• Title/Summary/Keyword: X-ray 시스템

Search Result 499, Processing Time 0.042 seconds

Evaluation of the Filling Sodium States Inside the Fuel rod of Sodium-Cooled Fast Reactor by Optimized Spatial Resolution in Medical Digital Radiographic Images (의료용 디지털방사선영상의 공간분해능 최적화에 의한 소듐냉각고속로 연료봉 내부의 소듐 충전상태 평가)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.2
    • /
    • pp.117-124
    • /
    • 2016
  • The purpose of this study was tried to evaluate the filling sodium states inside the fuel rod of sodium-cooled fast reactor by digital medical X-ray. We used the diagnostic X-ray generators in digital radiography (DR). This study have found the optimal conditions by changing the effective focal spot size of X-ray tube and post-processing of the DR method with a tungsten edge plate in order to ensure excellent sharpness At this time, the sharpness and resolution were evaluated using the MTF (modulation transfer function). As a result, this study obtained a spatial resolution of 3.871 lp/mm (0.1 MTF), 3.290 lp/mm (0.5 MTF) when implemented the contrast strengthen post-processing in small focal spot. In this research, the result is able to evaluate the level of sodium inside the fuel rod by using the diagnostic X-ray generators in medical digital radiographic images.

Comparison of three digital radiographic imaging systems for the visibility of endodontic files (근관 파일의 인지도 평가시 세 가지 디지털 방사선영상시스템의 비교)

  • Park Jong-Won;Kim Eun-Kyung;Han Won-Jeong
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.145-150
    • /
    • 2004
  • Purpose: To compare three digital radiographic imaging sensors by evaluating the visibility of endodontic file tips with interobserver reproducibility and assessing subjectively the clarity of images in comparison with the x-ray film images. Materials and Methods: Forty-five extracted sound premolars were used for this study. Fifteen plaster blocks were made with three premolars each and #8, 10, 15 K-flexofiles were inserted into the root canal of premolars. They were radiographically exposed using periapical x-ray films (Kodak Insight Dental film, Eastmann Kodak company, Rochester, USA), Digora imaging plates (Soredex-Orion Co., Helsinki, Finland), CDX 2000HQ sensors (Biomedisys Co., Seoul, Korea), and CDR sensors (Schick Inc., Long Island, USA). The visibility of endodontic files was evaluated with interobserver reproducibility, which was calculated as the standard deviations of X, Y coordinates of endodontic file tips measured on digital images by three oral and maxillofacial radiologists. The clarity of images was assessed subjectively using 3 grades, i.e. plus, equal, and minus in comparison with the conventional x-ray film images. Results: Interobserver reproducibility of endodontic file tips was the highest in CDR sensor (p < 0.05) only except at Y coordinates of #15 file. In the subjective assessment of the image clarity, the plus grade was the most frequent in CDR sensor at all size of endodontic file (p < 0.05). Conclusion : CDR sensor was the most superior to the other sensors, CDX 2000HQ sensor and Digora imaging plate in the evaluation of interobserver reproducibility of endodontic file tip and subjective assessment of image clarity.

  • PDF

An Iterative Method for Flat-Field Correction of Digital Radiography When Detector is at Any Position (반복적인 방법을 이용한 임의의 DR detector 위치에서의 flat field correction 방법 연구)

  • Kim, Do-Il;Lee, Hyoung-Koo;Kim, Sung-Hyeon;Park, Dae-Sop;Choe, Bo-Young;Suh, Tae-Suk
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.64-66
    • /
    • 2004
  • When examing patients with DRs it is necessary to remove bad pixels and lines and to correct non-uniform offsets and x-ray field. For non-uniformity correction a flat field x-ray image is needed, and to obtain it the center of detector is usually aligned with the focal spot of the x-ray tube, which is conserved when examing patients to preserve the flat field. In some of radiographic techniques, however, it is necessary to move the x-ray tube off the center position of detector or tilt the detector. We investigated the effect of detector tilting on the non-uniformity correction, and propose a method to reduce the effect using a new algorithm. The flat field of X-ray in the DR detector could be guaranteed with this result.

  • PDF

Conversion of Radiology Report into DICOM SR (의료 영상 판독 결과의 DICOM SR 변환)

  • Kim Yong-Soo;Shin Seung-Yong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.3 s.35
    • /
    • pp.331-337
    • /
    • 2005
  • 'Supplement 23:DICOM SR' announced on April 2000 made possible co-relations between the clinical reports and human body parts by standardizing the exchange of clinical information. DICOM SR uses its own coding schemes and values to represent information, which convey hierarchically structured content items. This paper analyzes radiology reports produced in HIS(Hospital Information System) and categorizes content structures into three parts such as, finding, conclusion, and recommendation, and implements a system which can be used by clinicians. Digital X-ray images and their reports have been managed separately. Since the report made by DICOM SR can refer to images, the integrated information of reports and images is possible.

  • PDF

Data Acquisition System Design and Implementation of Cargo System Using a Large Output X-ray (고출력 X-선을 이용한 대형화물 검색시스템의 Data Acquisition System 설계 및 구현)

  • Yoo, Sun-Won;Kim, In-Su;Kim, Bong-Su;Yi, Yun
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.223-226
    • /
    • 2002
  • Data Acquisition System of Cargo System using a large output X-ray in harbors is usually composed of Detector, Analog Board, Digital Board, Master Board, Backplane Board and Image Construction System. In this paper we have made an image of material in container-box with Data Acquisition System and studied mainly a configuration method and principle to each part of Data acquisition system.

  • PDF

Development of Radio Spectrum Monitor for HF Communication (단파 스펙트럼 수신 모니터링 시스템 개발)

  • Park, Sung Won;Kim, Young Yun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.9
    • /
    • pp.821-827
    • /
    • 2015
  • Electromagnetic waves which are emitted from the Sun due to solar flare explosion can cause failures in HF radio communications in the day-side area of the Earth, that is so-call as Radio Blackouts. The international scale representing the severity of the Radio Blackouts is determined by the solar X-ray flux which is measured by United States Geostationary Operational Environmental Satellite. However, the scale is not always applicable to HF communication users in the different area on the Earth, because the HF communication effects depend not only on the X-ray strength but also on the subsolar point location. To solve this problem, we developed a HF radio spectrum monitoring system utilizing a spectrum analyzer. This system conducts a real-time measure of the HF spectrum, and automatically calculates signal to noise ratios and the occurrences of the HF blackouts as comparing with the interference level which is described from the ITU recommendation.

Phase Transition Characteristics in $Ge_xSb_{100-x}$ Film for Optical Storage Media

  • Park Tae-jin;Kang Myung-jin;Choi Se-young
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.124-127
    • /
    • 2005
  • Rewritable optical memory devices such as an CD-RW and DVD+RW are data storage media, which take advantage of the different optical properties in the amorphous and crystalline states of phase change materials. The switching property, structural transformation, transformation kinetics and chemical bindings of $Ge_xSb_{100-x}$($6{\le}x{\le}$34) were studied to investigate the feasibility of applying $Ge_xSb_{100-x}$ alloys in optical memory. The $Ge_xSb_{100-x}$ thin film was deposited by RF magnetron co-sputtering system and phase change characteristics were investigated by X-ray diffraction (XRD), static tester, inductively coupled plasma atomic emission spectrometer (ICP-AES) and atomic force microscopy (AEM). Optimum fiim composition of $Ge_xSb_{100-x}$ was studied and its minimum time fur laser induced crystallization and optical contrast fur phase transition was performed. These results might be correlated with the binding energies between Ge and Sb, and indicate that $Ge_xSb_{100-x}$ have an potential far optical memory applications.

  • PDF

A Study on the Development of a MPACS (시범 MPAC 시스템 개발에 관한 연구)

  • 김근섭;임호근
    • Journal of Biomedical Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.215-222
    • /
    • 1991
  • In this paper, we present a result of our study on how to construct a pilot MPACS (medical hic lure archiving and communication System) based on X -Window system. The proposed MPACS Is composed of image acquisition units, image archiving and processing units, display units, and all units are Interfaced with a LAN The image management is done according to the TIFF (Tagged Image File Format) , and the dis- play system is built upon generally accepted software packages, namely the X -Window system. Also, lossless and lossy digital image compression methods were implemented and tested with X -ray and CT images.

  • PDF

A Comparative Study of Image Quality and Radiation Dose according to Variable Added Filter and Radiation Exposure in Diagnostic X-Ray Radiography (진단용 X-선 촬영시 부가 필터 및 노출의 변화에 따른 피폭선량 및 영상 화질 비교 연구)

  • Choi, Nam-Gil;Seong, Ho-Jin;Jeon, Joo-Seop;Kim, Youn-Hyun;Seong, Dong-Ook
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.25-34
    • /
    • 2012
  • To know which parameters were acceptable for achieving lowest radiation exposure to the patients and highest image quality at the diagnostic X-ray radiography, we measured the patient radiation dose and image quality in transmitted PACS (Picture Archiving and Communication System) at variable combinations of the added filters. As a result, the Dose Area Product (DAP: $mGy{\cdot}cm^2$) and Entrance Surface Doses (ESDs: $mGy$) was lowest at 1 mmAl + 0.2 mmCu and highest at 0 mmAl. The histogram of the image quality by transmitted PACS was not significantly different at variable combinations of exposure parameters on the MATLAB. In conclusion, this study can be helpful for expecting radiation dose-exposure and control exposure parameters for the diagnostic X-ray radiography.