• 제목/요약/키워드: X-ray Film

검색결과 2,292건 처리시간 0.028초

X선촬영시(X線撮影時) 피사체(被寫體) 두께에 따른 격자비(格子比) 선정(選定)에 관한 연구(硏究) (Studios in Selected Grid Ratio of Objective Thickness on X-ray Exposure)

  • 윤철호;추성실;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제5권1호
    • /
    • pp.21-34
    • /
    • 1982
  • When unattenuated x-ray radiation passes through the object it is transmitted and scattered from objectes and impinging on the film. During this process certain radiation is absorbed within the object and others transmitted in reduced scattering. The scattering radiation influence upon radiation image quality, confining x-ray beam which means scattering radiation produce increased fog on x-ray film image and as a consequence decrease contrast and less detail of the film there for the elimination of fog and for absorbing scattered radiation, the grid has been used between the object and the film in order to rid of scattering rays. Using grid is good method for the qualification of the better image as well as in using air gap technique. The grid is easy to manipulate and promote good efficiency which is defined by ICRU and JIS. It is the purpose to study for eliminating scattered radiation from the tissue equivalent acryl phantom using grid, we have studied and evaluated the grid permeability about the x-ray exposure, the selection of grid ratio according to phantom thickness, on x-ray exposure are performed as follows. 1. The penetrating ratio of primary x-ray is remarkably decreased by increasing of the grid ratio, but it is almost not influenced in KVP difference and phantom thickness. 2. The scattered radiation is proportionaly increased by thickness of the phantom, having nothing to do with grid ratios. 3. The relative between the penetration rate of primary and secondary x-ray is improved by increasing grid ratio, and decreased by phantom thickness, and slightly decreased by high tube voltage. 4. The grid of 5:1 and 10:1 ratio are adequate to the phantom of 10cm and 15cm thickness, respectively.

  • PDF

픽셀내 다수의 산화물 박막트랜지스터로 구성된 동영상 엑스레이 영상센서와 디텍터에 대한 평가 (Evaluation of Dynamic X-ray Imaging Sensor and Detector Composing of Multiple In-Ga-Zn-O Thin Film Transistors in a Pixel)

  • 전승익;이봉구
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.359-365
    • /
    • 2023
  • 높은 초당 프레임 속도와 낮은 영상지연을 갖는 동영상 엑스레이 디텍터의 요구조건을 만족하기 위해서는 픽셀내 포토다이오드와 금속 배선간 중첩 영역의 기생정전용량을 최소화하여야 한다. 본 연구에서는 리드아웃 박막트랜지스터, 리셋 박막트랜지스터, 그리고 포토다이오드로 픽셀이 구성된 듀오픽스TM(duoPIXTM) 동영상 엑스레이 영상센서를 처음으로 제시하였다. 이후 150 × 150 mm2 영상영역, 73 ㎛ 픽셀 크기, 2048 × 2048 해상도(4.2 M pixels), 최대 초당 50 프레임의 특성을 갖는 duoPIXTM 동영상 엑스레이 디텍터를 제작하여 초당 프레임 속도, 감도, 노이즈, MTF, 영상지연과 같은 엑스레이 영상 성능을 기존 엑스레이 영상센서를 적용한 동영상 엑스레이 디텍터와 비교 평가하였다. 평가 결과 이전 연구에서 기대했던 것과 같이 duoPIXTM 동영상 엑스레이 디텍터가 기존 동영상 엑스레이 디텍터 대비 모든 특성에서 우위의 성능을 보여 주었다.

Kodak Insight 치과필름의 특성에 관한 연구 (Study on the characteristics of Insight dental x-ray film)

  • 송영한;이완;이병도
    • Imaging Science in Dentistry
    • /
    • 제33권1호
    • /
    • pp.21-26
    • /
    • 2003
  • Purpose: To investigate the characteristics of the newly marketed, Insight dental X-ray film. Materials and Methods: Kodak Ultraspeed (DF-58), E-speed, Agfa Dentus M2, and Kodak Insight (IP-21) films were radiographed using a Trophy intra-oral radiographic machine. 10 step exposure times were prepared and each step exposure was monitored using a FH 40G (ESM Eberline Instruments) dosimeter for each of the 4 types of intra-oral film. All films were manually processed and the radiographic densities at 6 sites of each processed film were measured, and the characteristic curves of each of the 4 types intra-oral films were created utilizing these dosimetric data and radiographic densities, based on ISO 5779. The film contrast, speed, and base plus fog density of Insight film were compared with those of the 3 other films examined in this experiment. Results : E-speed film showed greatest average gradients followed by Insight film. E-speed and Ultraspeed film showed great average gradients at low density levels. Insight film showed the fastest speed followed by E-speed, Dentus M2 and Ultraspeed film. Dentus M2 film showed greatest base plus fog density level followed by Insight film. Conclusion : Kodak Insight film showed fastest film speed with comparable film contrast on characteristic curve.

  • PDF

Effect of thickness on properties of ZnO film prepared by direct current reactive magnetron sputtering method

  • Baek, C.S.;Kim, D.H.;Kim, H.H.;Lim, K.J.
    • Journal of Ceramic Processing Research
    • /
    • 제13권spc2호
    • /
    • pp.403-406
    • /
    • 2012
  • Effect of thickness on ZnO properties including the compositional ratio and crystallinity has been systematically investigated using a variety of characterization tools of x-ray diffraction, field emission scanning electron microscopy, x-ray fluorescence and x-ray photoelectron spectroscopy. Interestingly, it was observed that ZnO films below 80 nm in thickness were in oxygen deficiency, while the oxygen ratio was increased in the films above the thickness, although the compositional ratio of ZnO film was not linearly varied with increasing film thickness. Also, ZnO crystallinity, which is characterized by (002) diffraction pattern, was clearly improved with increasing film thickness. The properties of ZnO film with different sputtering time and the nature of direct current reactive sputtering process were discussed in terms of compositional ratio, especially oxygen ratio in ZnO film.

X-Ray Reflectivity Analysis Incorporated with Genetic Algorithm to Analyze the Y- to X Type Transition in CdA LB Film

  • 최정우;조경상;이희우;이원홍;이한섭
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권5호
    • /
    • pp.549-553
    • /
    • 1998
  • The structure and layer distribution of cadmium arachidate Langmuir-Blodgett film were analyzed by the small angle X-ray reflectivity measurements using synchrotron radiation. Y-to X type transition was ocurred during the 39th passage of deposition of cadmium arachidate. Based on the measurement of the consumed area of the monolayer, it was determined that about 27.5 layer was deposited. Using the synchrotron X-ray, the reflectivity profile of cadmium arachidate LB film over the wide range of grazing angle was obtained. The X-ray reflectivity profile was analyzed using the recursion formula. By fitting the location and dispersion of the subsidiary maxima between the Bragg peaks of the measured reflectivity profile with that of the calculated reflectivity profile, the average thickness and the distribution of layer thickness were evaluated. The genetic algorithm was adopted to the fitting of reflectivity profile to evaluate the optimum value of the number distribution of layer. Based on the morphology measurement with an atomic force microscopy (AFM), the domain structure and mean roughness of LB films were obtained. The mean roughness value calculated based on the number of layer distribution obtained from the measurement by AFM is consistent with that obtained from X-ray reflectivity analysis.

고효율 X선 검출기 적용을 위한 PbO 필름 제작 및 특성 연구 (Fabrication and Characterization of Lead Oxide (PbO) Film for High Efficiency X-ray Detector)

  • 조성호;강상식;최치원;권철;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.329-329
    • /
    • 2007
  • Photoconductive poly crystalline lead oxide coated on amorphous thin film transistor (TFT) arrays is the best candidate for direct digital x-ray detector for medical imaging. Thicker films with lessening density often show lower x-ray induced charge generation and collection becomes less efficient. In this work, we present a new methodology used for the high density deposition of PbO. We investigate the structural properties of the films using X-ray diffraction and electron microscopy experiments. The film coatings of approximately $200\;{\mu}m$ thickness were deposited on $2"{\times}2"$ conductive-coated glass substrates for measurements of dark current and x-ray sensitivity. The lead oxide (PbO) films of $200\;{\mu}m$ thickness were deposited on glass substrates using a wet coating process in room temperature. The influence of post-deposition annealing on the characteristics of the lead oxide films was investigated in detail. X-ray diffraction and scanning electron microscopy, and atomic force microscopy have been employed to obtain information on the morphology and crystallization of the films. Also we measured dark current, x-ray sensitivity and linearity for investigation of the electrical characteristics of films. It was found that the annealing conditions strongly affect the electrical properties of the films. The x-ray induced output charges of films annealed in oxygen gas increases dramatically with increasing annealing temperatures up to $500^{\circ}C$ but then drops for higher temperature anneals. Consequently, the more we increase the annealing temperatures, the better density and film quality of the lead oxide. Analysis of this data suggests that incorporation and decomposition reactions of oxygen can be controlled to change the detection properties of the lead oxide film significantly. Post-deposition thermal annealing is also used for densely film. The PbO films that are grown by new methodology exhibit good morphology of high density structure and provide less than $10\;pA/mm^2$ dark currents as they show saturation in gain (at approximate fields of $4\;V/{\mu}m$). The ability to operate at low voltage gives adequate dark currents for most applications and allows voltage electronics designs.

  • PDF

디지털 X-선 변환물질을 위한 비소(As) 첨가 비정질 셀레늄(a-Se) 박막의 수송현상 (Transport phenomena of a-Se:As thin film for digital X-ray Conversion Material)

  • 박창희;김재형
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.282-283
    • /
    • 2006
  • The transport phenomena of arsenic (As) doped amorphous selenium(a-Se:As) thin film for digital X-ray conversion material has been reported. The effect of As addition on the carrier mobility and recombination lifetime in a-Se:As sample has been measured using the moving photo-carrier grating (MPG) technique. An Increase in hole mobility and recombination was observed when 0.3% arsenic, was added into a-Se sample, whereas electron mobility decrease with arsenic addition due to the defect density. The fabricated a-Se:03% As device exhibited the highest X-ray sensitivity.

  • PDF

Thickness-dependent magnetic domain structures of Co ultra-thin film investigated by scanning transmission X-ray microscopy

  • Yoon, Ji-Soo;Kim, Namdong;Moon, Kyoung-Woong;Lee, Joo In;Kim, Jae-Sung;Shin, Hyun-Joon;Kim, Wondong
    • Current Applied Physics
    • /
    • 제18권11호
    • /
    • pp.1185-1189
    • /
    • 2018
  • Thickness-dependent magnetic domain structure of ultrathin Co wedge films (0.3 nm-1.0 nm) sandwiched by Pt layers was investigated by scanning transmission x-ray microscopy (STXM) employing X-ray magnetic circular dichroism (XMCD), utilizing elliptically polarized soft x-rays and electromagnetic fields, with a spatial resolution of 50 nm. The magnetic domain images measured at the Co $L_3$ edge showed the evolution of the magnetic domain structures from maze-like form to the bubble-like form as the perpendicular magnetic field was applied. The asymmetric domain expansion of a 500 nm-scale bubble domain was also measured when the in-plane and perpendicular external magnetic field were applied simultaneously.

인체 두부에서 Dynamic Tomogram의 응용에 관한 연구 (A STUDY ON THE APPLICATION OF DYNAMIC TOMOGRAM OF THE HUMAN HEAD)

  • 최의환;김재덕
    • 치과방사선
    • /
    • 제21권2호
    • /
    • pp.317-326
    • /
    • 1991
  • The purpose of this study was to establish the principle and the clinical application of dynamic tomogram of a human head by using the dental machine. For this study, a block of wax with details lying at three parallel planes and a human dry skull were used. This experiment was reexamined the dynamic tomogram with specialized radiographic device and view box, and the radiograms taken by the change of exposure time according to the numbers of film used in x-ray taking and taken according to the change of kVp and the types of film were analyzed density with the densitometer. From this study, the obtained results were as follows: 1. When the underexposed radiograms taken by angulation of clockwise and counter-clockwise direction of the film and skull. were superimposed and moved laterally, it was possible to focus on right and left jaws and teeth. 2. The superimposition of the two underexposed radiograms according to each condition of x-ray taking showed some differencies in density visually, and the measurement of density with the densitometer was 1.23 to 1.57 in 75kVp and 1.34 to 1.70 in 90kVp. 3. The superimposition of the two underexposed radiograms according to the kinds of x-ray film showed almost equal density visually, and the measurement of density with the densiometer was 1.34 to 1.37. 4. When seven radiograms taken by each condition of x-ray taking were superimposed on the view box, a intense rear light of view box didn't transilluminate film density regardless of the conditions of x-ray taking. Even though seven radiograms taken according to types of film were superimposed on the view box, a more intense rear light of view box was required to transilluminate total density of films. 6. Long film-object distance resulted in the enlargement and blurring of radiographic images.

  • PDF

X-선촬영 조사 조건하에서 다결정 요오드화수은 박막검출기의 신호특성 분석 (Analysis of the Signal Properties of Polycrystalline $HgI_2$ Film Detector under Radiographic Irradiation Condition)

  • 김종언
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권3호
    • /
    • pp.289-294
    • /
    • 2010
  • 이 연구의 목적은 다결정 요오드화수은 박막검출기를 제작하여 X-선촬영 조사 조건하에서 검출기 성능의 평가이다. 두께 210과 $320 \;{\mu}m$를 갖는 다결정 요오드화수은 박막검출기들은 스크린 프린트 기술로 제작하였다. X-선 감도와 암전류의 측정들은 두 검출기에 대하여 수행하였다. 그리고 X-선 반응의 선형성과 재현성의 측정들은 두께 $320 \;{\mu}m$의 검출기에 대하여 수행하였다. 두께 $320 \;{\mu}m$의 검출기에 인가된 0.05에서 $2\;V/{\mu}m$까지의 전기장 강도들에 대하여, X-선 감도들은 233에서 $1,408{\times}10^6\;electrons/mR{\cdot}mm^2$까지 측정되었다. 그리고 암전류들은 3.2에서 $118\;pA/mm^2$까지 측정되었다. Zhong Su 등에 의해 보고된 값들과 비교에서, X-선 감도들은 Zhong Su 등에 의해 측정된 X-선 감도들보다 약 2배 더 크게 나타냈다. 그리고 암전류들은 Zhong Su 등에 의해 측정된 암전류들보다 약 9배 더 크게 나타냈다. X-선 반응의 선형성은 상관계수(r)로서 0.988을 얻었다. 재현성은 변동계수로서 0.002를 얻었다. 이 연구는 X-선촬영 조사 조건하에서 능동매트릭스 평판영상장치에 사용할 수 있는, 제작된 다결정 요오드화수은 박막검출기의 성능 데이터를 제공한다.