• 제목/요약/키워드: X-Ray Computed Tomography

검색결과 701건 처리시간 0.023초

Cone beam CT와 일반 CT의 흡수선량 및 유효선량 비교평가 (Comparison of cone beam CT and conventional CT in absorbed and effective dose)

  • 김상연;한진우;박인우
    • Imaging Science in Dentistry
    • /
    • 제38권1호
    • /
    • pp.7-15
    • /
    • 2008
  • Purpose: This study provides comparative measurements of absorbed and effective doses for newly developed cone beam computed tomography (CT) in comparison with these doses for conventional CT. Materials and Methods: Thermoluminescent dosimeter rods (TLD rod: GR-200, Thermo Fisher Scientific Inc., Waltham, MA, USA) were placed at 25 sites throughout the layers of Male ART Head and Neck Phantom (Radiology Support Devices Inc., Long Beach, USA) for dosimetry. Implagraphy, DCT Pro (Vatech Co., Hwasung, Korea) units, SCT-6800TXL (Shimadzu Corp., Kyoto, Japan), and Crane x 3+(Soredex Orion Corp., Helsinki, Finland) were used for radiation exposures. Absorption doses were measured with Harshaw 3500TLD reader (Thermo Fisher Scientific Inc., Waltham, MA, USA). Radiation weighted doses and effective doses were measured and calculated by 2005 ICRP tissue weighting factors. Results: Absorbed doses in Rt. submandibular gland were 110.57 mGy for SCT 6800TXL (Implant), 24.56 mGy for SCT 6800TXL (3D), 22.39 mGy for Implagraphy 3, 7.19 mGy for DCT Pro, 5.96 mGy for Implagraphy 1, 0.70 mGy for Cranex 3+. Effective doses $(E_{2005draft)$ were 2.551 mSv for SCT 6800TXL (Implant), 1.272 mSv for SCT 6800TXL (3D), 0.598 mSv for Implagraphy 3, 0.428 mSv for DCT Pro and 0.146 mSv for Implagraphy 1. These are 108.6, 54.1, 25.5, 18.2 and 6.2 times greater than panoramic examination (Cranex 3+) doses (0.023mSv). Conclusion: Cone beam CT machines recently developed in Korea, showed lower effective doses than conventional CT. Cone beam CT provides a lower dose and cost alternative to conventional CT, promising to revolutionize the practice of oral and maxillofacial radiology.

  • PDF

폐아세포종 -수술치험 1례- (Pulmonary Blastoma -A Case Report-)

  • 금동윤
    • Journal of Chest Surgery
    • /
    • 제27권10호
    • /
    • pp.868-873
    • /
    • 1994
  • We experienced a very rare case of pulmonary blastoma in a 29 year old female. She complained of left chest pain and dyspnea for 1 month. The characteristic feature of this tumor is it`s biphasic pattern consisting of a spindle cell stroma containing glandular structures. A serial check of simple chest X-ray and computed tomography revealed a growing huge lung mass occupying whole left thorax. We successfully removed the upper lobe of left lung with a huge tumor mass. Pathologic study revealed this tumor as pulmonary blastoma. We report a case with review of literature.

  • PDF

Comparison of micro-computerized tomography and cone-beam computerized tomography in the detection of accessory canals in primary molars

  • Acar, Buket;Kamburoglu, Kivanc;Tatar, Ilkan;Arikan, Volkan;Celik, Hakan Hamdi;Yuksel, Selcen;Ozen, Tuncer
    • Imaging Science in Dentistry
    • /
    • 제45권4호
    • /
    • pp.205-211
    • /
    • 2015
  • Purpose: This study was performed to compare the accuracy of micro-computed tomography (CT) and cone-beam computed tomography (CBCT) in detecting accessory canals in primary molars. Materials and Methods: Forty-one extracted human primary first and second molars were embedded in wax blocks and scanned using micro-CT and CBCT. After the images were taken, the samples were processed using a clearing technique and examined under a stereomicroscope in order to establish the gold standard for this study. The specimens were classified into three groups: maxillary molars, mandibular molars with three canals, and mandibular molars with four canals. Differences between the gold standard and the observations made using the imaging methods were calculated using Spearman's rho correlation coefficient test. Results: The presence of accessory canals in micro-CT images of maxillary and mandibular root canals showed a statistically significant correlation with the stereomicroscopic images used as a gold standard. No statistically significant correlation was found between the CBCT findings and the stereomicroscopic images. Conclusion: Although micro-CT is not suitable for clinical use, it provides more detailed information about minor anatomical structures. However, CBCT is convenient for clinical use but may not be capable of adequately analyzing the internal anatomy of primary teeth.

봉독약침을 시행한 우측상악동의 악성 흑색종 환자에 대한 증례보고 (A Case Report on the Patient of Malignant Melanoma at Right Maxilla with the Treatment of Bee Venom Phamacopuncture)

  • 방선휘;유화승
    • 대한약침학회지
    • /
    • 제10권2호통권23호
    • /
    • pp.99-105
    • /
    • 2007
  • Objectives : It is the aim of this study to derive lurker studies evaluating the effectiveness of bee-venom phamacopuncture on malignant melanoma patients. We present a patient of malignant melanoma at right maxilla who survives over one year with stable disease (SD) by the treatment of Bee Venom Phamacopuncture (BVP). Methods : We followed the treatment and examination. We prescribed to the patient what to be taken 1.5cc BVP once a day. Picture series, Head series were followed-up and Neck computed tomography (CT) and positron emission tomography computed tomography (PET CT) were performed to evaluate the therapeutic efficacy. Results : The patient survives over one year and continued stable disease over 6 months. Picture series, Head series X-ray, neck CT and PET CT were shown no interval change. Conclusion : This case may give us the possibility that BVP offers potential benefits for patients with malignant melanoma.

Requirements for Future Digital Radiology System

  • Kim, Y.M.;Park, H.W.;Haynor, D.R.
    • 한국의학물리학회지:의학물리
    • /
    • 제2권1호
    • /
    • pp.3-16
    • /
    • 1991
  • Abstract. An area of particularly rapid technological growth in the last 15 years has been medical imaging (conventional X-ray, ultrasound, X-ray computed tomography (CT), magnetic resonance imaging (MRI). As the number and complexity of imaging studies rises, it becomes ever more important to distribute these images and the associated diagnoses in a timely and cost-effective fashion. The purpose of this paper is to describe the requirements for a future digital radiology system which will efficiently handle the large volume of images that generated, add new functionality to improve productivity of physicians, technologists, and other health care providers, and provide enough flexibility to allow the system to grow as medical image technology grows.

  • PDF

비등방성 2차원 확산 기반 필터를 이용한 전산화단층영상 품질 개선 (Image Quality Improvement in Computed Tomography by Using Anisotropic 2-Dimensional Diffusion Based Filter)

  • 성열훈
    • 한국방사선학회논문지
    • /
    • 제10권1호
    • /
    • pp.45-51
    • /
    • 2016
  • 본 연구에서는 비등방성 2차원 확산 기반 필터를 이용하여 전산화단층영상(computed tomography, CT)의 노이즈 제거와 공간분해능을 향상하고자 하였다. 실험은 4-채널 다중검출기 전산화단층영상기기(4-channel multi-detector computed tomography, MDCT)를 이용하였으며, CT 영상품질 평가를 위해 미국 의학물리학자협의회(american association of physicists in medicine, AAPM) CT 성능 평가용 팬톰을 사용하였다. X-선 조사 조건은 120 kVp, 100 mAs로 고정한 후 ultra-high resolution으로 10 mm 축 방향 스캔 하였다. 본 연구에서 제안한 비등방성 2차원 확산 기반 필터는 원 영상에 각 픽셀에 가중치 1.2를 곱하고 0.4% 히스토그램 스트레칭을 통해 영상의 대조도를 증가시킨 후 비등방성 2차원 확산 필터를 적용하였다. 그 결과, 공간분해능은 원 영상에서 0.75 mm까지 구분되었지만 제안한 비등방성 2차원 확산 기반 필터 영상에서는 0.40 mm까지 구분되었다. 원 영상의 노이즈는 46.0, 제안한 비등방성 2차원 확산 기반 필터 영상의 노이즈는 33.5로 27.2%가 감소하였다. 우리가 제안한 비등방성 2차원 확산 기반 필터는 CT의 노이즈 제거와 공간분해능을 향상시킬 수 있었다.

X-ray CT를 이용한 베레아 사암의 공극크기분포 산정 (Evaluation of Pore Size Distribution of Berea Sandstone using X-ray Computed Tomography)

  • 김광염;김경민
    • 지질공학
    • /
    • 제24권3호
    • /
    • pp.353-362
    • /
    • 2014
  • 다공질 암석의 공극구조는 그 암석의 수리-역학적 거동에 매우 큰 영향을 미친다. 다공질 암석의 공극구조 특성을 표현하는 대표적인 방법은 공극률, 공극크기분포, 방향성 등이 있다. 암석의 유효공극률은 실험적으로 비교적 쉽게 구할 수 있지만, 공극의 크기분포 특성을 파악하는 것은 매우 어려운 실정이다. 본 연구에서는 X-ray CT를 이용하여 대표적 다공질 암석인 베레아 사암의 공극구조 중 공극크기분포를 이미지 기반으로 평가하였다. 공극크기분포 평가를 위해 본 연구에서는 이미지 필터링, 이진화, 골격화 등의 이미지 기반 처리 작업을 수행하였으며, 국부 두께평가 및 star chord를 이용하여 베레아 사암의 공극크기분포를 구하였다. 본 연구에서 제시된 X-ray CT 기반의 공극크기분포 평가방법을 이용하여 향후 다공질 재료의 공극구조 평가에 새롭고 효율적인 방안을 제시하고자 하였다.

동적 시준을 이용한 CT 촬영과 볼록한 관심영역의 영상재구성 (Dynamically Collimated CT Scan and Image Reconstruction of Convex Region-of-Interest)

  • 진승오;권오경
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권5호
    • /
    • pp.151-159
    • /
    • 2014
  • Computed tomography (CT) is one of the most widely used medical imaging modality. However, substantial x-ray dose exposed to the human subject during the CT scan is a great concern. Region-of-interest (ROI) CT is considered to be a possible solution for its potential to reduce the x-ray dose to the human subject. In most of ROI-CT scans, the ROI is set to a circular shape whose diameter is often considerably smaller than the full field-of-view (FOV). However, an arbitrarily shaped ROI is very desirable to reduce the x-ray dose more than the circularly shaped ROI can do. We propose a new method to make a non-circular convex-shaped ROI along with the image reconstruction method. To make a ROI with an arbitrary convex shape, dynamic collimations are necessary to minimize the x-ray dose at each angle of view. In addition to the dynamic collimation, we get the ROI projection data with slightly lower sampling rate in the view direction to further reduce the x-ray dose. We reconstruct images from the ROI projection data in the compressed sensing (CS) framework assisted by the exterior projection data acquired from the pilot scan to set the ROI. To validate the proposed method, we used the experimental micro-CT projection data after truncating them to simulate the dynamic collimation. The reconstructed ROI images showed little errors as compared to the images reconstructed from the full-FOV scan data as well as little artifacts inside the ROI. We expect the proposed method can significantly reduce the x-ray dose in CT scans if the dynamic collimation is realized in real CT machines.

원위치 X-ray CT 촬영이 가능한 암석의 수리-역학 실험용 삼축셀 개발 (Development of Triaxial Cells Operable with In Situ X-ray CT for Hydro-Mechanical Laboratory Testing of Rocks)

  • 장리;염선;신휴성
    • 한국지반공학회논문집
    • /
    • 제36권9호
    • /
    • pp.45-55
    • /
    • 2020
  • X-ray CT는 암석시편의 공극 및 균열과 같은 내부 미세구조와 손상들의 정량적 분석에 활용되어 왔다. 원위치 CT는 외력 등 다양한 외적 요인에 영향을 받고 있는 암석 시편의 내외부 변화 과정을 관찰할 수 있게 해준다. 이의 확인을 위해, 암반/지반재료 특성분석에 활용한 원위치 X-ray CT 기술에 관한 최신 연구동향을 파악하였으며, 원위치 CT이미징이 가능한 암석의 수리-역학적 실험용 삼축셀을 개발하였다. 직경 25~50 mm 화강암 및 사암 코아시편의 원위치 CT이미징이 성공적으로 진행되었으며, 34~105 ㎛ 범위의 픽셀피치의 해상도를 취득할 수 있었다. 본 사전검토 촬영 실험을 통해 마이크로미터 스케일에서 암석의 내부구조 변화의 원위치 CT관찰이 가능한 것을 파악하였다. 요오드화 칼륨 용액은 CT이미지의 대비를 증가시키고 암석의 수리-역학 실험에서 주입유체로 사용할 수 있다.

3DentAI: 파노라마 X-ray로부터 3차원 구강구조 복원을 위한 U-Nets (3DentAI: U-Nets for 3D Oral Structure Reconstruction from Panoramic X-rays)

  • ;문성용;유원상
    • 정보처리학회 논문지
    • /
    • 제13권7호
    • /
    • pp.326-334
    • /
    • 2024
  • 파노라마 X-ray (PX) 및 Cone Beam Computed Tomography (CBCT)와 같은 구강 영상 기술은 영상 촬영 시 환자의 편의성과 전체 치아 정보를 시각화할 수 있는 능력으로 인해 치과 진료소에서 가장 선호되는 영상 기법이다. PX는 일상적인 임상 치료에 선호되고, CBCT는 복잡한 수술 및 임플란트 치료에 선호된다. 그러나 PX는 3차원 공간정보가 부족하다는 한계가 있는 반면 CBCT는 환자에게 높은 방사선 노출을 초래한다. PX가 이미 사용 가능한 경우 PX로부터 3D강 구강구조를 복원함으로써 추가 비용을 줄이고 방사선량을 피할 수 있다. 본 논문에서는 PX 이미지로부터 구강구조의 3차원 복원을 위한 U-Net 기반 딥러닝 프레임워크인 3DentAI를 제안한다. 제안된 프레임워크는 PX 이미지에서 깊이를 추정하기 위한 Attention U-Net 기반 재구성 모듈, 사전 정의된 초점 골 및 광선 데이터를 사용하여 예측된 편평 볼륨을 턱 모양에 정렬하기 위한 재정렬 모듈과, 구강의 원활한 표현을 얻기 위해 누락된 정보를 보간하는 3D U-Net 기반 개선 모듈의 세 가지 모듈로 구성된다. 네트워크를 훈련하기 위해, 쌍을 이루는 PX 및 CBCT 데이터셋 대신에 광선 추적 및 렌더링을 통해 CBCT로 부터 합성한 PX 데이터를 사용하였다. 600명의 환자로 구성된 다양한 데이터셋으로 모델을 훈련한 결과, 낮은 계산 복잡도에도 GAN 기반 모델에 비해 우수한 성능을 보였다.