• 제목/요약/키워드: X-plane

검색결과 1,057건 처리시간 0.03초

CCD-카메라를 이용한 홀 변위 자동측정시스템 개발 (Development of Automatic Hole Position Measurement System using the CCD-camera)

  • 김병규;최재영;강희준;노영식
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.127-130
    • /
    • 2004
  • For the quality control of the industrial products, an automatic hole measuring system has been developed. The measurement device allows X-Y movement due to contact forces between a hole and its own circular cone and the device is attached to an industrial robot. Its measurement accuracy is about 0.04mm. This movement of the plate is measured by two LVDT sensor system. But this system using the LVDT sensors is restricted by high cost and precision of measurement and correspondence of environment so particularly, a vision system with CCD-Camera is discussed in this paper for the above mentioned purpose. The device consists of two of two links jointed with hinge pins basically and, they guarantee free movement of the touch prove attached on the second link in the same plane. These links are returned to home position by the spring plungers automatically after each process for the next one. On the surface of the touch prove, it has a circular white mark for camera recognition. The system detect and notify the center coordinate of capture mark image through the image processing. Its measuring accuracy has been proved to be about $\pm$0.01mm through the repeated implementation over 200 times. This technique will shows the advantage of touch-indirect image capture idea using cone-shaped touch prove in various symmetrical shaped holes particulary, like tapped holes, chamfered holes, etc As a result, we attained our object in a view of the accuracy, economical efficiency, and functionality

  • PDF

Sol-gel 방법에 의한 $LaAlO_3$ 박막의 제조 (Preparation of $LaAlO_3$ thin Films by Sol-gel Method)

  • 김혜진;김병주;이희균;홍계원
    • Progress in Superconductivity
    • /
    • 제9권1호
    • /
    • pp.85-90
    • /
    • 2007
  • Lanthanum aluminate($LaAlO_3$) film has been prepared on single crystal and metal substrates by dip coating method. Lanthanum acetate and aluminum were prepared via ligand exchange starting from lanthanum nitrate hexahydrate and aluminum nitrate hexahydrate in acetate glacial acetic acid solution after being refluxed. Coating solution was obtained by diluting the gel with methanol and 2-methoxyethanol to adjust the total cation concentration to 0.67 M. Precursor coated film was prepared by dip-coating with a speed of 25 mm/min on various substrates such as $LaAlO_3$ (001), MgO(001), $SrTiO_3$(001) single crystal, LMO/MgO/Ni-alloy. Thin films have been obtained by heat treating the precursor film at various temperatures from $600^{\circ}C{\sim}900^{\circ}C$ and various heating rate from $0.83^{\circ}C/min{\sim}1.25^{\circ}C/min$ under $Ar/O_2$ mixture containing 1000ppm oxygen. The films have been characterized by scanning electronic microscopy (SEM) and X-ray diffraction (XRD). XRD analysis for the prepared film showed that $LaAlO_3$ thin films with a preferred orientation of (100) plane parallel to substrate surface were obtained at $800^{\circ}C(1.11\;^{\circ}C/min)$ on LMO/MgO/Ni-alloy substrate, but the intensity decreased with the increase of heat treatment temperature.

  • PDF

3차원 판구조물 해석을 위한 삼각형요소와 사각형 요소의 비교에 관한 연구 (A Study on the Comparison of Triangular and Quadrilateral Elements for the Analysis of 3 Dimensional Plate Structures)

  • 왕지석;김유해;이우수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제26권3호
    • /
    • pp.344-352
    • /
    • 2002
  • In the analysis of the 3 dimensional plate structures by the finite element method, the triangular elements are generally used for the global stiffness matrix of the analyzed system. But the triangular elements of the plates have some problems in the process of formulation and in the precision of analysis. The formulation of the finite element method to analyze 3 dimensional plate structures using quadrilateral elements is presented in this paper. The degree of freedom off nodal point is 6, that is, the displacements in the direction off-y-z is and the rotations about x-y-z axis and then the degree of freedom off element is 24. For the comparison of the analysis using triangular elements and quadrilateral elements, the rectangular plates subjected to the uniform load and a concentrated load on the centroid of the plate, for which the theoretical solutions have been obtained, are analyzed. The calculated deflections of the rectangular plates using the finite element method by the triangular elements and the quadrilateral elements are also compared with the deflections of the plates calculated by theoretical solutions. The defections of the rectangular plates calculated by the finite element method using the quadrilateral elements are closer to the theoretical solutions than the defections calculated by the finite element method using the triangular elements. The deflection of the centroid of plate, calculated by the finite element method, converges to that of theoretical solution as the number of elements is increased. This convergence is much more rapid for the case of using the quakrilateral elements than fir the case of using triangular elements.

방사선 치료 시 조사야 내에 위치할 수 있는 이물질이 체표선량에 미치는 영향 (Effect of skin dose by materials located in treatment field)

  • 홍채선;김경태;주상규;김종식;박영환
    • 대한방사선치료학회지
    • /
    • 제14권1호
    • /
    • pp.59-64
    • /
    • 2002
  • Purpose : In radiotherapy, various materials are used to located in treatment field unintentionally. It increases the dose delivered to the skin by interactions of the X-ray within the materials and occurs unwanted skin reaction.(due to the dose build-up effect) This aim of the this study is to measure the increase in skin dose when 13 materials are located in treatment field. Methods : Photon beam measurements were made using an plane-parallel chamber (Markus, PTW-Freiburg) in a polystyrene phantom. skin dose were measured using various overlaying 13 materials. a fixed geometry of a $10{\times}10cm$ field, a SSD=100cm and photon energy 4MV on Varian CLINAC 600C accelerator were used for all measurements. Results : There is an increase in skin dose for all materials($16.4{\sim}160.1\%$). As a percentage of maximum dose, the lowest skin dose were measured for the underwear with silk($43.2\%$) and the highest were measured for the 100m1 fluid-bag($96.6\%$) Conclusion : There is a significant increase in skin dose with 13 materials in the treatment field. a significant increase in skin dose can occur which could produce unwanted skin reaction. considerations for placement of 13 materials to be outside the treatment field whenever possible should be used to keep skin dose to a minimum level.

  • PDF

Gap arthroplasty with active mouth opening exercises using an interocclusal splint in temporomandibular joint ankylosis patients

  • Park, Min Woo;Eo, Mi Young;Seo, Bo Yeon;Nguyen, Truc Thi Hoang;Kim, Soung Min
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제41권
    • /
    • pp.18.1-18.10
    • /
    • 2019
  • Background: Temporomandibular joint (TMJ) ankylosis during early childhood may lead to disturbances in growth and facial asymmetry and to serious difficulties in eating as well as in breathing during sleep. The purpose of this study is to describe the effectiveness of an interocclusal splint (IOS) for active mouth opening exercises in the treatment of TMJ ankylosis. Methods: A total of nine patients with 13 instances of TMJ ankylosis from 2008 to 2010 were included in this study, of which five patients were male and four patients were female. Five patients demonstrated unilateral ankylosis, while five patients showed bilateral symptoms. Ankylosed mass resection with coronoidectomy, fibrotic scar release, and resection of stylohyoid ligament calcification was performed with gap arthroplasty without an interpositional graft, and all patients were assessed for maximum mouth opening (MMO) during a mean 6.6-year follow-up period. Results: All patients were subjected to postoperative mouth opening exercises from the day of the operation with the help of an IOS, which was based on an impression taken during surgery. All patients were sufficiently comfortable moving their mandible according to the IOS's guiding plane and impingement, and satisfactory results were achieved, in which MMO was improved by 35 mm more than 6 years after surgery. Conclusions: Complete and adequate resection of the ankylosed mass and postoperative active mouth opening exercises are essential in the treatment of TMJ ankylosis. Moreover, a more comfortable mouth opening guide and interdigitation can be achieved using an IOS, and newly organized fibrosis in the gap space between the newly made resected condylar head and temporal fossa can be suggested.

단시안 명암강도를 이용한 물체의 3차원 거리측정 (Obtaining 3-D Depth from a Monochrome Shaded Image)

  • Byung Il Kim
    • 전자공학회논문지B
    • /
    • 제29B권7호
    • /
    • pp.52-61
    • /
    • 1992
  • 본 논문은 단시안에 투영된 3차원 물체의 Image에서 측정된 명암강도의 차이를 이용하여 3차원 물체의 절대거리 z 및 형상을 유출하는 수치적인 방법을 연구, 단시안에 의해서도 Camera와 물체사이의 3차원 절대거리가 구해질 수 있음을 보여주고 있다. 기발표된 이론과는 다르게 본 논문에서는 점광원을 이용하여 투영된 명암강도와 3차원 물체의 절대거리 및 형상과의 관계를 물체가 Uniform Lambertian이라는 가정하에서 새로운 관계식으로 정립하였다. 정립된 Non-Linear 관계식은 Smoothness 조건아래 $'Calculus of Variation$'방법을 사용하여 수학적 Algorithm으로 정리되어 Programming 되었고 간단한 실험방법을 이용하여 실제 Data에 적용시켜 그 타당성을 조사하였다.당성을 조사하였다.

  • PDF

Korean /l/-flapping in an /i/-/i/ context

  • Son, Minjung
    • 말소리와 음성과학
    • /
    • 제7권1호
    • /
    • pp.151-163
    • /
    • 2015
  • In this study, we aim to describe kinematic characteristics of Korean /l/-flapping in two speech rates (fast vs. comfortable). Production data was collected from seven native speakers of Seoul Korean (four females and three males) using electromagnetic midsagittal articulometry (EMMA), which provided two dimensional data on the x-y plane. We examined kinematic properties of the vertical/horizontal tongue tip gesture, the vertical/horizontal (rear) tongue body gesture, and the jaw gesture in an /i/-/i/ context. Gestural landmarks of the vertical tongue tip gesture are directly measured. This serves as the actual anchoring time points to which relevant measures of other trajectories referred. The study focuses on velocity profiles, closing/opening spatiotemporal properties, constriction duration, and constriction minima were analyzed. The results are summarized as follows. First, gradiently distributed spatiotemporal values of the vertical tongue tip gesture were on a continuum. This shows more of a reduction in fast speech rate, but no single instance of categorical reduction (deletion). Second, Korean /l/-flapping predominantly exhibited a backward sliding tongue tip movement, in 83% of production, which is apparently distinguished from forward sliding movement in English. Lastly, there was an indication of vocalic reduction in fast rate, truncating spatial displacement of the jaw and the tongue body, although we did not observe positional variations with speech rate. The present study shows that Korean /l/-flapping is characterized by mixed articulatory properties with respect to flapping sounds of other languages such as English and Xiangxiang Chinese. Korean /l/ flapping demonstrates a language-universal property, such as the gradient nature of its flapping sounds that is compatible with other languages. On the other hand, Korean /l/-flapping also shows a language-particular property, particularly distinguished from English, in that a backward gliding movement occurs during the tongue tip closing movement. Although, there was no vocalic reduction in V2 observed in terms of jaw and tongue body height, spatial displacement of these articulators still suggests truncation in fast speech rate.

A study on the machining accuracy of dental digital method focusing on dental inlay

  • Bae, Eun-Jeong;Jeong, Il-Do;Kim, Woong-Chul;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권4호
    • /
    • pp.321-327
    • /
    • 2018
  • PURPOSE. The purpose of this study was to compare the cutting method and the lamination method to investigate whether the CAD data of the proposed inlay shape are machined correctly. MATERIALS AND METHODS. The Mesial-Occlusal shape of the inlay was modeled by changing the stereolithography (STL). Each group used SLS (metal powder) or SLA (photocurable resin) in the additive method, and wax or zirconia in the subtractive method (n=10 per group, total n=40). Three-dimensional (3D) analysis program (Geomagic Control X inspection software; 3D systems) was used for the alignment and analysis. The root mean square (RMS) in the 2D plane state was measured within $50{\mu}m$ radius of eight comparison measuring points (CMP). Differences were analyzed using one-way analysis of variance and post-hoc Tukey's test were used (${\alpha}=.05$). RESULTS. There was a significant difference in RMS only in SLA and SLS of 2D section (P<.05). In CMP mean, CMP 4 ($-5.3{\pm}46.7{\mu}m$) had a value closest to 0, while CMP 6 ($20.1{\pm}42.4{\mu}m$) and CMP 1 ($-89.2{\pm}61.4{\mu}m$) had the greatest positive value and the greatest negative value, respectively. CONCLUSION. Since the errors obtained from the study do not exceed the clinically acceptable values, the lamination method and the cutting method can be used clinically.

풍력 블레이드를 위한 CNT 코팅 유리섬유의 적용성에 대한 비교 연구 (A Comparative Study on the Applicability of CNT-coated Glass Fiber for Wind Blades)

  • 장홍규;김영철
    • Composites Research
    • /
    • 제29권6호
    • /
    • pp.336-341
    • /
    • 2016
  • 본 논문에서는 복합재 풍력 블레이드를 위한 CNT 코팅 유리섬유의 전자기적/기계적 적용성에 대한 연구를 수행하였다. MW급 이상의 대형 복합재 블레이드는 민수용/군수용 레이더와의 신호간섭 문제로 인한 발전단지 위치선정 제약과 무게 증가에 따른 발전효율 저해, 구조적 건전성 부족에 따른 수리비용 증가의 당면과제를 안고 있다. 이에 본 연구에서는 이러한 문제를 극복하기 위한 방안으로 CNT 코팅 유리섬유를 제안하였다. 먼저 제안된 CNT 코팅 공정을 통해 유리섬유 표면에 CNT를 강력히 코팅하고, Va-RTM을 통해 CNT 코팅/유리섬유 에폭시 복합재를 제작하여 전자기적/기계적 물성을 평가하였다. 또한 전자파 흡수체 설계/제작 및 시험/평가를 통해 X-band의 8.3~12.1 GHZ에서 90% 이상 전자파 흡수성능을 가짐을 검증하였다. 이와 더불어 기계적 물성 시험/평가를 통해서 인장, 압축, 면내전단 강도/강성의 모든 기계적 물성이 향상됨을 확인하였다.

잔류응력을 고려한 점용접이음재의 피로설계 (Fatigue Design of Spot Welded Lap Joint Considered Residual Stress)

  • 손일선;배동호;홍정균;이범노
    • 대한기계학회논문집A
    • /
    • 제24권3호
    • /
    • pp.743-751
    • /
    • 2000
  • Because welding residual stress is formidable result in electric resistance spot welding process, and it detrimentally affect to fatigue crack initiation and growth at nugget edge of spot welded la p joints, it should be considered in fatigue analysis. Thus, accurate prediction of residual stress is very important. In this study, nonlinear finite element analysis on welding residual stress generated in process of the spot welding was conducted, and their results were compared with experimental data measured by X-ray diffraction method. By using their results, the maximum principal stress considered welding residual stress at nugget edge of the spot welded lap joint subjected to tension-shear load was calculated by superposition method. And, the $\Delta$P- $N_f$ relations obtained through fatigue, tests on the IB-type spot welded lap joints was systematically rearranged with the maximum principal stress considered welding residual stress. From the results, it was found th2at fatigue strength of the IB-type spot welded lap joints could be systematically and more reasonably rearranged by the maximum principal stress($\sigma$1max-res considered welding residual stress at nugget edge of the spot welding point.