• Title/Summary/Keyword: X-ray Imaging System

Search Result 290, Processing Time 0.024 seconds

Study of Image Properties for Computed Radiography (Computed Radiography의 영상특성에 관한 연구)

  • Ryu, Ki-Hyun;Jung, Jae-Eun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.2
    • /
    • pp.23-31
    • /
    • 2008
  • Computed radiography(CR) has been widely used in the field of diagnostic radiography since digital X-ray image was introduced. The imaging performance of CR system was studied by analyzing the digital image data of the CR images which are the outcomes of the whole imaging system composed of image plate(IP), laser digitizer, analoge-digital convertor, and a given image processing unit. In this study, we used a conventional CR system made by Agfa. From the flat field image of 150$\times$150 image pixels, signal-to-noise ratio(SNR) was calculated. SNR of the CR image increases in proportion to logarithm value of the X-ray exposure irradiated on the IP. SNR is less than about 6 at the exposure below 0.2mR and is more than 10 at the exposure above 0.54mR. In our study, most of images obtained by the smaller exposures less than 2.0mR can not be readable. In general, the minimum value of the SNR ranges from 3 to 5. We obtained modulation transfer function(MTF) by analyzing the bar pattern image which was made under conditions as follows: X-ray tube potential was 55kVp, the IP exposure was 0.54 mR, and the distance between X-ray source to IP was 2m, where bar pattern was located on the IP. MTF is 23% at 2.5lp/mm spatial frequency. Provided that the MTF of noise equivalent modulation is 10%, the CR system has the limiting spatial resolution of 3.2lp/mm. If the image sharpness is evaluated by the spatial frequency where MTF is 50%. the corresponding spatial frequency is 0.5$\sim$0.75lp/mm. MTFA(Modulation Transfer Function Area) is 1.0lp/mm. Compared with the Fuji CR whose MTFA is 1.1lp/mm, Agfa CR in this study shows almost same MTFA performance.

  • PDF

Development of Data Acquisition System using the Backscattered X-ray (후방산란성 엑스레이를 이용한 데이터 획득 시스템 개발)

  • Hwang, In-Ho;Jung, Jin-Seok;Yuk, Sun-Woo;Yoo, Sun-Kook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.10
    • /
    • pp.129-133
    • /
    • 2009
  • Considerable attention has been focused on digital X-ray systems with transmission. However, only a few attempts have been made using X-ray backscatter systems. This study developed a Data Acquisition System (DAS) for backscattered X-rays. The imaging system used X-ray backscatter at low energy levels, which has unique advantages in terms of acquiring information that cannot be obtained using the transmission system. Such systems are of potential benefit in the medical, industrial, security and military fields because of its practical benefits and the low doses used. The developed system is a similar body scan system. Experiments were carried out using a several metal materials and a fish, which produces results similar to those obtained using the human body during X-ray testing.

Development and Evaluation of Parallel Beam Optic for X-ray (엑스선용 평행빔 광학소자 개발 및 평가)

  • Park, Byunghun;Cho, Hyungwook;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.477-481
    • /
    • 2012
  • An X-ray diffractometer which has various X-ray optics can give qualitative and quantitative information for a sample using a nondestructive analysis method. A parallel beam optic passes the parallel beam and removes divergent beam generated from an X-ray tube. The parallel beam optic used in the X-ray diffractometer was fabricated by wire cut and grading of stainless steel plates and was evaluated its performance using an X-ray imaging system. The measured parallelization of 6.6 mrad for the fabricated the parallel beam optic was a very close to the expected value of 6 mrad. An X-ray imaging technique for evaluating the parallel beam optics can estimate parallelization for each plate and can be used to other X-ray optics.

Development of a Small Animal CT using a Linear Detector Array and Small-Scale Slip Rings

  • An Ung Hwan;Chun In Kon;Lee Sang Chul;Cho Min Hyoung;Lee Soo Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.1
    • /
    • pp.43-47
    • /
    • 2005
  • We have developed a small bore x-ray CT for small animal imaging with a linear x-ray detector array and small-scale slip rings. The linear x-ray detector array consists of 1024 elements of 400□m×400□m with a gadolinium oxysulfide (GOS) scintillator on top of them. To avoid use of expensive large diameter slip rings for projection data transmission from the X­ray detector to the image reconstruction system, we used the wireless LAN technology. The projection data are temporally stored in the data acquisition system residing on the rotating gantry during the scan and they are transmitted to the image reconstruction system after the scan. With the wireless LAN technology, we only needed to use small-scale slip rings to deliver the AC electric power to the X-ray generator and the power supply on the rotating gantry. The performances of the small animal CT system, such as SNR, contrast, and spatial resolution, have been evaluated through experiments using various phantoms. It has been experimentally found that the SNR is almost linearly proportional to the tube current and tube voltage, and the minimum resolvable contrast is less than 30 CT numbers at 40kVp/3.0㎃. The spatial resolution of the small animal CT system has been found to be about 0.9Ip/㎜. Postmortem images of a piglet is also presented.

Effects of the Geometrical Misalignment on the MTF Measurement (변조전달함수 측정에 있어 기하학적 조정 불량이 해상도에 미치는 영향)

  • Kim, Jun-Woo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.5
    • /
    • pp.705-713
    • /
    • 2021
  • The modulation transfer function (MTF) is calculated to analyze the resolution of the spatial frequency of the image acquired from the x-ray imaging system. In general, the response function of the detector acquires a line spread function (LSF) using a slit-camera, and derives a modulation transfer function through a Fourier transform. Because of the fact that the x-ray must always be incident on the center of the slit-camera, the tilt of the detector and slit-camera caused by the experimenter will affect the detector performance. In addition, if the tilt increases, the performance evaluation of the x-ray image system will be problematic. In this study, we analyzed the experimental and analytical models in the modulation transfer function, ie, the Fourier domain, based on the experimental error and analyzed the effect on the spatial frequency. Furthermore, performance evaluation is being carried out for various x-ray imaging systems, and experimental errors are indispensable, and the extent to which they can be tolerated should be reviewed.

The Characteristic of Temperature and Dose Distribution of intra oral X-ray Tube (강내형 X선 튜브 온도 및 선량 분포 특성)

  • Cho, Sungho;Lee, Rena
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.5
    • /
    • pp.262-266
    • /
    • 2013
  • A new concept of periapical radiography, intra oral x-ray tube and detector system is introduced. It is new system that a miniature x-ray tube is inserted into mouse and it acquired digital image using external detector. In this study, we have investigated temperature and dose distribution of insertional x-ray tube for periapical radiography. To analyze temperature characteristic of x-ray tube, we attached the thermocouple to surface of x-ray tube and we measured the temperature according to distance. Also, we measured the dose distribution of a miniature x-ray tube according to distance. As a result, temperature was constant to $27^{\circ}C$ over 2mm without cooling system, dose distribution of x-ray tube was 3.14 and 1.84mGy in 3 and 5cm, respectively. Therefore, the proposed x-ray system works in lower dose than conventional dental x-ray system. Thus, it is considered that new concept of system will have a significant effect on medical imaging technology.

Three Dimensional Volume Reconstruction of an Object from X-ray Iamges using Uniform and Simultaneous ART (USART 방법에 의한 X선 영상으로부터의 삼차원 물체의 형상 복원)

  • Roh, Young-Jun;Cho, Hyung-Suck;Kim, Hyeong-Cheol;Kim, Jong-Hyung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.1
    • /
    • pp.21-27
    • /
    • 2002
  • Inspection and shape measurement of three-dimensional objects are widely needed in industries for quality monitoring and control. A number of visual or optical technologies have been successfully applied to measure three-dimensional surfaces. However, those conventional visual or optical methods have inherent shortcomings such as occlusion and variant surface reflection. X-ray vision system can be a good solution to these conventional problems, since we can extract the volume information including both the surface geometry and the inner structure of any objects. In the x-ray system, the surface condition of an object, whether it is lambertian or specular, does not affect the inherent characteristics of its x-ray images. In this paper, we propose a three-dimensional x-ray imaging method to reconstruct a three dimensional structure of an object out of two dimensional x-ray image sets. To achieve this by the proposed method, two or more x-ray images projected from different views are needed. Once these images are acquired, the simultaneous algebraic reconstruction technique(SART) is usually utilized. Since the existing SART algorithms have several shortcomings such as low performance in convergence and different convergence within the reconstruction volume of interest, an advanced SART algorithm named as USART(uniform SART) is proposed to avoid such shortcomings and improve the reconstruction performance. Because, each voxel within the volume is equally weighted to update instantaneous value of its internal density, it can achieve uniform convergence property of the reconstructed volume. The algorithm is simulated on various shapes of objects such as a pyramid, a hemisphere and a BGA model. Based on simulation results the performance of the proposed method is compared with that of the conventional SART method.

Conceptual Design of Laser Plasma-based Soft X-ray Microscope system for Biomedical Application (레이저 플라즈마 기반의 생물의료용 연 X-선 현미경 설계)

  • 김경우;윤권하
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.690-693
    • /
    • 2003
  • Soft x-ray microscopy provides a unique set of capabilities in-between those of visible light and electron microscopy. It has long been recognized that nature provides a 'water window' spectral region between the K shell x-ray absorption edges of carbon (~290eV) and oxygen (~540eV), where organic materials show strong absorption and phase contrast, while water is relatively non-absorbing. This enables imaging of hydrated biological specimens that are several microns thick with high intrinsic contrast using x-rays with a wavelength of 2.3~4.4nm. Soft X-ray microscopy is therefore well suited to the study of specimens like single biological cells. The most direct advantage of X-ray microscope is their high spatial resolution when compared with visible light microscopes, combined with an ability to image hydrated specimens that are several microns with a minimum of preparation. Our study describes the conceptual design of soft x-ray microscope system based on a laser-based source for biomedical application with high resolution ($\leq$50nm) and short exposure time ($\leq$30sec).

  • PDF

Current Topics on Quality Assurance of X-ray Diagnosis in Japan

  • Katoh, Tuguhisa;Imamura, Keiko;Matumoto, Toru
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.13-16
    • /
    • 2002
  • Recent topics on quality assurance (QA) of X-ray diagnosis in Japan were reported in this presentation. These were related to mass screening mammography (MMG), lung screening CT (LSCT), skin injury caused by interventional radiology (IVR) and traceable system of dosimeters for x-ray diagnosis. In these successful stories, the author would like to stress the cooperation of all the medical am: clinical staff including medical doctors, radiological technologists, medical physicists, manufacturers of medical devices and others.

  • PDF