• Title/Summary/Keyword: X-ray Computed

Search Result 793, Processing Time 0.02 seconds

Appendiceal Visualization on 2-mSv CT vs. Conventional-Dose CT in Adolescents and Young Adults with Suspected Appendicitis: An Analysis of Large Pragmatic Randomized Trial Data

  • Jungheum Cho;Youngjune Kim;Seungjae Lee;Hooney Daniel Min;Yousun Ko;Choong Guen Chee;Hae Young Kim;Ji Hoon Park;Kyoung Ho Lee;LOCAT Group
    • Korean Journal of Radiology
    • /
    • v.23 no.4
    • /
    • pp.413-425
    • /
    • 2022
  • Objective: We compared appendiceal visualization on 2-mSv CT vs. conventional-dose CT (median 7 mSv) in adolescents and young adults and analyzed the undesirable clinical and diagnostic outcomes that followed appendiceal nonvisualization. Materials and Methods: A total of 3074 patients aged 15-44 years (mean ± standard deviation, 28 ± 9 years; 1672 female) from 20 hospitals were randomized to the 2-mSv CT or conventional-dose CT group (1535 vs. 1539) from December 2013 through August 2016. A total of 161 radiologists from 20 institutions prospectively rated appendiceal visualization (grade 0, not identified; grade 1, unsure or partly visualized; and grade 2, clearly and entirely visualized) and the presence of appendicitis in these patients. The final diagnosis was based on CT imaging and surgical, pathologic, and clinical findings. We analyzed undesirable clinical or diagnostic outcomes, such as negative appendectomy, perforated appendicitis, more extensive than simple appendectomy, delay in patient management, or incorrect CT diagnosis, which followed appendiceal nonvisualization (defined as grade 0 or 1) and compared the outcomes between the two groups. Results: In the 2-mSv CT and conventional-dose CT groups, appendiceal visualization was rated as grade 0 in 41 (2.7%) and 18 (1.2%) patients, respectively; grade 1 in 181 (11.8%) and 81 (5.3%) patients, respectively; and grade 2 in 1304 (85.0%) and 1421 (92.3%) patients, respectively (p < 0.001). Overall, undesirable outcomes were rare in both groups. Compared to the conventional-dose CT group, the 2-mSv CT group had slightly higher rates of perforated appendicitis (1.1% [17] vs. 0.5% [7], p = 0.06) and false-negative diagnoses (0.4% [6] vs. 0.0% [0], p = 0.01) following appendiceal nonvisualization. Otherwise, these two groups were comparable. Conclusion: The use of 2-mSv CT instead of conventional-dose CT impairs appendiceal visualization in more patients. However, appendiceal nonvisualization on 2-mSv CT rarely leads to undesirable clinical or diagnostic outcomes.

Three-Dimensional Printed Model of Partial Anomalous Pulmonary Venous Return with Biatrial Connection (양측 심방 연결을 형성하는 부분 폐정맥 환류 이상의 3D 프린팅 모델)

  • Myoung Kyoung Kim;Sung Mok Kim;Eun Kyoung Kim;Sung-A Chang;Tae-Gook Jun;Yeon Hyeon Choe
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.6
    • /
    • pp.1523-1528
    • /
    • 2020
  • Partial anomalous pulmonary venous return (PAPVR) is a rare congenital cardiac anomaly that can be difficult to detect and often remains undiagnosed. PAPVR is diagnosed using non-invasive imaging techniques such as echocardiography, CT, and MRI. Image data are reviewed on a 2-dimensional (D) monitor, which may not facilitate a good understanding of the complex 3D heart structure. In recent years, 3D printing technology, which allows the creation of physical cardiac models using source image datasets obtained from cardiac CT or MRI, has been increasingly used in the medical field. We report a case involving a 3D-printed model of PAPVR with a biatrial connection. This model demonstrated separate drainages of the right upper and middle pulmonary veins into the lower superior vena cava (SVC) and the junction between the SVC and the right atrium, respectively, with biatrial communication through the right middle pulmonary vein.

Layered structure of sialoliths compared with tonsilloliths and antroliths

  • Buyanbileg Sodnom-Ish;Mi Young Eo;Yun Ju Cho;Mi Hyun Seo;Hyeong-Cheol Yang;Min-Keun Kim;Hoon Myoung;Soung Min Kim
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.50 no.1
    • /
    • pp.13-26
    • /
    • 2024
  • Objectives: The aim of this study was to perform a comparative analysis of the ultrastructural and chemical composition of sialoliths, tonsilloliths, and antroliths and to describe their growth pattern. Materials and Methods: We obtained 19 specimens from 18 patients and classified the specimens into three groups: sialolith (A), tonsillolith (B), and antrolith (C). The peripheral, middle, and core regions of the specimens were examined in detail by histology, micro-computed tomography (micro-CT), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy, and transmission electron microscopy (TEM). Results: In the micro-CT, group A showed alternating radiodense and radiolucent layers, while group B had a homogeneous structure. Group C specimens revealed a compact homogeneous structure. Histopathologically, group A showed a laminated, teardrop-shaped, globular structure. Group B demonstrated degrees of immature calcification of organic and inorganic materials. In group C, the lesion was not encapsulated and showed a homogeneous lamellar bone structure. SEM revealed that group A showed distinct three layers: a peripheral multilayer zone, intermediate compact zone, and the central nidus area; groups B and C did not show these layers. The main elemental components of sialoliths were O, C, Ca, N, Cu, P, Zn, Si, Zr, F, Na, and Mg. In group B, a small amount of Fe was found in the peripheral region. Group C had a shorter component list: Ca, C, O, P, F, N, Si, Na, and Mg. TEM analysis of group A showed globular structures undergoing intra-vesicular calcification. In group B, bacteria were present in the middle layer. In the outer layer of the group C antrolith, an osteoblastic rimming was observed. Conclusion: Sialoliths had distinct three layers: a peripheral multilayer zone, an intermediate compact zone and the central nidus area, while the tonsillolith and antrolith specimens lacked distinct layers and a core.

Expert Opinion Questionnaire About Chest CT Scan Using A Negative Pressure Isolation Strecher in COVID-19 Patients: Image Quality and Infection Risk (COVID-19 환자에서 음압격리들것을 이용한 흉부 CT 검사에 대한 전문가 의견 설문: 영상품질과 감염위험)

  • Kwang Nam Jin;Bo Da Nam;Jaemin Shin;Sung Ho Hwang
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.4
    • /
    • pp.891-899
    • /
    • 2023
  • Purpose To survey perceptions of certified physicians on the protocol of chest CT in patients with coronavirus (COVID-19) using a negative pressure isolation stretcher (NPIS). Materials and Methods This study collected questionnaire responses from a total of 27 certified physicians who had previously performed chest CT with NPIS in COVID-19 isolation hospitals. Results The nine surveyed hospitals performed an average of 116 chest CT examinations with NPIS each year. Of these, an average of 24 cases (21%) were contrast chest CT. Of the 9 pulmonologists we surveyed, 5 (56%) agreed that patients who showed abnormalities in serum D-dimer required contrast chest CT. All 9 surveyed radiologists agreed that the image quality of the chest CT with NPIS was sufficient for CT image interpretation regarding pneumonia or pulmonary embolism. Furthermore, in our 9 surveyed infectionologists, 5 (56%) agreed that a risk of secondary infection in the CT room after temporary opening of NPIS could be prevented through a process of disinfection. Conclusion Experienced physicians considered that the effects of NIPS on chest CT image quality was minimal in patients with COVID-19, and the risk of CT room contamination was easily controlled.

Imaging and Clinical Findings of Xanthogranulomatous Inflammatory Disease of Various Abdominal and Pelvic Organs: A Pictorial Essay (복부와 골반의 다양한 장기에서 발생한 황색육아종성 염증 질환의 영상 및 임상 소견: 임상화보)

  • Se Jin Lee;Dal Mo Yang;Hyun Cheol Kim;Sang Won Kim;Kyu Yeoun Won;So Hyun Park;Woo Kyoung Jeong
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.109-123
    • /
    • 2024
  • Xanthogranulomatous (XG) inflammatory disease is a rare benign disease involving various organs, including the gallbladder, bile duct, pancreas, spleen, stomach, small bowel, colon, appendix, kidney, adrenal gland, urachus, urinary bladder, retroperitoneum, and female genital organs. The imaging features of XG inflammatory disease are nonspecific, usually presenting as a heterogeneous solid or cystic mass. The disease may also extend to adjacent structures. Due to its aggressive nature, it is occasionally misdiagnosed as a malignant neoplasm. Herein, we review the radiological features and clinical manifestations of XG inflammatory diseases in various organs of the abdomen and pelvis.

National Trends in Pediatric CT Scans in South Korea: A Nationwide Cohort Study (소아 전산화단층촬영의 국내 동향: 전국적 코호트 연구)

  • Nak Tscheol Kim;Soon-Sun Kwon;Moon Seok Park;Kyoung Min Lee;Ki Hyuk Sung
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.1
    • /
    • pp.138-148
    • /
    • 2022
  • Purpose This study evaluated the rates and annual trends of pediatric CT scans in South Korea using a nationwide population-based database. Materials and Methods Data regarding pediatric CT scan usage between 2012 and 2017 were retrieved from the health insurance review and assessment service. Data on the age, sex, diagnosis, and the anatomical area of involved patients were also extracted. Results A total of 576376 CT examinations were performed among 58527528 children aged below 18 years (9.8 scans/1000 children), and the number of CT examinations per 1000 children was noted to have increased by 23.2% from 9.0 in 2012 to 11.0 in 2017. Specifically, the number of CT examinations increased by 32.9% for the 6-12 years of age group (7.4/1000 to 9.8/1000) and by 34.0% for the 13-18 years of age group (11.4/1000 to 15.3/1000). Moreover, majority of the CT scans were limited to the head (39.1%), followed by the extremities (32.5%) and the abdomen (13.7%). Notably, the number of extremity CT scans increased by 83.6% (2.3/1000 to 4.2/1000), and its proportion as compared to other scans increased from 25.3% to 37.7%. Conclusion CT scans in the pediatric population increased continuously from 2012 to 2017 at an annual rate of 4.4%. Therefore, physicians should balance the benefits of CT with its potential harms from associated radiation exposure in pediatric patients.

Adaptation of Deep Learning Image Reconstruction for Pediatric Head CT: A Focus on the Image Quality (소아용 두부 컴퓨터단층촬영에서 딥러닝 영상 재구성 적용: 영상 품질에 대한 고찰)

  • Nim Lee;Hyun-Hae Cho;So Mi Lee;Sun Kyoung You
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.240-252
    • /
    • 2023
  • Purpose To assess the effect of deep learning image reconstruction (DLIR) for head CT in pediatric patients. Materials and Methods We collected 126 pediatric head CT images, which were reconstructed using filtered back projection, iterative reconstruction using adaptive statistical iterative reconstruction (ASiR)-V, and all three levels of DLIR (TrueFidelity; GE Healthcare). Each image set group was divided into four subgroups according to the patients' ages. Clinical and dose-related data were reviewed. Quantitative parameters, including the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR), and qualitative parameters, including noise, gray matter-white matter (GM-WM) differentiation, sharpness, artifact, acceptability, and unfamiliar texture change were evaluated and compared. Results The SNR and CNR of each level in each age group increased among strength levels of DLIR. High-level DLIR showed a significantly improved SNR and CNR (p < 0.05). Sequential reduction of noise, improvement of GM-WM differentiation, and improvement of sharpness was noted among strength levels of DLIR. Those of high-level DLIR showed a similar value as that with ASiR-V. Artifact and acceptability did not show a significant difference among the adapted levels of DLIR. Conclusion Adaptation of high-level DLIR for the pediatric head CT can significantly reduce image noise. Modification is needed while processing artifacts.

Imaging for Multiple Myeloma according to the Recent International Myeloma Working Group Guidelines: Analysis of Image Acquisition Techniques and Response Evaluation in Whole-Body MRI according to MY-RADS (International Myeloma Working Group의 최신 가이드 라인에 따른 다발성 골수종의 영상검사법 및 MY-RADS에 따른 전신 MRI에서의 영상 획득과 반응 평가 소개)

  • A Yeon Son;Hye Won Chung
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.150-169
    • /
    • 2023
  • Multiple myeloma (MM) is a malignant hematologic disease caused by the proliferation of clonal plasma cells in the bone marrow, and its incidence is increasing in Korea. With the development of treatments for MM, the need for early diagnosis and treatment has emerged. In recent years, the International Myeloma Working Group (IMWG) has been constantly revising the laboratory and radiological diagnostic criteria for MM. In addition, as whole-body MRI (WBMR) has been increasing used in the diagnosis and treatment response evaluation of patients with MM, the Myeloma Response Assessment and Diagnosis System (MY-RADS) was created to standardize WBMR image acquisition techniques, image interpretation, and response evaluation methods. Radiologists need to have a detailed knowledge of the features of MM for accurate diagnosis. Thus, in this review article, we describe the imaging method for MM according to the latest IMWG guidelines as well as the image acquisition and response evaluation technique for WBMR according to MY-RADS.

Added Value of Structured Reporting for US of the Pediatric Appendix: Additional CT Examinations and Negative Appendectomy (소아 충수 초음파 검사에서 구조화 판독문의 부가가치: 추가 CT 검사 및 음성 충수절제술의 관점에서)

  • Keonwoo Choi;Ji Young Choi;Hyuk Jung Kim;Hyun Jin Kim;Suk Ki Jang
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.653-662
    • /
    • 2023
  • Purpose This study aimed to determine the incremental value of using a structured report (SR) for US examinations of the pediatric appendix. Materials and Methods Between January 2009 and June 2016, 1150 pediatric patients with suspected appendicitis who underwent US examinations of the appendix were included retrospectively. In November 2012, we developed a five-point scale SR for appendix US examinations. The patients were divided into two groups according to the form of the US report: free-text or SR. The primary clinical outcomes were compared between the two groups, including the rate of CT imaging following US examinations, the negative appendectomy rate (NAR), and the appendiceal perforation rate (PR). Results In total, 550 patients were included in the free-text group and 600 patients in the SR group. The rate of additional CT examinations decreased by 5.3% in the SR group (8.2%, p = 0.003), and the NAR decreased by 8.4% in the SR group (7.8%, p = 0.028). There was no statistical difference in the appendiceal PR (37.6% vs. 48.0%, p = 0.078). Conclusion The use of an SR to evaluate US examinations for suspected pediatric appendicitis results in lower CT use and fewer negative appendectomies without an increase in appendiceal PR.

Tissue Adequacy and Safety of Percutaneous Transthoracic Needle Biopsy for Molecular Analysis in Non-Small Cell Lung Cancer: A Systematic Review and Meta-analysis

  • Bo Da Nam;Soon Ho Yoon;Hyunsook Hong;Jung Hwa Hwang;Jin Mo Goo;Suyeon Park
    • Korean Journal of Radiology
    • /
    • v.22 no.12
    • /
    • pp.2082-2093
    • /
    • 2021
  • Objective: We conducted a systematic review and meta-analysis of the tissue adequacy and complication rates of percutaneous transthoracic needle biopsy (PTNB) for molecular analysis in patients with non-small cell lung cancer (NSCLC). Materials and Methods: We performed a literature search of the OVID-MEDLINE and Embase databases to identify original studies on the tissue adequacy and complication rates of PTNB for molecular analysis in patients with NSCLC published between January 2005 and January 2020. Inverse variance and random-effects models were used to evaluate and acquire meta-analytic estimates of the outcomes. To explore heterogeneity across the studies, univariable and multivariable metaregression analyses were performed. Results: A total of 21 studies with 2232 biopsies (initial biopsy, 8 studies; rebiopsy after therapy, 13 studies) were included. The pooled rates of tissue adequacy and complications were 89.3% (95% confidence interval [CI]: 85.6%-92.6%; I2 = 0.81) and 17.3% (95% CI: 12.1%-23.1%; I2 = 0.89), respectively. These rates were 93.5% and 22.2% for the initial biopsies and 86.2% and 16.8% for the rebiopsies, respectively. Severe complications, including pneumothorax requiring chest tube placement and massive hemoptysis, occurred in 0.7% of the cases (95% CI: 0%-2.2%; I2 = 0.67). Multivariable meta-regression analysis showed that the tissue adequacy rate was not significantly lower in studies on rebiopsies (p = 0.058). The complication rate was significantly higher in studies that preferentially included older adults (p = 0.001). Conclusion: PTNB demonstrated an average tissue adequacy rate of 89.3% for molecular analysis in patients with NSCLC, with a complication rate of 17.3%. PTNB is a generally safe and effective diagnostic procedure for obtaining tissue samples for molecular analysis in NSCLC. Rebiopsy may be performed actively with an acceptable risk of complications if clinically required.