PA and AP. Result of this study, On Chest AP image CS was magnified 15%, CTR was magnified 17% compare with Chest PA image. CS and CTR were about 10% difference by changing posture at all ages.