• Title/Summary/Keyword: X-ray Field

Search Result 1,746, Processing Time 0.032 seconds

A Study on the Measurement of Plastic Zone Depth using TRIZ (창의적 문제해결 이론을 이용한 소성역깊이 측정에 관한 연구)

  • Lee, Dong-Woo;Joo, Won-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.1
    • /
    • pp.62-66
    • /
    • 2008
  • Machine parts subjected to fluctuating or cyclic loads induce repeated stresses that often result in failure by fatigue. In such cases, the fatigue failures unfortunately sometimes occur. These may arise from a lack of knowledge with regard to the design, fabrication and operation of the machines or structures. The failure analysis provides valuable information regarding the prevention of similar failures. Furthermore, this information will be useful to improve or to develop new products. Failure stress analysis is classified into X-ray fractography. X-ray fractography has the limited applications because of material crystal size, difficult measurement method, electrolytic polishing precision, and long test time. Therefore, this study proposed the new method to improve the measurement precision of plastic zone depth and test time using TRIZ.

  • PDF

The Off-Axis Properties of Solar X-Ray Telescopes: I. Evaluation of the Vignetting Effect

  • Shin, Jun-Ho;Sakurai, Takashi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.35.1-35.1
    • /
    • 2011
  • The solar X-ray telescopes, the Yohkoh SXT and the Hinode XRT, have observed for a couple of decades a variety of coronal structures in the range of wide field-of-view (FOV) covering the full solar disk. It has been emphasized that the optical structure of solar telescopes should be designed with care for improving the uniformity over the full FOV. The vignetting effect is one of the important optical characteristics for describing the performance of a telescope, which reflects the ability of collecting the incoming light at different locations and different photon energies. The correction of this vignetting effect would be an important calibration step that should be performed in advance, especially when the observed images are to be used for photometric purposes. Since the vignetting effect of solar X-ray telescopes shows wavelength dependence, a special care should be taken when, for example, performing the temperature analyses with thin and thick filters for flaring activities observed at the periphery of the full FOV. The results of analysis of pre-launch calibration data for the evaluation of vignetting effect will be introduced in detail.

  • PDF

X-ray Diffraction Analysis of Residual Stress in Laminated Ceramic

  • Jin, Young-Ho;Chung, Dong-Yoon
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.5
    • /
    • pp.458-462
    • /
    • 2011
  • The strength of ceramic was improved by lamination by suppressing the propagation of cracks with compressive residual stress in the face layer of the laminate. Hot pressed SiAlON+SiC/SiC/SiAlON+SiC laminate discs were fabricated for tailored residual stress. The residual stress in this laminate was studied by X-ray diffraction (XRD). There was considerable compressive residual stress in the face layer. A Finite Element Analysis (FEA) was performed to support the measured XRD results and to determine the stress field in the laminate. The residual stress measured by XRD had satisfactory agreement with the analytically calculated and FEA values. The measured value by XRD was -385 ${\pm}$ 20 MPa over most of the face layer. The calculated and FEA values were -386 MPa and -371MPa, respectively. FEA also showed significantly modified stresses and the maximum tensile stress near the edge region which are possible crack generators in the presence of flaws or contact damage.

The Synthesis of Maghemite and Hematite Nanospheres

  • Dar, Mushtaq Ahmad;Ansari, Shafeeque G.;Wahab, Rizwan;Kim, Young-Soon;Shin, Hyung-Shik
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.472-473
    • /
    • 2006
  • Maghemite and hematite nanospheres were synthesized by using the Sol-gel technique. The structural properties of these nanosphere powders were characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM), field emission scanning electron microscopy (FESEM), and pore size distribution. Hematite phase shows crystalline structures. The mean particle size that resulted from BET and XRD analyses were 4.9 nm and 2 nm. It can be seen from transmission electron microscopy that the size of the particles are very small which is in good agreement with the FESEM and the X-ray diffraction. The BET and pore size method were employed for specific surface area determination.

  • PDF

Spin-polarization and x-ray magnetic circular dichroism in GaAs

  • Zohar, S.;Ryan, P.J.;Kim, J.W.;Keavney, D.J.
    • Current Applied Physics
    • /
    • v.18 no.11
    • /
    • pp.1182-1184
    • /
    • 2018
  • The combination of angular spin momentum with electronics is a promising successor to charge-based electronics. The conduction bands in GaAs may become spin-polarized via optical spin pumping, doping with magnetic ions, or induction of a moment with an external magnetic field. We investigated the spin populations in GaAs with x-ray magnetic circular dichroism for each of these three cases. We find strong anti-symmetric lineshapes at the Ga $L_3$ edge indicating conduction band spin splitting, with differences in line width and amplitude depending on the source of spin polarization.

Effect of thickness on properties of ZnO film prepared by direct current reactive magnetron sputtering method

  • Baek, C.S.;Kim, D.H.;Kim, H.H.;Lim, K.J.
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc2
    • /
    • pp.403-406
    • /
    • 2012
  • Effect of thickness on ZnO properties including the compositional ratio and crystallinity has been systematically investigated using a variety of characterization tools of x-ray diffraction, field emission scanning electron microscopy, x-ray fluorescence and x-ray photoelectron spectroscopy. Interestingly, it was observed that ZnO films below 80 nm in thickness were in oxygen deficiency, while the oxygen ratio was increased in the films above the thickness, although the compositional ratio of ZnO film was not linearly varied with increasing film thickness. Also, ZnO crystallinity, which is characterized by (002) diffraction pattern, was clearly improved with increasing film thickness. The properties of ZnO film with different sputtering time and the nature of direct current reactive sputtering process were discussed in terms of compositional ratio, especially oxygen ratio in ZnO film.

Implementation of a Full Field Digital Mammography (디지털 유방X-선촬영기의 구현)

  • Roh, Young-Sup;Yeo, Se-Yeon;Lee, Jae-Jun;Sohn, Surg-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4578-4589
    • /
    • 2011
  • The technologies of image acquisition, display, and storage of the breast have been developed in their specialized fields in recent years. The image acquisition system is a device that absorbs and stores images after examining breast tissue using X-ray. Due to the specificity and sensitivity of imaging, the early detection of breast cancer is feasible. In this paper, the current technologies for digital mammography are reviewed, and we propose a digital mammography and evaluate the performance of the implemented system.

Microcalcification Extraction by Wavelet Transform and Automatic Thresholding (웨이브렛 변환과 자동적인 임계치 설정에 의한 미세 석회화 검출)

  • Won, Chul-Ho;Seo, Yong-Su;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.8 no.4
    • /
    • pp.482-491
    • /
    • 2005
  • In this paper, we proposed the microcalcification detection algorithm which is based on wavelet transform and automatic thresholding method in the X-ray mammographic images. Digital X-ray imaging system is essential equipment in the field diagnosis and is widely used in the various fields such as chest, fracture of a bone, and dental correction. Especially, digital X-ray mammographic imaging is known as the most important method to diagnose the breast cancer, many researches to develop the imaging system are processing in country. In this paper, we proposed a microcalcifications detection algorithm necessary in the early phase of breast cancer diagnosis and showed that a algorithm could effectively detect microcalfication and could aid diagnosis-radiologist.

  • PDF

Digital X-ray Detector에 적용을 위한 Polycrystalline CdTe 구조에 따른 전기적 신호 연구

  • Kim, Jin-Seon;O, Gyeong-Min;Jo, Gyu-Seok;Song, Yong-Geun;Hong, Ju-Yeon;Heo, Seung-Uk;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.484-484
    • /
    • 2013
  • 기존 진단용 Digital X-ray Detector이 직접방식에서는 a-Se (Amorphous Selenium)이 대중화되었지만 고전압을 인가하여야한다는 점과 그로 인한 물질 자체의 Life time 감소 등 여러 단점들 때문에 기타 후보물질들로 HgI2, PbI2, PbO, CdTe, CdZnTe가 연구 되고 있다. 이러한 후보 물질들 중 본 연구에서는 PVD (Physical Vapor Deposition)방식을 이용하여 Polycrystalline CdTe 박막을 제작하고 특성 향상을 위해 유전물질을 Passive layer와 Protect layer로써 증착하였다. 또한 유전체층의 위치에 따른 특성 분석을 위해 제작된 박막은 FE-SEM (Field Emission Scanning Electron Microscope), XRD (X-ray Diffraction)을 통해 구조적인 특성을 확인하였다. 그리고 입사되는 X-ray 선량에 의해 생성되는 전기적 특성을 분석하였다, 그 결과 박막의 Grain Size는 약 $5{\mu}M$이며 (111)방향의 주 peak를 띄는 Poly CdTe형태로 증착된 것을 확인하였다. 전기적인 신호 결과 Passive layer와 Protect layer를 증착한 박막 모두 Darkcurrent가 감소된 것을 확인하였다. 또한 Sensitivity 측정 결과 Passive layer를 삽입한 경우 신호 값이 감소하였으며 Protect layer를 삽입한 경우 신호 값의 변화가 일어나지 않았다. 그러므로 Protect layer를 등착한 박막의 경우 SNR이 현저히 높아지는 결과를 낳았다.

  • PDF

Zoom-in X-ray Micro Tomography System

  • Chun, In-Kon;Lee, Sang-Chul;Park, Jeong-Jin;Cho, Min-Hyoung;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.5
    • /
    • pp.295-300
    • /
    • 2005
  • We introduce an x-ray micro tomography system capable of high resolution imaging of a local region inside a small animal. By combining two kinds of projection data, one from a full field-of-view (FOV) scan of the whole body and the other from a limited FOV scan of the region of interest, we have obtained zoomed-in images of the region of interest without any contrast a nomalies. We have integrated a micro tomography system using a micro-focus x-ray source, a $1248\times1248$ flat-panel x-ray detector, and a precision scan mechanism. Using the cross-sectional images taken with the zoom-in micro tomography system, we measured trabecular thicknesses of femur bones in postmortem rats. To compensate the limited spatial resolution in the zoom-in micro tomography images, we used the fuzzy distance transform for the calculation of the trabecular thickness. To validate the trabecular thickness measurement with the zoom-in micro tomography images, we compared the measurement results with the ones obtained from the conventional micro tomography images of the extracted bone samples.