• Title/Summary/Keyword: X-ray 시스템

Search Result 499, Processing Time 0.027 seconds

Development of a Portable Device Based Wireless Medical Radiation Monitoring System (휴대용 단말 기반 의료용 무선 방사선 모니터링 시스템 개발)

  • Park, Hye Min;Hong, Hyun Seong;Kim, Jeong Ho;Joo, Koan Sik
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.3
    • /
    • pp.150-158
    • /
    • 2014
  • Radiation-related practitioners and radiation-treated patients at medical institutions are inevitably exposed to radiation for diagnosis and treatment. Although standards for maximum doses are recommended by the International Commission on Radiological Protection (ICPR) and the International Atomic Energy Agency (IAEA), more direct and available measurement and analytical methods are necessary for optimal exposure management for potential exposure subjects such as practitioners and patients. Thus, in this study we developed a system for real-time radiation monitoring at a distance that works with existing portable device. The monitoring system comprises three parts for detection, imaging, and transmission. For miniaturization of the detection part, a scintillation detector was designed based on a silicon photomultiplier (SiPM). The imaging part uses a wireless charge-coupled device (CCD) camera module along with the detection part to transmit a radiation image and measured data through the transmission part using a Bluetooth-enabled portable device. To evaluate the performance of the developed system, diagnostic X-ray generators and sources of $^{137}Cs$, $^{22}Na$, $^{60}Co$, $^{204}Tl$, and $^{90}Sr$ were used. We checked the results for reactivity to gamma, beta, and X-ray radiation and determined that the error range in the response linearity is less than 3% with regard to radiation strength and in the detection accuracy evaluation with regard to measured distance using MCNPX Code. We hope that the results of this study will contribute to cost savings for radiation detection system configuration and to individual exposure management.

High Frequency High Voltage 40kW Power System for Diagnosis X-ray (진단 X-선용 40kW 고주파 고압 전원 시스템)

  • Kim Hack-Seong;Park Young-Kuk;Oh Jun-Yong;Sung Ki-Bong
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.249-252
    • /
    • 2002
  • 최근 수년동안 의료 X-선 장비의 고전압 발생용 전원장치는 고주파 인버터 형태로의 개발이 가속화되어 단시간 촬영의 고성능화와 장치의 소형화 그리고 고전압 리플의 저감에 따른 피폭량 감소가 실현되고 있다. 본 논문은 이에 따른 의료 진단용 X-선 발생 시스템에서 40kW(125kV, 800mA)급 고주파 전원 발생장치 개발에 관한 것으로 고주파 고전압 인버터, 고주파 고전압 변압기를 포함한 고전압 발생 회로, X-선 관전압, 관전류 제어부, 시스템 구동부의 설계 개발에 대하여 기술하였고, 전체 구성된 시스템의 실험 파형에 따른 동작 특성을 제시하였다.

  • PDF

A Study on artificial lighting source using X3D (X3D를 이용한 인공조명에 관한 연구)

  • Park, Gyung-Bae;Kang, Kyung-In
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.3
    • /
    • pp.111-119
    • /
    • 2010
  • An artificial light source has a character that a light emits from a point to all directions with many radial and straight ray shapes. It is very difficult and complex to render those emitting lights. Also, users have difficulty in expressing exactly 3D objects because of colors varying with changing of a light and having many parameters. In this paper, to solve those problems we design an artificial light source using X3D to create a model that represents easily many radial and straight ray shapes and propose the online system that each factors of colors to be reflected by a light is separated and then users can control them to detect object's colors by a mouse. Various light sources with reality can be easily created using proposed system.

Deep Learning-based Spine Segmentation Technique Using the Center Point of the Spine and Modified U-Net (척추의 중심점과 Modified U-Net을 활용한 딥러닝 기반 척추 자동 분할)

  • Sungjoo Lim;Hwiyoung Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.2
    • /
    • pp.139-146
    • /
    • 2023
  • Osteoporosis is a disease in which the risk of bone fractures increases due to a decrease in bone density caused by aging. Osteoporosis is diagnosed by measuring bone density in the total hip, femoral neck, and lumbar spine. To accurately measure bone density in the lumbar spine, the vertebral region must be segmented from the lumbar X-ray image. Deep learning-based automatic spinal segmentation methods can provide fast and precise information about the vertebral region. In this study, we used 695 lumbar spine images as training and test datasets for a deep learning segmentation model. We proposed a lumbar automatic segmentation model, CM-Net, which combines the center point of the spine and the modified U-Net network. As a result, the average Dice Similarity Coefficient(DSC) was 0.974, precision was 0.916, recall was 0.906, accuracy was 0.998, and Area under the Precision-Recall Curve (AUPRC) was 0.912. This study demonstrates a high-performance automatic segmentation model for lumbar X-ray images, which overcomes noise such as spinal fractures and implants. Furthermore, we can perform accurate measurement of bone density on lumbar X-ray images using an automatic segmentation methodology for the spine, which can prevent the risk of compression fractures at an early stage and improve the accuracy and efficiency of osteoporosis diagnosis.

Combined X-ray CT/SPECT System with a Common CZT Detector (CZT검출기를 이용한 CT/SPECT 조합영상시스템)

  • 권수일
    • Progress in Medical Physics
    • /
    • v.13 no.4
    • /
    • pp.229-233
    • /
    • 2002
  • We have tested a combined CT/SPECT system with a single CZT detector for x-ray and gamma-ray medical imaging. The size of detector is 10$\times$10$\times$5 ㎣, and the anodes are pixellated as a 4$\times$4 array with a pixel dimension of $1.5\times$1.5 $\textrm{mm}^2$. The cathode was coated with a continuous Au-plated. We have characterized the system performance by scanning a radiographic resolution phantom and the Hoffman Brain phantom. Pulse counting electronics with very short shaping time (50 ㎱) are used to satisfy high photon rates in x-ray imaging, and response linearity up to 3$\times$10$^{5}$ counts per second per detector element is achieved. Energy resolution of 10.4% and 5.3% FWHM at Tc-99m 140 keV peak are obtained for the 50 ㎱ and 2 $mutextrm{s}$ shaping times, respectively. The spatial resolutions of CT and SPECT are about 1mm and 9mm, respectively. Photopeak efficiency of detector systems are 41.0% for 50㎱ and 72.5% for 2 $mutextrm{s}$ shaping time.

  • PDF

Study on Talbot Pattern for Grating Interferometer (격자간섭계를 위한 탈봇 패턴 연구)

  • Kim, Youngju;Oh, Ohsung;Kim, Jongyul;Lee, Seung Wook
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.39-49
    • /
    • 2015
  • One of properties which X-ray and Neutron can be applied nondestructive test is penetration into the object with interaction leads to decrease in intensity. X-ray interaction with the matter caused by electrons, Neutron caused by atoms. They share applications in nondestructive test area because of their similarities of interaction mechanism. Grating interferometer is the one of applications produces phase contrast image and dark field image. It is defined by Talbot interferometer and Talbot-Lau interferometer according to Talbot effect and Talbot-Lau effect respectively. Talbot interferometer works with coherence beam like X-ray, and Talbot-Lau has an effect with incoherence beam like Neutron. It is important to expect the interference in grating interferometer compared normal nondestructive system. In this paper, simulation works are conducted according to Talbot and Talbot-Lau interferometer in case of X-ray and Neutron. Variation of interference intensity with X-ray and Neutron based on wave theory is constructed and calculate elements consist the system. Additionally, Talbot and Talbot-Lau interferometer is simulated in different kinds of conditions.

BLDC Motor Control Unit for Automation of X ray Equipment (X선 기기의 자동화를 위한 BLDC 모터 제어 장치)

  • Kim, Tae-Gon;Kim, Young-Pyo;Cheon, Min-Woo
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.5
    • /
    • pp.833-838
    • /
    • 2011
  • X-ray device used in the diagnosis has made possible to have more effective and accurate diagnosis, powered by the development of various devices. Based on this, X-ray device has become the most basic and essential diagnostic equipment in clinical medicine. At present, in the image acquisition field using X-ray, the use of Digital radiography which is useful in the acquisition time reduction and transfer of images and is possible to have the dose reduction has expanded. With the structure using one detector, this DR device has disadvantages in that it needs structural changes unlike existing X-ray and the detector should be moved to the desired position depending on the shooting location. Therefore, in this study, using BLDC(Brushless direct current) motor and PID(Proportional integral differential) control method, the automatic control system of 3-axis which is upward and downward, left and right and rotation of detector where having the most movement in DR was designed and produced and its performance was evaluated.

Effect of Field Size on the Clinical Exposure Index for Lumbar Spine X-ray Examination (노출지수를 이용한 요추 X선 촬영의 조사야 유효성 평가)

  • Park, Hyemin;Yoon, Yongsu;Kim, Jungsu;Jeong, Hoiwoun
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.183-187
    • /
    • 2021
  • The field size of the lumbar spine X-ray examination, which belongs to the most frequent examination in general radiography, is 5 times wider than the width of the lumbar spine. Exposure index (EI) as per International Electrotechnical Commission has a proportional relationship with the dose incident on the image receptor for clinical protocols in addition to RQA5, which is a calibration beam quality. In this study, the effectiveness of the set field size was evaluated through the change of EI according to the size of field during lumbar spine X-ray examinations. Lumbar anterior-posterior and lateral examinations was performed using a whole-body phantom, and the national average exposure conditions of Korea investigated in 2017 were introduced for the X-ray exposure. As a result of comparing the EI displayed on the console of digital radiography system for the three field size in ① 18 × 36 cm2 ② 25 × 36 cm2 ③ 36 × 36 cm2, the EI values showed a tendency to increase as the field size increased. Since the patient dose, such as organ dose around the lumbar spine, increases as the field size becomes larger, thus, if the EI obtained from the field size at a level that does not interfere with diagnosis is set as a reference, the effectiveness of the field size can be evaluated through the EI displayed on the console when the lumbar spine X-ray examination is conducted.

Development of Laser-based X-ray Microscope System for Biomedical Application (레이저 기반의 생체의료용 X-선 현미경 시스템 개발)

  • 윤권하
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.110-111
    • /
    • 2003
  • 금세기는 ‘광의 시대’이며, 그 중에서도 앞으로 발전이 가장 기대되는 부분은 X-선을 응용한 과학·기술이다. 그것을 다루는 학문분야의 하나가 X-선 결상광학이고, 이 분야에서는 가시광선과는 다른 특수한 광학소자와 광학계 및 검출기가 필요하다. 생명체에 대한 보다 많은 정보를 얻기위해 인간은 미세 세포에 대한 연구를 추구하여 왔고, 미세 세포에 대한 연구를 보다 정밀하고 살아있는 생체 상태로 관측할 수 있는 가장 좋은 도구중의 하나가 물의 창 영역(λ=2.3∼4.4nm)의 연 X-선 현미경이다. (중략)

  • PDF

A Study on the Resolution Analysis of Digital X-ray Images with increasing Thickness of PMMA (조직 등가물질 두께 증가에 따른 디지털 엑스선 영상의 해상도 분석에 관한 연구)

  • Kim, Junwoo
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.173-179
    • /
    • 2021
  • Scattered x-ray generated by digital radiography systems also have the advantage of increasing signals, but ultimately detectability is reduced by decreasing resolution and increasing noise of x-ray images transmitted objects. An indirect method of measuring scattered x-ray in a modulation-transfer function (MTF) for evaluating resolution in a spatial-frequency domain can be considered as a drop in the MTF value corresponding to zero-frequency. In this study, polymethyl methacrylate (PMMA) was used as a patient tissue equivalent, and MTFs were obtained for various thicknesses to quantify the effect of scattered x-ray on resolution. X-ray image signals were observed to decrease by 35 ~ 83% with PMMA thickness increasing, which is determined by the absorption or scattering of x-rays in PMMA, resulting in reduced MTF and increased scatter fraction. The method to compensate for MTF degradation by PMMA resulted in the MTF inflation without considering the optical spreading generated by the indirect-conversion type detector. Data fitting or zero-padding are needed to compensate for MTF more reasonably on edge-spread function or line-spread function.