Image Quality and Dose Assessment According to Examination Mode during Head CT Examination (두부 CT 검사 시 검사 모드에 따른 화질 및 선량평가)

  • Gang, Heon-Hyo;Choi, Woo-Jeon;Kim, Dong-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.437-444
    • /
    • 2021
  • To evaluate the usefulness of Volume Axial Mode by comparing analyzing the exposure dose of the patients and the quality of each images from CT images obtained from high pitch mode using the local phantom or volume axial mode to determine the usefulness of he volume axial mode in diagnosing the head and cervical disease in adults. High Pitch Mode, Helical Mode, and Volume axial Mode as adult phantom were tested according to 70 kVp, 80 kVp, and 100 kVp tube voltages during an adult frontal CT scans. The equipment used was GE's Revolution (GE Healthcare, Wisconsin USA) model and iMED X-ray Phantom. The exposure dose of phantom was compared using the images obtained from each protocol, and the image quality was compared by calculating SNR and CNR by setting ROI on each image. When examined using Volume Axial Mode, the exposure dose of phantom was measured 17.12% lower than Helical Mode, 5.35% lower than High Pitch Mode, and both SNR and CNR were improved. Volume Axial Mode is a useful test that reduces investigation time without table movement using high speed rotary scanner, and in which exposure dose is reduced and image quality is improved by acquiring images in a short time of 0.28 seconds of phantom than using High Pitch Mode and Helical Mode. In addition, the fast testing time of Volume Axial Mode can be seen as the biggest advantage CT scans of emergency patients or patients with physical discomfort.

Survery on Business of the Departments of Radiology in Health Centers (보건소(保健所)의 방사선과(放射線科) 업무(業務)에 관한 조사연구(調査硏究))

  • Choi, Jong-Hak;Jeon, Man-Jin;Huh, Joon;Park, Sung-Ock
    • Journal of radiological science and technology
    • /
    • v.8 no.2
    • /
    • pp.21-28
    • /
    • 1985
  • We serveyed the actual condition of business of the departments of radiology of 45 health conters (except 3) in the area of Seoul, Kyungki and Inchon from March, 1984 to November, 1984. The results are summarized as follows : 1. T.O. of the radiologic technologist is three persons in each health center of Seoul area, and one person in each one of Kyungki and Inchon area. P.O. is 2-5 persons in Seoul area, 1-2 persons in Kyungki or Inchon area. 2. The number of all the radiologic technologists employed now is 75 persons, and among all of them, when analized by position class 7th is 54.7%, class 8th 28.0%, class 9th is 13.3%, and class 6th is 2.7%, and by sex, female is 68.0%, male is 32.0%, by educational background, for the most part, junior college graduates come to 73.3%, by age group 60% of them is in their twenties, 16.0% is in their thirties and forties, 8.0% is in their fifties, and by career after certificate 60% have the career of 1-5 years, 13.3% have the one of 6-7 years or mor than 21 years, and 6.7% have the one of 11-15 years of 16-20 years. 3. All the diagnostic x-ray equipment being kept is 62, and among them flxing equipment is 71.0%, portable equipment is 29.0% and by rating of X-ray equipment, maximum tube current 100 mA is 46.8%, maximum KV 100KVP is 72.6%, the most part. 4. Photofluorographic camera and hood are equipped in every health center. While, as to the radiographic cassettes, $14{\times}14"$ cassetts are equipped in every health center, but cassettes of other sizes are in half of them. 5. Bucky's table is equipped in 11.9% health centers, the automatic processor is in 21.4%, the photofluorographic film changer is 9.5%, the grid is 73.8%, the protective apron is in 88.1%, and the protective glove is in 57.1% health centers. 6. The number of the people who got the x-ray examination for one year (by the year 1989) is the most, 1,000-6,000 in direct radiography of the chest, or 15,0001-45,000 in the health centers of Seoul area, 5,000-20,000 in Kyungki and Inchon area in photofluorography of the chest. Moreover, other radiographies are being taken extremely limitedly in all health centers. 7. In processing types of x-ray film, automatic processing is used in 9 health centers (21.4%), manual tank processing is in 30 (71.4%), and manual tray processing in 3 (7.2%). 8. As for collimation of x-ray exposure field, "continual using restricted by a subject size" has the most part, 78.6% "restricted using at every radiography" has 19%, and the case of "never considered" has 2.4% response. 9. As for the dosimeter used for radiation control, film badge (35.7%) and pocket dosimeter (26.2%) are used, and in 38.1% health centers the dosimeter is not equipped at all. Consideration of the previous radiation exposure is being done in only one health center. 10. Reading of radiographs is mainly depended on the radiologists electively (45.2%) or on the genral practitioners(45.2%).

  • PDF

The Study for Radio Protection According to a Possible Danger of Exposure During dental X-ray Examination (치과 방사선 검사 시 노출 위험성에 따른 피폭선량 방어연구)

  • Lim, Cheong-Hwan;Kim, Seung-Chul;Jung, Hong-Ryang;Hong, Dong-Hee;You, In-Gyu;Jeong, Cheon-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.237-244
    • /
    • 2011
  • Generally, X-ray examinations for dentistry use low energy radiation. It explains that the radiations are mainly absorbed to a human body because of the weak permeability. We made up some counterplans for decrease in radiation exposure, when guardians and radiologists are overexposed owing to unavoidable circumstances. The equipments for the test are GX-770 and CRANEX TOME CEPH which are used for various exams. Besides we measured the radiations in the projection room and in the control room using model 2026c and 20X6-1800. According to the test, the measurement value in the control room was low dose below $20{\mu}R$, the maximum dose in the projection room was $702.8{\mu}R$ and the measurement value of back dose was higher than lateral one. As the result, if we use a shielding door, it's effective for radioprotection and when we didn't prepare protectors, we should secure appropriate distance and be situated at the side area($90{\sim}135^{\circ}$) on the basis of centeral radiation. That way will provide valuable aid for radioprotection.

Study on Usefulness of Entrance Surface Dose (ESD), Entropy Analysis Method to Evaluate Ionization Chamber Performance and Implementation of Optimal Chamber Combination Model when using Automatic Exposure Control (AEC) Device in Digital Radiography (DR) (디지털 방사선 시스템(DR)의 자동노출제어장치 이용 시 이온 챔버의 성능 평가를 위한 엔트로피 분석법의 유용성과 최적의 챔버 조합 모델 구현 연구)

  • Hwang, Jun-Ho;Choi, Ji-An;Lee, Kyung-Bae
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.375-383
    • /
    • 2020
  • This study aimed to propose a methodology for quantitatively analyzing problems resulting from the performance and combination of the ionization chamber when using an automatic exposure control (AEC) and to optimize the performance of the digital radiography (DR). In the experimental method, the X-ray quality of the parameters used for the examination of the abdomen and pelvis was evaluated by percentage average error (PAE) and half value layer (HVL). Then, the stability of the radiation output and the image quality were analyzed by calculating the entrance surface dose (ESD) and entropy when the three ionization chambers were combined. As a result, all of the X-ray quality of the digital radiography used in the experiment showed a percentage average error and a half value layer in the normal range. The entrance surface dose increased in proportion to the combination of chambers, and entropy increased in proportion to the combination of ionization chambers except when three chambers were combined. In conclusion, analysis using entrance surface dose and entropy was found to be a useful method for evaluating the performance and combination problems of the ionization chamber, and the optimal performance of the digital radiography can be maintained when two or less ionization chambers are combined.

The Characteristics and Fates of Pulmonary Tuberculosis Patients Seen at Medical Department of A Medium Sized General Hospital (부산에 한 중형 종합 병원 내과에서의 폐결핵 환자의 양상과 귀결)

  • Kim, Young-Hyo;Park, Ki-Chan;Bae, Seong;Lee, Sang-Hun;Chun, Myung-Ho;Lee, Sang-Ki;Jun, Kwang-Su;Lee, Chan-Se
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.5
    • /
    • pp.417-424
    • /
    • 1992
  • Background: There were many reports about the clinical aspect and outcomes of pulmonary tuberculosis in health center but few in a medium sized general hospital. The purposes of this study were to find any characteristic differencies in the patients and the general outcomes of the treatments and also to give some suggestive points for the insurance policy making. Methods: We made a retrograde analysis of the medical records of 1981 patients (male 992 female 1,059) who attended our clinics of the 4th internal department, Daedong general hospital during two years from January 1989 to December 1990. Result: 1) Of 1981 patients, 96 were diagnosed as pulmonary tuberculosis taking relatively large proportion in the prevalence. The ratio of prevalence between male and female was 7.81% to 2.27%. The 61.46% were the first diagnosis & initial treatment cases and the remaining 38.54% were the retreatment cases with no statistical significance between sex. 2) The most prevalent age group was between 21~40 years old and the prevalence rate was 45.45% of male and 76.76% of female. The lowest age group in male patient was above 61 showed 3.03%, and there was no female patients above age 60 years old. This phenomena could be thought as the negligence for the treatment of pulmonary tuberculosis in the old age groups rather than true tuberculosis prevalence and it could be proved by the higher rates towards old age groups in the national tuberculosis prevalence survey. 3) There were 57.07% of the minimal case, 48.96% of the moderate, 18.75% of the far advanced. The sputum examination showed 37.07% were culture positive, 46.88% were the negative, and 15.63% of the patients had no stutum examination. Moreover, uncoperatives among the far advanced cases were notable showing 22.22% of the stutum examination, where 16.13% in the minimal cases. The stutum positive rate among the initial treatment cases were 41.07% and 55.00% for the retreatment cases. The sputum no examination rates were 17.86% and 12.50% respectively. 4) The classfication of the mode of disease onset showed 68.75% with gradual onset, 9.38% hemoptic, 3.13% acute pneumonic and 18.75% was found through the radiologic examination in various occasions. 5) The percentages of patients who continued their treatment for more than 8 month were 35.71% (for initial treatment), 25.00% (for retrement), 16.13% (for the minimal), 27.78% (for the far advanced). 6) The group of patients who were treated more than 8 months showed the negative conversion rate of 80% on sputum and marked improvement on chest x-ray in 56.67%. However, in far advanced or retreatment cases, the rate of negative conversion on sputum and the rate of improvement on chest x-ray were low being 60% and 20% for the former and 60% and 10% for the latter, each respectively. Conclusion: It would be strongly emphasized that the improvement of National medical insurance system and social welfare system in Korea must be definite to improve overall treatment and control of tuberculosis diseases as well as physician's devotious National tuberculosis control policy.

  • PDF

Clinical Significance of Thoracoscopy on Spontaneous Pneumothorax (자연기흉에 대한 Thoracoscopy 의 임상적의의)

  • Kim, Young-Toe;Kim, Kun-Ho
    • Journal of Chest Surgery
    • /
    • v.8 no.1
    • /
    • pp.19-28
    • /
    • 1975
  • The thoracoscopic study was reported on 21 cases of spontaneous pneumothorax requiring surgical management, and clinical values of thoracoscopic examination on spontaneous pneumothorax were also discussed. patients were treated in the Department of .Thoracic Surgery, Hanyang University Hospital for the period of two Years from May 1972 to April 1974. For exact detection of etiologic factors on spontaneous pneumothorax, the thoracoscopic examination in the intrapleural space was performed in parallel with X-ray study. this study, the difference of diagnostic and therapeutic significance between radiological and thoracoscopic findings were observed and compared simultaneously. The results are summerized as follows: Patients age was distributed between 3 and 70 years old with highest incidence in the age group of sixty decade [33. 3%], and sex ratio of male to female was 5:2. The tuberculous processes which developed superficial subpleural layer in the lung parenchyme, on the pulmonary surface could be observed by thoracoscopic examination in a characteristic picture. detection ratio of pulmonary tuberculosis by the radiologic study to that by thoracoscopy was 8:2. The adhesion between the visceral and the parietal pleura which could possibly make a rupture of the alveola and the visceral pleura was found to be localized in a small area of the lung surface. The other part of the lung surface was free of the adhesion and, therefore, the movement of the lung took place completely without any difficulty. The ruptured orifice of the pleura and pathological changes surrounding the orifice can be detected by thoracoscopy, but not by other means such as radiologic examination. A single tuberculous bleb and multiple emphysematous blebs were found on 6 cases out of 21 cases of spontaneous pneumothorax. Among these cases, radiologic Study revealed the bleb only in one patient. On the other hand, the blebs were found in all the six patients by means of thoracoscopic examination. It gives the detection ratio of bleb by radiologic study to that by thoracoscopy was 1:6. By thoracoscopy, the rupture on the lung surface were visualized on the 10 patients out of a total of 21 patients [10 patients of visual rupture]. However, the rupture of the pleura was not observed on the rest of 11 patients even by thoracoscopic examination [11 patients of non visual rupture]. Five patients [50%] out of ten who had the visual rupture on the lung surface was required a surgical operation to remove pneumothorax. For the patients who were detected to have the visual rupture of the pleura by thoracoscopy, be considered in the early stage of closed thoracostomy. of 21 patients, 16 patients [11 patients of non visual rupture of the pleura and 5 patients of visual rupture of the pleura] who received no surgical management, were treated with closed thoracostomy with continuous suction, and the` pneumothorax was healed completely up in each cases. Therapeutic measures for the remaining 5 patients of visual rupture of the pleura who were subjected to surgical approach for radical treatment of spontaneous pneumothorax were accordingly complicated, and the following different procedures were properly indicated case by case, that is, rib resection thoracostomy, simple closure of ruptured visceral pleura, wedged resection of the lung, and lobectomy.

  • PDF

Survey for Diagnostic Radiography Examination in Veterinary Hospital (동물병원 영상의학적검사 실태조사)

  • Lee, Won-Jeong;Jo, Sung-Mi
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.2
    • /
    • pp.177-184
    • /
    • 2022
  • The purpose of this study is surveyed diagnostic radiography (DR) examination in veterinary hospital (VC) including non-ionization radiation such as ultra-sonography and magnetic resonance imaging. From June 1 to June 20. 2021, we surveyed the VC in 00 metropolitan city by using a structural questionnaire which are location of VC and X-ray unit et al.. Data are expressed as a mean with standard deviation for continuous variable or percent for categorical variable using SPSS ver. 26.0. As the first animal to be visited, dogs were the highest with 61.9%, followed by cats with 12.9%. In 87.1% fo cases, DR units were used, and 4 VCs did not. In 27 VCs using DR units, 48.1% separated examination room and control room, 19.8% examined in animal visited, protective clothing was in all VCs, 55.6% were measured radiation exposure dose, 92.6% was responded a necessary for examination education. From the above results, it will help to revise the guidelines for DR units and examination in korea VCs.

Comparison of $^{67}Ga$ Planar Imaging and SPECT for the Evaluation of Activity in Undetermined Minimal Pulmonary Tuberculosis (흉부 X-선상 활동성 미정으로 판독된 경증 폐결핵 환자에서 활동성 판정에 대한 $^{67}Ga$ 평면영상과 SPECT의 비교분석)

  • An, Min;Chang, Won-Kyu;Kim, Kyoung-Gon;Kim, Sung-Min;Kim, Yun-Kwon;Kim, So-Yeon;Kim, Young-Jung;Park, Byung-Yik;Cho, Min-Koo;Lee, Gwon-Jun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.6
    • /
    • pp.870-878
    • /
    • 2000
  • Background : We have studied the $^{67}Ga$ SPECT to determine the activity of pulmonary tuberculosis, especially in patients with minimal extent of the disease on chest radiographs. Because active minimal pulmonary tuberculosis is sometimes difficult to diagnose by means of initial chest X-ray, sputum examination and $^{67}Ga$ planar imaging, we compared $^{67}Ga$ planar imaging with SPECT to evaluate minimal pulmonary tuberculosis activity. Methods : $^{67}Ga$ planar imagings and SPECTs of 69 patients suspected of minimal pulmonary tuberculosis by the initial chest X-ray were performed and compared to each other. Active pulmonary tuberculosis was defined by a positive AFB smear and/or culture in the sputum and changes shown on the serial chest X-ray findings. Results : 1) $^{67}Ga$ planar imaging imagings showed positive uptakes in 24 patients and no uptakes in 13 patients, patients, which confirms active pulmonary tuberculosis. But SPECT imagings showed positive uptakes in 25 patients and no uptakes in 12 patients. 2) Patients confirmed with inactive pulmonary tuberculosis showed no uptake on $^{67}Ga$ planar imaging. Only one of the 32 patients confirmed as having inactive pulmonary tuberculosis showed positive uptake on $^{67}Ga$ SPECT imaging. Conclusions : According to the results of our study, $^{67}Ga$ planar imaging and SPECT are both sensitive in detecting the activity of minimal pulmonary tuberculosis. The difference between the two methods is not statistically significant, and the negative predictive value of the $^{67}Ga$ SPECT is not higher than that of $^{67}Ga$ planar imaging.

  • PDF

Evaluating the Reduction of Spatial Scattering based on Lead-free Radiation Shielding Sheet using MCNPX Simulation (MCNPX 시뮬레이션을 이용한 무납 방사선 차폐 시트 기반의 공간산란 저감화 평가)

  • Yang, Seung u;Park, Geum-byeol;Heo, Ye Ji;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.367-373
    • /
    • 2020
  • Most of the spatial scattered dose caused by the scattered rays generated by the collision between the object and X-rays is relatively easily absorbed by the human body as electromagnetic waves in the low energy region, thereby increasing the degree of radiation exposure. Such spatial scattering dose is also used as an indicator of the degree of radiation exposure of radiation workers and patients, and there is a need for a method to reduce exposure by reducing the spatial scattered dose that occurs indirectly. Therefore, in this study, a lead-free radiation shielding sheet was proposed as a way to reduce the spatial scattering dose, and a Monte Carlo (MC) simulation was performed based on a chest X-ray examination. The absorbed dose was calculated and the measured value and the shielding rate were compared and evaluated.

Reduction of Radiation Exposure Dose of Eyeball and Thyroid for Chest and Abdomen CT Scan (흉부 및 복부 CT 검사 시 안구와 갑상선의 방사선 피폭선량 저감)

  • Lee, Jun Seok;Chon, Kwon Su
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.2
    • /
    • pp.147-151
    • /
    • 2019
  • In chest and abdomen CT scans, the radiation exposure doses by scattering lines were measured at the eyeball and thyroid. Radiation exposure was investigated by using shielding devices. The chest and abdomen CT scan protocols used in the real examination were applied to measure and compare radiation doses before and after the use of shielding devices at the eyeball and the thyroid. The radiaton doses were measured with OSLD dosimeters. Barium, tungsten sheets, goggles and neck shields were used to protect the scattered X-ray. The chest CT scans showed respectively 3.01 mSv and 6.21 mSv at the eyeball and the thyroid by the scattered X-ray. The abdomen CT scans showed 0.55 mSv and 3.22 mSv for the eyeball and the thyroid respectively. Barium and tungsten sheets had 11% to 13% protection rates at the eyeball and the thyroid for chest CT scan, and 34% to 49% reduction in radiation dose for the abdomen CT scan. Because of the significant radiation dose, which causes cataracts and thyroid cancer by the repeated and continuous radiation exposure, for the chest and the abdomen CT scans, it is required to use shielding devices to reduce radiation dose for examinations.