• Title/Summary/Keyword: X-ray diagnosis

Search Result 793, Processing Time 0.037 seconds

A Study on the Distribution of X-ray according to the Thickness of Soft Tissue in Radiography (X선촬영시(線撮影時) 연부조직(軟部組織) 두께에 따른 선량분포(線量分布)에 관(關)한 연구(硏究))

  • Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.11 no.2
    • /
    • pp.3-15
    • /
    • 1988
  • When X-rays were projected into a patient, there occured the phenomena such as penetration, absorption and scattering etc. The penetrating rays were recorded on films as X-ray image used for diagnosis but scattered rays caused the radiation hazard both to the patient, specialist and technicians. The soft tissue includes many organs which are sensitive to the radiation and in may occupy $40{\sim}50%$ of body weight. Therefore X-rays should be carefully projected to the patient and it is strongly recommended to analyse the distribution of X-rays, when ever the patient is exposed to X-rays. In this study, the distribution of X-ray according to the thickness, the radiation field and the tube voltages (kVp) in soft tissue, the following results were obtained: 1. Total transmitted rays which kept the step with X-ray tube voltage (kVp) increased in proportion to the increasing of X-ray tube voltage. 2. The scattered ray rate in the total transmitted ray was not significantly found with X-ray tube voltage. 3. The affecting factors of the scattered ray rate in total transmitted ray were shown through the radiation field and the thickness. 4. The dose of scattered ray by the angle was observed more in direction of primary ray ($0^{\circ}$) and back scattering ($160^{\circ}$) than in direction of $90^{\circ}$. 5. The more the distance from phantom to the patient should be less distribution of scattered ray.

  • PDF

Current Topics on Quality Assurance of X-ray Diagnosis in Japan

  • Katoh, Tuguhisa;Imamura, Keiko;Matumoto, Toru
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.13-16
    • /
    • 2002
  • Recent topics on quality assurance (QA) of X-ray diagnosis in Japan were reported in this presentation. These were related to mass screening mammography (MMG), lung screening CT (LSCT), skin injury caused by interventional radiology (IVR) and traceable system of dosimeters for x-ray diagnosis. In these successful stories, the author would like to stress the cooperation of all the medical am: clinical staff including medical doctors, radiological technologists, medical physicists, manufacturers of medical devices and others.

  • PDF

Automated Detection of Pulmonary Nodules in Chest X-ray Radiography Using Genetic Algorithm (흉부 X-ray 영상에서 유전자 알고리즘을 이용한 폐 결절 자동 추출)

  • 류지연;이경일;장정란;오명진;이배호
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2002.10d
    • /
    • pp.553-555
    • /
    • 2002
  • 컴퓨터지원진단(Computer Aided Diagnosis; CAD) 시스템은 방사선 의사들이 흉부 X-ray 영상에서 결절을 탐지하는데 있어 실제적으로 발생할 수 있는 오진율을 줄이고, 폐 결절이 존재하는 폐야에서 결절의 존재 유무를 판단하여 검출을 표시함으로써 진단율을 개선시킬 수 있도록 하였다. 본 논문은 흉부 X-ray 영상에서의 폐 결절을 추출하는데 유전자 알고리즘(Genetic Algorithm)을 이용한 템플릿 매칭(Template Matching) 방법을 제안한다. 제안한 방법은 흉부 X-ray 영상에 존재하는 결절과 레퍼런스 이미지를 매칭시켜 적합도를 계산한 후, 그 값을 통하여 수치가 낮은 개체를 선택하여 높은 개체와 교차시킨다. 그리고 레퍼런스 이미지는 결절이 존재하는 환자 X-ray 영상에서 샘플 노듈을 추출한 후 가우시안 분포를 갖는 512개의 레퍼런스 이미지를 생성하였다. 본 논문에서 사용된 영상은 결절 50개, 비결절 30개와 흉부 X-ray 영상에서 육안으로 판별이 가능한 결절 영상을 20개를 포함하여 총 100개 영상을 사용하였다. 실험 결과 83%의 결절을 자동 추출 하였으며, 가장 적절한 레퍼런스 이미지를 발견하고 이를 흉부영상에 매칭시켜 정확한 결절의 위치를 확인하였다.

  • PDF

Microcalcification Extraction by Wavelet Transform and Automatic Thresholding (웨이브렛 변환과 자동적인 임계치 설정에 의한 미세 석회화 검출)

  • Won, Chul-Ho;Seo, Yong-Su;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.4
    • /
    • pp.482-491
    • /
    • 2005
  • In this paper, we proposed the microcalcification detection algorithm which is based on wavelet transform and automatic thresholding method in the X-ray mammographic images. Digital X-ray imaging system is essential equipment in the field diagnosis and is widely used in the various fields such as chest, fracture of a bone, and dental correction. Especially, digital X-ray mammographic imaging is known as the most important method to diagnose the breast cancer, many researches to develop the imaging system are processing in country. In this paper, we proposed a microcalcifications detection algorithm necessary in the early phase of breast cancer diagnosis and showed that a algorithm could effectively detect microcalfication and could aid diagnosis-radiologist.

  • PDF

Systematic Review of the Diagnosis of Pelvic Deviation for Chuna Manual Therapy (추나치료에 적용된 골반변위 진단법에 대한 체계적 문헌고찰)

  • Lee, Jun-Seok;Park, Kyeong-Won;Kim, Hyun-Tae;Park, Sun-Young;Shin, Byung-Cheul
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.32 no.2
    • /
    • pp.83-94
    • /
    • 2022
  • Objectives This systematic review aimed to analyze research about pelvic deviation diagnosis for Chuna manual therapy (CMT) and to review the diagnosis methods, indices, and results of diagnosis. Methods Ten electronic databases were systematically searched up to January 4th 2022. Clinical studies and reviews containing pelvic deviation diagnosis for CMT or using CMT as a treatment of pelvic deviation were selected and evaluated. CMT diagnosis in clinical studies and reviews were isolated and analyzed by 2 independent reviewers. Results Thirteen clinical studies and three reviews were included in the evaluation. X-ray analysis and manual testing were the two main methods used in CMT diagnosis of pelvic deviation. For manual testing in clinical studies, leg length insufficiency testing was the most frequently used measurement index and the most common diagnostic results were anterior and posterior rotation. In the X-ray analysis, Obturator foramen and femur head line were the most frequently used measurement index and the most common diagnostic results were anterior rotation and posterior rotation. Conclusions The systematic review found that manual testing and X-ray analysis were mainly used for the diagnosis of pelvic deviation in CMT among clincial and review articles. As there was little research about diagnosing pelvic deviation in CMT and any existing research presented only low standards of evidence, further research should be updated with using a more standardized approach.

A Clinical Study on Diagnosis of the patients with Scoliosis by D.I.T.I. (D.I.T.I.를 이용한 척추측만증 진단의 임상적 고찰)

  • Bae, Eun-jung;Seo, Jung-chul;Lim, Sung-chyl;Han, Sang-won
    • Journal of Acupuncture Research
    • /
    • v.21 no.1
    • /
    • pp.51-58
    • /
    • 2004
  • Objective: The purpose of this study is to report that D.I.T.I. can be used for diagnosis of scoliosis. Methods: We measured the posterior trunk surface of the patients with shoulder pain or low back pain. They were ruled out as scoliosis by D.I.T.I. and compared with X-ray finding of T L-spine Ap views and calculated scoliosis angle. Results: In according to the spinoprocess curve in D.I.T.I. we could rule out as scoliosis. Thermal difference of left and right segmental areas of the patients was showed. Scoliosis angle of the patients ranged from $4^{\circ}$ to $11^{\circ}$ in X-ray finding. Conclusions: The results suggest that D.I.T.I. can explain physiologic and functional abnormalities than X-ray, in diagnosis of scoliosis. But further studies are required to for the diagnosis of scoliosis by analysing D.I.T.I..

  • PDF

A Tuberculosis Detection Method Using Attention and Sparse R-CNN

  • Xu, Xuebin;Zhang, Jiada;Cheng, Xiaorui;Lu, Longbin;Zhao, Yuqing;Xu, Zongyu;Gu, Zhuangzhuang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.7
    • /
    • pp.2131-2153
    • /
    • 2022
  • To achieve accurate detection of tuberculosis (TB) areas in chest radiographs, we design a chest X-ray TB area detection algorithm. The algorithm consists of two stages: the chest X-ray TB classification network (CXTCNet) and the chest X-ray TB area detection network (CXTDNet). CXTCNet is used to judge the presence or absence of TB areas in chest X-ray images, thereby excluding the influence of other lung diseases on the detection of TB areas. It can reduce false positives in the detection network and improve the accuracy of detection results. In CXTCNet, we propose a channel attention mechanism (CAM) module and combine it with DenseNet. This module enables the network to learn more spatial and channel features information about chest X-ray images, thereby improving network performance. CXTDNet is a design based on a sparse object detection algorithm (Sparse R-CNN). A group of fixed learnable proposal boxes and learnable proposal features are using for classification and location. The predictions of the algorithm are output directly without non-maximal suppression post-processing. Furthermore, we use CLAHE to reduce image noise and improve image quality for data preprocessing. Experiments on dataset TBX11K show that the accuracy of the proposed CXTCNet is up to 99.10%, which is better than most current TB classification algorithms. Finally, our proposed chest X-ray TB detection algorithm could achieve AP of 45.35% and AP50 of 74.20%. We also establish a chest X-ray TB dataset with 304 sheets. And experiments on this dataset showed that the accuracy of the diagnosis was comparable to that of radiologists. We hope that our proposed algorithm and established dataset will advance the field of TB detection.

The Importance of Positioning in General X-ray Examination: Based on Chest PA X-ray (일반엑스선 검사 시 위치 잡이의 중요성: 흉부엑스선 검사 중심으로)

  • Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.249-254
    • /
    • 2022
  • The purpose of this study was to examine the importance of proper positioning in chest PA X-ray examination. As a study method, this author searched for and analyzed materials related to chest PA X-ray examination from theses and books that had been published previously to understand the importance of proper positioning in chest PA X-ray examination. Generally, one of the examinations frequently done in most of the hospitals is chest PA X-ray examination. Also, in any kinds of X-ray examination, proper positioning is the most fundamental and definite way to provide accurate information about the patient. Poor positioning in chest PA X-ray examination may jeopardize the diagnosis and treatment, increase social cost due to examination needed to be done additionally, and generate additional radiation exposure unnecessarily above all. In conclusion, it is expected that proper positioning in chest PA X-ray examination will exert positive effects such as the provision of accurate information about the patient, prevention of misdiagnosis, reduction in social cost, and lastly decrease in radiation exposure.

Analysis of efficiency of X-ray equipment for medical service (의료용 X-ray 기기의 성능평가)

  • Kim, Tae-Gon;Kim, Toung-Pyo;Lee, Ho-Sic;Park, Yong-Pil;Cheon, Min-Woo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.426-426
    • /
    • 2009
  • Diagnostic X-ray system is general and basic medical equipment to be used in mostly medical organizations, but being bombed of radioactivity is a big weak point when irradiates a X-ray to the human body so that ICRP restricted the radiation exposure tolerance of the human body. In order to reduce being bombed, the many research and development is now advanced. A lots of diagnostic X-ray machines have currently used due to the increase of occurrence efficiency of X-ray and precisely the output control by using the inverter which is a high speed switching semiconductors. For getting the confidence of the X-ray machine, the same radiation occurrence, same evaluation, and same irradiation condition are necessary when evaluates X-ray irradiation. It is the most important part for the accuracy of the test result and the patient safety. This paper has produced the high voltage occurrence system of full-wave rectification method by using the LC resonance inverter, and evaluated the irradiation reproducibility in order to use it in diagnosis of the patient.

  • PDF

Design of High Frequency Resonant Inverter Type X-Ray Generator (고주파 공진형 인버터식 X선 발생장치의 설계)

  • Lee, Seong-Gil;Park, Su-Gang;Baek, Hyeong-Rae;Jeong, Su-Bok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.1
    • /
    • pp.34-39
    • /
    • 2002
  • Most X-ray generator had been used do rectifier type transformer high tension generator which is supplied in a clinical diagnosis. But it is difficult to miniaturize and become light weight. Also, because the ripple rate of tube voltage is high, X-ray generating efficiency is very low. Therefore, it is supplied gradually from abroad being developed high tension generator for inverter type X-ray generator which use semi-conductor switching element for electric power that have high speed switching ability to solved these problem. But, semi-conductor element of big capacity are used by X-ray tube's big consumption power and diffusion is difficult in the small size hospital because production cost is ascending by doing digital control through DSP and product price becomes expensive. Therefore, in this paper, design and manufactured CR type voltage divider for feedback control of tube voltage of high frequency resonance type inverter and high tension transformer for high frequency to apply economical diffusion type X-ray generator which have wide output voltage and load extent. It is Proved do X-ray generator and stability of X-ray tube's output characteristics through an experiment.