• Title/Summary/Keyword: X-Band Frequency

Search Result 365, Processing Time 0.023 seconds

Development and Performance Compensation of the Extremely Stable Transceiver System for High Resolution Wideband Active Phased Array Synthetic Aperture Radar (고해상도 능동 위상 배열 영상 레이더를 위한 고안정 송수신 시스템 개발 및 성능 보정 연구)

  • Sung, Jin-Bong;Kim, Se-Young;Lee, Jong-Hwan;Jeon, Byeong-Tae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.6
    • /
    • pp.573-582
    • /
    • 2010
  • In this paper, X-band transceiver for high resolution wideband SAR systems is designed and fabricated. Also as a technique for enhancing the performance, error compensation algorithm is presented. The transceiver for SAR system is composed of transmitter, receiver, switch matrix and frequency generator. The receiver especially has 2 channel mono-pulse structure for ground moving target indication. The transceiver is able to provide the deramping signal for high resolution mode and select the receive bandwidth for receiving according to the operation mode. The transceiver had over 300 MHz bandwidth in X-band and 13.3 dBm output power which is appropriate to drive the T/R module. The receiver gain and noise figure was 39 dB and 3.96 dB respectively. The receive dynamic range was 30 dB and amplitude imbalance and phase imbalance of I/Q channel was ${\pm}$0.38 dBm and ${\pm}$3.47 degree respectively. The transceiver meets the required electrical performances through the individual tests. This paper shows the pulse error term depending on SAR performance was analyzed and range IRF was enhanced by applying the compensation technique.

Fabrication and characterization of the 0.25 ${\mu}m$ T-shaped gate P-HEMT and its application for MMIC low noise amplifier (0.25 ${\mu}m$ T형 게이트 P-HEMT 제작 및 특성 평가와 MMIC 저잡음 증폭기에 응용)

  • Kim, Byung-Gyu;Kim, Young-Jin;Jeong, Yoon-Ha
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.1
    • /
    • pp.38-46
    • /
    • 1999
  • o.25${\mu}m$ T-shaped gate P-HEMT is fabricated and used for design of X0band three stage monolithic microwave integrated circuit(MMIC) low noise amplifier(LNA). The fabricated P-HEMT exhibits an extrinsis transconductance of 400mS/mm and a drain current of 400mA/mm. The RF and noise characteristics show that the current gain cut off frequency is 65GHz and minimum noise figure(NFmin) of 0.7dB with an associated gain of 14.8dB at 9GHz. In the design of the three stage LNA, we have used the inductive series feedback circuit topology with the short stub. The effects of series feedback to the noise figure, the gain, and the stability have been investigated to find the optimal short stub length. The designed three staage LNA showed a gain of above 33dB, a noise figure of under 1.2dB, and ainput/output return loss of under 15dB and 14dB, respectively. The results show that the fabricated P-HEMT is very suitable for a X-band LNA with high gain.

  • PDF

Design of X-band 40 W Pulse-Driven GaN HEMT Power Amplifier Using Load-Pull Measurement with Pre-matched Fixture (사전-정합 로드-풀 측정을 통한 X-대역 40 W급 펄스 구동 GaN HEMT 전력증폭기 설계)

  • Jeong, Hae-Chang;Oh, Hyun-Seok;Yeom, Kyung-Whan;Jin, Hyeong-Seok;Park, Jong-Sul;Jang, Ho-Ki;Kim, Bo-Kyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.11
    • /
    • pp.1034-1046
    • /
    • 2011
  • In this paper, a design and fabrication of 40 W power amplifier for the X-band using load-pull measurement of GaN HEMT chip are presented. The adopted active device for power amplifier is GaN HEMT chip of TriQuint company, which is recently released. Pre-matched fixtures are designed in test jig, because the impedance range of load-pull tuner is limited at measuring frequency. Essentially required 2-port S-parameters of the fixtures for extraction optimal input and output impedances is obtained by the presented newly method. The method is verified in comparison of the extracted optimal impedances with data sheet. The impedance matching circuit for power amplifier is designed based on EM co-simulation using the optimal impedances. The fabricated power amplifier with 15${\times}$17.8 $mm^2$ shows the efficiency above 35 %, the power gain of 8.7~8.3 dB and the output power of 46.7~46.3 dBm at 9~9.5 GHz with pulsed-driving width of 10 usec and duty of 10 %.

A Study on Efficiency Improvement of X-Band Power Amplifier Using Harmonic Control Circuit (고조파 제어 회로를 이용한 X-대역 전력 증폭기의 효율 개선에 관한 연구)

  • Kim, Hyoung-Jong;Choi, Jin-Joo;Kim, Dong-Yoon;Na, Hyung-Gi
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.9
    • /
    • pp.987-994
    • /
    • 2010
  • In this paper, a simple and effective active load-pull method is proposed, and the method to improve the efficiency of X-band power amplifier using harmonic control circuit is presented. The proposed active load-pull system mainly consists of directional coupler, phase shifter, short circuit, and power amplifier, and allows a user to access reflection coefficients near the edge of the Smith chart($\Gamma$=1) easily. The device used in this paper is Mitsubishi's GaAs FET MGF1801, and the operating frequency of the power amplifier is 9 GHz, The amplifier had output power of 21.65 dBm and drain efficiency of 24.9 % at class-A, and had output power of 21.46 dBm and drain efficiency of 53.3 % at class-AB. Harmonic control circuit is designed only second and third harmonic components because of the bandwidth limitation of the microwave components. The drain efficiency is improved as much as 6.4 % compared with class-AB power amplifier.

A Study on Improving Performance of the Vehicular WAVE Antenna System using the EBG structure for ITS wireless communications (동향분석ITS 무선통신을 위한 EBG 구조를 적용한 자동차용 WAVE 안테나 시스템 성능향상연구)

  • Yeon, KyuBong;Lee, DuHo;Hwang, JinKyu;Yang, TaeHoon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.16 no.1
    • /
    • pp.176-185
    • /
    • 2017
  • This paper describes a design of the WAVE antenna system in V2X wireless communication systems for Intelligent Transport Systems. The WAVE standard protocols defined 5.825~5.9GHz frequency range for wireless communications with V2X. In a recent, A study of WAVE communication system it has been studied mainly the base station and the OBU technology in order to improve the communication performance of the communication distance. In this paper, the proposed vehicular WAVE antenna using the EBG structure is to improve performance. The proposed WAVE antenna with EBG shows improvement of return loss and radiation beam pattern. The performance of WAVE communication systems for intelligent transport systems is dependent on the performance of antenna. The proposed vehicular antenna for WAVE communication systems shows improvement of return loss for performance.

Clonality Assay of Dysplastic Epithelial Lesions of the Stomach (위 이형성 상피 병변의 클론성에 대한 분자병리학적 연구)

  • Choi Ho Soo;Kim Mi Sook;Park Jae Woo;Park Chang Soo;Kim Young-Jin;Juhng Sang-Woo
    • Journal of Gastric Cancer
    • /
    • v.1 no.3
    • /
    • pp.129-135
    • /
    • 2001
  • Purpose: Dysplasia or flat adenoma of the stomach is regarded as a precancerous lesion. However, the frequency and the evolutionary process of malignant transformation of gastric dysplasia are still debated. In order to see whether the lesion was a monoclonal or a polyclonal proliferation, clonality was assayed by X-linked HUMARA polymorphism. Materials and Methods: DNA was extracted from the paraffin-embedded tissue of 16 consecutive cases of endoscopic biopsy, eight of which supplied both dysplastic and nondysplastic tissue for comparison. HUMARA was amplified by PCR with or without pretreatment with methylationsensitive restriction enzyme, HpaII. The amplification products were electrophoresed on polyacrylamide gel and silver-stained. Results: Among the 16 cases, 13 cases were informative and 3 cases noninformative. Of the 13 cases, one case showed skewed lyonization, rendering 12 cases to be analyzed further. A monoclonal band pattern was noted in 2 cases, and a polyclonal band pattern in 10 cases. A review of the histopathologies of the monoclonal and the polyclonal cases did not reveal features discriminating the two groups. Conclusion: These results suggest that gastric dysplasia is a disease entity heterogeneous in the genetic level, and many cases may be non-neoplastic.

  • PDF

Development of 400MHz Wide-Band Correlation Board for Radio Astronomy Spectrometer (전파천문관측용 400MHz 광-대역 상관기 보드의 설계 및 제작)

  • Lee, Chang-hoon;Park, Han-Kyu;Kim, Kwang-Dong;Koo, Bon-Chul;Byun, Do-Young;Han, Seog-Tae;Kim, Tae-Sung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.2
    • /
    • pp.37-44
    • /
    • 2004
  • In this paper, we performed the design and the development of the wide-band correlation board to be an important role in the autocorrelation spectrometer's building for the observation study of an extra-galaxy's spectral lines and the survey research of the special radio sources in field of the radio astronomy. In this research, the developed correlation board by using QUAINT correlator chip(made by NRAO) has maximum 100 MHz clock speed and operate at a intermediate frequency with 400 MHz bandwidth. For the Performance test we supply the 0.5 and 1.67 MHz rectangular wave, then we obtain the autocorrelation coefficients. The final results, which process by using FFT, get the almost same results compare with the theoretical correlation.

Design and Fabrication of a Simple Orthogonal Mode Transduce with Good Iolation (Isolation 특성이 좋은 Orthogonal Mode Transducer 설계와 제작)

  • 오이석;이진원;홍진영
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.6
    • /
    • pp.914-919
    • /
    • 2000
  • A simple orthogonal mode transducer(OMT) for X-band has been proposed in this paper. This OMT is designed such that a polarized wave can be guided in a direction using several thin guiding posts, and the other orthogonally polarized wave can be guided in the other direction using other thin guiding posts. The OMT consists of a T-shaped waveguide section with guiding posts, two tapering waveguide arms, and has three flanges for connection with two adapters and an antenna. The optimum numbers and the optimum positions of the guiding posts were obtained numerically using the HFSS CAD tool. The isolation between two polarizations in a manufactured OMT is higher than 42.8 dB and the reflection from the OMT is lower than -17.5 dB at the frequency band of 9.5 GHz

  • PDF

An Experiment Study on the Effective Dielectric Constant of Microsrtip Line (마이크로스트립 선로의 실효 유전률에 관한 실험적인 연구)

  • 홍강지;하천주
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.19 no.3
    • /
    • pp.13-18
    • /
    • 1982
  • This Paper is an experimental study on the effective dielectric constant of microstrip line. To quantify the dispersive effects on a microstrip line, the effective dielectric constant, which is the ratio of free space wavelength to guide wavelength, is calculated for teflon substrates. The calculation is based on the Fourier transform of the current distribution on microstrip line. Measurements of effective dielectric constant using a microstrip elliptic resonator and ring resonator are also described. As a result, the computed values of effective dielectric constant agree almost all with measured values, using ring and elliptic resonator, in case of w/h or the ratio of microstrip width to substrate thickness equal unity over frequency range of 8 to 12GHz.

  • PDF

Morphological Properties and Target Strength Characteristics for dark banded rockfish (Sebastes inermis) (볼락의 형태학적 특징과 음향반사강도 특성)

  • Hwang, Bo-Kyu
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.51 no.1
    • /
    • pp.120-127
    • /
    • 2015
  • Morphological properties of dark banded rockfish (Sebastes inermis) were analysed to investigate its acoustic scattering characteristics. Total of 18 live samples was prepared for X-ray photos and collected morphological coordinates of their body and swim bladder shapes. Kirchhoff-ray mode model was used to calculate acoustic scattering pattern for broad-band frequency range. Inclination of swim bladder ranged from 17 to 30 and the averaged value was about $25.2^{\circ}$ (S.D.(standard deviation)=3.15). There were no any tendency of increase or decrease in volume and area ratio of swim bladder to fish body and ranged from 2.2 % to 4.43 % and 14.85 % to 21.31 %, respectively. The averaged value of volume and area ratio was 3.13 % (S.D.=0.52) and 17.6 % (S.D.=1.5). $b_{20}$ values were -69.01 for 38 kHz, -69.83 for 70 kHz, -70.17 for 120 kHz and -70.93 for 200 kHz, recpectively. Broadband acoustic patterns of dark banded rockfish for 20 ~ 200 kHz were similar among samples and they reflected size and morphological properties of fish species.