• Title/Summary/Keyword: X-Ray Tomography

Search Result 804, Processing Time 0.029 seconds

Permeability Prediction of Gas Diffusion Layers for PEMFC Using Three-Dimensional Convolutional Neural Networks and Morphological Features Extracted from X-ray Tomography Images (삼차원 합성곱 신경망과 X선 단층 영상에서 추출한 형태학적 특징을 이용한 PEMFC용 가스확산층의 투과도 예측)

  • Hangil You;Gun Jin Yun
    • Composites Research
    • /
    • v.37 no.1
    • /
    • pp.40-45
    • /
    • 2024
  • In this research, we introduce a novel approach that employs a 3D convolutional neural network (CNN) model to predict the permeability of Gas Diffusion Layers (GDLs). For training the model, we create an artificial dataset of GDL representative volume elements (RVEs) by extracting morphological characteristics from actual GDL images obtained through X-ray tomography. These morphological attributes involve statistical distributions of porosity, fiber orientation, and diameter. Subsequently, a permeability analysis using the Lattice Boltzmann Method (LBM) is conducted on a collection of 10,800 RVEs. The 3D CNN model, trained on this artificial dataset, well predicts the permeability of actual GDLs.

The Accuracy Rate in Comprehension of Aspects of Nasal Bone Fracture Based on Simple X-ray and 2D CT Compared with 3D Image (비골 골절 형태의 입체적 분석에 있어 3D 영상과 비교한 단순방사선영상 및 2D CT 영상의 정확도)

  • Han, Dong Gil;Kim, Tae Seob;Park, David Dae Hwan;Shim, Jeong Su;Lee, Yong Jig
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.2
    • /
    • pp.111-118
    • /
    • 2012
  • Purpose: The nasal bone fracture is known as the most common facial fracture, with the postoperative results and the patient's satisfaction known to be lower than other facial fractures. The patient's satisfaction is firstly related to the accurate comprehension of the spatial relationship in the fractured nasal bone and secondly to the accurate reduction based on accurate comprehension. The aim of this study is to evaluate the objective usefulness of the three-dimensional (3D) imaging. Methods: The survey was conducted on 10 randomly selected cases of nasal bone fractures among the 46 cases with 3D computed tomography (CT) during the past one year. It was requested upon 4 plastic residents and 4 plastic surgeons to draw 3D aspect of fractured nasal bone directly on the printed photos of cadaver nasal bone, based on simple X-ray and two-dimensional (2D) CT. They were compared with the real fractured nasal bone aspects based on the 3D image and marked the difference in the 10-point scale of 0 to 10. Results: The average score of the 4 residents was 1.62 and that of the 4 surgeons was 4.47 out of 10 by simple X-ray. The average score of the 4 residents was 5.67 and that of the 4 surgeons was 7.25 out of 10 by 2D CT. Conclusion: It was surmised that the precise analysis and accurate comprehension of the spatial relationship of the fractured nasal bone using the 3D image, as based on the 2D CT images, can produce more favorable satisfaction levels in the patients.

Practical Approach to the Diagnosis of Pediatric Nasal Bone Fractures (소아 환자의 코뼈 골절 진단을 위한 실제적 접근)

  • Lee, Yulkok;Oh, Sungchan;Cho, Sukjin;Kim, Hyejin;Kang, Taekyung;Choi, Seungwoon;Yoo, Hanbin;Ryu, Seokyong
    • Journal of Trauma and Injury
    • /
    • v.27 no.4
    • /
    • pp.95-100
    • /
    • 2014
  • Purpose: Nasal bone fractures are the most common childhood facial bone fractures, with an incidence of about 39%. While taking a nasal bone x-ray is a common modality used in the emergency department, reports have expressed concerns with its low sensitivity and low specificity. Our study was aimed at comparing accuracy of physical and x-ray examination with that of facial bone computed tomography (CT). Methods: Electronic medical records (EMR) were retrospectively reviewed for patients under the age of 15 who visited our emergency department from January 2010 to December 2011with a chief complaint of nasal pain due to trauma and who had also undergone a nasal bone x-ray and facial bone CT. Patients who had not taken facial bone CT, who had been transferred, and who did not have EMR were excluded. We divided the patients into 2 groups, those who had nasal bone fractures and those without a fracture on their facial bone CT. We analyzed other parameters such as age, sex, and type of fracture to find statistical differences between the two groups. Results: A total of 209 patients were included. The patients with nasal bone fractures on their facial bone CT were older, and their traumas were more violent. Ten patients who had apparent nasal bone fractures on their facial bone CT had no definite signs of a fracture on their plain x-ray. Conclusion: Though facial bone CT is an effective modality in detecting nasal bone fractures, in evaluating younger patients suspected of having nasal bone fractures, prudent use of facial bone CT is needed to reduce unnecessary exposure to radiation.

Mechanical evaluation of SiC-graphite interface of seed crystal module for growing SiC single crystals (탄화규소 단결정 성장을 위한 종자결정모듈의 탄화규소-흑연 간 접합계면의 기계적 특성 평가)

  • Kang, June-Hyuk;Kim, Yong-Hyeon;Shin, Yun-Ji;Bae, Si-Young;Jang, Yeon-Suk;Lee, Won-Jae;Jeong, Seong-Min
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.32 no.5
    • /
    • pp.212-217
    • /
    • 2022
  • Large thermal stress due to the difference between silicon carbide and graphite's coefficients of thermal expansion could be formed during crystal growing process of silicon carbide (SiC) at high temperature. The large thermal stress could separate the SiC seed crystals from graphite components, which bring about the drop of the seed crystal during crystal growth. However, the bonding properties of SiC seed crystal module has hardly reported so far. In this study, SiC and graphite were bonded using 3 types of bonding agents and a three-point bending tests using a mixed-mode flexure test were conducted for the bonded samples to evaluate the bonding characteristics between SiC and graphite. Raman spectroscopy, X-ray Photoelectron Spectroscopy, and X-ray Computed Tomography were used to analyze the bonding characteristics and the microstructures of the SiC-graphite interfaces bonded with the bonding agents. As results, an excellent bonding agent was chosen to fabricate SiC seed crystal module with 50 mm in diameter. An SiC single crystal with 50 mm in diameter was successfully grown without falling out during top seeded solution growth of SiC at high temperature.

A comparison of canal centering abilities of four root canal instrument systems using X-ray micro-computed tomography (방사선 미세컴퓨터단층촬영을 이용한 네 종류 file systems의 중심유지능에 관한 비교)

  • Ko, Hye-Suk;You, Heyon-Mee;Park, Dong-Sung
    • Restorative Dentistry and Endodontics
    • /
    • v.32 no.1
    • /
    • pp.61-68
    • /
    • 2007
  • The purpose of this study was to compare the centering abilities of four root canal instrument systems and the amounts of dentin removed after root canal shaping using them. The mesial canals of twenty extracted mandibular first molars having $10-20^{\circ}$ curvature were scanned using X-ray micro-computed tomography (XMCT)-scanner before root canals were instrumented. They were divided into four groups (n = 10 per group). In Group 1, root canals were instrumented by the step-back technique with stainless steel K-Flexofile after coronal flaring. The remainders were instrumented by the crown-down technique with Profile (Group 2), ProTaper (Group 3) or K3 system (Group 4). All canals were prepared up to size 25 at the end-point of preparation and scanned again. Scanned images were processed to reconstruct three-dimensional images using three-dimensional image software and the changes of total canal volume were measured. Pre-and post-operative cross-sectional images of 1, 3, 5, and 7 mm from the apical foramen were com pared. For each level, centering ratio were calculated using Adobe Photoshop 6.0 and image software program. ProTaper and K3 systems have a tendency to remove more dentin than the other file systems. In all groups, the lowest value of centering ratio at 3 mm level was observed. And except at 3 mm level, ProTaper system made canals less centered than the other systems (p < 0.05).

Clinical Features and Outcomes of Pelvic Insufficiency Fractures (골반 부전 골절의 임상 양상과 치료 결과)

  • Seo, Yong Min;Kim, Young Chang;Kim, Ji Wan
    • Journal of the Korean Fracture Society
    • /
    • v.30 no.4
    • /
    • pp.186-191
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the radiological and epidemiological characteristics, as well as the clinical course of pelvic insufficiency fractures in the elderly population. Materials and Methods: At a Haeundae Paik Hospital, we retrospectively reviewed patients with pelvic insufficiency fractures between March 2010 and May 2017. The demographic data of patients were analyzed, and bone mineral density and bone turnover markers were evaluated to estimate the metabolic status of the bone. The radiological characteristics were evaluated by comparing the simple x-ray images with the computed tomography images, and the types of fractures were classified via computed tomography images. For clinical course evaluation, we investigated comorbid complications, and compared the walking ability scale before and 6 months after the fracture. Results: A total of 42 patients were included, with an average age of 76.5 years. All were female except one case. In 5 cases where the initial medical examination was from another institution, the fracture was not found in 3 cases. All cases received conservative treatment. After the diagnosis of pelvic bone fracture using a simple x-ray imaging, additional fractures were found in 81.0% of the study population using a computed tomography. Initiation of gait occurred at an average of 2.8 weeks, and every case except 1 (97.6%) fully recovered their gait ability. Conclusion: We concluded that there was a limitation with diagnosing pelvic insufficiency fracture using only a simple x-ray imaging technique. In general, cases in this study showed conservative treatment yielded favorable clinical outcome with relatively less critical complications.

Features and Trends of IEC Particular Standards for Medical Equipment Related to Diagnostic X-ray Based on IEC 60601-1:2005 Ed. 3.0 (IEC 60601-1: 3판이 적용된 진단용 X선장치 관련 개별규격의 동향 및 특징)

  • Kim, Hyun-Ji;Kim, Jung-Min;Choi, In-Seok;Yoon, Yong-Su;Seo, Deok-Nam;Kim, Jung-Su;Kim, Dae-Young;Park, Sung-Yong
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.1-10
    • /
    • 2013
  • IEC publications have applied in many countries all over the world such as Europe or Japan and these also have been published as in dustrial standards (KS) and notifications of Korea Food and Drug Administration (KFDA) in Korea. As the general standard of IEC 60601 series for medical electric (ME) equipment was revised as $3^{rd}$ edition in 2005, additional and particular standards have been revised or established newly. Under these circumstances, it is importance for manufacturing and assembling companies or authorized testing companies to understand the trend for revisions of IEC publications. Therefore in this study, the latest version of 3 IEC standards related to medical X-ray equipment : IEC 60601-2-44 for X-ray equipment for computed tomography (CT), IEC 60601-2-45 for mammographic X-ray equipment and IEC 60601-2-54 for X-ray equipment for radiography or radioscopy were covered and analyzed for trends and features accompanied by revision based on IEC 60601-1 $3^{rd}$ Ed. As KFDA notifications in force have referred to the particular standards based on 2nd edition of IEC 60601-1, those revised version of 3 particular standards were compared to KFDA notifications in force. The features of the latest standards applying IEC 60601-1 $3^{rd}$ Ed were shown as following: 1) Requirements for mechanical hazards, especially (motorized) moving parts were emphasized. 2) Indication and recording of patient dose were required. 3) Risk management process was introduced and enabled to monitor potential risks systematically. 4) DR system (digital radiography system) as well as analogue system (film-screen system) was included in the scope. Presently, KFDA will revise the notifications applying the particular standards based on IEC 60601-1 $3^{rd}$ Ed in a few years. Therefore the features of particular standards applying IEC 60601-1 $3^{rd}$ Ed was expected to help manufacturers, assemblers or testing companies of medical electric equipment understand IEC publications or KFDA notifications slated to be published.

Condylar position on the lateral individualized corrected tomography in internal derangement of temporomandibular joint (측두하악관절 내장증시 측방 개별화 보정단층방사선사진에서의 하악과두의 위치)

  • Kim Keun-Min;Hwang Eui-Hwan;Lee Sang-Rae
    • Imaging Science in Dentistry
    • /
    • v.32 no.2
    • /
    • pp.67-73
    • /
    • 2002
  • Purpose: To examine the possible relationship between condylar position and disk displacement in the temporomandibular joint. Materials and Methods: 79 temporomandibular joints in 40 patients having temporomandibular disorders were classified into three categories: no disk displacement (NDD) , disk displacement with reduction (DDWR), and disk displacement without reduction (DDWOR). Disk positions were assessed from clinical and MRI findings. The relationship between the three categories and condylar positions was evaluated using lateral individualized corrected tomography. Results: Clinical findings regarding the relationship between condyle and disk positions having anterior, centric, and posterior positions were 27%, 27%, and 46%, respectively, in NDD, 43%, 17%, and 40%, respectively, in DDWR, and 44%, 22%, and 34%, respectively, in DDWOR. There were no significant differences in condylar positions between each of the groups (P>0.05). In the relationship between condyle and disk positions with MRI findings, anterior, centric, and posterior positions were 38%, 38%, and 24%, respectively, in NDD, 29%, 21%, and 50%, respectively, in DDWR, and 44%, 9%, and 47% respectively, in DDWOR. There were significant differences in the condylar positions when MRI was utilized (P<0.05) Conclusion: There was a significant correlation between the condyle and disk positions with MRI findings on lateral individualized corrected tomography.

  • PDF

Earth and Environmental Sciences with Synchrotron Radiation (방사광의 원리와 지구환경과학에의 응용)

  • 김영호
    • The Journal of the Petrological Society of Korea
    • /
    • v.10 no.3
    • /
    • pp.212-221
    • /
    • 2001
  • This paper introduces the characteristics and generation of the synchrotron radiation (SR). SR has the very high spectral brilliance, broad spectral range, X-ray wavelength tunability, high degree of polarization and collimation, and pulsed time structure. Also describes the technologies to apply in the fields of geology and environmental sciences. These include X-ray tomography, XRF, EXAFS, XANES, DAC, IVP experiments. Further, nuclear power generation and nuclear waste disposal methods are mentioned relating to energy. Using these, analyses of the chemistry, crystal structure and chemical combining states of minerals and rocks can be carried out. Applications in the fields of the economic geology, paleontology and environmental sciences are open too. Informations of the Earth interior materials' behavior under high pressure-temperature can be acquired.

  • PDF

Radiographic Analysis of Instrumented Posterolateral Fusion Mass Using Mixture of Local Autologous Bone and b-TCP (PolyBone$^{(R)}$) in a Lumbar Spinal Fusion Surgery

  • Park, Jin-Hoon;Choi, Chung-Gon;Jeon, Sang-Ryong;Rhim, Seung-Chul;Kim, Chang-Jin;Roh, Sung-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.49 no.5
    • /
    • pp.267-272
    • /
    • 2011
  • Objective : Although iliac crest autograft is the gold standard for lumbar fusion, the morbidity of donor site leads us to find an alternatives to replace autologous bone graft. Ceramic-based synthetic bone grafts such as hydroxyapatite (HA) and b-tricalcium phosphate (b-TCP) provide scaffolds similar to those of autologous bone, are plentiful and inexpensive, and are not associated with donor morbidity. The present report describes the use of Polybone$^{(R)}$ (Kyungwon Medical, Korea), a beta-tricalcium phosphate, for lumbar posterolateral fusion and assesses clinical and radiological efficacy as a graft material. Methods : This study retrospectively analyzed data from 32 patients (11 men, 21 women) who underwent posterolateral fusion (PLF) using PolyBone$^{(R)}$ from January to August, 2008. Back and leg pain were assessed using a Numeric Rating Scale (NRS), and clinical outcome was assessed using the Oswestry Disability Index (ODI). Serial radiological X-ray follow up were done at 1, 3, 6 12 month. A computed tomography (CT) scan was done in 12 month. Radiological fusion was assessed using simple anterior-posterior (AP) X-rays and computed tomography (CT). The changes of radiodensity of fusion mass showed on the X-ray image were analyzed into 4 stages to assess PLF status. Results : The mean NRS scores for leg pain and back pain decreased over 12 months postoperatively, from 8.0 to 1.0 and from 6.7 to 1.7, respectively. The mean ODI score also decreased from 60.5 to 17.7. X-rays and CT showed that 25 cases had stage IV fusion bridges at 12 months postoperatively (83.3% success). The radiodensity of fusion mass on X-ray AP image significantly changed at 1 and 6 months. Conclusion: The present results indicate that the use of a mixture of local autologous bone and PolyBone$^{(R)}$ results in fusion rates comparable to those using autologous bone and has the advantage of reduced morbidity. In addition, the graft radiodensity ratio significantly changed at postoperative 1 and 6 months, possibly reflecting the inflammatory response and stabilization.