• Title/Summary/Keyword: X-ray analysis

Search Result 4,839, Processing Time 0.038 seconds

Evaluation Method of Rock Characteristics using X-ray CT images (X-ray CT 이미지를 이용한 암석의 특성 평가 방안)

  • Kim, Kwang Yeom;Yun, Tae Sup
    • Tunnel and Underground Space
    • /
    • v.29 no.6
    • /
    • pp.542-557
    • /
    • 2019
  • The behavior of rock mass is influenced by its microscopic feature of internal structure generating from forming and metamorphic process. This study investigated a new methodology for characterization of rock based on the X-ray CT (computed tomography) images reflecting the spatial distribution characteristics of internal constituent materials. The X-ray image based analysis is capable of quantification of heterogeneity and anisotropy of rock fabric, size distribution and shape parameter analysis of rock mineral grains, fluid flow simulation based on pore geometry image and roughness evaluation of unexposed joint surface which are hardly acquired by conventional rock testing methods.

Analysis of Rolling Contact fatigue for PM-High Speed Steel by X-ray Diffraction (X선회절에 의한 분말 고속도공구강의 구름접촉피로 해석)

  • 이한영;노정균;배종수;김용진
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.44-49
    • /
    • 2000
  • Recently, PM-high speed steel(PM-HSS) has reportedly been a good alternative material for rolling mill because of its superior peformance to conventional HSS. This paper has been aimed to investigate the possibility for application to rolling contact element for PM-HSS by X-ray diffraction technique. The X-ray elastic constant for PM-HSS has been found by X-ray diffraction during the four-point bending test. Residual stress and half-value breadth on the contact surface during rolling contact fatigue process by X-ray diffraction have also been measured. The result of this study shows that the application of X-ray diffraction technique to PM-HSS could be as possible alternative material as conventional HSS. Half-value breadth on rolling contact surface by X-ray diffraction is not changed during rolling contact fatigue process. On the other hand, the residual stress is changed. This suggests that dislocation reaction has been hardly occurred in rolling contact, depending on supersaturated carbon in PM-HSS.

  • PDF

The Measurement and Analysis by Free Space Scatter Dose Distribution of Diagnostic Radiology Mobile Examination Area (영상의학과 이동검사 영역의 공간선량 분포에 대한 측정 및 분석)

  • Kim, Sung-Kyu;Son, Sang-Hyuk
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.5-13
    • /
    • 2009
  • There are several reasons to take X-ray in case of inpatients. Some of them who cannot ambulate or have any risk if move are taken portable X-ray at their wards. Usually, in this case, many other people-patients unneeded X-ray test, family, hospital workers etc-are indirectly exposed to X-ray by scatter ray. For that reason I try to be aware of free space scatter dose accurately and make the point at issue of portable X-ray better in this study. kVp dose meter is used for efficiency management of portable X-ray equipment. Mobile X-ray equipment, ionization chamber, electrometer, solid water phantom are used for measuring of free space scatter dose. First of all the same surroundings condition is made as taken real portable X-ray, inquired amount of X-ray both chest AP and abdomen AP most frequently examined and measured scatter ray distribution of two tests individually changing distance. In the result of measuring horizontal distribution with condition of chest AP it is found that the mAs is decreased as law of distance reverse square but no showed mAs change according to direction. Vertical distribution showed the mAs slightly higher than horizontal distribution but it isnt found out statistical characteristic. In abdomen AP, compare with chest AP, free space scatter dose is as higher as five-hundred times and horizontal, vertical distribution are quite similar to chest AP in result. In portable X-ray test, in order to reduce the secondary exposure by free space scatter dose first, cut down unnecessary portable order the second, set up the specific area at individual ward for the test the third, when moving to a ward for the X-ray test prepare a portable shielding screen. The last, expose about 2m apart from patients if unable to do above three ways.

  • PDF

Comparison of Quantitative Analysis of Radioactive Corrosion Products Using an EPMA and X-ray Image Mapping

  • Jung, Yang Hong;Choo, Young Sun
    • Corrosion Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.231-238
    • /
    • 2020
  • Radioactive corrosion product specimens were analyzed using an electron probe microanalyzer (EPMA) and X-ray image mapping. It is difficult to analyze the composition of radioactive corrosion products using an EPMA due to the size and rough shape of the surfaces. It is particularly challenging to analyze the composition of radioactive corrosion products in the form of piled up, small grains. However, useful results can be derived by applying a semi-quantitative analysis method using an EPMA with X-ray images. A standard-less, semi-quantitative method for wavelength dispersive spectrometry. EPMA analysis was developed with the objective of simplifying the analytical procedure required. In this study, we verified the reasonable theory of semi-quantitative analysis and observed the semi-quantitative results using a sample with a good surface condition. Based on the validated results, we analyzed highly rough-surface radioactive corrosion products and assessed their composition. Finally, the usefulness of the semi-quantitative analysis was reviewed by verifying the results of the analysis of radioactive corrosion products collected from spent nuclear fuel rods.

The Propriety of Portable Digital X-RAY Equipment for Emergency Medical Services (델파이 기법을 이용한 응급의료에서의 휴대용 디지털 X-ray 발생장치의 적절성)

  • Cho, Dong-Heon;Gu, Kyung-Wan;Yang, Hae-Sool;Jo, Jean-Man;Han, Man-Seok;Lee, Mi-Ok
    • The Korean Journal of Emergency Medical Services
    • /
    • v.9 no.1
    • /
    • pp.15-23
    • /
    • 2005
  • The purpose of this study is to analyze the propriety of portable digital X-ray Equipment for Emergency Medical Services in Daejon Emergency Medical Center in Korea. The major instruments of this study were Korean Self-Analysis Opinionnaire, Questionnaire contains 35 items which measure emergency medical personal opnions. To take the analysis of data, the total of 92 persons were investigated in Medical Information Center in Daejon Metropolitan City from 2005. 20. April to 2004. 25. May. The data were analyzed by the path analysis SPSS program. First, portable X-RAY equipment is needed to apply it to emergency. Second, it should have small and light structure compared with old equipments and have high voltage generator unit for X-RAY using inverter. Third, it should be able to send the shot data that is digital detector type without film to doctors in emergency center.

  • PDF

Improving Imaging Quality Assessment of Cabinet X-Ray Security Systems (캐비닛 엑스선 검색장비 이미지품질평가 고도화 방안 연구)

  • Yoon, Yeon Ah;Jung, Jin Hyeong;Kim, Yong Soo
    • Journal of Korean Society for Quality Management
    • /
    • v.49 no.1
    • /
    • pp.47-60
    • /
    • 2021
  • Purpose: This study proposes methods and procedures for evaluating imaging security systems quality of cabinet x-ray screening system to enhance performance certification technology. Also, conducted a comparative analysis of the literature of test-kit for imaging security quality evaluation. Methods: Comparative analysis of the test-kits and related documents for image quality assessment of cabinet x-ray screening equipment. This allows assessment items were selected and the methods for each assessment item were proposed. In addition, the configuration method of the assessment team was established by applying the technology readiness assessment(TRA). Results: Four of the assessment items were selected when estimate image quality by a comparative analysis of literature. For each assessment item, the evaluation method and minimum level of availability were determined. Finally, this paper proposes an imaging quality assessment of cabinet X-ray imaging security systems. Conclusion: Development of imaging security systems evaluation procedures for cabinet X-ray screening systems can be help improve performance certification of aviation security equipment.

A Plan to Improve Core Job Skills through the Level Management System : Focusing on the X-ray Screening Rating System (수준관리체계를 통한 핵심 직무역량 향상 방안 - 보안검색요원 판독등급제 중심으로 -)

  • Kim, Dong Min;Baek, Jeong Seon
    • Journal of Korean Society for Quality Management
    • /
    • v.51 no.4
    • /
    • pp.677-689
    • /
    • 2023
  • Purpose: The purpose of this study is to design a x-ray screening rating system to improve X-ray screening ability, which is a core job competency of security screener at Incheon International Airport, and to verify its effectiveness through empirical analysis to suggest ways to improve the level management system. Methods: In this study, the effectiveness of the research model was analyzed using T-test tests for effect analysis based on the empirical analysis results derived through the competency evaluation model, the screening rating system. Results: The results of this study are as follows. The average score for regular education before the implementation of the x-ray screening rating system was 94.1 points, but after the implementation of the x-ray screening rating system, the average score for regular education was 95.5 points, an average of 1.4 points increased. In addition, the proportion of those with 95 or more points classified as high scorers also increased significantly from 51.1% to 69.3%. Conclusion: The X-ray screening rating system of security inspectors will systematically manage the level of screening ability, which is a key job competency, and play a strong role in improving competency, while preventing security accidents through early identification and intensive training of level-lowers.

Pigment Analysis for Wall Paintings According to Verification of Penetration Depth for X-ray: Ssanggyesa Daeungjeon (Main Hall of Ssanggyesa Temple) in Nonsan (X-선 투과깊이 검증에 따른 벽화 안료의 정밀분석: 논산 쌍계사 대웅전)

  • Chun, Yu-Gun;Lee, Chan-Hee
    • Journal of Conservation Science
    • /
    • v.27 no.3
    • /
    • pp.269-276
    • /
    • 2011
  • We have suggested effective P-XRF analysis method for pigment painting layer by calculating penetration depth of X-ray. This experiment calculated that X-ray generated from P-XRF was possible penetration until 1.17mm deep in the pigment painting. Based on the experimental results, analysis for eight color pigments on wall paintings in Ssanggyesa Main Hall, most pigments were painted traditional pigments. However pigments on recently restorated wall painting were used synthetic modern pigments.

The Comparative Study between Leg Length Analysis and X-ray on Diagnosis of Pelvic Malpositions - according to Positions and Valuation Bases - (기능성 족지장단분석과 X-ray의 골반변위 진단의 비교 연구 - X-ray 촬영 자세 및 평가 기준에 따라 -)

  • Lee, Jung-Min;Koog, Gil-Ho;Choi, Bo-Mi;Jeong, Hyun-A;Hong, Seo-Young
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.5 no.2
    • /
    • pp.169-180
    • /
    • 2010
  • Objectives: This study was carried out to investigate the relationship of leg length analysis and X-ray finding according to positions and valuation bases on diagnosis of pelvic malpositions. Methods: Twenty-two people who get $33.09{\pm}10.73$ as average were evaluated by leg length analysis and X-ray findings. After measuring innominate measurement(IM), femur head line. distance between S2 and posterior superior iliac spine(PSIS). ilium shadow measurement(ISM), major axis of obturator foramen(MaF), minor axis of obturator foramen(MiF) and distance between off centering measurement and symphysis pubis, those were analyzed. Results: 1. In assessment of posterior rotation malposition ilium(PI), it was showed the best coincidence between leg length analysis and X-ray analyzed by 1M in supine position(11 cases, 50.5%). 2. In assessment of inflare, coincidence index between leg length analysis and X-ray were not good($4.00{\pm}3.03$ cases, $18.15{\pm}13.82%$). And leg length analysis were not sensitive. 3. On the whole, coincidence index between leg length analysis and X-ray were not good(best: 1 case, 45.5%; worst: 11 cases, 50.0%). Conclusions: Results form this investigation showed the relationship of leg length analysis and X-ray according 10 positions and valuation bases on diagnosis of pelvic malpositions. This results are expected to contribute to establish method of assessment in diagnosis of pelvic malpositions.

  • PDF

The Effect of Applying the X-ray Screening Ability Rating for Security Screening Persons in Incheon International Airport (인천국제공항 보안검색요원 X-ray 판독등급제 적용 효과)

  • Yung-Kil Lee;Jeong-Sun Baek;Dong-Min Kim
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.6
    • /
    • pp.733-739
    • /
    • 2023
  • The purpose of this study verify to the effect of applying the X-ray screening ability rating for security screening persons in Incheon International Airport. Data collected through a evaluation score of 1,034 security screening persons in Incheon International Airport. Data analysis performed using paired sample t-test. The research results found that it was a statistically significant difference pre-test and post-test applying the X-ray screening ability rating. In this article, we asserts that the X-ray screening ability rating is effective in improving the X-ray screening ability of security screening persons. This paper contribute to the academic expansion of motivation theory and self-determination theory. This study is valuable as a preemptive empirical research that provides practical implications about the application of X-ray screening ability rating for security screening persons.